Central Coalfields Limited Tender
... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 4,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CCL_327337_1Bid Award Id
ViewTender No
PE(EnM)/Rel/e-NIT/24-25/22Tender Authority
Central Coalfields Limited ViewPurchaser Address
-Website
http://http://www.centralcoalfields.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring of 60 Mt WB cabin, Supply and fixing of load cell SPD (surge protection device) and Early streamer emission for lighting protection of 60 MT WB of Religara Colliery
Rewiring of 60 Mt WB cabin, Supply and fixing of load cell SPD (surge protection device) and Early streamer emission for lighting protection of 60 MT WB of Religara Colliery
BOQ Items
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
20
3882
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
30
3882
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
8
3882
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
8
3882
-
... More
supplying and fixing brass batten/angle holder including connection etc. as required.
11
3882
-
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
5
3882
-
... More
Supplying and fixing piano type stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
3882
-
... More
supplying and fixing 5 amps to 32 amps rating,240/415 volts, 10 KA,"c" Curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing,commisioning etc. as required. Single pole and neutral
8
3882
-
... More
supplying and fixing 5 amps to 32 amps rating,240/415 volts, 10 KA,"c" Curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing,commisioning etc. as required . (i) DP 32 Amp
1
3880
-
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp.
2
3881
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way Double Door
2
3882
-
... More
Supply ,installing,testing and commissioning of following capacity TPN Main Switch made of 1.6 mm thick sheet steel enclosure duly painted with powder complete with TPN disconnector fuses,connections,earthig etc. as required. (i) 63 Amp
1
3882
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
4
3882
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
36
3882
-
... More
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.(2.7m x 1m x 1m =2.7 cum, 2.7Cum. x 4= 10.80 Cum))
10.8
3882
-
... More
Supply and Fixing of Load Cell Surge Protection Device
1
3882
-
... More
Supplying and Fixing of 6 sqmm x 2 core multistranded PVC insulated copper Conductor for Service Connection.
30
3882
-
... More
Supply and Fixing of Early Streamer Emission of 45 degree Protection,ISI marked
1
3882
-
... More
Supply and Fixing of Surge Protection Type I 40KA max P+N
2
3882
-
... More
Supply and Fixing of Single Core 6 Sqmm Multi Stranded PVC insulated Copper Conductor,ISI marked
15
3882
-
... More
Supplying and Fixing of 1/2" Metallic Flexible Pipe
300
3882
-
... More
Total impact of GST for the purpose of CTC