Military Engineer Services Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date23 Dec 2023
Closing DateCancelled
Tender Amount₹ 27,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Item No .01 above but of capacity 75 KVA at 2/5 GR Pump house.

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at Pump House Khojatoli.

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at MI Room 404 AD Khojatoli

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at 1 R&O Flt.

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at Pump House Khojatoli.

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at Power Hose Namkum

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at 2/5 GR Pump House Khojatoli.

6

-

-

... More
All as per Item No .01 above but of capacity 63 KVA at Pump House 404 AD Khojatoli

6

-

-

... More
All as per Item No .01 above but of capacity 35 KVA at Rest camp Pump house/Borewell

6

-

-

... More
All as per Item No .01 above but of capacity 30 KVA at LAO office area

6

-

-

... More
All as per Item No .01 above but of capacity 20 KVA at MAP Qtrs Pump house Khojatoli

6

-

-

... More
All as per Item No .01 above but of capacity 20 KVA at Rest camp Pump house/Borewell

6

-

-

... More
All as per Item No .01 above but of capacity 20 KVA at DID line Pump house/Borewell

6

-

-

... More
All as per Item No .01 above but of capacity 20 KVA at LPH area

6

-

-

... More
All as per Item No .01 above but of capacity 20 KVA at Veer line Pump house

6

-

-

... More
All as per Item No .01 above but of capacity 15 KVA at Tetra Regt Khojatoli

6

-

-

... More
M&L for carrying out scheduled 'B' check of the Diesel Generator Set 250 KVA at Power House namkum including connected alternator and carrying out routine servicing of the engine as per manufacturer's instructions including consumables complete for smooth functioning of the set all as specified and as directed. Note :-(i) Cost of all consumables required during the servicing / maintenance of the DG Set shall be deemed to be included in the rate quoted for these items. (ii) Spare parts, filter elements, engine oil, distilled water and radiator coolant liquid required for replacement during the maintenance period shall be measured and paid seperately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iii) AMF Panel and control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of this item of job and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings.

1

-

-

... More
All as per Item No .20 above but of capacity 250 KVA at Power House Namkum

1

-

-

... More
All as per Item No .20 above but of capacity 81.25 KVA at Power house Namkum

1

-

-

... More
All as per Item No .20 above but of capacity 75 KVA at 2/5 GR Pump house.

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at Pump House Khojatoli.

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at MI Room 404 AD Khojatoli

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at 1 R&O Flt.

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at Pump House Khojatoli.

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at Power Hose Namkum

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at 2/5 GR Pump House Khojatoli.

1

-

-

... More
All as per Item No .20 above but of capacity 63 KVA at Pump House 404 AD Khojatoli

1

-

-

... More
All as per Item No .20 above but of capacity 35 KVA at Rest camp Pump house/Borewell

1

-

-

... More
All as per Item No .20 above but of capacity 30 KVA at LAO office area

1

-

-

... More
All as per Item No .20 above but of capacity 20 KVA at MAP Qtrs Pump house Khojatoli

1

-

-

... More
All as per Item No .20 above but of capacity 20 KVA at Rest camp Pump house/Borewell

1

-

-

... More
All as per Item No .20 above but of capacity 20 KVA at DID line Pump house/Borewell

1

-

-

... More
All as per Item No .20 above but of capacity 20 KVA at LPH area

1

-

-

... More
All as per Item No .20 above but of capacity 20 KVA at Veer line Pump house

1

-

-

... More
All as per Item No .20 above but of capacity 15 KVA at Tetra Regt Khojatoli

1

-

-

... More
Supply only fuel filter elements with 'O' Rings for DG Set of capacity 250 KVA DG set at Power House Namkum

2

-

-

... More
All as per Item No .39 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 39 above but of capacity 75KVA

1

-

-

... More
All as per Item No. 39 above but of capacity 63 KVA.

7

-

-

... More
All as per Item No. 39 above but of capacity 15 KVA to 35 KVA.

8

-

-

... More
Supply only lube /engine oil filter/catridges as per sample and make of the engine at site for 250 KVA DG Set

2

-

-

... More
All as per Item No .44 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 44 above but of capacity 75KVA

5

-

-

... More
All as per Item No. 44 above but of capacity 63 KVA.

5

-

-

... More
All as per Item No. 44 above but of capacity 15 KVA to 35 KVA.

3

-

-

... More
Replacement of Air Filter elements of existing type for 250 KVA DG set.

1

-

-

... More
All as per Item No .49 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 49 above but of capacity 75KVA

5

-

-

... More
All as per Item No. 49 above but of capacity 63 KVA.

5

-

-

... More
All as per Item No. 49 above but of capacity 15 KVA to 35 KVA.

3

-

-

... More
Supply and Filling Engine Oil SAE 15W-40W all as directed. Make- Bosch/Castrol/Indian OIl

185

-

-

... More
M & L for descaling of radiator assy of DG set 250 KVA by disconnecting and removing from eingine, opening the top & bottom chambers, descalling the sediments and scales, corrosion etc and cleaning the core pipes with cleaning chemicals (radi wash) and high pressure water washing and arresting the leakage in core, if any, by brazing / dummy with lead, compressed air cleaning, reassembling the same with new gasket, and fixing to the engine with new hose pipe and clipes as reqd and filling radiator coolent complete all as directed. Note : The rate qouted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges if required . The coolant required for filling will be measred and paid seperately under respective item of this schedule.

2

-

-

... More
All as per Item No .55 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 55 above but of capacity 75KVA

1

-

-

... More
All as per Item No. 55 above but of capacity 63 KVA.

7

-

-

... More
All as per Item No. 55 above but of capacity 15 KVA to 35 KVA.

10

-

-

... More
Supply and replace maintinance free lead acid battery PVC body 12 Volt 180/200 AH Make -Exide/Amaron or equevalent to other make

2

-

-

... More
Supply and replace maintinance free lead acid battery PVC Body 12 Volt 150 AH Make -Exide/Amaron or equevalent to other make

1

-

-

... More
Supply and replace maintinance free lead acid battery PVC body 12 Volt 130 AH Make -Exide/Amaron or equevalent to other make

1

-

-

... More
Supply and replace maintinance free lead acid battery PVC body 12 Volt 100 AH Make -Exide/Amaron or equevalent to other make

1

-

-

... More
Supply and replace fan belts of 250 KVA DG set as per sample all as specified and directed.

1

-

-

... More
All as per Item No .64 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 64 above but of capacity 75KVA

1

-

-

... More
All as per Item No. 64 above but of capacity 63 KVA.

1

-

-

... More
All as per Item No. 64 above but of capacity 15 KVA to 35 KVA.

1

-

-

... More
M & L for disconnecting fuel pump of DG set 250 KVA from the engine, transporting to work shop for checking, servicing and calibration of fuel injection pump / PT pump with injectors of following capacities of DG sets as per calibration procedure and norms specified by OEM guide lines including replacement of wornout injector nozzles, plungers and cups, sealing rings, "O" rings and gaskets as required and refixing to the engine and testing to its full efficieny complete all as specified and as directed by Engr in Charge.

1

-

-

... More
All as per Item No .69 above but of capacity 81.25 KVA.

1

-

-

... More
All as per Item No. 69 above but of capacity 75KVA

1

-

-

... More
All as per Item No. 69 above but of capacity 63 KVA.

1

-

-

... More
All as per Item No. 69 above but of capacity 15 KVA to 35 KVA.

1

-

-

... More
Dismantling/repairing the cylinder head assy for Kirloskar engine of 15 to 30 KVA DG Set by stripping out the head assy from engine and carrying out the machining work such as head surfacing, pressure testing, valve seat angle facing, replacing the rusted water plugs and fixing the new brass water plugs etc and replacing the worn out parts like inlet & exhaust valves guides, valves seat inserts, head gaskets, stem seal, silicon "O" rings and reaasmbling after replacing following spares and testing to its full efficiency including transportation all as directed :- (a) Valve (Inlet & Exhaust) - 6 Pair (b) Valve Guide - 12 Nos. (c) Valve seat - 12 Nos. (d) Stem Seal - 12 Nos. (e) Set of copper washer - 1 set (f) Set of O Ring 1 Set (g) Set of gasket - 1 set. (h) Copper head Gasket -06 nos (b) Valve Guide - 12 Nos. Note :- (i) The rate qouted shall be inclusive of transporting of the head assy to the workshop and back for machining work including all incidental charges. (ii) The rate quoted shall also deemed to be inclusive of all consumables and minor spares required for satisfactory completion of the repair.

1

-

-

... More
All as per Item No. 74 above but of capacity 63 KVA to 250 KVA.

1

-

-

... More
Cleaning throughly and preparing surface by removing rust, dust and oil, and painting of complete DG Set of 250 with two coats of existing colour code including control / AMF panel board complete all as specified and directed by Engr-in-Charge. Note:- (i) Painting should be done with existing colour codes and paint should apply with the help of spary gun using air compressor. 2. Quoated rate shall deemed to be inclusive of preparation of old painted surface and applying zinc chrome primer in patches over rusted portion all as directed.

1

-

-

... More
All as per Item No. 76 above but of capacity 30 KVA to 82 KVA.

2

-

-

... More
All as per Item No. 76 above but of capacity 15 KVA to 20 KVA.

2

-

-

... More
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 250 KVA .

1

-

-

... More
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 30 KVA to 82 KVA .

2

-

-

... More
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 15 to 20 KVA.

2

-

-

... More
Supply only Low Oil pressure Switch 12 V, 1.7 Kg/Sq.mm as per sample.

2

-

-

... More
Supply only multi stranded copper cable of size 20 sqmm single core,Red colour for positive terminal including cutting into pieces in length as per site requirment and also fixing of battery terminal both sides of the cable piece complete all as specified and directed.

6

-

-

... More
All as per per item No. 83 above but black colour (for negative terminal).

6

-

-

... More
Supply only battery terminal made of brass including suitable nut bolts complete for connection both side battery and Self starter of DG set.

2

-

-

... More
Supply only Stoping Solenoid switch/shutt down valve 24 V for 250 KVA Capacity.

1

-

-

... More
All as per Item No. 86 above but of capacity 30 KVA to 82 KVA.

1

-

-

... More
All as per Item No. 86 above but of capacity 15 KVA to 20 KVA.

1

-

-

... More
Supply only Benjo bolts of suitable sizes.

3

-

-

... More
Supply only fuel pipe filter.

4

-

-

... More
Supply only anti vibration pad.

12

-

-

... More
Supply only analog type DC Ammeter of Range 0-10 A.

1

-

-

... More
Supply only Lube oil pressure gauge of suitable range.

1

-

-

... More
Supply only Radiator hose flexible suitable for 250 KVA DG set.

1

-

-

... More
All as per Item No. 94 above but of capacity 30 KVA to 82 KVA.

1

-

-

... More
All as per Item No. 94 above but of capacity 15 KVA to 20 KVA.

1

-

-

... More
Supply only Hose plain for water pump suitable for 250 KVA DG set.

1

-

-

... More
All as per Item No. 97 above but of capacity 30 KVA to 82 KVA.

1

-

-

... More
All as per Item No. 97 above but of capacity 15 KVA to 20 KVA.

1

-

-

... More
Supply only Cotton waster superior quality.

30

-

-

... More
M & L for disconnecting & taking out carefully the Alternator 415 V 50 Hz AC of 30 KVA to 82 KVA DG set from the engine foundation , reassembling & refixing the same after necessary repairs including testing & commissioning etc all as specified & directed. (a) Removing U/S & burnt field coils from stator of alternator & rewinding the same with supper enamelled copper wire of suitable size complete with insulation paper , other required materials spares etc and refixing the same including reconnections all as specified & directed (b) Removing & taking out the U/S ball bearing from rotor shaft & replacing the same with new one of suitable size. (c) Varnishing the armature of the alternator with super class varnish.

1

-

-

... More
All as per Item No. 101 above but of capacity 15 KVA to 20 KVA.

1

-

-

... More
Supply & fix Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 15 KVA to 250 KVA capacity, complete all as specified and as directed.

20

-

-

... More
Supply & fix Cooling Fan (as per existing/ as approved) suitable for DG Set 250 KVA capacity, complete all as specified and as directed.

1

-

-

... More
Supply & fix Cooling Fan (as per existing/ as approved) suitable for DG Set 30 to 82 KVA capacity, complete all as specified and as directed.

1

-

-

... More
Supply & fix Cooling Fan (as per existing/ as approved) suitable for DG Set 15 to 20 KVA capacity, complete all as specified and as directed.

1

-

-

... More
Taking down Exhaust Fan 250 mm to 350 mm Sweep from any type and make of DG set and transporting nearest Workshop for repair/ rewinding , varnising after taking out burnt out wire of any type, Cleaning Slot Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, and fixing to same place as complete all as specified and as directed.

1

-

-

... More
Servicing & preventive maint of Self Starter 24 V assembly of DG set 250 KVA by disconnecting from engine and dismantling the same cleaning all accessories, replace the minor wornout parts like :- brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and reassembling the same,refitting to the engine and testing all as directed.

2

-

-

... More
All as per Item No. 108 above but of capacity 30 KVA to 82 KVA.

11

-

-

... More
All as per Item No. 108 above but of capacity 15 KVA to 20 KVA.

6

-

-

... More
M & L for repairing/rewinding of stator coil of self starter 24 V DC and replacing born out parts such as bushes, bearing, bentex, pinion gear including testing all as directed.

1

-

-

... More
M & L for repairing/rewinding of stator coil of self starter 12 V DC and replacing born out parts such as bushes, bearing, bentex, pinion gear including testing all as directed.

1

-

-

... More
M&L for replacing diesel level indicator hose of existing size including circlip/clamp etc. all as directed.

5

-

-

... More
M & L for carrying out regular checking and repair and maintenance of AMF/Control panel including routing / preventive maintenance checks as required for trouble free functioning of AMF panel for DG set 250 KVA at Puwer House namkum and also replace the born out parts complete all as specified and directed by Engr in Charge. Note-01 :- The following points will be ensured during routine Maintenance:- (i) Checking all electrical connections, all contact points / Bus bars, timers (AC or DC), all type of buttons, selector switches, volt/Amp meter/energy/ PF/ KWH meters/CT's, indicator lamps, main/ auxliary contacts/relays, contact coils, replace ,volt /amps/Auto / manual function, tightening of screws and bolts, battery charger , Cleaning the panel. Note-02 :- (i) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for these items.

6

-

-

... More
All as per Item No .114 above but of capacity 250 KVA at Power House Namkum

6

-

-

... More
All as per Item No .114 above but of capacity 81.25 KVA at Power house Namkum

6

-

-

... More
All as per Item No .114 above but of capacity 75 KVA at 2/5 GR Pump house.

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at Pump House Khojatoli.

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at MI Room 404 AD Khojatoli

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at 1 R&O Flt.

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at Pump House Khojatoli.

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at Power Hose Namkum

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at 2/5 GR Pump House Khojatoli.

6

-

-

... More
All as per Item No .114 above but of capacity 63 KVA at Pump House 404 AD Khojatoli

6

-

-

... More
All as per Item No 114 above but of capacity 35 KVA at Rest camp Pump house/Borewell

6

-

-

... More
All as per Item No 114 above but of capacity 30 KVA at LAO office area

6

-

-

... More
All as per Item No 114 above but of capacity 20 KVA at MAP Qtrs Pump house Khojatoli

6

-

-

... More
All as per Item No 114 above but of capacity 20 KVA at Rest camp Pump house/Borewell

6

-

-

... More
All as per Item No 114 above but of capacity 20 KVA at DID line Pump house/Borewell

6

-

-

... More
All as per Item No .114 above but of capacity 20 KVA at LPH area

6

-

-

... More
All as per Item No .114 above but of capacity 20 KVA at Veer line Pump house

6

-

-

... More
All as per Item No .114 above but of capacity 15 KVA at Tetra Regt Khojatoli

6

-

-

... More
Supply only relay 12 V DC. Make : PLA 8/11 Pins suitable for AMF Panel.

1

-

-

... More
Supply only HRC fuses of capacity 4-20 Amps.

2

-

-

... More
Supply only HRC fuse cartidge assembly both base and top 20A rating.

1

-

-

... More
Supply only indicator lamps DC filament type

1

-

-

... More
Supply only indicator lamps AC 230 Volt LED Type for the panel boards.

1

-

-

... More
Supply only push button with contact element 5 A with NO-NC

1

-

-

... More
Supply only Selector switch for Voltmeter and Ammeter.

1

-

-

... More
Supply only PVC connectors 6 to 10 ways heavy duty suitable for AMF panels.

1

-

-

... More
Supply only Ampere meter as per sample of range 0-30/50/100 Amps AC for control/AMF panel

1

-

-

... More
Supply only Volt Meter as per sample of Range 0-500 Volts AC.

2

-

-

... More
Supply only Frequency meter vibrating reed of Range 45-55 HZ. Model 13 REEDS

1

-

-

... More
Supply only Frequency meter blinking type LED type of Range 45-55 HZ. Model 13 LEDS

2

-

-

... More
Supply only B series electronic timers model BIDCA-X adjustable cyclic function 240 Volts AC or as per siteand suitable to AMF panel.

2

-

-

... More
Supply only '' ON DELAY TIMERS (for STOP/START/LOP/LOT/FAULT etc) Time range 3 sec to 30 hours contact 5 Amps 240V/12-24 volts DC or as per sample complete all as specified and directed.

1

-

-

... More
Suuply only GS timer (T45 GS) suitable to fit in existing place . Make and model as per sample.

1

-

-

... More
Supply only GC Timer (T45GC) as per sample.

1

-

-

... More
Supply only main contactor 4P for AMF panel model MCX 41, 325 Amps for 250KVA DG set.

1

-

-

... More
Supply only main contactor 4P for AMF panel model MCX 33, 200 Amps for 75/81.25KVA DG set.

1

-

-

... More
Supply only main contactor 4P for AMF panel model MCX 22, 100 Amps for 30 KVA DG set.

2

-

-

... More
Supply only main contactor 4P for AMF panel 40 to 60 Amps, make L & T/Siemens or as per sample suitable to fix in existing place for 20 KVA DG set.

1

-

-

... More
Supply only auxiliary /control contactors of suitable contactor (2NO, 02NC) of suitable ratings for AMF Panel. As per site requirement or all as specified and directed.

2

-

-

... More
Supply only voltage monitering regulator (UV, OV, SP) of suitable ratings for AMF panels

1

-

-

... More
Single phase preventer

12

-

-

... More
M&L for drain out the diesel from the diesel tank of any type/capacity and removing all rust, dirt, sludge and sedimentation in the tank and clean thoroughly using suitable detergent, refilling the diesel to the tank of 250 KVA DG set all as specified and directed.

2

-

-

... More
All as per Item No. 156 above but of capacity 63 KVA to 81.25 KVA.

9

-

-

... More
All as per Item No. 156 above but of capacity 30 KVA to 35 KVA.

2

-

-

... More
All as per Item No. 156 above but of capacity 15 KVA to 20 KVA.

6

-

-

... More
Supply and fix on load change over switch of capacity 630 Amps, 4 pole , 415V in sheet steel/metal enclosure conforming to IEC 60947-3 ,door interlocking , suitable for vertical/horizontal with frame made of equal angle iron of size 40 x 40 x 6 mm, making all fixing arrangement and grouting in PCC foundation of 1:2:4 type B1 with following accessorries complete all as specified and as directed. Make : Legrand/ L&T/Indo Asian. (i) Extra Spreader Links for frame to be provided as per suitable size of change over switch enclosure - 1 set (4 Nos links). (ii) Extra Auxiliary Switch 200A (1NO + 1NC) suitable for change over switch - 1 set (4 Nos links) Note :- 1. Cost of Items are required for fixing and extra accessories of change over switch and taking down old shall be includes in items rates.

1

-

-

... More
Supply and fix on load change over switch of capacity 400 Amps, 4 pole , 415V in CRCA sheet steel/metal enclosure conforming to IEC 60947-3 ,door interlocking , suitable for vertical/horizontal with frame made of equal angle iron of size 40 x 40 x 6 mm, making all fixing arrangement and grouting in PCC foundation of 1:2:4 type B1 with following accessorries complete all as specified and as directed. Make : Legrand/ L&T/Indo Asian. (i) Extra Spreader Links for frame to be provided as per suitable size of change over switch enclosure - 1 set (4 Nos links). (ii) Extra Auxiliary Switch 200A to 630A (1NO + 1NC) suitable for change over switch - 1 set (4 Nos links) Note :- 1. Cost of Items are required for fixing and extra accessories of change over switch and taking down old shall be includes in items rates.

1

-

-

... More
Supply and fix on load change over switch of capacity 250 Amps, 4 pole , 415V in CRCA sheet metal enclosure conforming to IEC 60947-3 ,door interlocking , suitable for vertical/horizontal with frame made of equal angle iron of size 40 x 40 x 6 mm, making all fixing arrangement and grouting in PCC foundation of 1:3:6 type B1 with following accessorries complete all as specified and as directed. Make : Legrand/ L&T/Indo Asian. (i) Extra Spreader Links for frame to be provided as per suitable size of change over switch enclosure - 1 set (4 Nos links). (ii) Extra Auxiliary Switch 200A to 630A (1NO + 1NC) suitable for change over switch - 1 set (4 Nos links) Note :- 1. Cost of Items are required for fixing and extra accessories of change over switch and taking down old shall be includes in items rates.

1

-

-

... More
Supply and fix on load change over switch of capacity 200 Amps, 4 pole , 415V in CRCA sheet metal enclosure conforming to IEC 60947-3 ,door interlocking , suitable for vertical/horizontal with frame made of equal angle iron of size 40 x 40 x 6 mm, making all fixing arrangement and grouting in PCC foundation of 1:2:4 type B1 with following accessorries complete all as specified and as directed. Make : Legrand/ L&T/Indo Asian. (i) Extra Spreader Links for frame to be provided as per suitable size of change over switch enclosure - 1 set (4 Nos links). (ii) Extra Auxiliary Switch 200A to 630A (1NO + 1NC) suitable for change over switch - 1 set (4 Nos links) Note :- 1. Cost of Items are required for fixing and extra accessories of change over switch and taking down old shall be includes in items rates.

2

-

-

... More
S&F MCCB 400 Amp with rupturing capacity 36 KA ,4 pole , 415 Volts, 50 Hz thermal magnetic release, fixed type complete with sheet steel enclosure frame for MCCB mounted on frame made of equal angle iron of size 40x40x6 mm, making all fixing arrangement and grouting in PCC foundation of 1:2:4 type B1 cpmplete all as specified and directed. Make : Legrand/ Schneider/Indo Asian . Note :- (1) Spreader Links 1 set (4 Nos links) in suitable size/ capacity for MCCB 400A and Cables and lugs to be provided as per suitable as per size of sheet enclosure shall be includes in items rates. 2. Cost of Items extra accessories for fixing of MCCB shall be includes in items rates. (3) Rates of lugs and glands for incoming and out going of LT UG cable shall be includes in items rates.

2

-

-

... More
S&F MCCB 250 Amp with rupturing capacity 25 KA ,4 pole , 415 Volts, 50 Hz thermal magnetic release, fixed type complete with CRCA sheet enclosure frame for MCCB mounted on frame made of equal angle iron of size 40x40x6 mm, making all fixing arrangement and grouting in PCC foundation of 1:2:4 type B1 cpmplete all as specified and directed. Make : Legrand/ Schneider/Indo Asian . Note :- (1) Spreader Links 1 set (4 Nos links) in suitable size/ capacity for MCCB 400A and Cables and lugs to be provided as per suitable as per size of sheet enclosure shall be includes in items rates.2. Cost of Items extra accessories for fixing of MCCB shall be includes in items rates. (3) Rates of lugs and glands for incoming and out going of LT UG cable shall be includes in items rates.

1

-

-

... More
M&L for providing earthing complete with GI earth plate electrode of size 60 cm X 60 cm X 6 mm thick burried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 25 x 4 mm galvanized MS strip by means of bolts, nuts check nuts and washer of GI or steel all as shown in electrical plate No.5 of SSR Pt-I, connected to earthing main switch board/main board including necessary earthwork PCC 1:3:6 type C-1 chamber, precast RCC cover using XPM weighing not less than 4.00 Kg/Sq m in lieu of CI cover, 20 mm bore GI pipe (light grade) for watering and 40 mm bore GI pipe (light grade) for protection of earth lead test point terminal block made of bronze of size 75x75x25 mm drilled and screwed including 03 Nos 8 mm 25 mm long Hex head screw etc complete all as specified and directed.

8

-

-

... More
M&L providing earthing complete with Copper earth plate electrode of size 60 cm X 60 cm X3.15 mm thick burried directly in ground, earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level, connected to20×3mm copper strip as earthing lead by means of bolts, nuts check nuts and washer of GI or steel all as shown in electrical plate No.5 of SSR Pt-I, connected to earthing main switch board/main board including necessary earthwork PCC 1:3:6 type C-1 chamber, precast RCC cover using XPM weighing not less than 4.00 Kg/Sq m in lieu of CI cover, 20 mm bore GI pipe (light grade) for watering and 40 mm bore GI pipe (light grade) for protection of earth lead test point terminal block made of bronze of size 75x75x25 mm drilled and screwed including 03 Nos 8 mm 25 mm long Hex head screw etc complete all as specified and directed.

8

-

-

... More
M & L for Copper strip 20 x 3.15mm with connection to earth for grid provide under ground/ above ground of earthing and test point etc conductors and down conductors above ground.

80

-

-

... More
S&F of GI tubing light grade of size 40 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified.

18

-

-

... More
S&F of GI tubing light grade of size 80 mm dia fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed.

12

-

-

... More
M&L XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed of size 185 Sqmm 3 ½ core (Make - Polycab cable/Havells/KEI) and laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.

62

-

-

... More
All as per item No- 171 here in before of size 3 ½ core 120 Sqmm complete all as specified and directed.

120

-

-

... More
All as per item No- 171 here in before of size 3 ½ core 95 Sqmm complete all as specified and directed.

110

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for wall /pole foundation ssembly and getting out in hard/dense soil.

60

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm all as specified.

26

-

-

... More
Removal of excavated soil to a distance not exceeding 50M and depositing at a level not exceeding 1.5 meter above starting point all as specified.

22

-

-

... More
M &L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenchesas per SSR part-I. ii) For the purpose of measurement punned thickness only will be considered for paymet.

18

-

-

... More
M&L for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed.

1.8

-

-

... More
Supply and fixed the metal Barrel (Drum) of capaicty 200- 220 ltrs in 1st Quality suitable for storage of diesel for DG set installed at certain location as directed by Engr-in-Charge.

10

-

-

... More
Supply and fix the Hand Rotary barrel pump made of cast iron with suction tube rigid type with length 1000 mm long and 25 mm outlet made of cast iron with and tube/ pipe in length of 1500 mm long in suitable size of 25 mm outlet complete all as directed.

2

-

-

... More
Taking / lifting out defective submersible type raw sewage pumps set of capacity 1/1.5 HP, 1500 RPM from raw sewage sump with column pipe steel rope, submersible cable and accessories, including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and relowering the same after repairing works including replacement of worn out parts as per requirement and testing complete all as directed.

1

-

-

... More
M&L for rewinding of submersible type sewage motor 1/1.5 HP, 1500 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc. including cleaning and replacement of defective parts complete all as directed.

1

-

-

... More
Taking out defective Air blower with motor of capacity 3 KW/5 HP, 1500 RPM complete with all accessories, including cleaning, greasing,oiling of bearing of electric motor and refixing , including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and commissioning the same after repairing works including replacement of bearing and testing complete all as directed.

2

-

-

... More
M&L for rewinding of Air blower motor of capacity 3 KW/5 HP, 1500 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc. including cleaning and replacement of defective parts and painting of steel and iron surfaces with one coat of synthetic enemelled paint after preparation of old painted surfaces complete all as directed.

2

-

-

... More
Supply and replacement of air filter for air blower of capacity 3 KW/5 HP as per existing pattern/make all as directed.

2

-

-

... More
M&L for cleaning raw sewage chamber and cleaning all foreign materials all as directed.

12

-

-

... More
M&L for draining out sewage water from Fludized Aerobic Bed (FAB)/MAB reactor and cleaning and washing the same and inlet /outlet pipes complete all as directed .

12

-

-

... More
M&L for drain out sewage water from Tube settler tank and cleaning and washing the same and inlet /outlet pipes complete all as directed .

12

-

-

... More
M&L for drain out sewage water from treated water tank and cleaning and washing the same and inlet /outlet pipes complete all as directed .

12

-

-

... More
M&L for cleaning of bushes shrubs, grass around out side of STP upto 2 meter between fencing & road complete . Note : Necessary tools for cleaning will be arranged by the contractor with out any extra cost.

2000

-

-

... More
M&L for plastic filter media for enhanced bacterial development in filter tank used in STP plant as directed .

100

-

-

... More
Removing of dried sludge from sludge drying bed and depositing the same at a distance of not less than 200 mtr from plant all as directed.

12

-

-

... More
Supply and filling of oil ENKLO 320 or equivalent for air blower of capacity 3 KW all as directed. Make- Servo/Valvoline /BPL

80

-

-

... More
M&L for testing of treated water of STP (Monthly/quarterly) from authorised laboratory and submit the report timely complete all as directed. Make - Bharat test House/CIMEC/Spectro or equivalent lab approved by GE.

8

-

-

... More
S&F in replacement of DOL Starter 3 Ph for capacity suitable for 1.5 HP submersible motor pump complete all as specified and directed

1

-

-

... More
Dismantling and repair of starter panel of centrifugal motors of any capacity complete all as specified and directed. Note : material used/replaced in panel will be measured and paid seperately.

1

-

-

... More
M&L in replacement of ball valve 50mm GI complete all as specified and directed

2

-

-

... More
Supply only 'V' belt suitable for functioning of air blower moter pump 5 hp as per existing (sample provided) complete all as specified and directed

6

-

-

... More
Reapir/rewiring of control panel of STP by cleaning inside/outside and around the panel, checking and tightening of all incoming and outgoing connections and replacing aluminium lugs, replacement of burnt wires of existing size as required to make it functional complete all as specified and as directed. Note :- Any other spare required for replacement shall be measured and paid under relevent item of BOQ as supply & rate of fixing is deemed to be included under this item (Item No. 8 (a) to 8 (o))

1

-

-

... More
Supply only Auxiliary power Contactor Model No LC1D1 or (as per existing/sample provided, for making proper connection with suitable lugs all as per directed by Engr-In-Charge.Make-L&T/Siemens/Legrand/Schneider

6

-

-

... More
Supply only Auxiliary power Contactor Model No LC1D12 or (as per existing/ sample provided) for making proper connection with suitable lugs all as per directed by Engr-In-Charge.Make-L&T/Siemens/Legrand/Schneide

4

-

-

... More
Supply only power Contactor Model No LRD-12 or (as per sample provided) for making proper connection with suitable lugs all as per directed by Engr-In-Charge.Make-L&T/Siemens/Legrand/schneider

4

-

-

... More
Supply only power Contactor Model No LC1D or ( as per sample provided) for making proper connection with suitable lugs all as per directed by Engr-In-Charge.Make-L&T/Siemens/Legrand

4

-

-

... More
Supply only power Contactor Model No LD or (as per sample provided) for making proper connection with suitble lugs all as per directed by Engr-In-Charge.Make-L&T/Siemens/Legrand

4

-

-

... More
Supply only MCB 415 volts 32-40 Amp 4 pole, C type including connectiuon with suitable size almuminium/ copper lugs in repairs complete all as specified and directed. Make- Legrand/L&T/Simens/schneider

4

-

-

... More
Supply only MCB SPN 240 volts 16 Amp 3pole C type including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/L&T/Siemens/schneider

2

-

-

... More
Supply only MCB SP 240 volts 6 Amp C type including connection with suitable size aluminium / copper lugs complete all as specified and directed. Make- Legrand/L&T/Siemens/schneider

2

-

-

... More
Supply only single phase preventor making proper connection with suitable lugs all as per directed by Engr-In-Charge. Make-L&T/Siemens/Legrand/schneider

3

-

-

... More
Supply only connector plate making proper connection with suitble lugs all as per directed by Engr-In-Charge.

8

-

-

... More
Supply only Phase indicator(RYB) lamp LED type making proper connection with suitble lugs all as per directed by Engr-In-Charge.

3

-

-

... More
Supply only ON/OFF push button switch making proper connection with suitble lugs all as per directed by Engr-In-Charge.

10

-

-

... More
Supply only Multi function meter of 50 Hz , 240 volt complete all as specified and directed. Make- Legrand/L&T/Siemens/schneider

2

-

-

... More
Supply only digital timer switch suitable for connecetion or as per sample provided to make functional existing control panel all as specided and directed Mke :L&T/Siemens/Legrand/schneider

2

-

-

... More
M&L for earthing complete with galvenised steel earth plate electrade 600 x 600 x6 mm thick buried directly in ground (earth pit not less than 2.5 m deep below GL) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts check nuts and washers of GI all as shown in electrical plate No-5 of SSR Pt-I work includes for necessary excavation earth work PCC pit and RCC cover, funnel with salt ,charcoal dust, water pipe line 20 mm & protection pipe 40 mm, wire mesh complete all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.