Indian Oil Corporation Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Indian Oil Corporation Limited - IOCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Dec 2024
Closing Soon1 Jan 2025
Tender Amount₹ 13,74,685.66 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PPLC Policy, PPE Matrix, NDMA Clause
General Conditions of Contract
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Solid State Diode Decoupling Device (min 5 kA @ 30 cycles) of approved make including required length of cable as per specifications

2

71890

84830.7

... More
Supply of Zn Grounding cells (with prepackaged backfill material) including required length of cable (minimum 10 m) of approved make & as per specification in accordance with latest revision of drawing no. 9200-99900-404-611-01 (STD-570-01) Grounding Cells

1

21320

25157.95

... More
Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings Spark Gap Surge Arrestor for above ground and under ground suitable for 100 kA lightening Impulse Current (10/350 micro s), rated spark over voltage = 1.25 kV in flameproof weatherproof enclosure Ex d IIC, IP 66 with connecting cable (EXFS 100 KU of Dehn or eq.)

1

13583

16028.34

... More
Junction Box having IP-42 degree of protection; Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc.

1

14260

16827.21

... More
Flameproof & weatherproof Anode Junction Box of approved make; Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc.

1

15543

18341.16

... More
Supply of Flameproof & weatherproof CJB with accessories; Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc. Supply of Flameproof & weatherproof CJB with accessories for distribution of current among pipelines as per technical specification.

1

21682

25585.02

... More
Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as given in technical specifications DC distribution board with one incomer, 100 A DP MCB & outgoing feeders 1x63A DP MCB & 2x32 A DP MCB

1

23720

27989.71

... More
Supply of Cu- Cuso4 Permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make

2

9344

11025.92

... More
Supply of Cu- Cuso4 portable Half cell, as per specifications of approved make

1

5711

6739.82

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 1cx50 sq. mm Armoured

1

529

624.44

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 1cx35 sq. mm Armoured

50

414

489.12

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 1cx25 sq.mm Armoured

50

248

292.97

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 2cx6 sq.mm Armoured

50

179

211.66

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 2cx25 sq.mm Armoured

1

582

687.75

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make; Copper Cable size 2cx70 sq.mm Armoured

1

608

718.17

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make Copper Cable Kynar/HMWPE size 1cx10 sq.mm Unarmoured for distributed anodes of station CP system

50

192

227.17

... More
Supply of Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40%

-

-

-

... More
CU,2CX2.5 mm²,2XWY

50

63

75.51

... More
CU,3CX2.5 mm²,2XWY

1

93

110.4

... More
CU,3CX4 mm²,2XWY

1

126

149.15

... More
CU,2CX10 mm²,2XWY

1

168

199.05

... More
Supply of Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40%

-

-

-

... More
AL,3CX10 mm²,A2XFY

50

79

94.12

... More
AL,4CX16 mm²,A2XFY

1

96

114.45

... More
AL,3CX25 mm²,A2XFY

1

120

142.45

... More
AL,3.5CX25 mm²,A2XFY

1

123

146.3

... More
AL,3.5CX35mm²,A2XFY

1

162

191.51

... More
AL,3.5CX50 mm²,A2XFY

1

193

227.74

... More
AL, 3½C x 95 mm²

1

329

389.27

... More
AL,3½C x 120 mm²

1

408

482.58

... More
AL, 3½C x 185 mm²

1

647

763.72

... More
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Power cables LT : OD upto 20 mm

150

35

41.5

... More
Power cables LT : OD above 20 mm and upto 40 mm

1

50

59.59

... More
Power cables LT : OD above 40 mm and upto 60 mm

1

80

95.21

... More
LT CABLE END TERMINATION FOR ARMOURED/ PVC INSULATED ALUMINIUM CABLE WITH SINGLE COMPRESSION BRASS GLANDING (INCLUDING COST OF GLANDS & LUGS) Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding single compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent), wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge.

-

-

-

... More
2 x 6 sqmm

50

271

320.95

... More
3 x 10 sqmm

50

304

359.45

... More
3 x 16 sqmm

1

326

384.76

... More
3 x 25 sqmm

1

328

387.71

... More
3 x 35 sqmm

1

390

460.64

... More
Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.

2

7340

8662.2

... More
Installation of grounding cells including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of grounding cell etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.

1

5754

6790.72

... More
Installation of surge arrestors including terminating the cables, testing & commissioning of surge arrestors etc. all complete with required material as per specification and directions of Site Engineer / Engineer-in-Charge.

1

7387

8717.45

... More
Installation of Permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cable, testing & commissioning of cell etc. all complete with required material, excavation, backfilling etc. as per specifications, recommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge.

3

8445

9965.1

... More
Coating Resistance Survey: Conducting " Coating-Resistance Survey" for calculation of specific coating resistance of the pipeline in ohms.sq.m. along the entire pipeline and submitting the report in hard as well as soft copy as per Specification / approved procedure and directions of Site Engineer / Engineer-in-Charge.

1

1733

2045.91

... More
Close Interval ON/OFF Potential logging survey: Conducting Close Interval Potential Logging Survey at an interval of 1 m over the buried line in the right of way including the cost of all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 3 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge.: Close Interval ON/OFF Potential logging survey

8

4278

5048.97

... More
Direct Current Voltage Gradient Survey: Conducting Direct Current Voltage Gradient Survey over the buried line, logging all measurements, to identify / pin point the coating defects on pipeline including the cost of all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 3 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects as per directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contractor, who will arrange to repair the defects.

8

4970

5864.6

... More
Soil Resitivity Survey: Conducting "Soil Resistivity Survey" at anode bed location after ascertaining its suitablity with respect to the existing system , for installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer / Engineer-in-Charge.

8

10268

12116.54

... More
AC interference survey: Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line (33 KV and above) crossing or running parallel within a distance of 60 M from the pipeline alignment as per approved procedure. The work shall be completed in all respects including survey, data logging for specified period, recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations.

16

13077

15431.83

... More
Mutual Interference Survey: Conducting Mututal Interference Survey among the new and existing pipelines / facilities /foreign pipeline by taking PSP survey of all the pipelines as per approved procedure to determine level of interference at different places along the pipeline and at point of crossing in common ROW including identifying points and providing the data/ record in graphical form and carrying out all necessary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remedial measures undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphs in 3 sets.The item should be complete in all respect including survey, work for mitigating the interference and post mitigating survey as per specifications/directions of site engineer / Engineer-in-Charge.

1

8291

9783.85

... More
CAT Survey: Carrying out the Current Attenuation(CAT) Survey at 50 meters interval by measuring current loss along the mainline pipe and using Radio Detection Instruments. Completing the entire work as per specification and EIC`s direction including all equipments with its accessories etc.tools, tackles, Battery transportation (Vehicle), related equipments ,consumables, if any labour /manpower and any / all relevant data collection as may be deemed necessary for carrying out the survey and interpretation /presentation of the results including submission of reports complete in all respect thereof. Also locating the exact position of buried pipeline/defect of Pipeline coating.Route mapping of the entire stretch at an interval of 10M with the help of GPS instrument (to be arrange by contractor)and submission of the hard and soft copy to the EIC.

5

6836

8066.93

... More
Installation of CJB / AJB as per technical specifications.

2

17822

21030.14

... More
Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and all other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank

1

4034

4760.95

... More
ANODE INSTALLATION: Installation, testing & commissioning of owner supplied MMO/ZN/MG/Hi-Si anode. work includes excavation of well type trench up to depth of 4 m from ground level, laying of owner supplied prepacked MMO/ZN/MG/Hi-Si anode at depth of 4 M , filling the pit with muddy soil, coke breeze in layers before and after laying of the anodes in the trench, backfilling the trench with the loose earth already excavated as per the drawing & direction of site engineer. Supply of Salt & pet coke is in the scope of contractor. Laying of anode cable is not included in this item scope. Transportation of anodes form owners site to instaltlion site is in the scope of contractor.

5

8797

10380.88

... More
Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including its tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings.

5

8868

10464.79

... More
Cable Marker: Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all materials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge.

5

1046

1234.61

... More
Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 7.6 Kg each) including its tail cable of size of 1c x 6 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings.

5

8481

10008.67

... More
Type A (With Ingress Protection IP:55): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

5

16355

19298.94

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for PSP Measurment): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

1

20035

23642.15

... More
Type B (With Ingress Protection IP:55): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

15

39380

46469.3

... More
Type C (With Ingress Protection IP:55): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

5

24201

28557.66

... More
Type D (With Ingress Protection IP:55): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

5

18682

22045.65

... More
Type DAC (With Ingress Protection IP:55): Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

5

30937

36506.05

... More
Flameproof Type E (With Ingress Protection IP:55) as per specification: Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

1

48189

56863.33

... More
Flameproof Type DMV (With Ingress Protection IP:55) as per specification: Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

1

42292

49905.01

... More
Repair of the existing Test Lead Points in our Right-of-Way including supplying of all the required materials and making good the defects so as to complete the TLPs in working condition in accordance with the drawing for the following missing items/faults and as per the instructions of the Site Engineer /Engineer-in-Charge.(a)Providing & welding missing TLP Covers with locking arrangements and allen keys.

5

2250

2655.45

... More
Repair of the existing Test Lead Points in our Right-of-Way including supplying of all the required materials and making good the defects so as to complete the TLPs in working condition in accordance with the drawing for the following missing items/faults and as per the instructions of the Site Engineer /Engineer-in-Charge.(b)Providing & welding missing TLP Box with Covers having locking arrangements with allen keys,5mm thick bakelite sheets,10mm dia. brass bolts,(c) Excavating the TLP upto the bottom of outlet of 2.5Sqmm PVC insulated cables,removal of the faulty cables,Providing & jointing new cables ,connecting to the 5mm thichk bakelite sheet and commissioning the TLPs in working condition omplete as per the instructions of the Site Engineer/Engineer-in-Charge.

5

3142

3708.06

... More
Supplying, Fabrication and installation of vandal proof test lead point (RCC) (TLP) of 6" dia. of cement concrete mix of 1:2:4 including supply of proper size of lug, washer & brass nut bolt, Bakelite in sulation plate, 2 inch dia GI pipe (B class, lSI marked) of 1.5 mtr length threaded at one end to fit the vandal proof TLP Box & other end with bend pipe connection witha piece of GI pipe taking out from foundation for cable entries as per the sketch, movement of TLPs at various locations along the ROW, installation of same at site after earth excavation cast at site PCC (1:2:4) work, Backfilling the soil inclusive of supply, punning, painting with synthetic enamel paint. It also include end plug/cap drilling of holes thread cutting, fitting of washer insetting Bakelite sheet grouting the TLP (PCC 1:2:4) making electrical connection with 2 X 6 mm2 PVC copper wire between TLP by thermit welding/pin-brazing technique. The job complete in all respect as per drawing including material labours and as per direction of Engineer-in-Charge.

25

11320

13358.21

... More
CAD welding/Pin brazing of the cable/wire with piepline: The job is inclusive of thefollowing: (a) Excavation upto pipe depth, Preparation of the Cable and Pipeline for CAD welding/Pin brazing(b) Proper CAD welding/Pin brazing of the Cable with the Pipeline Trench (c) Encapsulation of the CAD welding/Pin brazing Pipeline portion (d) Checking holidqay on the pipeline, backfilling. The job is also inclusive of all necessary labour ,sundry materials and accessories required to carry out the job in aproper manner and shall be carried out to the complete satisfaction ofthe Engineer-in-Charge/ Site Engineer (Here ''EA'' means CAD welding/Pin brazing of one/two TLP cable/wire on respective pipeline)

5

5277

6227.95

... More
Supply and Installation of prefabricated CS corrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead in a sdistance of 0.5 m from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion couponf are to be installed with specified test lead points for which prior apporval to be obtained from owner. The item also incluseds supply, installation, laying & termination of all CU cables of required length (as per site condition) and size as mentioned in the standard drawing, toggle switch, cable glands and lugs etc. , complete in all respect as per the direction and specification detailed in the documetn complete with all tools , takles & other necessary requirement for preparation of the coupon . The work complete in all respect shall include supply of all the labours, tols etc. compete as per the direction of site engineer/engineer in charge.

2

6182

7295.13

... More
Preparation & installation of corrosion coupon from owner supplied coated pipe. which involves preparation of sample of size 2"x4", application of pipeline coating material on the coupon, soldering 6 sq. mm. cable with coupon, sealing the soldered joint with epoxy, positioning the coupon at the pipe line depth and with in a distance of 0.5 M from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement for preparation of the coupon. The work complete in all respect shall include supply of all labour, tools etc complete as per the directions of the Site Engineer.

2

2316

2733.05

... More
Supply, installation, testing and commissioning of two separate 4-20 mA converters(0-20 mV Input, 0 to-2VDC input respectively, 2x4-20 mA Output in each converter) in pre installed TLPs at SV/IPIG/CP locations as per the approved drawings and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

1

9286

10957.65

... More
Providing and operating items for attending the job at site, as per job requirement & at IOCL's descretion.One day shall be of 8 hours duration of uninterrupted availability for continuous usage of the d eployed service, i.e. for the first Eight hours or part thereof from the time of deployment - contractor shall be paid amount equal to one day. (i.e. 1 equipment day = 8 hrs of deployment and availability for contnuous usage). The working hours shall start from the time of deployment at site.. This will be inclusive of Operational Charges (Fuel, Consumables, Operator etc whatsoever is required for intended operational at site); Job is to be carried out as per Tender Document and as per Instruction of EIC. Any additional deployment beyond Eight (8) hours, shall be paid extra as additional proporationate Day, and shall not be liable for any short of overtime / payment in any form. (i.e. for deployment of any sort of following services for a period of 10 hours in a day, same shall be paid as 1.25 Days (For items below)

-

-

-

... More
Portable DG Set: Providing Portable DG set (5 KVA) for 230 volt power supply for lighting / buffing / grinding / UT / X-ray etc. including mobilisation and demobilisation charges, Operator, fuel etc for continuous functioning of the same at site

1

7180

8472.7

... More
Halogen / focus set: Providing and temporary installation of Halogen / focus set with 30 mtr. Extension cabel including spare lamp 1000 watt for illumination of working area

1

718

847.24

... More
Providing & operating JCB for earth work in excavation in both ordinary & Rocky soil for ROW cleaning, washout rectification/ installation ofanode ground bed, sacrificial anodes, cable trenches, pipelinetrenches, etc. including backfilling the same after completion of workin all respect and up to the satisfaction of Site Engineer / EIC & thecost includes all labour, materials complete as per direction of SiteEngineer/ EIC.

1

1708

2016.3

... More
SITE GRDAING: Surface dressing (cleaning, levelling, stripping etc whatsoever to make approachable access for movement of machinaries at intended site) of the ground including removing vegetation and in - equalities not exsceeding 30 cm deep and siposal or fubbish, lead upto 50 m and lift upto 1.5 m - All kinds of soil surface, as per job requirement & directions of Engineer-in-charge.

1

14

17.57

... More
Supplying & fixing of fencing: Supplying & fixing GI chain link fencing (for CP station/AJBenclosure/MOV) of approx. size 3" x 3" diamond shape (10 guage) withhorizontal GI wire (8 SWG) at top & bottom for fixing chain link to existing structures including necessary clamps, cleat, painting, all labour & material etc complete as directed by Site Engineer/Engineer-in-Charge.

1

747

882.57

... More
Removing the existing fencing: Removing the existing chain link fencing (in CP/ Anode JCB/ MOV stationenclosure) winding in bundles, transporting and stacking in stores asdirected by Site Engineer/ Engineer-in-Charge inclusive of labour, tools& tackles etc.

1

189

223.19

... More
Earth work in excavation in all kinds of soil, both wet & dry condition (except hard rock requiring blasting, chiselling / pneumatic drilling) for foundation, substructures, trenches, sumps, pits etc. to the following depths including shoring, strutting, trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including bailing out of water (if any), stacking selected excavated earth for backfilling, filling available excavated earth in trenches, foundation, plinth etc. and/or disposing the excess earth outside IOCL premises to an unobjectionable area with all leads & lifts, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer/EIC.

-

-

-

... More
Excavation Up To 2.5 M - All kind of soil except hard rock (Measured from original ground level)

1

300

355.14

... More
Excavation B/w 2.5 M to 5 M - All kind of soil except hard rock

1

541

639.36

... More
Hard Rock Removal - Excavation and backfilling in hard rock (requiring blasting chiselling / pneumatic drilling) dewatering if required, consolidating the trench bed, as per drawing and/or the direction of the EIC.

1

1039

1226.02

... More
Manual excavation (restricted area without the use of JCB) in all type of soil including hard murrum for exposing existing pipeline , bottom clearance including keeping top layer of soil seperately, shoring, shuttering, stacking of soil, followed by backfilling of the trench . The contractor shall properly compact the backfilled earth & restore the RoW to original condition as per the direction of EIC/site engineer.

1

493

581.82

... More
Flood coating by R-95 Powercrete Liquid epoxy paint (Consisting Part A & Part B mixed in ratio as per manufacture recommendation over mainline pipe/ leak clamp/ sleeve etc. including surface preparation as per tender specification & application of liquid epoxy paint (Powercrete R-95) over finished surface. The cost includes all materials( liquid epoxy R-95) consumables, labour etc. The thickness of flood coating shall be 900-1000 micron.

1

7358

8682.82

... More
Laying, Spreading of Morrum for Road Diversion: Laying, Spreading of Morrum by deployment of all required machinaries, tools, manpower, whatsoever for making Road Diversion as per job requirement and as per IOCL's requirement.

1

215

254.17

... More
Road Cutting Cutting bituminous or water bound macadam road, stacking the material and making good the same as previous including supply of extra quantityof aggregate, moorum grit and bitumem etc. required, disposal of surplus earth if any/ complete as per the description of EIC. Job includes supply of all labour, equipments etc.

1

683

806.57

... More
Providing Hydra ( 10-12 TON capacity ) along with belts, chains, hooks etc at site for shifting heavy material or equipments like pipes, welding machine, cold cutting machine etc.The rate is inclusive of mobilisation and demobilisation cost, hiring and running cost, fuels, consumables, lube oil cost, operator cost etc., as per direction of EIC. Payment towards equipment running charges shall be made only if payments are not covered in any of the SOR items elese where in this contract. (1Day= 08 hours of continuous operation of hydra)

1

6763

7981.13

... More
Supplying, fabricating and erecting including embedding in RCC / PCC inposition MS structural steel section such as angle, tees, channels ,beams and ther standard sections, painting two coats of synthetic enamel paint of 25 microns DFT each over a coat of Red Oxide steel primerof 25 micron DFT including cleaning the surface of mill scales, rusts,oil, grease and weld slags etc. by hand cleaning, welding as per IS BOO ,including the cost of all materials, ransportation, welding, labour ,tools, tackles, consumables, power etc. complete in all respects as per specifications and directions of Engineer-in-charge/ Site Engineer. Item shall be paid for in Metric Tone.

-

-

-

... More
Members fabricated from rolled steel sections/ plates/ strips etc. form an hole covers, gates, grills and other items

1

149031

175857.08

... More
Welding, erection, fabrication of IOC supplied steel structure.

1

56751

66966.83

... More
Supply and fixing of Reinforcement with TOR steel bars for RCC work including cutting, straightening, bending, placing inposition and binding complete in all respect Item includes supply, transportation of all requisite material, manpower, tools and tackles at site

1

106

125.93

... More
Finishing Boundary Walls with Water Proofing Cement paint: The work includes Exterior finishing of station walls including boundary walls with water proofing pre mixed cement paint (colour shade to be specified by E-I-C) of reputed make and shade to give an even shade at old work with minimum one or more coats with one coat of cement primer. Item include rubbing/ Scrapping the surface to remove old cement paint before applying the paint to the surface and watering to make good the durability of applied paint. The item includes cost of Material and Labour & associated transportation required for completing the jobs inall respects.

1

95

112.44

... More
Painting walls: Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm

1

155

183.37

... More
Grass cutting / cleaning / housekeeping of at Sectionlizing valve (SV) & cathodic protection(CP) station including transportation, labour, material charges etc. The SV & CP locations are all along the cross counrty pipeline under Barauni Unit

-

-

-

... More
Grass cutting / cleaning housekeeping of at Repeater cum Cathodic protection station (RCP) or Cathodic Protection location where building and or brick masonry boundary is available including transportation, labour charges etc. Note: RCP/CP shall include overall area covered inside the boundary of RCP premises.

4

3041

3588.78

... More
Grass cutting / cleaning housekeeping of at Sectionalising Valves/CP stations (other than those present inside RCP/CP premises, where building and or brick masonry boundary is NOT available)

6

2584

3049.6

... More
Pest Control:

-

-

-

... More
Providing Pied Piper services/Rodent control service for Pest control (House mouse, Root rat, Norway rat, Bandicoot, Mosquitoes, Cockroaches, Ants etc.) Monthly Once in Control Building, Store Building ,Maintenance Building, Sample room in open area inside station premises, RCP/CP stations etc. including all materials, manpower, tools and tackles etc and as per Site Engineer/EIC. (Here "EA" means per RCP/CP/SV/T Point per event)

10

3320

3918.27

... More
Providing Snake Pro services in and around RCP/CP, Pump stations etc. (Here "EA" means per RCP/CP/SV/T Point per event)

10

2182

2575.47

... More
Providing and fixing of Aluminium composite panel of overall 04 mm thickness (Make: Eurobond/Alstone/Aludecor or equivalent) for various display inside station as well as mainline including all labour,tools and tackles & consumables for fixing of ACP board on metallic structure as per direction of EIC/Site Engineer. Payment for structural item is not included in this item.

50

112

133.06

... More
Supply and sticking of good quality and durable reflective sticker of required sizes and shapes for display board/direction marking/equipment tagging etc. on wall/pipe surface/metalltic display board/ACP sheet as per direction of EIC/Site Engineer. Payment for structural item/ACP sheet is not included in this item.

50

65

77.03

... More
Supply and sticking of good quality and durable vinyl sticker of required sizes and shapes for display board/direction marking/equipment tagging etc. on wall/pipe surface/metalltic display board/ACP sheet as per direction of EIC/Site Engineer. Payment for structural item/ACP sheet is not included in this item.

50

32

38.52

... More
Supply and fixing of good quality vinyl printed sunboard of various sizes and shapes including supply of all tools tackles and consumables like screws, screw plug/sleeve gitti etc for fixing of sunboard on wall of station as well as mainline SV stations as per direction of EIC/Site Engineer.

50

59

70.54

... More
HDPE Earthfilled bags: The work includes Providing and laying in position empty HDPE/GSM Based cementbags (Good condition & with filled material load bearing strength)filled cement bags after sewing the bag, including placing ,handling, watering as directed by Engineer-In-Charge at washout sites along the pipeline

1

33

39.12

... More
Painting of sign boards of all sizes, including surface preparation ,minimum two coats of ready mixed synthetic enamel paint of reputed/approved brand to give an even shade over a coat of red oxide primer. Cleaning with wire brush, surface preparation, applying two coats of approved synthetic enamel paint and re-Iettering on the markers inclusive of ransportation, cost of paint, labour, tools and tackle complete as per direction of Site Engineeer/ Engineer-in-Charge. (The item includes cost of material and labour required for painting and re-lettering complete)

-

-

-

... More
Test Lead Points (TLPs)

32

746

880.68

... More
Cutting ,Trimming of branches of Trees,Big plants, Bushes etc. as per direction of Engineer in Charge

1

54

63.81

... More
Painting / Lettering Works on steel or other metal surface at height up to 10 m, with best quality Primer and Paint, including smoothening surface by sand papering etc. Complete with All Materials, Labor, Tools, Equipment

-

-

-

... More
Removing loose scales,blisters etc from old painted surface by scrapping with wire brush thoroughly and smoothening the surface to make it suit- able for receiving fresh coat of paint

1

10

12.52

... More
Application of one coat ready mixed oil based red oxide zinc chromate primer

1

26

31.77

... More
Application of Two or more coats of any shade of Synthetic Enamel Paint

1

107

127.09

... More
Application of Two or more coats of any shade of Aluminium Paint

1

64

76.53

... More
Painting of Cathodic protection / Valve (HOV & MOV) fencing enclosure & doors including removal of dust, grease, rust, loose scales, surface preparation etc., and applying two coats of synthetic enamel paint / Aluminium paint over a coat of suitable primer inclusive of transportation, cost of paint, primer, labour, tools and tackcle complete as per direction of Site Engineeer / Engineer in Charge. Size of enclosure : 3.5 m x 3.5 m and hieght 3.5 mtr. (Silver)

1

7130

8414.41

... More
PAINTING WORK ON ELECTRICAL EQUIPMENTS

-

-

-

... More
PAINTING OF ELECTRICAL EQUIPMENTS: Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of paint by spray painting on electrical equipment/ structures/ poles or any other metallic surface with two coats of approved brand and manufacturer Aluminium paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and materials as per directions of the EIC.

1

209

246.93

... More
WRITING WORK ON ELECTRICAL EQUIPMENTS

-

-

-

... More
Lettering with black Japan paint of approved brand and manufacture including supply of all material & labour and transportation etc Note : Unit of measurement is considered EACH which is equal to per cm height per letter.

10000

4

5.65

... More
Re-lettering with black Japan paint of approved brand and manufacture. Note : Unit of measurement is considered EACH which is equal to per cm height per letter.

10000

3

3.59

... More
Dewatering Pump: The work includes Pumping out of water caused by rains, broken watermains/ drains etc. including supply of pump-motor, necessary labour ,disposal of rubbish etc. (Minimum capacity of Pump 3 HP)

1

274

323.38

... More
Supplying the Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark; as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges.

1

3087

3643.13

... More
Supply and installation of 11/6.6 KV Discharge Rod; as per directions of Site Engineer / Engineer-in-Charge complete in all respects including transportation charges.

1

8903

10506.14

... More
INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per specifications: Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)

1

2720

3210.53

... More
Erection & installation of FLP & WP Distribution Board: Erection, installation including within site transportation, testing and commissioning of 415 V , Flameproof distribution boards (FLP-DB) under scope of supply of bidder, assembling as required, installation on the already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power , control cables, installation of thermistor controller, internal wiring, earthing of FLP-DB panels, supply of cable glands etc. complete as per cable schedule, drawings etc.

1

80

94.91

... More
GI cable tray: Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

1

191

225.52

... More
Aluminium cable tray: Supply, installation & fixing of prefabricated perforated Aluminium cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

1

584

689.57

... More
SAND FILLING: Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

1

840

991.73

... More
BRICK SOLING: Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

1

866

1022.23

... More
LT Cable joint (1.1 KV) - Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Power cables LT : OD upto 20 mm

1

4748

5603.81

... More
Power cables LT : OD above 20 mm and upto 40 mm

1

5788

6829.85

... More
HT Cable Termination (6.6/11 KV) - Supply, termination and connection of XLPE cable termination kit HT Cable of size upto 3Cx240 sq. mm

1

21251

25076.98

... More
Earth electrodes/ Earth Pit: Supplying, installation, testing of GI earthing electrode, including the supply and installation of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per drawings,specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects.

1

15966

18840.22

... More
CHEMICAL EARTHPIT: Supply, installation, testing and commissioning of ACE (Artificial concept of earthing with chemical rod) Chemrod earthing electrode by digging earthing Item includes the supply and installation of the CI/RCC cover in the earth pit, backfilling etc. and construction of chamber; complete including excavation, backfilling and supply of all materials required for making earth pit as per drawings, specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects.

1

17242

20346

... More
EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect:

-

-

-

... More
50 mm X 6 mm G.I. earthing strip

1

288

340.16

... More
40 mm X 5 mm G.I. earthing strip

1

201

238.02

... More
25mm x 4 mm copper flat

1

782

923.57

... More
25mm x 3 mm copper flat

1

714

843.3

... More
GI wire (8 SWG)

1

64

76.29

... More
GI wire / rope 35 sq. mm

1

140

165.42

... More
GI wire / rope 10 mm diameter

1

169

200.23

... More
Copper cable as per specifications - 10 Sq.mm

1

193

228.01

... More
Supplying & putting following back fill materials around Earth electrode/CP Anode Bed etc. as per the instructions of Site Engineer including the back fill materials, transportation tosite, labour etc. (For items below)"

-

-

-

... More
COKE BREEZE (4-10mm size)

1

82

97.13

... More
BENTONITE POWDER

1

12

14.83

1

12

14.83

... More
CHARCOAL

1

51

60.65

... More
GYPSUM

1

12

14.49

... More
Supply and pouring of water around anodes/scrap rails in anode bed, sacrificial anodes and earthing as directed by site engineer

1

103

121.98

... More
Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of site engineer / Engineer-in-Charge:

-

-

-

1

968

1142.28

... More
100 mm

1

1792

2115.56

... More
FLP/WP EXHAUST FANS: Flame proof, weather proof, single phase, 12" exhaust fan, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007, IP65, LM6 type EF1001 of FCG or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects

1

10183

12016.06

... More
FLP/WP ROTARY SWITCH: Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects.

1

5980

7057.21

... More
Lighting Distribution Board / AC Distribution Board - Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings:

-

-

-

... More
Type VI Light DB: Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links along with 1 x 6 A MCB SPN , 7x2 A SPN MCB, Digital time switch , 110 - 240 VAC 1 Phase - 2W, 1 C/O, Base/DIN based upon Lat/Long setting of location working according sunrise and sunset and MNX 9-2P Power Contactors 9 A 2 Pole 1 NO or 1 NC of L&T or equivalent.

1

14000

16521.07

... More
Flush mounting Plug & Socket DB complete with 20 A SP MCB, with neutral link for incoming supply from portable DG set at independent MOV locations.

1

6325

7464.66

... More
Lightining Arrestor: Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the main earthing grid.

1

4850

5723.2

... More
Supply, installation, testing and commissioning of ceiling fans of Bajaj/Crompton Greaves/Khaitan/Usha make only including supply and fixing of the electronic regulators with all necessary supports. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge.

-

-

-

... More
1200 MM SWEEP (WHITE)

1

2581

3046.5

... More
Supply, installation, testing and commissioning of single phase , Fresh Air Fans / Heavy duty Exhaust Fans of Bajaj/Crompton Greaves/Khaitan/Usha make only including supply and fixing with all necessary supports All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge.. NOTE: Necessary civil works required for fixing the exhaust fans shall be in the scope of Contractor.

-

-

-

... More
FRESH AIR FAN WITH LOUVER SHUTTER 400MM SWEEP

1

2337

2757.79

... More
Supply and installation of 125A, TPN, L&T make / equivalent approved switch fuse unit in sheet steel enclosures with suitable HRC fuses as incomer to distribution board including structures and accessories. All complete with labour and materials as per directions of Engineer-in- Charge.

1

7448

8789.64

... More
Supply and installation LED Light Fittings rated for 240V, 50Hz, 1-ph AC: Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SYSKA/Oreva/Crompton or equivalant Indian make). Item includes Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc.

-

-

-

... More
9W, LED Tube Light Fitting, 2FT, 230V AC

1

219

259.35

... More
15W, Outdoor LED Light Fitting, IP55, 230V AC

1

460

543.34

... More
40W LED Light/Lamp, 230V AC, 50Hz

1

1127

1331.02

... More
09W, LED Bulb/Lamp, 230V AC, 50Hz

1

62

73.7

... More
15W, LED Bulb/Lamp, 230V AC, 50Hz

1

152

180.03

... More
LIGHTING CONTROL

-

-

-

... More
Supply, installation,testing and commissioning of occupancy sensor based on PIR technology-non regulated programmable

1

4617

5448.69

... More
Supply, installation,testing and commissioning of astronomical time switch (Electronic Timer) for single phase supply with 1 output per phase

1

3722

4392

... More
Supply and fixing of following size of PVC conduit alongwith the accessories in surface including cutting the wall and making good the same in case of recessed, conduit as required: Note: Only ISI marked conduits shall be used.

-

-

-

1

76

90.06

1

82

97.26

1

155

183.97

... More
Supplying and fixing of following rating 240 volts, 50Hz, 10KA, 'B' Curve, miniature circuit breacker (suitable for lighting and other domestic loads and conforming to IS 8828:19) of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp/equivalent make shall be used as per direction of Engineer-in-Charge.

-

-

-

... More
Supplying 240 volts, 50Hz, 10KA, 'B' Curve, circuit breacker 5 To 32 Amp

1

208

245.95

... More
Supplying 240 volts, 50Hz, 10KA, 'B' Curve, circuit breacker 40 Amp

1

389

459.02

... More
Supplying and fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA 'C' curve, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp or equivalent make shall be used as per direction of Engineer- in-Charge.

-

-

-

... More
Single pole

1

213

251.78

... More
Double pole

1

634

748.7

... More
Triple pole

1

928

1095.89

... More
Four pole

1

1398

1649.89

... More
Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachking and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg

1

1613

1903.62

... More
Supply, fixing and connection of following equipments in panels including small mechanical works and supply of all fixing materials. All complete with labour and materials as per the direction of Engineer-in-Charge

-

-

-

... More
Control contactors- 4 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MX0 of L&T or equivalent

1

1333

1573.74

... More
Power Contactor (with 1NO + 1NC)- Upto 25 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Type MNX25 of L&T or equivalent

1

1707

2014.85

... More
Power Contactor (Upto 2NO + 2 NC)- Above 25 Amp but upto 45 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Type MNX45 of L&T or equivalent

1

6427

7584.27

... More
Power Contactor (Upto 2NO + 2 NC)- Above 45 Amp but upto 140 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Type MNX140 of L&T or equivalent

1

16055

18945.56

... More
Power Contactor (Upto 2NO + 2 NC)- Above 140 Amp but upto 400 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz Type MNX400 of L&T or equivalent

1

29519

34832.54

... More
Supply led indication lamp upto 40v. Operating voltage: Supply and fixing of led indication lamp in the panels. leds shall be provided with leakage voltage protection upto 40v. Operating voltage shall be 110V / 220V / 230V /AC /DC, Panel cutouts shall be 22.5 / 25.5 / 30.5 mm. Terminals shall be shrouded for finger proofing and safety are with captivated washers to hold two lugged (fork / pin) wires in one terminal. Job includes supply of labor and various undry materials required and finally testing of led's for + following ed's

-

-

-

... More
Red / yellow / amber / green / Blue/ milky white led's

1

142

167.56

... More
Supply of following rating and breaking capacity 3 pole MCCB with thermomagnetic release alongwith terminal spreaders as per direction of Engineer-in-Charge.

-

-

-

... More
100 Amps, 16kA

1

3813

4499.98

... More
125 Amps, 16kA

1

4234

4996.96

... More
Supply of following rating and breaking capacity 4 pole MCCB with thermomagnetic release along with terminal spreaders as per direction of Engineer-in-Charge.

-

-

-

... More
100 Amps, 30kA

1

7788

9190.58

... More
125 Amps, 36kA

1

7892

9313.13

... More
Supply of Spare coil for contactors of following type as per direction of Engineer-in-Charge:

-

-

-

... More
L&T ML1.5, Cat No. SS90873 or equivalent

1

777

917.62

... More
L&T ML2/3, Cat No. SS90545 or equivalent

1

1298

1531.77

... More
L&T MNX70, Cat No. CS94192 or equivalent

1

1557

1838.11

... More
Supply of three phase digital ammeter, 0-1000A, 1/5 A,Class- 0.5, 240VAC aux supply as per direction of Engineer-in-Charge.

1

1357

1601.87

... More
Supply of Three phase digital voltmeter, Class-0.5, 240VAC aux supply as per direction of Engineer-in-Charge.

1

1157

1365.8

... More
Supply of SMPS, Input 230VAC, Output 12VDC, 2A

1

1601

1890.09

... More
Supply of HRC, DIN type fuse link of following rating & size

-

-

-

... More
20-32 Amps, Size 000

1

223

263.48

... More
50 Amps, Size 000

1

240

283.5

... More
63 Amps, Size 000

1

264

311.85

... More
125 amps, Size 00

1

349

411.89

... More
125 Amps, Size 1

1

491

580.34

... More
Supply of HRC bolted type fuse links

-

-

-

... More
2-16 Amps, L&T HG type, size F1 or equivalent

1

40

47.67

... More
20-32 Amps, L&T HG type, size F1 or equivalent

1

47

55.6

... More
20-32 Amps, L&T, HQ type, size A1L or equivalent

1

76

90.57

... More
4-32 Amps, L&T, HQ type, size A2 or equivalent

1

67

79.45

... More
35-63 Amps, L&T, HQ type, size A3 or equivalent

1

96

114.4

... More
Supply of accessories for transformers

-

-

-

... More
Supply & replacement of OTI as per direction of Engineer-in- Charge.

1

8234

9716.71

... More
Supply & replacement of Buchholz relay as per direction of Engineer-in-Charge.

1

10293

12145.88

... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 750gm silicagel as per direction of Engineer-in-Charge.

1

828

977.75

... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-Charge.

1

1006

1187.26

... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-Charge.

1

1479

1745.98

... More
Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge.

1

370

436.72

... More
Supply of ms chequered plates of 5mm thickness: Supply, installation and fixing of ms chequered plates of 5mm thickness. job includes cutting to size, supply of hinges / hooks for lifting, tag welding with support wherever required, painting including supply of paint, supply of all material and labor complete in all respect

1

94

111.09

... More
PCC: Providing and laying Plain Cement Concrete 1:3:6 by volume (1 cement: 3 coarse sand: 6 coarse aggregate of specifications given below) for all depths below and upto plinth level in foundations, fillings, non-suspended floors, pavements and ramps etc. including tamping, ramming, vibrating, curing, shuttering etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed; complete with all labour, materials, tools and tackles, consumables, transportation etc.; all as per specifications and directions of the Engeer-in-charge.

-

-

-

... More
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).

1

6276

7406.34

... More
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size).

1

6143

7249.46

... More
RCC: Providing and laying reinforced cement concrete 1:2:4 (1 cement :2 coarse and : 4 coarse Aggregate as specified below) ure of all types, e.g. foundations, footings, rafts, beams, columns, plinth beams, slabs, pile caps, retaining walls, trenches, equipment/machine foundations, pedestals, stair cases etc. including providing pockets, openings, recesses, chamfering etc. where required, tamping, vibrating to achieve proper compaction, curing and rendering, if required, to give a smooth and even surface etc. all complete for all depths below and upto plinth level, in any shape, position and thickness, as per drawings, specifications and directions of the Engineer-in- charge with cost of all labour and materials complete but excluding the cost of centering, shuttering and steel reinforcement. With cement issued at Issue Rates from Owner's Stores, including transportation from Stores to work site and returning all excess/ unused cement to Owner's Storage point after completion of work.- Crshed Stone chips 20 mm and down gauge.

1

7296

8609.34

... More
Providing and laying smooth Cement Plaster with cement mortar of proportion and thickness specified below, on RCC/PCC/Masonry works etc. in walls, ceilings etc., including preparation of base, raking of points, making drip moulds, scaffolding upto any height, rounding the corners, curing etc. with all labour and materials complete, as per drawings, specifications and directions of the engineer-in-charge

-

-

-

... More
15 mm thick plaster with Cement Mortar 1:6 (1 Cement: 6 Fine sand)

1

291

343.55

... More
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in Cement Mortar 1:6 (1 cement : 6 coarse sand) laid to proper position line, level as per drawing/direction including providing necessary scaffolding, staging, raking out of joints, curingetc. complete in all respects inclusive of cost of all labour,materials, tools, tackles etc. as per drawings, specifications anddirection of Site Engineer.

1

5794

6837.97

... More
Contractor Profit over Hire Charges for Labour for emergency works (Unit EA means per labour per day of shift of 08 hours.)

25

78

92.39

... More
Pick up van/Utility vehicle 2-wheel drive with Fuel, operator for Transportation (of owner's material) within range of 100 Km of pipeline length/ROW as per direction of EIC. Payment will be made per trip (to & fro). (Here "EA"means per trip (to & fro) of vehicle within the range of 100 KM)

1

4434

5233.24



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.