Central Coalfields Limited Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 18,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CCL_318051_1Bid Award Id
ViewTender No
SO(EnM)/BS/eTender/24-25/1141Tender Authority
Central Coalfields Limited ViewPurchaser Address
-Website
http://http://www.centralcoalfields.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X10sq.mm+1X6sq.mm earth wire
100
-
-
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4X16sq.mm+2X6sq.mm earth wire
65
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc. as required.100mm X 100mm X 60mm deep
75
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc. as required.180mm X 100mm X 60mm deep
60
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200mm X 150mm X 75mm deep
30
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200mm X 250mm X 60mm deep
40
-
-
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required.5/6amps switch
75
-
-
Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required.3 pin 5/6 amp socket outlet
75
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
50
-
-
Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size ) on surface of in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 Amp socket outlet and 5/6 Amp piano type switch connection painting etc. as required.
45
-
-
Supplying and fixing metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 6pin5/6 &15/16amps socket outlet and 15/16amps piano type switch, connection, painting etc. as required.
41
-
-
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25Amps modular SP MCB,“C” curve including connection, painting etc. as required.
23
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
135
-
-
Supplying and fixing following rating, double pole, 240volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
13
-
-
Supplying and fixing following rating, double pole, 240volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps
12
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps
6
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 16 way, Double door
6
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with inned copper busbar, neutral busbar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8way (4+24), Double door
4
-
-
Chemical Earthing : 80 mm dia Earthing Electrode 3mtr. Length, Backfill Compound chemical 4 Bag (per bag 25 Kg), Earth cutting removing and installation charge.
3
-
-
Providing and fixing 6SWG dia G.I.wire on surface or in recess for loop earthing as required.
80
-
-
Supplying, installing, testing and commissioning of following capacity
TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with
powder coating on existing rising mains complete with TPN disconnector FSUand HRC fuses, connections, earthing etc. as required(200A).
1
-
-
Providing and fixing following busbar chamber with 4 strip of suitable size made of copper heavy duty, Complete with all accessories including connections, earthing the body, etc. as required . 200 Amps
1
-
-
Total impact of GST for the purpose of CTC