Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677297_1Bid Award Id
ViewTender No
C/8689/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and laying of CPVC 25mm outer dia pipes of SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors,complete all as specified and directed by Engr in charge.
60
-
10
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and as directed by Engr-in-charge.
5
-
10
Dismantling PVC/cement water tank n. exc. 500 ltrs capacity complete all as specified and as directed.
1
-
10
S&F rotational moulded polyethylene water storage tank triple layered, white colour ( cylindrical vertical with closed top) hoisted and fixed in position of 1000 liters capacity confiring to IS specification,complete all as specified and as directed.
1
-
10
S&F in repairs CPVC Ball valve (gate valve) quarter turned screwed bothe end for CPVC pipe or for union of 25mm dia bore and fixed,complete all as specified and as directed by engr in charge.
5
-
10
S&F in repairs 15mm bore dia Bib taps chromium plated, cast copper alloy with capstan handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs all as specified and as directed by Engr-in-charge.
10
-
10
S&F in repairs for 15mm bore dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed,complete all as specified and as directed by Engr-in-charge.
5
-
10
S&F in repairs for 15mm bore angle Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed,complete all as specified and as directed by Engr-in-charge.
10
-
100
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including
all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles,complete all as specified and as directed by Engr-in-charge.
2
-
10
M&L for Brick work with fly ash bricks straight or curved on plan n. exc. 6m mean radious built in CM(1:6) etc,complete all as specified and directed by Engr-in-charge.
2
-
10
Taking down cement or cement plaster of any description on brick or stone walls or from concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc and removing unserviceable material outside cantt area complete all as specified and as directed by Engr-in-charge.
300
-
10
M&L for Rendering 10 mm thick in CM (1:6) on fare faces of brick surface finished even and smooth without using extra cement etc all as specified (icluding necessay scafolding lifting arrangement for internal surfaces),complete all as specified and as directed by Engr-in-charge.
200
-
10
M&L for Rendering 20 mm thick on other than fair faces of concrete surface of walls, finished in cement mortal (1:4) with even & smooth surface without using extra cement,complete all as specified and as directed by Engr-in-charge.
100
-
10
M&L for applying two coats of cement base paint incl. preparation of new plastered surface, complete all as specified and as directed by Engr-in-charge.
100
-
10
M&L for preparing New plastered or un-plastered surfaces of walls pillasters, cornices etc and applying two coat of destempering 1st quality acrylic distemper (Ready mixed) having VOC content less than 50 gms/liter of approved manufacturer of required shade and colour complete all as per manufacturerer instruction over a coat Birla White Wall Care Putty ( thickness as required at site to make the surface even and smooth) on prepared wall/celling over prepared surface of wall complete all as specified and as per manufacturer’s instruction, complete all as specified and directed by Ensgr-in-charge.
200
-
10
M&L for Non skid ceramic coloured designer seamless tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exc. 0.38 sqm,in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed in CM(1:6), complete all as specified and directed by Engineer-in-Charge.
150
-
10
M&L for Glazed ceramic coloured designer seamless tiles (300x450x7)mm thick on vertical surface as in skirting, dado set and jointed with neat cement slurry and pointed in white or coloured cement to match with the surface over and including 10mm thick screed in CM(1:4), complete all as specified and directed by Engineer-in-Charge.
100
-
10
M&L for Preparation old steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint etc, complete all as specified and directed by Engineer-in-Charge.
100
-
10
M&L for Preparation of old wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint etc, complete all as specified and directed by Engineer-in-Charge.
100
-
10
M&L for preparing old decorated plastered or un-plastered surfaces of walls pillasters, cornices etc two coat of destempering 1st quality acrylic distemper (Ready mixed) having VOC content less than 50 gms/liter of approved manufacturer of required shade and colour complete all as per manufacturerer instruction over a coat Birla White Wall Care Putty ( thickness as required at site to make the surface even and smooth) on prepared wall/celling over prepared surface of wall complete all as specified and as per manufacturer’s instruction, complete all as specified and directed by Ensgr-in-charge.
150
-
10
Demolition of cement concrete (unreinforced) in ground floors and paving's n. exc. 15cm thickness(below or above ground level) and removing unserviceable material outside cantt area,complete all as specified and directed by Engr-in-Charge.
11.5
-
10
M&L for cement concrete (1:2:4) type B-1 (20 mm graded aggregate) of 40mm thick in as in flooring finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
100
-
10
M&L for PCC (1:3:6) type C-2 (40 mm graded stone agg) of 75 mm thick as in plinth protection/Hard standing, finished even and fair complete all as specified and directed by Engineer-in-Charge.
100
-
10