Military Engineer Services Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 48,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_659085_2Tender No
8400/1238Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L block masonary transformer platform of size 2.0 mtr x 2.0 mtr with height 1.4 mtr above and 0.60 Mtr below GL consisting of cement concrete in foundation of PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate, PCC block masonary 1:3:6 in CM (1:4), moorum filling and consolidating inside the block masonery work, 100 mm thick sub base concrete with PCC 1:3:6 and 100 mm thick top PCC 1:2:4 type B-2 & 15 mm plaster on side walls in 1:4 CM incl two coats of white wash and providing 2 Nos supporting channel of ISMC 100 of 2.0 Mtr long made of Fe 410 -W (Gde- E- 250) quality- A, complete all as specified and as directed. (Suitable for 250KVA Transformers)
1
-
-
M& L GI tubing medium grade of size 100 mm dia fixed on walls /plateform of transformer as protection pipe for ground cable including provisioning of specials and clamps etc including taking down of old unseviceable pipe any type and any size complete all as speified and directed.Note - Excavation to be paid separately in respective items.
12
-
-
M& L GI tubing light grade of size 50 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc including taking down of old unseviceable pipe any type and any size complete all as speified and directed.Note - Excavation to be paid separately in respective items.
30
-
-
Supply only the chain link fencing MS galvanised fencing of size 50x50 mm thickness not less than 3.00 mm complete all as specified and directed
135
-
-
Fixing only the Chain link fencing on MS picket post including line wires,any mesh, size and type to any type of standards, straining bolts,etc including provision of winding wire complete all as specified and directed
34
-
-
Supply and fixing angle iron made of mild steel confiriming to Fe 410-W (Gde-E 250) quality 'A' of size 50x50x6 mm as in post and stuts in fencing incl cutting top to shape as directed,and flat iron of size 50x6 mm drilling of holes as drected for chain link fencing to angle all as per directed.rate including dismanting to the old PCC fence post complete all as specified. Note - (i) Rates are including required Nut bolts with washers any type any sizes for fixing of chain lik fencing. (ii) PCC for post of picket shall be paid separatelly in respective items.
175
-
-
Material and labour Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, complete all as specified and as directed.
14
-
-
Material and labour for Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in foundation, plinth courses, string courses, lacing courses, parapets with fair surface complete all as specified.
11
-
-
M&L for Precast cement concrete 1:3:6 hollow block type using 16 mm graded aggregate (as per IS 383) masonry exc. 10 cm in width and setting in mortar complete with straight or curved on plan built in 1:6 cement mortor specified and directed.
7.5
-
-
M&L for 15 mm thick rendering/plastering on fair faces of bricks surfaces or concrete surface in CM 1:4 complete and directed.
24
-
-
Supply only the Mild steel round bar 10 mm dia and over conforming Fe 410 - A for fixing to chain link fencing.
45
-
-
M&L for painting with two coat of synthetic enemelled paints over a coat of red oxide including perparation of new steel surface and chain link fencing complete all as specified.Note - Colour of paint will be approved by Engineer in Charge.
60
-
-
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line in soft / loose soil and getting out in soft / loose soil complete all as specified
70
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified & directed
63
-
-
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified & directed.
7
-
-
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long).including two coats aluminium of painting and numbering of poles with one coat red oxide primer including taking down old unserviceable pole all as specified and directed by EIC.
13
-
-
M& L Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for payment.
4
-
-
M&L laying bricks 'B' class over a cable (Width wise) old dried complete all as specified and directed.
0.5
-
-
Supply, laying, testing and commissioning in replacement of HT XLPE cable , insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with staranded aluminium conductor, conforming to IS : 7098 (Part II), 11 KV "E" grade, cross sectional area laid in pipe/ducts/ trenches/ under floor/ under road all as specified of 95 sqmm 3 core including taking down old unserviceable cable all as specified and directed by EIC.
60
-
-
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve, with all fittings/accessories for current rating 200 Amps ,including taking down of only 3 fuses complete all as specified and as directed by Engr-in-charge.
1
-
-
Fabricate supply install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet CPRI approved test type make including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary PCC foundation complete all specified. including taking down old unserviceable LT Panel all as specified and directed by EIC. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable.(2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (a) Main incoming 250 Amps MCCB 04 pole, 25 KA - 01 nos (b) Electrolytic grade aluminium bus bar 400A rating for 3 phase and neutral including PVC colour coded sleves. - 01 Set (c) LED lamps for R,Y,B Phase indication with control fuse/MCB - 01Set
(d) Volt meter digital type 96 sqmm with selector switch - 01 set (e) Amps meter digital type 96 sqmm with CT's 250/5 -03 Nos and selector switch - 01 Set (f) Insulators, wiring, bus bar sleeves, lugs, gland, sheet metal enclosure etc including complete wiring with suitable size of copper wire
1
-
-
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
2
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core
200
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core
250
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 4 core
150
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core
180
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core
200
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core
250
-
-
Supplying & fixing of terminal panel box of size 155 mm x 210 mm x 92mm of outdoor pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler POLYCARBONATE THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. . The manufacturer of board/panel shall submit a copy of test report in accordance with IEC 60529. The Panel Should be assembled at manufactures factory (Make for terminal panel Box - Hensel/hager/Sintex and Panel box having 1x 6 Amp MCB (Make -Indo Asian(optipro /Havells/Legrand), 16 Sq.mm Terminal Block (04 Nos) , 6 Sq.mm Disconnected Terminal (01 No) ,4 Sq.mm Earth Terminal (01 No) including MS clamp flat 20 mm x3 mm in suitable fixed to pole with nut bolts complete.
20
-
-
M& L for Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. to be fixed on pole with all fittings including mouth pieces for passing of sub main wiring three core of copper wire 2.5 sqmm to provide woth conduit and connection to LED light and control box complete all as directed.
60
-
-
M&L in repairs Cable PVC insulated PVC unsheathed un-armoured copper conductor (multi stranded) of cross sectional area 1.5 sq mm 3 core drawing in PVC conduit/Steel tubular pole all as required for connections to light fittings complete all as specified and as directed.
60
-
-
Material and labour for cutting of metallic road/ hard standing/hard rock/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary) complete all as specified and as directed by Engineer-in-charge.Note: 1. If damaged/broken the any type of tiles while removing, the contractor shall replace the broken tiles with new one.2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/measured separately.3. All the removable tiles/re fixable material shall kept carefully at a safe place for refixing with in this quoted rate.4. GI Pipe shall measured and paid separately under relevant item.
12
-
-
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as speified and directed by Engr-in-charge.
11
-
-
Supply and fix lightning arrestor expulsion type HT 11 KV 10 KA complete with all fittings station class, complete all as specified and directed by EIC.
1
-
-
Supply install test and commissioning of LT Panel box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removable MS plates for fixing cable glands for all incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor . the size of busbar box minimum not less than 1500 mm x 150mm x 600mm with 3 Nos cable glands for outgoing (as per CPRI approved manufacturer) incuding necessary PCC foundation as per drawing complete all specified and directed by Engineer-in-Charge. including taking down old unserviceable LT Panel. Note : (i) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (ii) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. (A) INCOMING (a) Aluminium busbar of capacity suitable for 600 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 400 Amps 4 pole 25 KA - 01 No (c ) Volt metre digital type with selector switch - 01 set (d) Amps metre digital type with CT's 250/5 - 03 Nos and selector switch - 01 Set (e) Indicating lamp set LED type - 01 set of three (B) OUT GOING (a) MCCB 250 Amps, 25 KA - 2 Nos (b) MCCB 100 Amps, 25 KA - 2 Nos (c) MCB TPN 63 Amps - 01 Nos
2
-
-
Supply,installation and erection in true vertical or to be planted as strut steel tubular swaged welded two pole structure complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top,poles made out of ERW MS tubing confirming to IS1161 part-II, type 410 SP -31(9.0m long) including drilling of holes of required size and nos for fixing of cross arms/clamps, painting with one coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, painting pole no. with black paint at suitable height complete all as specified and directed.
1
-
-
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%