Military Engineer Services Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678322_1Bid Award Id
ViewTender No
C/8706/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as per item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches,complete all as specified and as directed.
20
-
10
All as per Item No 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 2.5 Sqmm copper cable FRLS & 1.5 Sqmm FRLS copper cable for earth continuity wire,complete all as specified and as directed.
20
-
10
S&F sub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface,complete all as specified and as directed. ( NOTE :- Two runs of 2.5 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit.)
200
-
10
Supply and fixi sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 4.0 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping,complete all as specified and as directed.
Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.(Make: RR,KEI and Finolex for copper Cable and Prestoplast/Plaza for casing/conduit)
150
-
10
S&F switch piano flush type 6 Amp single pole one way,complete all as specified and as directed.
70
-
10
S&F socket flush type 6 Amp 5 Pin complete,complete all as specified and as directed.
20
-
10
S&F switch socket combination 5 Pin 6 Amp universal,complete all as specified and as directed.
30
-
10
S&F switch socket combination 5 Pin, 6/15 Amp universal,complete all as specified and as directed.
20
-
10
S&F ceiling rose,3 phase/PVC/Polycarbonate, isolated body,complete all as specified and as directed.
50
-
10
S&F call bell, ding dong AC 230 volts, single pole,complete all as specified and as directed.
5
-
10
S&F bell push, flush type, 5 amp,complete all as specified and as directed.
5
-
10
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
5
-
10
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
6
-
10
S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 240 Volt,4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour, complete all as specified and as directed. (Make: C&S/Hager/Siemens/Legrand)
2
-
10
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA,complete all as specified and as directed. (Make:Hager ,Schnieder or Legrands).9380
2
-
10
M&L for MCB, SP, 240V,40 Amps and ' B ' series breaking capacity 10 KA ISI marked,complete all as specified and as directed.
30
-
10
M&L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked,complete all as specified and as directed.
20
-
10
M&L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked,complete all as specified and as directed.
15
-
10
Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts,complete all as specified and as directed.
10
-
10
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket,complete all as specified and as directed.(Make - Havells Hager/legrand)
5
-
10
S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser, driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
45
-
10
S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
25
-
10
M&L for earthing complete with galvanised steel earth plate electrode (600x600x 6)mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I, complete all as specified and as directed.
8
-
10
Taking down ceiling fan of 1200/1400mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of bush, bearing and marking MES number all as directed by Engr-in-charge.(Note : Bush, bearing , measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in this item.)
250
-
10
Dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling (b)New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable shall be measured and paid separately under relevant item.complete all as specified and as directed by Engr-in-charge.
230
-
10
Supply and fix rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200/1400 mm sweep,complete all as specified and as directed by Engr-in-charge.
70
-
10
Supply and fix bearing number of 6201/6202/6203/6204 as required, Make : SKF/NBC or Eequivalent,complete all as specified and as directed by Engr-in-charge.
90
-
10
Supply and fix condenser 2/2.5 Mfd,complete all as specified and as directed by Engr-in-charge.
110
-
10
Supply and fix PVC holder for condenser housing,complete all as specified and as directed by Engr-in-charge.
150
-
10
Supply and fix twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core,complete all as specified and as directed by Engr-in-charge.
150
-
10
Supply and fix only gun metal bush,complete all as specified and as directed by Engr-in-charge.
80
-
10
Complete painting of ceiling fan by scraping with brush / removing old spray paint with the help of paint remover chemical and spray painting with two coat of synthetic enamelled paint with super glossy finish (grey/brown) with the help of spray painting machine, as directed by Engr-in-chargecomplete all as specified and as directed by Engr-in-charge.
250
-
10
All as per item No. 35 here in before but exhaust fan of size 300 /380 mm sweep.
30
-
10
All as per item No. 35 here in before but exhaust fan of size 400 /450 mm sweep.
20
-
10
Supply and fix condenser 3.15/4 MFD (metal body),complete all as specified and as directed by Engr-in-charge. Make:Universal/Sarda or Equivalent
20
-
10
Supply and fix louvers of exhaust fan 300/380 mm sizes made out of GI sheet of appropriate thickness .Fixing of exhaust fan louvers should be done with the help of anchor fastener nut bolts,Complete all as specified and as directed.
10
-
10
Supply and fix exhaust fan motor AC single Phase. 230V for size 300 mm , 85 watts sweep exhaust,Complete all as specified and as directed.
8
-
10
Supply and fix exhaust fan motor AC single Phase. 230V for size 380 mm sweep , 150 watt exhaust,Complete all as specified and as directed.
8
-
10
Supply and fix exhaust fan motor AC single Phase, 230V for size 450 mm sweep ,400 watts exhaust,Complete all as specified and as directed.
6
-
10
Supply and fix complete frame with side holding clamps with suitable nuts/bolts for exhaust fan 300/380 mm sweep as per existing make/size,Complete all as specified and as directed.
10
-
10
Supply&fix blade made of iron suitable for Exhaust fan 300/380 mm sweep,Complete all as specified and as directed.
10
-
10
Taking down/dismantling of defective/rusted storage type hot water gyser of 50/25 ltr capacity from different locations by disconnecting inlet / outlet connections and taking out unserviceable parts by unscrewing bolts and nuts etc deiscaling / cleaning inner servicing and etc.Checking defects, re-assembling and re-installing the gyser in position, connection and testing,Complete all as specified and as directed.
30
-
10
Supply&fix indication lamp (green/red) as required,Complete all as specified and as directed.
20
-
10
Supply&fix thermostat of range 0-90 degree centigrade as required,Complete all as specified and as directed.
20
-
10
Supply&fix heating element 2 KW (ISI Marked) cup type / thread type with the provision of thermal cut out as required,Complete all as specified and as directed.
20
-
10
Supply& fix inner SS tank of capacity 25 litre,Complete all as specified and as directed.
5
-
10
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for cold water,Complete all as specified and as directed.
40
-
10
S&F hot water pipe for gyser, connection with check nuts and washers,Complete all as specified and as directed.
40
-
10
S&F in replacement of gun metal non return valve of 15mm dia ISI marked,Complete all as specified and as directed.
20
-
10
S&F in replacement of stop cock brass of 15mm dia,Complete all as specified and as directed.
20
-
10
S&F gun-metal, globe or gate valves 15mm dia, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and as directed.
20
-
10
S&F in replacement of GI tubing medium grade 15mm dia with all fittings and fixed to wall, ceiling or roof,complete all as specified and as directed.
30
-
10
Evaluation Notes How It Works ?