Military Engineer Services Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date10 Jan 2025
Closing Date31 Jan 2025
Tender Amount₹ 43,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonement area, reassambling and refixing the same with pump in original position for the 1/1.5/2.5 HP 3 phase complete all as directed by Engr-in-Charge.

4

-

-

... More
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonement area, reassambling and refixing the same with pump in original position for the 60/50 HP 3 phase complete all as directed by Engr-in-Charge.

2

-

-

... More
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonement area, reassambling and refixing the same with pump in original position for the 100/120 HP 3 phase complete all as directed by Engr-in-Charge.

1

-

-

... More
Following spares parts for centrifugal pump set :-

-

-

-

... More
Supply only Impeller CI as spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as specified and directed.

2

-

-

... More
Supply only Pump shaft as spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as specified and directed.

2

-

-

... More
Supply only Neck ring as spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as specified and directed.

4

-

-

... More
Supply only Shaft Sleeve as spare par for pump set including motor complete all as specified and directed.

4

-

-

... More
Supply only Bearing (as per sample) as spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as specified and directed.

4

-

-

... More
Dismantling of all electric & water connections ,lifting of submersible pump and motor including column pipe with the help of chain pulley block for pump capacity 15 HP opening of pump and motor, cleaning, servicing and replacement of spare parts as & when required directed by Engr-in-Charge complete all as specified and directed.. Note: Spare parts, as & when required for renewal shall be measured and paid separately..

1

-

-

... More
M & L for rewinding work for 3 phase submersible motor of capacity 15 HP with new PVC insulatedd super enammel copper wire of suitable gauge as per existing complete all as specified and as directed.

1

-

-

... More
Supply only Impeller CI as spare part for pump set including motor complete for 15 HP centrifugal pump, complete all as specified and directed.

1

-

-

... More
Supply only Neck ring as spare part, for pump set including motor complete for 15 HP centrifugal pump, complete all as specified and directed.

2

-

-

... More
Supply only Bearing ( as per sample ) as spare part for pump set including motor complete for 15 HP centrifugal pump, complete all as directed.

2

-

-

... More
S & F in repair for nut, bolt and wahers of suitable sizes for fixing in different spare parts of pump and motor, complete all as specified and as directed.

4

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 70 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

35

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 50 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

50

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 35 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

50

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 25 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

50

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 16 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

50

-

-

... More
S & F in repair water proof un armoured multistranded copper cable 10 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.

50

-

-

... More
S&F in repair tyre coupling of series F 80 suitable for 50/60 HP centrifugal pumping set complete all as specified and as directed.

4

-

-

... More
S&F in repair tyre coupling of series F 90 suitable for 50/60 HP centrifugal pumping set complete all as specified and as directed.

4

-

-

... More
S&F in repair Rubber star coupling of suitable sizes for fixing in pump, complete all as specified and as directed.

2

-

-

... More
S&F Copper thimbles of size 25 Sqmm to 50 Sqmm of single core and including removing burnt thimbles from existing copper cables and cable make to suitable for fixing new thimbles complete all as specified and directed.

18

-

-

... More
S & F in repair DOL Starter suitable for 3 HP suitable for 2.5/3HP monoblock centrifugal pumping set for cleaning compressor of Iron Removal Plant(IRP), complete all as specified and as directed. .

2

-

-

... More
Repairs and maintenance of Chemical Dozing pumps of any make and capacity including fixing of replacement of defective / unserviceable spare parts suction/discharge pipe 3/8", duck bill & connecting nut 3/8" etc after taking out the old ones with new ones complete : Note :-(i) Cost of minor repairs / replacement of minor spares such as nuts, bolts, washers etc. are deemed to be included in the unit quoted rates. (ii) The cost of transportation to nearest workshop & back after repair if necessary is deemed to be included in the unit quoted rates. (iii) Spare parts such as pump tube, Injection Check valve,foot valve 3/8" & connecting with adapter 3/8" as & when required for renewal shall be measured and paid separately.

3

-

-

... More
Following spares parts for Chemical Dozing pumps :-

-

-

-

... More
Supply only pump tube of Chemical Dozing pumps complete all as specified and directed.

3

-

-

... More
Supply only injection Check valve of chemical Dozing Pumps, complete all as specified and directed.

3

-

-

... More
Supply only foot valve 3/8" of chemcial dozing pumps, complete all as specified and directed.

3

-

-

... More
Supply only connecting with adapter 3/8" of Chemical dozing pumps, complete all as specified and directed.

3

-

-

... More
Supplying and laying of CPVC pipes with SDR 13.5 & plain CPVC SDR 13.5 fittings of 50mm dia (outer dia) laid in trenches including taking down of existing pipe complete all as specified and as directed.

40

-

-

... More
Supplying and laying of CPVC pipes with SDR 13.5 & plain CPVC SDR 13.5 fittings of 50mm dia (outer dia) laid in trenches including taking down of existing pipe complete all as specified and as directed.

35

-

-

... More
Supplying and laying of CPVC pipes with SDR 13.5 & plain CPVC SDR 13.5 fittings of 40mm dia (outer dia) laid in trenches including taking down of existing pipe complete all as specified and as directed.

25

-

-

... More
Supplying and laying of CPVC pipes with SDR 13.5 & plain CPVC SDR 13.5 fittings of 25 mm dia (outer dia) laid in trenches including taking down of existing pipe complete all as specified and as directed.

20

-

-

... More
Supplying and laying of CPVC pipes with SDR 13.5 & plain CPVC SDR 13.5 fittings of 20mm dia (outer dia) laid in trenches including taking down of existing pipe complete all as specified and as directed.

20

-

-

... More
S&F in repair fully automatic Satr Delta Starter suitable in sheet-steel enclosure with IP 54 protection (Motor Rating AC-3 Duty, 415V, 50Hz, 3 Ph) for 125 HP for centrifugal pump set max relay setting 78-130 Amps, coil voltage 380 volts, Contactor size 115, conforming to IS/IEC 60947-1 and IEC 60947-4-1 including accessories, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in repair fully automatic Satr Delta Starter suitable in sheet-steel enclosure with IP -54 protection (Motor Rating AC-3 Duty, 415V, 50Hz, 3 Ph) for 60 HP centrifugal pump set max relay setting 45A-65A Amps, coil voltage 380 volts, Contactor size 50, conforming to IS/IEC 60947-1 and IEC 60947-4-1 including accessories, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&Fin repair fully automatic Satr Delta submersible pump Starter suitable in sheet-steel enclosure with IP 54 protection (Motor Rating AC-3 Duty, 415V, 50Hz, 3 Ph) for 15/20 HP centrifugal pump set max reay setting 22A-30A Amps,conforming to IS/IEC 60947-1 and IEC 60947-4-1 including all accessoreis, complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply, install, testing and commissioning of LT panel board outdoor type (of suitable size 800mm x 800mm x 500mm) floor mounted on pedestal CPRI approved factory made, totally enclosed, dust and vermin proof (protection class IP-54) ( FRONT OPENING) with locking arrangement made out of mild steel angle iron frame 50mm x50mmx 6mm complete and made out of 3.15 mm thick CRCA sheet as per IS: 5039 duly painted with powder coated paint of approval shade after minimum seven tank treatment process complete all as specified and as directed. The panel should be suitable for 415 Volts, 50 Hz, 3 phase 4 wire system and shall be fixed with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with complete assembly pre wired with suitable size PVC insulated copper conductor, the panel should comprise with the following:- (a) Incoming:- (i) MCCB 100 Amp, 4 Pole 415 V breaking capacity 25 KA -01 No. (ii) Digital multifunctional meter with selector switch -01 No. (iii) Digital LED indicator for R-Y-B phase-01 set (b) Outgoing:- (i) MCCB 40 Amp, 3 Pole 415,breaking capacity -25KA, -01 No. (ii) Spare Space -1 No existing star delta starter 15 HP. Provision of cable connection terminal at back side wall of MCCB and epoxy powder coated both internally and externally complete including necessary cable connection including necessary foundation. Note- PCC foundation work will be included in the unit quoted rate. Taking down of old unserveciable existing LT panel and Existing star delta starter 15 HP and refixing the existing star delta starter included in unit quoted rate and shall be taken by the contractor as credit.

1

-

-

... More
M&L for spray painting to exposed surfaces of centrifugal pumping set of any capacity and size with two coats of synthetic enamel anti corrosive paint and dust free paint, (as per existing colour) over a coat of red oxide primer including complete removal of old painted surface by scraping,preparation of surface & filling cavities with filler and writing MES/SM No. over painted surface complete all as specified and directed.

10

-

-

... More
M&L for spray painting to exposed surfaces of GI/CI pipe line of any size with two coats of synthetic enamel dust and weather proof paint of approve make, (as per existing colour) over a coat of red oxide primer, including preparation of old surfaces of pipes, by scraping or complete removal of rusting to the pipes, filling cavities with filler, complete all as specified and directed.

120

-

-

... More
Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 1.5 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, re-installing in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star

5

-

-

... More
Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 2.0 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, reinstalling in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation. Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star

3

-

-

... More
Material & Labour for replacement of rusted body portions of split type AC/Window type AC unit of 1.5/2.0 tonne capacity with same gauge / size materials like MS sheet, angle iron similar to the existing one by removing existing, foam pad and components and scraping out/removal of old paint on complete body, cleaning surface thoroughly, applying two coats synthetic enamel paint of approved shade over a coat of red oxide primer, fixing of new foam pad of not less than 3mm thick, refixing of all components, testing and installation in original position, connecting up all electrical connections, testing and commissioning all as specified and directed.

2

-

-

... More
S&F in repair for fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for existing makes and rotation in the casing testing including taking out the defective condenser fan blade all specified and directed. Make : Kirloskar/Crompton/ Jyoti/ABB/KSB /NGF/BCH or equivalent as approved by GE

2

-

-

... More
M&L for Evoporator fan blower motor of suitable capacity duly ISI marked, double inlet, double width centrifugal type suitable for 1.5/2.0 Ton capacity split type AC including taking down the unserviceable damaged blower complete all as specified and directed.

4

-

-

... More
Supply and fix in repair swing motor for ACs suitable for existing size and capacity of 1.5/2 Ton complete all as specified and directed.

4

-

-

... More
Complete Scrapping the existing painted surface of split type A C and window type AC, cleaning the surface thoroughly and apply two coats of approved synthetic enamel paint over a coat of red oxide primer including preparation of surface for any capacity of ACs complete all as specified and directed.

4

-

-

... More
M&L for repair and replacement Single pole contactor for 1.5/2.0 tonne capacity of split type ACs complete all as specified and directed.

7

-

-

... More
M&L for repair and replacement of thermal insulation for 1.5/2.0 Ton split type ACs complete all as specified and directed.

25

-

-

... More
M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed.

10

-

-

... More
M & L for Running capacitors of 50/60 MFD suitable for 1.5/2.0 Ton Capacity split type AC/window type AC including taking down existing unserviceable running capacitors complete all as specified and directed.

10

-

-

... More
M&L for Starting Capacitor of 100/120 MFD suitable for 1.5/2.0Ton Capacity split type AC/Window type AC including taking down old unserviceble staring capacitor complete all as specified and directed.

10

-

-

... More
M&L for Drain connection and drain trap for 1.5/2.0 Ton capacity of split type ACs in repairs complete all as specified and directed.

8

-

-

... More
Supply and fix in repair wiring kit suitable for 1.5/ 2.0 Ton capacity of split type AC/Window type ACs complete all as specified and directed.

8

-

-

... More
M&L for replacement of capillary tube set suitable for 1 5/2.0 ton capacity of split type AC including taking down the unserviceable defective capillary tube set all as specified and directed.

8

-

-

... More
M&L for replacement of rusted mild steel stand suitable for mounting out door unit of split type AC as per existing size & shape complete all as specified and directed.

5

-

-

... More
M&L for servicing carefully any type of AC of cap 1.5/2.0 TR from site and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, cleaning, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas and re assembling the dismantled components and fixing to its original position all as specified and directed.

25

-

-

... More
M&L for shifting of Split AC of 1.5/2.0 TR capacity including removing indoor cooling machine, copper piping, drain pipe and thermal sleeve, lifting angle with necessary re-fixing arrangement on wall surface, copper piping of suitable gauge for suction and delivery with insulation, including re-surfacing to disturbed surface and testing and commissioning all as specified. (Note: The copper pipe required will be measured against relevent items in this schedule)

5

-

-

... More
S & F in repair sheet metal enclosures Single pole and neutral (SPN), with a two pin earth plug and socket with one single pole MCB 20-32A Amps,"C" curve complete all as specified and as directed.

5

-

-

... More
Material and Labour for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccuminising and charging with refrigerant gas and topping up compressor oil, testing and commissioning of split type ACs/window type ACs of 1.5/2.0 Ton capacity complete all as specified and as directed. Note : Refrigerant gas will be measured and paid separately under respective item of BOQ.

5

-

-

... More
M & L for gas charging with refrigerant gas (R-22, R-134) in new sealed/existing unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Removal of the unserviceable temperature sensor probes and supply and fix new temperature sensor probes in the main circuit of split type AC complete all as specified and as directed by Engineer-in-charge.

15

-

-

... More
S & F in repair Printed Circuit Board (PCB Board) for any type of AC units suitable for 1.5 TR to 2.0 TR, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/ Videocon /LG/National aircon/Bluestar/Carrier as approved by GE

5

-

-

... More
S & F in repair remote controller unit suitable for split type ACs/widow type ACs unit of 1.5/2.0 Ton capacity complete all as specified and as directed. Make : Voltas/Videocon/LG/National aircon/Bluestar/ Carrier as approved by GE

5

-

-

... More
S & F in repair for PVC drain pipe of 15mm/20 mm dia with suitable clamps on walls and ceiling all as specified and as directed.

30

-

-

... More
S & F in repair cooling coil of 1.5/1/2 ton AC units including necessary welding/brazing of copper pipes line, testing of leakage, complete all as specified and as directed by Engineer-in-charge.

10

-

-

... More
Supply & fix in repair cooling motor for walk in cooler complete all as specified and as directed.

1

-

-

... More
Supply & fix in repair remote sensor for walk in coolercomplete all as specified and as directed.

1

-

-

... More
Supply & fix in repair thermostat for walk in cooler complete all as specified and as directed.

1

-

-

... More
Supply & fix in repair condenser for walking cooler of capacity 3.6/4.2 mfd complete all as directed.

1

-

-

... More
Supply & fix in repair cooling coil for walk in cooler complete all as directed.

1

-

-

... More
S & F in repair air filter for AC of any size, complete all as specified and as directed by Engineer-in-charge. Make : Kirloskar/Tenacity/Athelete or equivalent as approved by GE

10

-

-

... More
S & F in repair for PVC cable 3 core 4 Sqmm unsheathed multi stranded copper conductor, complete all as specified and as directed by Engineer-in-charge. Make : Havells/Polycab/Finolex/Plaza/Anchor.

50

-

-

... More
S & F in repair strainer filter for AC complete all as specified and as directed by Engineer-in-charge. Make : Voltas/LG/Godrej/Bluestar/Kirloskar/Carrier or equivalent as approved by GE.

15

-

-

... More
S & F in repair copper pipe as per existing size including necessary welding/brazing/making threading required length, complete all as specified and as directed by Engineer-in-charge.

40

-

-

... More
S & F in repair air grill for split AC as existing size/shape /design & make, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/Videocon/LG/National aircon/Bluestar/Carrier as approved by GE

10

-

-

... More
Taking down unserviceable water cooler from the site and transporting the same for repair, removing the unserviceable burnt sealed unit (compressor) from the water cooler and S&F factory overhauled compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity 40/80 ltr complete all as specified and as directed by Engineer-in-charge. Make –Usha/Arco/Sidhwal. Note :Gas charging shall be measured and paid separately against relevant item.

10

-

-

... More
S & F in replacement of running capacitor (10 mfd) for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-charge.

30

-

-

... More
S & F in replacement of starting relay for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-charge.

30

-

-

... More
Taking down old defective over load protector and S&F new over load protector of suitable capacity/size for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge.

25

-

-

... More
S & F in repair starting capacitor (40/60 mfd) for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge. Make : Asian/Unistar/Arvind.

10

-

-

... More
Taking out old unserviceable internal wiring and rewiring the same guage and size with flexible copper conductor single core with terminal clips etc including screws, washers etc required for fastering with body complete all as specified and as directed by Engineer-in-charge.

10

-

-

... More
Taking down rusted front and back body MS cover and S&F new 2mm thick MS plate cover of duly painted to match the existing shade of water cooler complete all as specified and as directed by Engineer-in-charge..

5

-

-

... More
S & F in replacement of unserviceable float valve with new Ball/float valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) ball suitable for 15mm dia of GI pipe complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
Taking out old unserviceable 15mm dia water tap and S&F new self closing chromium plated push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Taking out old unserviceable fan motor and S&F new fan motor suitable for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
M&L for cleaning of water cooler complete internally and externally including scraping and complete removing of existing treatment, scales and dirt etc.and applying of two coats of synthetic enamel tone paint with sparay machine over a coat of red oxide primer all as specified and as directed

5

-

-

... More
.Taking down unserviceable refrigerator of capacity 250 Ltr to 310 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engr –in-charge. Note : Gas charging shall be measured and paid separately under respective item of BOQ..

5

-

-

... More
Taking down unserviceable refrigerator of capacity 165 Ltr to 190 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.

3

-

-

... More
S & F in replacement of unserviceable of freezer door (plastic) with existing size & shape , match with existing shade complete with tension spring as per original complete all as specified and directed by Engineer –in-Charge.

5

-

-

... More
S & F in replacement of fruit/vegetable tray as per original size & shape complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
S & F in replacement of unserviceable tray with new as per original complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
S & F in replacement of pgmy lamp (bulb) as per the existing complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
S & F in replacement of door liver (plastic) as per original complete all as specified and directed by Engineer -in-Charge..

5

-

-

... More
S & F in replacement of door magnetic gasket as per original make for any capacity of Refrigerator complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
S & F in replacement of ice chamber as per original make for any capacity of Refrigerator complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
S & F in replacement of unserviceable relay PTC single pole for any type and any capacity of refrigerator complete all as specified and directed by Engineer -in-Charge.

10

-

-

... More
S & F in replacement of over load relay protection as per the existing capacity of refrigerator complete all as specified and directed by Engineer -in-Charge..

10

-

-

... More
Opening of regrigator of any capacity for servicing and refixing the same after flushing out and removal blockage, brazing replacement of liquid line filter and recharging the regrigation gas R-22 to obtain the desired cooling complete all as specified and directed by Engineer -in-Charge. Note : Refrigerant gas will be measured and paid separately under respective item of BOQ.

10

-

-

... More
M&L for spray painting of refrigerator with synthetic enamel paint after preparation of old surface of refrigerator capacity 310/286/165 ltr of any make/mode/shadel complete all as specified and directed by Engineer -in-Charge.

5

-

-

... More
Taking out deep freezer of 300 litre capacity from the site for complete servicing of Deep freezer units by electically disconnecting the units and cleaning the compressor , condenser , piping suction/discharge suction, fan motor, cooling coils, cooler body and connected accessries with the help of blower unit , cleaning the same with water and caustic soda for condenser and piping unit , tighten all nuts , bolts, screws etc checking the door bedding , electrical controls of the cooling units rectify where necessary and refixing in its original site and testing comlete all as specified and directed by Engineer-in-charge

2

-

-

... More
S & F new sealed unit compressor for deep freezer as per existing make and size & capacity as approved by GE complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
S & F running capacitor 10 mfd including taking out capacitor complete all as specified and as directed by Engineer-in-charge.

8

-

-

... More
S & F in repair fan motor for deep freezer complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
S & F in repair relay PTC double pole for deep freezer as per sample, complete all as specified and as directed by Engineer-in-charge.

8

-

-

... More
M & L for body patching including denting at certain place of deep freezer and then spray painting with match of existing finishing complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S & F in replacement of Voltage stabiliser, copper wound of 5 KVA capacity digital display type having I/P Correction Range of 140 - 280 volt complete all as directed.

5

-

-

... More
Disconnecting carefully water and electric connection from storage type water heater of 25/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing including replacement of flexible cable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note:- The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality if required at site.

30

-

-

... More
S & F in repair heating element including rubber gasket & washer etc. of capacity 2 KW suitable for existing make and shape all as specified and directed.

25

-

-

... More
S & F in repair heating element including rubber gasket & washer etc. of capacity 1.5 KW suitable for existing make and shape all as specified and directed.

25

-

-

... More
S&F Thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed.

50

-

-

... More
Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed.

5

-

-

... More
&L for preparation of surface of geyser 25 Ltrs /35 Ltrs /50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding if required at site all as specified and directed.

15

-

-

... More
S&F PVC connecting pipe 18" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.

30

-

-

... More
S&F bottom covers (set of two halves) duly painted made out of Aluminium sheet of 18 SWG suitable for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers complete all as specified and as directed.

5

-

-

... More
S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and as directed.

5

-

-

... More
S &F in replacement inner stainless steel dome of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.

5

-

-

... More
S & F in replacement inner stainless steel dome of geyser of capacity 35 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.

2

-

-

... More
S&F indication lamp for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed.

12

-

-

... More
S&F in repair PVC insulated copper cable 3 core of size 2.5 Sqmm to any capacity geysers as required length complete all as specified and as directed.

21

-

-

... More
S & F in repair Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F 3D channel letters mounted on an ACP base frame in 3D form-factor supported by digital technology to be illuminated in case of dull light conditions to highlight installation and office name with distinctive LED glow includihng fabrication and on-site installation, the side border made of metal strip (signmakers refer to this border as aluminium profile strip or channel patti), fabricating our letter on not less than 3 inches thick aluminium channel to turn it into the desired shape with laser cut acrylic sheet mounted on top of shaped channle, resulting in a beautiful letter with a metallic finish on th sides with acrylic sheet on the top giving a backlit effect and stunning, well-lit letter for signboard, complete all as specified and as directed.

400

-

-

... More
S&F fix 2D channel letters m ounted on an ACP base frame in 2D form-factor supported by digital technology to be illuminated in case of dull light conditions to highlight installation and office name with distinctive LED glow includihng fabrication and on-site installation, the side border made of metal strip (signmakers refer to this border as aluminium profile strip or channel patti), fabricating our letter on not less than 3 inches thick aluminium channel to turn it into the desired shape with laser cut acrylic sheet mounted on top of shaped channle, resulting in a beautiful letter with a metallic finish on th sides with acrylic sheet on the top giving a backlit effect and stunning, well-lit letter for signboard, complete all as specified and as directed

3500

-

-

... More
S&F ACP board with ACP as the base material for mounting of letters onto it to ensure high gloss surface finish, with wieres easily concealed behind the meatl panel in case of ACP base frame, lightweight, weatherproof and fire redundant with maintenance free spectacular glow, complete all as specified and as directed.

1750

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq mm 2 core nominal cross section including testing including taking down of existing cable complete all as specified and as directed.Note: Excavation ,earth work ,sand cushioning,cable cover for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)

400

-

-

... More
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations, shafts, well, cesspits, manholes etc.complete all as specified and directed.

19.8

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.

1320

-

-

... More
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.

12

-

-

... More
S&F 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1m apart including 4mm suspension wire one twin core cable flat or circular of size 4 sqmm including taking down of existing cable complete all as specified and as directed.

250

-

-

... More
Supply and laying GI pipe 15 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.

70

-

-

... More
Boring of hole under road, pavement, hard standing without disturbing existing surface by using MANUAL hand drill or necessary machine complete all as specified and directed by Engineer-in-Charge. Note :(i) Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/ apron /floors etc.complete all as specified and as directed. (ii) T&P required for boring to be provided by the bidder at site own arrangement and not any claim entertained on this account at later stage.

35

-

-

... More
M&L for carrying out minor repairs to LED boards with necessary replacement of electronic circuit diodes, FETs etc or LED sigh bulb complete all as specified and directed.

20

-

-

... More
Supply only rotary manual hand operated oul barel pump extractor for drum with dual direction operation with U-shaped oul outlet tube, barrel fixing cover and filter attached to suction side of cast iron tube alongiwth 2 m PVC flexible pipe for fuel extraction etc complete all as specified and as directed.

6

-

-

... More
Supply only 90 degree dip rod liquid level measurement gauge stick for 220 Ltrs oil barrel drum height gauge comple all as specified and as directed.

6

-

-

... More
Supply and installation of fire bucket stand for 4 buckets consisting of 4 hooks to hold 4 buckets filled with sand or water made out of iron material and coated with bright red colour weighing around 6 Kg, hanging type and display of "FIRE" in English one one side and in Hindi on other side complete all as specified and as directed.

8

-

-

... More
Repair/maintenance of compressor machine (existing make BOSCH, Model No. AQUATEK 125-1500 WATT) of high speed washer with minor replacement of spares if any complete all as specified and directed.

1

-

-

... More
Supply only SMPS based battery charger, DC charging rated 12A, 12-48 V suitable for 1 to 4 batteries inclusive of digital indication of charging current and voltage level of the battery, battery clamps made from copper alloy with brass terminals for allowing connections to be made to the battery in either direction, connection wire length fo minimum 2mtrs.

2

-

-

... More
Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ re-installation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard to site location )shall be made through proper issue/receipt voucher duly mentioning by MES rep.

1090

-

-

... More
Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/ overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as& when required (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-charge.

530

-

-

... More
Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified.

950

-

-

... More
Supply only Gun Metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified.

30

-

-

... More
Servicing exhaust fans of 450 mm /300 mm/225 mm /any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-charge.

30

-

-

... More
M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.

450

-

-

... More
M&L for cutting of existing winding of ceiling fans of 1400 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.

40

-

-

... More
M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge.

15

-

-

... More
M&L for cutting of existing winding of exhaust fans of 300 mm/250 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge/concerned ground executive.

25

-

-

... More
S &F in repair 2.5 mfd capacitor suitable for ceiling fans of 1200 mm/1400 mm sweep of approved make complete all as specified & directed by Engineer-in-charge.

1050

-

-

... More
S &F in repair 4 mfd capacitor suitable for exhaust fans of 300 mm to 450 mm sweep of approved make complete all as specified & directed by Engineer-in-charge

35

-

-

... More
S &F in repair mild steel clamps of suitable size & shape with rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans complete all as specified & directed.

80

-

-

... More
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 550 mm long & wall thick ness not less than 1.6 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.

15

-

-

... More
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 1250 mm long & wall thick ness not less than 1.6 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.

10

-

-

... More
S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) duly painted complete all as specified & directed by Engineer-in-charge.

15

-

-

... More
S &F in repair PVC flexible wire of size 23/.0076 Sqmm or 0.50 sqmm multi stranded, twin core, PVC sheathed copper conductor complete all as specified & directed by Engineer-in-charge.

100

-

-

... More
M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge.

250

-

-

... More
M&L for preparation of old rusted surface of exhaust fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (brown shade) paint and marking MES number with non erasable marker pen with black colour all as directed by Engineer-in-charge.

20

-

-

... More
S & F in repair fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt on the existing phenolic laminated sheet etc complete all as specified and as directed.

50

-

-

... More
S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer in Charge.

20

-

-

... More
S & F in repair blade set suitable for ceiling fan 1200 mm/1400 mm sweep of any make as per site requirement complete all as specified and as directed.

25

-

-

... More
S & F in repair metal blades set suitable for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and as directed.

10

-

-

... More
S & F in repair PVC blades set suitable for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and directed.

10

-

-

... More
S & F in repair for metal fan blades of best quality suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F for PVC fan blades of best quality suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F in repair for Front Grill Double Partition type of 20 SWG metal grill, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all accessories as required including taking out/ down unserviceable one, complete all as specified and as directed.

15

-

-

... More
S & F in repair for motor suitable 1/7 HP, 180 watt, 3 speed for Desert Cooler, copper wounded complete and one set of lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed.

35

-

-

... More
S&F for 15 mm dia Plastic PVC distributor suitable size for Desert Cooler heavy duty with elbow, Tee, etc. fixed with bolts, nut & washers including taking out/down unserviceable one, complete all as specified and as directed.

30

-

-

... More
S & F Plastic PVC Pipe( ISI mark) of 15mm bore suitable for Desert Cooler, heavy duty, including taking out/down unserviceable one, complete all as specified and as directed.

18

-

-

... More
S&F Selector Switch suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.

25

-

-

... More
S&F Submersible water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed.

40

-

-

... More
S&F Plug Top, 3 pin 5/6 Amp inluding taking out/down unserviceable one , complete all as specified and as direcrted

10

-

-

... More
M&L for mild steel Desert Cooler Body fabricated/ made out of 20 SWG with powder coated including 03 Nos side shutters of fabricated/ made out of 22 SWG, (size 3 ft x 2 ft x 2ft), noise pollution control complete body including taking out/ down unserviceable one, complete all as specified and as directed. Note:If size is not available, then next higher size shall be brought by contractor at no extra cost to department and not any claim entertained on this account at later stage.

14

-

-

... More
S & F in replacement cooler stand made out of equal angle iron (size 30 mm x30 mm x 3mm ) with 25 mm cross support between angle frame and both side of front and back stand legs for desert cooler with applying one coat of synthetic enamel paint over a coat of red oxide primer on exposed surface of stand complete all as specified and directed.

60

-

-

... More
S&F Grass Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed.

45

-

-

... More
M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying one coat of synthetic enamel paint (as approved) with spray gun machine of outer surface of cooler and inner side of tank with black bituminous paint complete all as specified and as directed.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.