Military Engineer Services Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671963_1Bid Award Id
ViewTender No
8300/3277/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site etc complete all as specified and directed.
10
-
-
M&L for Brick work using old size bricks ,straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
10
-
-
Taking down cement plaster of brick or stone masonry etc including raking out joints , hacking for key & scrubbing down with water etc and removal of rubbish off from site complete all as directed by Engr-in-Charge.
40
-
-
M&L for rendering 15 mm thick on fair face of brick masonry/concrete surface etc in cement mortar (1:6) surface finished even & smooth without using extra cement complete all as specified and directed.
100
-
-
M&L for 3 mm thick setting coat of cement mortar 1:1 ,trowelled to even and smooth finish over rendering 15 mm thick on fair face brick masonry/concrete surface etc in CM (1:4) surface finished even & smooth using extra cement mixed with using water proffing compound @ 3% by weight of cement complete all as specified and directed.Note:Water proofing compound will be measured and paid seprerately under respective item of "BoQ".
100
-
-
Supply only water proofing compound complete all as specified and directed.
15
-
-
Demolition of plain cement concrete(un-reinforced ) in ground floors, terrazo tiles floor & paving not exceeding 15cm thickness (below or above ground level) and removal of rubbish off from site complete all as directed by Engr-in-Charge.
8
-
-
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-2 (using 40mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
106.67
-
-
Demolition of plain cement concrete (un-reinforced) of any description of any position not otherwise specifically provided for and removal of rubbish off from site complete all as directed by Engr-in-Charge.
8
-
-
M&L Extra for forming fair finished drain or channel to any inner girth in cement concrete, using extra cement including forms, moulds, etc (inner girth only to be measured) complete all as specified and directed.
40
-
-
M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring & mass concrete etc complete all as specified and directed.
30
-
-
M & L for machine pressed cement concrete tiles 25cmX25cm X 22mm thick/ 30 cm x 30 cm x 22 mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment ,laid over and including 15mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
30
-
-
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in levelling course,kerb/ benching/ coping /window cill etc including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed.
2
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
126
-
-
M & L glazed ceramic coloured tiles of size 300 mm x 450 mm x7mm thick/350 mm x 250 mm x7mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
92
-
-
M & L non skid coloured ceramic tiles 7 mm to 8 mm thick (sqaure/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc.,laid over and including 15mm thick screed bed in cement mortar (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed.
34
-
-
S&F in repair vitreous China urinals, bowl flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)(back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe etc.complete all as specified and as directed
6
-
-
S&F WC squatting pan " Orissa Pattern" of size 580 mm X 440 mm white with integral foot rest including cast iron "P" or "S" trap, front or back inlet and making connection to trap & to flushing cistern complete including taking down existing pan & making good disturbed surface complete all as specified & directed.
8
-
-
S&F in repair vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with plastic water closet seat closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
22
-
-
S & F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
30
-
-
S&F repair CP jet spray of standard size for EWC along with CP connection pipe and all fittings complete all as specified and directed.
22
-
-
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
20
-
-
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
16
-
-
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
4
-
-
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing bweinching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required in 150mm internal dia of pipe complete all as specified and as directed.
4
-
-
Demolition and breaking up drain pipes of 150mm dia (SGSW/AC/RCC/PVC) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 100 mtr complete all as directed by Engr-in-Charge.
60
-
-
Demolition and breaking up drain pipes of 200 mm dia (SGSW/AC/RCC) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 100 mtr complete all as directed by Engr-in-Charge.
40
-
-
M & L for Concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed
60
-
-
M & L for Concrete bed to 200 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed
40
-
-
S & F 150 mm bore Reinforced concrete drain pipes of class NP-2 laid and jointed with collars in trenches and jointed complete all as specified and as directed.
60
-
-
S & F 200 mm bore Reinforced concrete drain pipes of class NP-2 laid and jointed with collars in trenches and jointed complete all as specified and as directed.
40
-
-
Removing blockage of or from water closet(Indian or European type)/WHB /Siink /Floor trap/Gully trap upto first manhole ( Indian or European type ) by removing solid/liquid or mud deposited in the trap or CI pipe line by rodding manually and removing the sludge duly covered in a hygenic manner and making the WC (Indian or European type)/WHB/Siink/Floor trap/Gully trap fully functional complete all as specified and as directed by Engr-in-Charge.
1200
-
-
Cleaning of under ground sewage pipe line(cleaning length not exceeding 30 m from man hole or from manhole to septic tank) 100mm dia/bore of pipe by roding and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after clwaning complete as directed by Engineer-in-Charge.
50
-
-
Cleaning of under ground sewage pipe line(cleaning length not exceeding 30 m from man hole or from manhole to septic tank) 150mm dia/bore of pipe by roding and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after clwaning complete as directed by Engineer-in-Charge.
8000
-
-
Cleaning of under ground sewage pipe line(cleaning length not exceeding 30 m from man hole or from manhole to septic tank) 200 mm dia/bore of pipe by roding and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after clwaning complete as directed by Engineer-in-Charge.
100
-
-
Cleaning of septic tank of any capacity and any type of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited /removing the sludge etc outside the MoD land shall be conveyed in closed container and also disposed off in the place properly using bleaching powder etc complete all as directed by Engr - in -Charge. Note: Date of cleaning of Septic Tank with location shall be recorded in MB for record purpose.
82
-
-
Taking down eaves gutter, soil west and vent , rain water pipes (any size or pattern) , including all fittings complete all as specified and directed by EIC.
100
-
-
S & F 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed.
80
-
-
S&F for 110 mm bore PVC(SWR) bends any radius complete all as specified and directed.
16
-
-
S&F for 110 mm bore PVC(SWR) bends any radius with access door jointed with rubber ring joints complete all as specified and directed.
12
-
-
S&F for 110 mm bore PVC (SWR) branch piece pipe single, (Single -Y) equal or unequal complete all as specified and directed.
4
-
-
S&F for 110 mm bore PVC (SWR) branch piece pipe single, (Double -Y) equal or unequal complete all as specified and directed.
2
-
-
S&F in repair 110mm bore PVC(SWR) vent Cowl complete all as specified and directd.
16
-
-
S & F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall/laid in trenches complete all as specified and as directed .
20
-
-
S&F for 75 mm bore PVC(SWR) bends any radius complete all as specified and directed.
6
-
-
S&F in repair 75 mm bore PVC(SWR) vent Cowl complete all as specified and directd.
6
-
-
M&L for cleaning of PVC water storage tank of capacity 1000 ltr on existing bldgs with disconnecting of inlet and outlet pipe ,cleaning with brush/cotton cloth,removing of silt,dirt ,vegetation etc by applying bleaching powder ,lime and washing of water tank and fixed in same position complete all as per specified and directed by Engr-in-charge.
36
-
-
M&L for cleaning of PVC water storage tank of capacity 500 ltr on existing bldgs with disconnecting of inlet and outlet pipe ,cleaning with brush/cotton cloth,removing of silt,dirt ,vegetation etc by applying bleaching powder ,lime and washing of water tank and fixed in same position complete all as per specified and directed by Engr-in-charge.
14
-
-