Central Coalfields Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Central Coalfields Limited - CCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Jan 2024
Closing Date22 Jan 2024
Tender Amount₹ 3,67,806 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing metal box of 150 X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front incl. providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch connection painting etc as required (For light plugs to be used in non-residential building).

24

-

-

... More
Supply and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts, on surface / recess, complete with tinned copper bus-bar neutral busbar, earth bar, din bar interconnection powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 2 + 4 way/6 way Double door

2

-

-

... More
Providing and fixing 5 Amp to 32 Amp rating 240/215 V "C" curve miniature circuit bracket suitable for inductive load of single pole and natural in the existing MCB DB complete with connection testing and commissioning etc as required. Single pole & neutral.

4

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc. as required.

8

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N

2

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.: 2 x 6 sq. mm

150

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm

210

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

28

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required

28

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

2

-

-

... More
20 amps. TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure

5

-

-

... More
Part B (enter zero for this row)

1

-

-

... More
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq. mm. FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A.

72

-

-

... More
Supply and fixing metal box of 150 X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front incl. providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch connection painting etc as required (For light plugs to be used in non-residential building).

28

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required

13

-

-

... More
Supply and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts, on surface / recess, complete with tinned copper bus-bar neutral busbar, earth bar, din bar interconnection powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 2 + 4 way/6 way Double door.

4

-

-

... More
Providing and fixing 5 Amp to 32 Amp rating 240/215 V "C" curve miniature circuit bracket suitable for inductive load of single pole and natural in the existing MCB DB complete with connection testing and commissioning etc as required. Single pole & neutral.

8

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc. as required.

13

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N

4

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.: 2 x 6 sq. mm

190

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm

170

-

-

... More
Supply & drawing following size FR PVC insulated copper conductor single core cable in the existing surface recessed steel/ PVC conductor as required 2 X 2.5 Sq. mm.

30

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

38

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required

4

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
Part C (Enter zero for this row)

1

-

-

... More
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq. mm. FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A.

29

-

-

... More
Supply and fixing metal box of 150 X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front incl. providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch connection painting etc as required (For light plugs to be used in non-residential building).

10

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required

4

-

-

... More
Supply and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts, on surface / recess, complete with tinned copper bus-bar neutral busbar, earth bar, din bar interconnection powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 2 + 4 way/6 way Double door.

1

-

-

... More
Providing and fixing 5 Amp to 32 Amp rating 240/215 V "C" curve miniature circuit bracket suitable for inductive load of single pole and natural in the existing MCB DB complete with connection testing and commissioning etc as required. Single pole & neutral.

3

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N

1

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.: 2 x 6 sq. mm

50

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm

77

-

-

... More
Supply & drawing following size FR PVC insulated copper conductor single core cable in the existing surface recessed steel/ PVC conductor as required 2 X 2.5 Sq. mm.

60

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

14

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required

14

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.