Central Coalfields Limited Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 2,49,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CCL_308998_1Bid Award Id
ViewTender No
GM(KTA)/SO (C)KTA /e-Tender/24-25/05 dtd 23.05.2024Tender Authority
Central Coalfields Limited ViewPurchaser Address
-Website
http://http://www.centralcoalfields.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering,etc. and disposing of surplus excavated soil as directed, within a lead of 50 m Pipes, cables etc. exceeding 300 mm dia. but not
exceeding 600 mm dia
682.5
323505
474
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 150mm dia rcc pipes
3672.5
1429924
389.36
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 450 dia rcc pipes
682.5
536083
785.47
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
98.06
17033
173.71
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size).
77.71
407970
5249.91
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
32.67
238702
7306.46
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement, 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
120.66
899766
7457.04
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
10.42
76215
7314.33
Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns
79.8
19337
242.33
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc
555.37
274236
493.79
Centering and shuttering including strutting, propping etc. and removal of form work for Columns, piers, abutments, pillars, posts and struts
33.88
20190
595.94
Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access
platform
59.53
33622
564.8
Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers
3.96
1803
455.46
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
9882.05
849065
85.92
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in ,Cement mortar 1:4 (1 cement : 4 coarse sand)
5.66
39410
6965.46
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape wherever required.
31.5
18989
602.84
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design
mix)
104.52
142378
1362.21
Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) : * With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
90
905067
10056.3
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
24.6
5835
237.2
20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
19.8
6250
315.7
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. two coats
207.6
21486
103.5
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
207.6
22952
110.56
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12
graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
19.61
62965
3210.67
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete Serrated with central bulb (225 mm wide, 8-11 mm thick
300.75
139818
464.9
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than
90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage For vertical surface two coats @ 0.70 kg per sqm
278.25
117026
420.58
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than
90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm.The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage For horizontal surface one coat @1.10 kg per sqm
115.63
37482
324.17
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
800
81280
101.6
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 5
226
1115517
4935.92
Supply,installation,Testing,Commisioning of electromechanical equipment for STP 120KLD (SBR TECHNOLOGY) including of items: 1.Bar screen 600*800mm(ss304) ,2. Sewage lifting pump @ 5m3/hr,8-10 m head, Make: kirloskar/equivalent.3. Air blower @ 254m3/hr, Make: everest/eqivalent,4. air diffusers,pressure gauge as per requirement. 5.SBR decanter with PLC based pannel @ 5cum/hr , Make: PTE/ equivalent. 6. oil skimmmer 150mm belt,v type. 7. Dosing pump 0-6 lph 1no. Dosing tank 1nos. of 100 litre. 8. Filter feed pump @ 6m3/hr, Make: kirloskar/cromptom/eqi. 9. Multi grade filter with frontal,piping,valves,prssure gauges etc. filter make: MSFRP, 1nos. 10. Activated carbon filter with all accesories like multi grade filter, filtration @ 17.5m3/hr/m2( ACF AND MGF WITH SAME FILTRATION RATE). 11. Screw pump @ 1m3/hr Make: rotomac/eqi. 12. Filter press 18"*18" Make :pharmatech/ eqi, 13. slude recirculation pump @ 10m3/hr,head 12m, 14. 2nos. sludge pump @ 2m3/hr, head 12m. 15. poly dosing pump, tank , All plant piping, D.O meter etc as per requirement,16.clarified water pump @6m3/hr. NOTE: All pumps,blowers etc should be 1 working and 1 standby. ELECTRICAL PANNEL PLC BASED complete with starters, overload relay, voltmeter, ammeter, push bottoms, auto-manual switches etc. * TRAINING SHOULD BE GIVEN TO CCL PEOPLE FOR 1 MONTH, ALL MACHINERY AND PLANT WARRANTY FOR 1 YEAR. TRATED SAMPLE TESTING FROM APPROVED LAB FOR 1 TIME. OPERATION AND MAINTAINENCE FOR 4 YEAR INCLUDING PLANT OPERATORS FOR 2 SHIFTS A DAY and CLEAR WATER SAMPLE TESTING EVERY 3 MONTHS INTERVAL.
1
6200000
6200000
OPERATION AND MAINTENANCE OF 90 MANHOLES AND PIPELINES OF WHOLE COLONY INCLUDING 2 LABOURS FOR 4 YEARS (365 DAYS A YEAR) INCLUDING ALL NECESSARY FITTINGS AND EQUIPMENTS REQUIRED.
48
1719659
35826.24
Total impact of GST for the purpose of CTC
1
3045098
3045098.06
Evaluation Notes How It Works ?