Military Engineer Services Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 71,920Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685805_1Tender No
8300/3296/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
28.8
-
-
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
620.66
-
-
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting in roof, walls etc with two corrugation side lap fixed with L-type or J-type or cranked hook bolts etc complete all as specified.
15.84
-
-
M&L for machine cut kota stone slab flooring 18mm -20 mm thick (of size not less than 575 mm X 575 mm), laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab with & including 20 mm thick screed bed in CM (1:4) including rubbing and beeswax polishing into mirror finish with roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust,etc.complete all as specifed & directed.
646.35
-
-
M&L for machine cut kota stone slab flooring 16mm -18 mm thick as in vertical surfaces such as skirting/dados in narrow width, laid over and including 10 mm thick rendering in cement mortar 1:3 on faces of brick work and jointed with grey cement slurry incl. including grinding, rubbing & with beewax polishing into mirror finish all as specified & directed.
30
-
-
Taking down strong air roof turbo ventilator exhaust fan of any sweep after disconnecting all necessary connections for repair and refixing in the same opening and same place & position complete all as specified & directed by Engineer-in-charge.
6
-
-
S & F stainless steel Non power Turbo ventilator polycarbonate base 600 mm dia shed mounted wind driven automatic grade of speed 960 RPM including cutting and fixing on galvalume sheet complete all as specified & directed by Engineer-in-charge.
2
-
-
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc & removing the debris from the premises upto 500 m from the MOD land complete all as specified and directed.
1537
-
-
M&L for 15mm thick (external) rendering (external) on brick or concrete surface in cement mortar 1:4, finishing surface even and smooth without using extra cement complete all as specified and directed.
82
-
-
M&L for rendering 10 mm thick (internal)on fair face brick masonry/concrete surface etc., in cement mortar 1:6, surface finished even & smooth without using extra cement complete all as specified and directed.
1455
-
-
M&L for prepatation of new plaster surface of walls and applying two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer (from same manufacturer of OBD) and a layer of wall care putty not less than 2mm thick complete all as specified and directed.
1455
-
-
M&L for preparation of newly plaster surface of wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
82
-
-
Taking down chowkats or frames with shutters exceeding 1.5 Sqm sqm but not exceeding 4.00 sqm each (without taking off shutters from the frames) etc including builders hardware etc and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed.
6
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed.
8
-
-
Forming jambs, etc, in CM 1:4 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed
9
-
-
S&F steel window with side hung shutters including box type hinges with steel handles and steel peg stay complete with glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx) & two Nos mild steel tower bolt 150 mm long and one peg stay on each leaf complete all as specified and directed
9.36
-
-
S & F for steel windows or ventilators, fixed type, with glazing bars complete including prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
0.6
-
-
M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge .
7.2
-
-
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed.
200
-
-
S&F Steel door including hinges, steel handle, looking arrangement etc complete with glazing bars, dovetailed or selded, complete all as specified and directed.
14.92
-
-
M&L for preparing new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed.
50
-
-
M&L for preparing old painted steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on steel surface complete all as specified and directed.
260
-
-
M&L for demolition of cement concrete (un reinforced) in ground floor & paving of any thickness (above or below ground level )by mechanical tools and removing excavated material exceeding 1.50 km and not exceeding 5.0 km complete all as specified and directed
34.85
-
-
M & L for 50 mm thickplain cement concrete type B-1, (1:2:4), using 20 mm graded stone aggregates as in floor finish even and smooth without using extra cement, complete all as specified and as directed.
697
-
-
M& L for forming contraction joints of 30mm X 10 mm wide primed and filled with sealing compound grade "A" complete all as specified and as directed.
19.3
-
-
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
30
-
-
M & L for point wiring for one light/exhaust fan point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc.,including cutting holes for sitches,sockets, regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
18
-
-
All as per item No .30 here-in-before but 3 pin socket outlet 5 Amp socket outlet on same board.with other switches
4
-
-
All as per item No .30 here-in-before but 3 pin socket outlet 5 Amp socket outlet on independent board.
4
-
-
M&L for point wiring FRLSH cable PVC for 15 amp 3 pin socket power point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
4
-
-
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
24
-
-
S & F Switch socket combination 2 in 1, 3 pin, 5Amp & 15 Amp flush type, universal, complete all as specified & as directed
4
-
-
S & F Socket 2 in 1, 3 pin, 5Amp , flush type, universal, complete all as specified.
4
-
-
S & F Switch socket combination 2 in 1, 3 pin, 5Amp flush type, universal, complete all as specified & as directed
4
-
-
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified & as directed
22
-
-
S&F LED light fitting 1X09W /1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
2
-
-
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge.
16
-
-
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts suitable amps rated busbar 8 way complete all as specified and directed by Engr-in-charge.
2
-
-
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral (SPN) and current carrying capacity 32 Amp with breaking capacity 10 KA, in the MCB DB with connection testing and commissioning complete all as specified and as directed.
2
-
-
S&F in repair 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles (SP) and current carrying capacity 6 to 32 Amp with breaking capacity 10 KA ,in the MCB DB with connection testing and commissioning complete all as specified and as directed.
12
-
-
M & L for Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and and testing on completion including taking down of existing sub main wiring complete all as specified & directed. Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of conduit shall be measured as one RM.
45
-
-
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq.mm.,2.0 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
40
-
-
Excavation in trenches in any type of soil not exceeding 0.45 metre deep and not exceeding 0.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
6.78
-
-
Returning, filling in, including spreading, levelling, watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
5.69
-
-
Removing excavated soil not exceeding 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
1.09
-
-
Supply and spreading clean, dry, fine river sand for under ground(UG) electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
2.57
-
-
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
192
-
-
M&L for Earthing complete for DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including making good disturbed surface of wall ,floors etc.including taking down/dismantling of existing earthing complete all as directed.
Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre.
(ii) Earth filling shall be done by vegetable soil.
(iii) Soil should be free from stone, boulders, aggregate, gravels etc.
1
-
-
S & F in repair 50mm dia GI pipe light grade for protection of LT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
8
-
-
M & L earthing complete with Gl electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to Gl earth strip 32 mm X6 mm as earthing leaad by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 40 mm dia Gl tubing light grade and necessary fitting for protection of Gl strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-l( using 20 mm graded crushed stone aggregate) earth pit with 40x40x6mm mild steel angle iron frame & 40mm thick pre cast RCC cover (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @ 75mm C/C both way with mild steel handle 12 mm dia round bars ,10mm thick plastering with cement mortar (1:4) internally and upto 150 mm below ground level externally, PGI funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1( 2009) and connected in earth test including testing and taking down existing old unserveciable earthing complete all specified and directed. Note: Earth strip and its protection pipe up to and including 7.5 mtr only from the top of earth electrode.
8
-
-
Supply, laying ,jointing and testing LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sq.mm.,3.5 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
11.5
-
-
S & F in repair 150mm dia GI pipe light grade for protection of LT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
5
-
-
up of 3.15 mm thick CRCA sheet as per IS:5039, water and vermin proof protection class IP-54 (front opening ) of outdoor type of floor mounted on pedestal CPRI approved factory made, totally enclosed, dust with locking arrangement duly painted wih powder coated paint of approved shade after minimum seven tank treatment process complete all as specified and as directed. The panel should be suitable for 415 Volts, 50 Hz, 3 phase 4 wire system and shall be fixed with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with complete assembly pre wired with suitable size PVC insulated copper conductor including taking down existing panel with , the panel should comprise following :- (At FE Area PRC) (A) Incoming :-
(i)MCCB 200 A,4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (ii)Spreader link for 200 amp four pole-01 No. (iii) Digital type MFM meter Aux supply 230 AC -01 No. (iv) R- phase indicating light Red LED Neon - 01 No. (v) Y- phase indicating light Yellow LED Neon - 01 No. (vi) B- phase indicating light Blue LED Neon - 01 No
(vii)Color coated copper strip main incoming bus bar of size 30mm X 3 mm rated 315 Amp 415 volt AC/50 Hz (R,Y,B & N) (viii) Copper wound CT Ratio-200/5-01 No.
(B)Outgoing :-(i)Color coated copper strip main outgoing Cu bus bar of size 20mm X 2 mm rated 185 Amp 415 volt AC/50 Hz (R,Y,B & N) (ii)MCCB 100 A,4 Pole, 415 V breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iii)MCCB 125 A, 4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (iv) MCB 32 A, DP, 415 V, breaking capacity 10 KA - 01 No. (v) Spreader link for 100 amp four pole-02 Nos. (vi) Spreader link for 125 amp four pole-01 No. (vii) Contractor 32A 3 pole coil voltage 230 V AC - 01 No. (viii) Digital Timer switch -01 No. Provision of cable connection terminal at back side wall of MCCB and epoxy powder coated both internally and externally complete including necessary cable connection including necessary foundation. Note : PCC foundation work will be includ in the unit quoted rate.
1
-
-
Supply,fabrication, installation , testing and commissioning of LT Panel (Size of Panel ) made up of 3.15 mm thick CRCA sheet as per IS:5039, water and vermin proof protection class IP-54 (front opening ) of outdoor type of floor mounted on pedestal CPRI approved factory made, totally enclosed, dust with locking arrangement duly painted wih powder coated paint of approved shade after minimum seven tank treatment process complete all as specified and as directed. The panel should be suitable for 415 Volts, 50 Hz, 3 phase 4 wire system and shall be fixed with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with complete assembly pre wired with suitable size PVC insulated copper conductor including taking down existing panel with , the panel should comprise following :- (At Sikh Lodge SRC) (A) Incoming :-
(i) MCCB 630 A,4 Pole, 415 V, breaking capacity 36 KAwith thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (ii)Spreader link for 630 amp four pole-01 No. (iii) Digital type MFM meter Aux supply 230 AC -01 No. (iv) R- phase indicating light Red LED Neon - 01 No. (v) Y- phase indicating light Yellow LED Neon - 01 No. (vi) B- phase indicating light Blue LED Neon - 01 No
(vii)Color coated copper strip main incoming bus bar of size 80mm X 5 mm rated 970 Amp 415 volt AC/50 Hz (R,Y,B & N) (viii) Copper wound CT Ratio-630/5-, 5 VA- 01 No.
(B)Outgoing :-(i)Color coated copper strip main outgoing Cu bus bar of size 50mm X 5 mm rated 630 Amp for 400A MCCB & 25 X3 mm rated 270 A Cu bus bar for 160 A MCCB AC/50 Hz (R,Y,B & N) (ii)MCCB400 A 4 Pole, 415 V, breaking capacity 36 KA with thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (iii)MCCB160 A4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iv) MCB 32 A, DP, 415 V, breaking capacity 10 KA - 01 No. (v) Spreader link for 400 amp four pole-01 No. (vi) Spreader link for 160 amp four pole-02 Nos. (vii) Contractor 32A 3 pole coil voltage 230 V AC - 01 No. (viii) Digital Timer switch -01 No. Provision of cable connection terminal at back side wall of MCCB and epoxy powder coated both internally and externally complete including necessary cable connection including necessary foundation. Note : PCC foundation work will be includ in the unit quoted rate.
1
-
-
Supply,fabrication, installation , testing and commissioning of LT Panel (Size of Panel ) made up of 3.15 mm thick CRCA sheet as per IS:5039, water and vermin proof protection class IP-54 (front opening ) of outdoor type of floor mounted on pedestal CPRI approved factory made, totally enclosed, dust with locking arrangement duly painted wih powder coated paint of approved shade after minimum seven tank treatment process complete all as specified and as directed. The panel should be suitable for 415 Volts, 50 Hz, 3 phase 4 wire system and shall be fixed with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with complete assembly pre wired with suitable size PVC insulated copper conductor including taking down existing panel with , the panel should comprise following :- (At 20/5 Camp SRC) (A) Incoming :-
(i)MCCB 400 A, 4 Pole, 415 V, breaking capacity 36 KA with thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (ii)Spreader link for 400 amp four pole-01 No. (iii) Digital type MFM meter Aux supply 230 AC -01 No. (iv) R- phase indicating light Red LED Neon - 01 No. (v) Y- phase indicating light Yellow LED Neon - 01 No. (vi) B- phase indicating light Blue LED Neon - 01 No
(vii)Color coated copper strip main incoming bus bar of size 50mm X 5 mm rated 630 Amp 415 volt AC/50 Hz (R,Y,B & N) (viii) Copper wound CT Ratio-400/5-, 5 VA- 01 No.
(B)Outgoing :-(i)Color coated copper strip main outgoing Cu bus bar of size 30mm X 3 mm rated 315 Amp (R,Y,B & N) (ii)MCCB 200 A, 4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iii) MCCB 160 A, 4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iv) MCB 32 A, DP, 415 V, breaking capacity 10 KA - 01 No. (v) Spreader link for 400 amp four pole-01 No. (vi) Spreader link for 160 amp four pole-02 Nos. (vii) Contractor 32A 3 pole coil voltage 230 V AC - 01 No. (viii) Digital Timer switch -01 No. Provision of cable connection terminal at back side wall of MCCB and epoxy powder coated both internally and externally complete including necessary cable connection including necessary foundation. Note : PCC foundation work will be includ in the unit quoted rate.
1
-
-
Supply,fabrication, installation , testing and commissioning of LT Panel (Size of Panel ) made up of 3.15 mm thick CRCA sheet as per IS:5039, water and vermin proof protection class IP-54 (front opening ) of outdoor type of floor mounted on pedestal CPRI approved factory made, totally enclosed, dust with locking arrangement duly painted wih powder coated paint of approved shade after minimum seven tank treatment process complete all as specified and as directed. The panel should be suitable for 415 Volts, 50 Hz, 3 phase 4 wire system and shall be fixed with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with complete assembly pre wired with suitable size PVC insulated copper conductor including taking down existing panel with , the panel should comprise following :- (At 20/4 Camp SRCin front of SPMK) (A) Incoming :-
(i) MCCB 400 A, 4 Pole, 415 V, breaking capacity 36 KA with thermal magnetic release conforms to IS/IEC 60947-2- 01 No. (ii)Spreader link for 400 amp four pole-01 No. (iii) Digital type MFM meter Aux supply 230 AC -01 No. (iv) R- phase indicating light Red LED Neon - 01 No. (v) Y- phase indicating light Yellow LED Neon - 01 No. (vi) B- phase indicating light Blue LED Neon - 01 No
(vii)Color coated copper strip main incoming bus bar of size 50mm X 5 mm rated 630 Amp 415 volt AC/50 Hz (R,Y,B & N) (viii) Copper wound CT Ratio-400/5-, 5 VA- 01 No.
(B)Outgoing :-(i)Color coated copper strip main outgoing Cu bus bar of size 30mm X 3 mm rated 315 Amp (R,Y,B & N) (ii) MCCB 200 A, 4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iii) MCCB 160 A, 4 Pole, 415 V, breaking capacity 25 KA with thermal magnetic release conforms to IS/IEC 60947-2- 02 Nos. (iv) MCB 32 A, DP, 415 V, breaking capacity 10 KA - 01 No. (v) Spreader link for 200 amp four pole-01 No. (vi) Spreader link for 160 amp four pole-02 Nos. (vii) Contractor 32A 3 pole coil voltage 230 V AC - 01 No. (viii) Digital Timer switch -01 No. Provision of cable connection terminal at back side wall of MCCB and epoxy powder coated both internally and externally complete including necessary cable connection including necessary foundation. Note : PCC foundation work will be includ in the unit quoted rate.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%