Central Coalfields Limited Tender
... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 46,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CCL_329253_1Bid Award Id
ViewTender No
GM(PPR)/Civil/E-tender/2024-25 /3658Tender Authority
Central Coalfields Limited ViewPurchaser Address
-Website
http://http://www.centralcoalfields.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Thorough repair of qtrs. CH2A 1, CH2A 2, CH2A 3, CH2A 4, CH2A 6, and CH2A 10 including repair of garage in 09 nos. 2A type qtrs. in post office colony and qtr. No. 2AR 4, in Anand Vihar Colony under GM Unit, Piparwar Area.
BOQ Items
... More
ProvidingandlayingCeramicglazedfloortilesofsize300x300mm(thickness
tobespecifiedbythemanufacturer)of1stqualityconformingtoIS:15622of
approvedmakeincolourssuchasWhite,Ivory,Grey,FumeRedBrown,laid
on20mmthickcementmortar1:4(1Cement:4Coarsesand),Jointingwith
greycementslurry@3.3kg/sqmincludingpointingthejointswithwhite
cement and matching pigment etc., complete.
63.8
762
48666.64
... More
ProvidingandfixingIstqualityceramicglazedwalltilesconformingtoIS:
15622(thicknesstobespecifiedbythemanufacturer),ofapprovedmake,in
allcolours,shadesexceptburgundy,bottlegreen,blackofanysizeas
approvedbyEngineer-in-Charge,inskirting,risersofstepsanddados,over12
mmthickbedofcementmortar1:3(1cement:3coarsesand)andjointing
withgreycementslurry@3.3kgpersqm,includingpointinginwhitecement
mixed with pigment of matching shade complete.
112.8
871
98282.64
... More
Providingandfxingaluminiumworkfordoors,windows,ventilatorsand
partitionswithextrudedbuiltupstandardtubularsections/appropriateZ
sectionsandothersectionsofapprovedmakeconformingtoIS:733and
IS:1285,fixingwithdashfastenersofrequireddiaandsize,including
necessaryfillingupthegapsatjunctions,i.e.attop,bottomandsideswith
requiredEPDMrubber/neoprenegasketetc.Aluminiumsectionsshallbe
smooth,rustfree,straight,mitredandjointedmechanicallywherever
requiredincludingcleatangle,AluminiumsnapbeadingforglazingIpaneling,
C.P.brass/stainlesssteelscrews,allcompleteasperarchitecturaldrawings
andthedirectionsofEngineer-in-charge.(Glazing,panelinganddash
fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
138.6
395
54767.79
... More
Providingandfxingaluminiumworkfordoors,windows,ventilatorsand
partitionswithextrudedbuiltupstandardtubularsections/appropriateZ
sectionsandothersectionsofapprovedmakeconformingtoIS:733and
IS:1285,fixingwithdashfastenersofrequireddiaandsize,including
necessaryfillingupthegapsatjunctions,i.e.attop,bottomandsideswith
requiredEPDMrubber/neoprenegasketetc.Aluminiumsectionsshallbe
smooth,rustfree,straight,mitredandjointedmechanicallywherever
requiredincludingcleatangle,AluminiumsnapbeadingforglazingIpaneling,
C.P.brass/stainlesssteelscrews,allcompleteasperarchitecturaldrawings
andthedirectionsofEngineer-in-charge.(Glazing,panelinganddash
fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fxing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of pqwder coating 50 micron)
137.76
462
63652.01
... More
Providingandfixingglazinginaluminiumdoor,window,ventilatorshuttersand
partitionsetc.withEPDMrubber/neoprenegasketetc.completeasperthe
architecturaldrawingsandthedirectionsofengineer-in-charge.(Costof
aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
38.34
824
31617.08
... More
ProvidingandfixingISImarkedflushdoorshuttersconformingtoIS:2202
(PartI)non-decorativetype,coreofblockboardconstructionwithframeof1st
classhardwoodandwellmatchedcommercial3plyveneeringwithvertical
grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished
M.S. piano hinges with necessary screws
13.26
1530
20295.76
... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pig mentto match thes hade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed ofcement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cementsqm
878.5
792
696606.58
... More
ProvidingandfixingISImarkedflushdoorshuttersconformingtoIS:2202
(PartI)decorativetype,coreofblockboardconstructionwithframeof1st
classhardwoodandwellmatchedteak3plyveneeringwithverticalgrainsor
cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary
screws
25.23
2388
60268.16
... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer all complete.
316.58
77
24677.41
... More
Removingdryoroilbounddistemper,waterproofingcementpaintandthelike
byscrapping,sandpaperingandpreparingthesurfacesmoothincluding
necessary repairs to scratches etc. complete.
525
15
8006.25
... More
Providingandapplyingwhitecementbasedputtyofaveragethickness1mm,
ofapprovedbrandandmanufacturer,overtheplasteredwallsurfaceto
prepare the surface even and smooth complete.
525
98
51686.25
... More
Distemperingwith1stqualityacrylicdistemper(readymixed)havingVOC
contentlessthan50gram/litre,ofapprovedmanufacturer,ofrequired
shade and colour all complete: New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 pram/litre
2067.45
115
237756.75
... More
Providingandfixingwaterclosetsquattingpan(IndiantypeW.C.pan)with
100mmsandcastIronPorStrap,10litrelowlevelwhiteP.V.C.flushing
cistern,includingflushpipe,withmanuallycontrolleddevice(handlelever)
conformingtoIS:7231,withallfittingsandfixturescomplete,including
cutting and making good the walls andfloors wherever required: WhiteVitreouschinaOrissapatternW.C.panofsize580x440mmwithintegral
type foot rests
3
4774
14323.35
... More
Providingandfixingwhitevitreouschinapedestaltypewatercloset(European
typeW.C.pan)withseatandlid,10litrelowlevelwhiteP.V.C.flushingcistern,
includingflushpipe,withmanuallycontrolleddevice(handlelever),conforming
toIS:7231,withallfittingsandfixturescomplete,includingcuttingand
making good the walls andfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
7
4565
31957.8
... More
ProvidingandlayingflamedfinishGranitestoneflooringinrequireddesignand
patterns,inlinearaswellascurvilinearportionsofthebuildingallcompleteas
perthearchitecturaldrawingswith18mmthickstoneslabover20mm
(average)thickbaseofcementmortar1:4(1cement:4coarsesand)laidand
jointedwithcementslurryandpointingwithwhitecementslurryadmixedwith
pigmentofmatchingshadeincludingrubbing,curingandpolishingetc.all
complete as specified and as directed by the Engineer-in-Charge :FlamedfinishgranitestoneslabJetBlack,CherryRed,EliteBrown,CatEyeor
equivalent.
6
2138
12831
... More
ProvidingandfixingStainlessSteelAISI304(18/8)kitchensinkasper
IS:13983withC.I.bracketsandstainlesssteelplug40mm,includingpainting
of fittings and brackets, cutting and making goodthe walls wherever required : Kitchen sink without drain board .2610x460 mm bowl depth 200 mm
4
2785
11143
... More
ProvidingandfixingwashbasinwithC.I.brackets,15mmC.P.brasspillar
taps,32mmC.P.brasswasteofstandardpattern,includingpaintingoffittings
and brackets, cutting and making good the wallswherever require: WhiteVitreousChinaAnglebackwashbasinsize600x480mmwithsingle
15mm C.P. brass pillar tap
6
1661
9968.1
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plasterincludingdisposalofrubbishtothedumpinggroundwithin50metres
lead.
140
32
4480
... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
140
217
30478
... More
ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,having
thermalstabilityforhot&coldwatersupply,includingallCPVCplain&brass
threadedfittings,includingfixingthepipewithclampsat1.00mspacing.This
includesjointingofpipes&fittingswithonestepCPVCsolventcementand
testingofjointscompleteasperdirectionofEngineerinCharge.Internalwork -
Exposed on wall 15 mm nominal dia Pipes
70
200
14063
... More
ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,having
thermalstabilityforhot&coldwatersupply,includingallCPVCplain&brass
threadedfittings,includingfixingthepipewithclampsat1.00mspacing.This
includesjointingofpipes&fittingswithonestepCPVCsolventcementand
testingofjointscompleteasperdirectionofEngineerinCharge.Internalwork -
Exposed on wall 20 mm nominal dia pipes meter
42
259
10880.1
... More
ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes,having
thermalstabilityforhot&coldwatersupply,includingallCPVCplain&brass
threadedfittings,includingfixingthepipewithclampsat1.00mspacing.This
includesjointingofpipes&fittingswithonestepCPVCsolventcementand
testingofjointscompleteasperdirectionofEngineerinCharge.Internalwork -
Exposed on wall 25 mm nominal dia Pipes
70
331
23205
... More
ProvidingandfixingC.P.brassbibcockofapprovedqualityconformingto
IS:8931 : 15 mm nominal boreeach
14
376
5277.3
... More
ProvidingandfixingC.P.brassanglevalveforbasinmixerandgeyserpointsof
approved quality conforming to IS:8931 15mm nominal boreeach
7
434
3040.8
... More
Construction of 10 user septic rankes per standard design, drawing and instruction of EIC etc all complete.
2
36118
72237.58
... More
Constructingsoakpit1.20x1.20x1.70mfilledwithbrickbatsincluding
S.W.drainpipe100mmdiameterand1.20mlongcompleteasperstandard
design.
2
2366
4732
... More
Brick masonry inspection chamber as per design and Drawing.
6
4871
29226.9
... More
Finishing walls with water proofing cement paint of required shade : Oldwork(oneormorecoatsapplied@2.20kg/10sqm)overprimingcoatof
primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
1750
72
126525
... More
Paintingwithsyntheticenamelpaintofapprovedbrandandmanufactureof
required colour to give an even shade : One or more coats on old work
210
65
13786.5
... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size)
18
6616
119094.3
... More
ProvidingandlayingAPP(AtacticPolypropylenePolymer)modified
prefabricatedfivelayer,3mmthickwaterproofingmembrane,blackfinished
reinforcedwithglassfibremattconsistingofacoatofbitumenprimerfor
bitumenmembrane@0.40litre/sqmbythesamemembranemanufacturedof
densityat25°C,0.87-0.89kg/litreandviscocity70-160cps.Overthe
primercoatthelayerofmembraneshallbelaidusingbutanetorchandsealing
alljointsetc.,andpreparingthesurfacecomplete.Thevitalphysicaland
chemicalparametersofthemembraneshallbeasunder:Jointstrengthin
longitudinalandtransversedirectionat23°Cas350/300N/5cm.Tear
strengthinlongitudinalandtransversedirectionas60/80N.Softeningpointof
membranenotlessthan150°C.Coldflexibilityshallbeupto-2°Cwhentested
inaccordancewithASTM,D-5147.Thelayingofmembraneshallbegotdone
through the authorised applicator of the manufacturer of membrane : 3 mm thick
540
443
239598
... More
ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwaterpipes
conformingtoIS:13592TypeA,includingjointingwithsealringconforming
toIS:5382,leaving10mmgapforthermalexpansion,(i)Singlesocketed
pipes. 110 mm dia meter
49
262
12857.6
... More
Providingandfixingonwallfaceunplasticised-PVCmouldedfittings/
accessoriesforunplasticisedRigidPVCrainwaterpipesconformingtoIS:
13592TypeA,includingjointingwithsealringconformingtoIS:5382,
leaving 10 mm gap for thermal expansion. Bend 87.5' 110 mm bend
14
114
1604.4
... More
ProvidingandfixingunplasticisedPVCpipeclipsofapproveddesignto
unplasticised-PVCrainwaterpipesbymeansof50x50x50mmhardwood
plugs,screwedwithM.S.screwsofrequiredlength,includingcuttingbrick
workandfixingincementmortar1:4(1cement:4coarsesand)andmaking
good the wall etc. complete. 110 mm
56
234
13148.8
... More
Providingandfixing8mmdiaC.P./S.S.Jetwithflexibletubeupto1metre
longwithS.S.triangularplatetoEureopeantypeW.C.ofqualityandmakeas
approved by Engineer - in - charge.
7
259
1819.3
... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square orround barsetc. Including priming coat with approved steel primer all complete. 9.48.1Fixed to steel windows by welding
486
145
70761.6
... More
PART B (Garrage Repair ) Demolishingcementconcretemanually/bymechanicalmeansincluding
disposalofmaterialwithin50metresleadasperdirectionofEngineer-in
- charge. 15.2.1Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
9
1412
12711.6
... More
Providingandlayinginpositioncementconcreteofspecifiedgrade
excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4(1cement:2coarsesand(zone-III)derivedfromnaturalsources:4
graded stone aggregate 20 mm nominal size derived from natural sources)
9
6490
58418.1
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plasterincludingdisposalofrubbishtothedumpinggroundwithin50metres
lead.
225
32
7200
... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
225
217
48982.5
... More
Finishing walls with water proofing cement paint of required shade : Old work(oneormorecoatsapplied@2.20kg/10sqm)overprimingcoatof
primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
1049.8
72
75900.54
... More
Providingandfixingprecoatedgalvanisedironprofilesheets(size,shapeand
pitchofcorrugationasapprovedbyEngineer-in-Charge)oftotalcoated
thickness0.50mm(basemetalofminimum0.45mmthicknesswithtotal
coatingthicknessof0.05mm)withzinccoating120gramspersqmasperIS:
277,in240mpasteelgrade,5-7micronsepoxyprimeronbothsideofthe
sheetandpolyestertopcoat15-18microns.Sheetshouldhaveprotective
guardfilmof25micronsminimumtoavoidscratchesduringtransportation
andshouldbesuppliedinsinglelengthupto12metreorasdesiredby
Engineer-in-charge.Thesheetshallbefixedusingselfdrilling/selftapping
screwsofsize(5.5x55mm)withEPDMseal,completeuptoanypitchin
horizontal/verticalorcurvedsurfaces,excludingthecostofpurlins,rafters
and trusses and including cutting to size and shape wherever required.
218.66
571
124856
... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
704.21
77
54893.17
... More
Total impact of GST for the purpose of CTC
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements