Drinking Water And Sanitation Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Drinking Water And Sanitation Department - DWSD Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Jul 2021
Closing Date8 Jul 2021
Tender AmountRefer Documents
Costs
EMD
₹ 12,900Document Cost
₹ 1,250Tender Fee
Refer Documents
Summary
Dwsd/skl/retro/04/2021-22 (group-11) (2nd Call)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_DWSD_50201_1Bid Award Id
ViewTender No
DWSD/SKL/RETRO/04/2021-22 (Group-11) (2nd Call)Tender Authority
Drinking Water And Sanitation Department ViewPurchaser Address
-Website
http://https://jalshakti-ddws.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion- BCD-5.3.2
0.38
-
3729
... More
Distribution
-
-
-
... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10
-
-
-
... More
63 mm HDPE Pipe-
5
-
148.94
... More
50 mm HDPE Pipe-
50
-
93.65
... More
32 mm HDPE Pipe-
600
-
38.31
... More
20 mm MDPE Pipe-
1005
-
23
... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).DSR 18.17.5
-
-
-
... More
50 mm dia .
1
-
776.07
... More
65mm dia
1
-
1328.66
... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10
1
-
5152.82
... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. MJP 19-20 sec-I-IX sl no -2(i)
-
-
-
... More
Distribution Main
-
-
-
... More
63 mm HDPE Pipe-
5
-
41
... More
50 mm HDPE Pipe-
50
-
34
... More
32 mm HDPE Pipe-
600
-
21
... More
20 mm MDPE Pipe-
1005
-
11
... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post. DWSD Sl. 9K (including CP+OHC)
67
-
100.1
... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. DWSD 3.1.2(i)
67
-
12.49
... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I. DWSD 3.1.13
-
-
-
... More
(1) Elbow
-
-
-
... More
(a) 15 mm dia.
134
-
72.77
... More
(2) Reducer Socket -
-
-
-
... More
(a) 20 x 15 mm dia.
67
-
77.25
... More
(3) Nipple -
-
-
-
... More
(a) 15 mm dia.
134
-
71.88
... More
(4) Plain Socket -
-
-
-
... More
(a) 15 mm dia.
134
-
77.59
... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram. (JOSR DWSD 3.1.4.1)
67
-
561.74
... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I. DWSD 3.1.5.2
67
-
177.21
... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I. DWSD 3.1.12
-
-
-
... More
32 mm dia and weight not less than 700 gms.
1
-
711.87
... More
50 mm dia and weight not less than 1.5 Kg.
1
-
1370.36
... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.DSR 18.32.1
1
-
1412.9
... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I. (As per Annexure II Attached)
67
-
1071
... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.
502.18
-
86.32
... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.
67
-
54
... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
-
-
-
... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.
-
-
-
... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
-
-
-
... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
-
-
-
... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
-
-
-
... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.
-
-
-
... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
-
-
-
... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
-
-
-
... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
-
-
-
... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
-
-
-
... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
-
-
-
... More
x) The motor pump set should have a 5 years warranty.
-
-
-
... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
-
-
-
... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
-
-
-
... More
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
-
-
-
... More
xiv) With third party inspection before dispatch.
-
-
-
... More
xv)Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.
-
-
-
... More
The following details should be marked indelibly on the motor pump set
-
-
-
... More
a) Name of the Manufacturer or Distinctive Logo.
-
-
-
... More
b) Model Number.
-
-
-
... More
c) Serial Number.
-
-
-
... More
Solar submersible motor pump (SPV DC Type)
-
-
-
... More
2 HP (DC Pump) with 1800 WP (minimum) as per MNRE.Head Max Shut-off head 100 mtrs.
1
-
170820
... More
Provision of solar night lamp.
1
-
1000
... More
Operation & Maintenance of Distribution Pipeline & House connection for 5 years
1
-
4901.05
... More
GST @12 %
1
-
68256.78
... More
L Cess @ 1%
1
-
6370.63
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements