Building Construction Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department Tender

Works
Eprocure
Opening Date23 Jul 2021
Closing Date29 Jul 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for earth work in hard soil as per specification and direction of E/I. (Vide classification of soil item-B)

112.27

-

-

... More
Earth Filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).

187.12

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).

6.04

-

-

... More
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.

13.98

-

-

... More
Providing designation 75 B brick work in C.M.(1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scaffolding, raking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.

183.86

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

6.22

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

2.17

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

-

-

-

... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

10.41

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

93.48

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.

2.52

-

-

... More
Providing Tor steel reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.

-

-

-

... More
8 mm dia

3.52

-

-

... More
10 mm dia

3.14

-

-

... More
12 mm dia

1.15

-

-

... More
16 mm dia

1.15

-

-

... More
20 mm dia, 25 mm dia

0.97

-

-

... More
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)

1138.08

-

-

... More
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.

93.98

-

-

... More
Providing and laying 25 mm thick kota stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12 mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.

3.09

-

-

... More
Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

36.8

-

-

... More
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.

425.6

-

-

... More
Providing 12 mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

2844.98

-

-

... More
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.

91.12

-

-

... More
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.

182.02

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.

6.05

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust , dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)

176.24

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.

574.7

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

193.5

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.

26.4

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

56.44

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

-

-

-

... More
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

58.75

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

207.36

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)

124.43

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)

75.8

-

-

... More
Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l.

3044.34

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

1315.7

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1756.14

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm

971.9

-

-

... More
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specification and direction of E/I.

508.16

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

7340.39

-

-

... More
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

58

-

-

... More
Taking down choukhat in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

22

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.

10.41

-

-

... More
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement

1.67

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm

5.02

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

6.63

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes.

-

-

-

... More
110 mm diameter

21.95

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single tee with door 110x110x110 mm

6

-

-

... More
Bend 87.5° 110 mm

6

-

-

... More
Shoe (Plain) 110 mm

6

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

24

-

-

... More
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.

164.57

-

-

... More
Providing random rubble stone masonry in cm (1:6) in superstucture with hammer dressed stone of less than 0.03 M3 in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I

2.82

-

-

... More
Extra for cleaing the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I

1856.15

-

-

... More
Providing tuck pointing in cement on stone masonry (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I

287.36

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

287.36

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface

2363.29

-

-

... More
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.

36

-

-

... More
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.

8.67

-

-

... More
Taking down choukhat in windows including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

36

-

-

... More
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/l.

2101.9

-

-

... More
Providing and laying Double Charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete. Size of Tile 600 x 600 mm

196.69

-

-

... More
Extra for flooring work for each consecutive floor above first floor complete as per direction of E/l

147.52

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C, Fixing with adjustable lugs with split end tail to each jamb

84

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

108.76

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.

807.36

-

-

... More
Dismantling R.C.C.work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.

108.74

-

-

... More
Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5 % cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

1264.01

-

-

... More
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/l.

128.25

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)

-

-

-

... More
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).

33.75

-

-

... More
Providing and laying 25 mm thick white makrana marble stone slab flooring of approved quality over 19 mm. thick base of lime mortar (1:1:1) ( Lime putty : surkhi: coarse sand) laid and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. 300 x 300 mm

2.03

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

50

-

-

... More
Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/l.

2356.58

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

72.9

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

-

-

-

... More
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating

-

-

-

... More
principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml

-

-

-

... More
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm

-

-

-

... More
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

14.58

-

-

... More
Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/l.

108

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable

3050

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520

-

-

-

... More
(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.

-

-

-

... More
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head

1

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
Incomings 800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 1000Amps

-

-

-

... More
Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets

-

-

-

... More
Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets

-

-

-

... More
DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

20

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

20

-

-

... More
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required

-

-

-

... More
3.5 x 50 sq.mm (aluminium)

360

-

-

... More
3.5 x 35 sq mm (aluminium)

30

-

-

... More
4 x 16 sq.mm.(aluminium)

30

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :

-

-

-

... More
150 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 mm dia

6

-

-

... More
100 mm dia

12

-

-

... More
150 mm dia

6

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

3

-

-

... More
150 mm dia

2

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
150 mm dia

252

-

-

... More
100 mm dia

352

-

-

... More
80 mm dia

72

-

-

... More
50 mm dia

30

-

-

... More
25 mm dia

30

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal.

18

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m

16

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

18

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

18

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. For suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe

3

-

-

... More
Circuit/ submain wiring PVCCONDUIT:- Wiring for Circuit/ submain wiring along with earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq mm + 1x1.5 sq. mm earth wire.

30

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

1005

-

-

... More
Chemical Earthing :- Supply, errection, fitting, fixing, commissioning and testing along with earth cutting, digging, earth refilling for chemical earthing of the building except G.I. Strips (25mmX5mm) Each earth pit has to be tested with earth tester 1000 V/1000 Ohms & the test report has to be submitted by the contractor to the department after certification of the same by the consultant. The above chemical earthing includes the provision of masonary enclosure and HDPE Earth Pit Cover 300mm X 300 mm (Under-floor earth inspection pit) having locking arrangement as earth chamber.The above chemical earthing includes the following items (3 Mtr Earthing)

1

-

-

... More
Supply of Helper.

100

-

-

... More
Supply of Head Carpenter.

20.9

-

-

... More
Supply of Carpenter.

33.43

-

-

... More
Supply of Iron Nail 125 mm and below

23.74

-

-

... More
Supply of Iron Nail Above125 mm

24.1

-

-

... More
Carriage of materials

-

-

-

... More
Bricks

83.36

-

-

... More
Sand

192.79

-

-

... More
Chips

91.29

-

-

... More
Metal

5.84

-

-

... More
Boulder

2.82

-

-

... More
Building rubbish

279.16

-

-

... More
Non Schedule

-

-

-

... More
Supplying and installation of 19 mm thick Ply wood Supply on Site as per specification and direction of E/I. (Make :- Greenpanel / Green decor or Equivalent)

253.73

-

-

... More
Supplying and installation of 12 mm thick Ply wood Supply on Site as per specification and direction of E/I. (Make :- Greenpanel / Green decor or Equivalent)

60.14

-

-

... More
Supplying and installation of 6 mm thick Ply wood Supply on Site as per specification and direction of E/I. (Make :- Greenpanel / Green decor or Equivalent)

15.04

-

-

... More
Supply and installation of 0.8 mm thick Laminate Supply on Site as per specification and direction of E/I. (Make :- Greenlam/Greenpanel or equivalent)

496.19

-

-

... More
Supply and installation of 1 mm thick Laminate Supply on Site as per specification and direction of E/I. (Make :- Greenlam/Greenpanel or equivalent)

134.25

-

-

... More
Supply and installation of Magnet Supply on Site as per specification and direction of E/I.

14.32

-

-

... More
Supply of industrial adhesive Supply on Site as per specification and direction of E/I.

23.78

-

-

... More
Supply and installation of Antique Hinges as per specification and direction of E/I. (Make :- Dorset, Godrej or Equivalent)

43.93

-

-

... More
Supply and installation of Handle Small Size for Cupboard or Rack etc. as per specification and direction of E/I. (Make :- Dorset, Godrej or Equivalent)

11

-

-

... More
Supplying and installation of Evro Tape Supply on Site as per specification and direction of E/I.

12

-

-

... More
Supply and installation of Antique Door Handle as per specification and direction of E/I. (Make :- AKS, Godrej or Equivalent)

8

-

-

... More
Supply and installation of Antique Door Lock as per specification and direction of E/I. (Make :- AKS, Godrej or Equivalent)

4

-

-

... More
Supply and installation of Door Closer as per specification and direction of E/I. (Make :- Dorset, AKS or Equivalent)

4

-

-

... More
Supplying and installation of 30 mm thick Flush Door Supply on Site as per specification and direction of E/I. (Make :- Greenpanel / Green decor or Equivalent)

9.7

-

-

... More
Supplying and installation of 4 mm thick Veneer Supply on Site as per specification and direction of E/I. (Make :- Greenpanel / Green decor or Equivalent)

19.4

-

-

... More
Providing 2 coats of High Grade Cyanuramide based resin, closed pore polish on veneer and wooden surface with Sanding, Filling, Nitrocellulose based single pack clear wood sealer, Coloring, Cyanuramide coating and final finishing all complete as per the Direction of E/I.

8.82

-

-

... More
Waterproofing Treatment to RCC Roof Slab. a) Preparation of the surface: Oil, grease, funguses etc. by wire brush and wash with plenty of water. b) Providing and applying STARBOND BASB 30 (It is Bonding Agent) using all joint and repair honey-comb area, cracks and other coving area on terrace. c) Providing and applying three coats of STARPROOF WF MB 602 single components rubberrized elastomeric highly waterproofing coating. It is cold applied liquid waterproofing membrance, specially designed from a blend of special water repelling fillers, minerals stabilizers and gelling agent. Apply by brush on the cleaned surface.

2395.42

-

-

... More
Pressure Gauge Assemble with Gate/Ball Valve

3

-

-

... More
Pressure Sensor / Switch for Automatic Start of Pumps

3

-

-

... More
Air release / Drain Valve

3

-

-

... More
MS Structure support for piping

500

-

-

... More
Providing and fixing 25 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)

20

-

-

... More
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect for external hydrant as required complet in all respects.

18

-

-

... More
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (6 Kg Capacity)

30

-

-

... More
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity)

10

-

-

... More
Providing and fixing of Modular type 5 Kg Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Automatic Discharge Mechanism, Pressure Gauge, As per ‘IS 15683’ ISI mark Automatic modular type Fire Extinguishers. Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects.

210

-

-

... More
SITC of Wireless Fire Alarm Control Panel - with Built in ABS housing. All devices can be programmed. 110 DB dual sound in built. Covers more than 500 meter to 1 KM area. Indicates particular detector number as per programming. Rechargeable backup battery 12V 1.2ah 220V AC supply needed. Any modification in Programming can be done manually through the panel. Make: Qutak, Honeywell, Apollo, Kidde

1

-

-

... More
SITC of Wireless Smoke Detector - Made of poly-styrene plastic. No wiring is required for any connectivity. Area covers approx 3.5 to 4.5 mtr. with 10 to 11 feet height. Operates on 9V Alkaline Battery. Gives low battery sound signal. Comes with TEST button. Blinks in every 35 seconds. Has connectivity with Radio Emitter. Make: Qutak, Honeywell, Apollo, Kidde

380

-

-

... More
SITC of Wireless Emitter - No wiring is required for any connectivity with any device 5 to 7 nos. detectors can be programmed with each radio emitter as per premises condition. Communicate with detectors in radius of 7 to 12 mtr. as per premises condition. 90 DB Sounder Inbuilt. Operates on rechargeable Batteries AAA Size 1.2 Volt type-10 nos. in each radio emitter. 220V AC supply needed for radio emitter charging. Has connectivity with remote key fob and panel. Make: Qutak, Honeywell, Apollo, Kidde

38

-

-

... More
SITC of Wireless Key fob - Works as MCP, to arm/disarm alarm host and to check the healthiness of the system. Every remote key fob is specially designed to work with its individual emitter. Does not work with other emitter because of its unique coding. Distance between radio emitter to remote key fob can be 10 mtr. Make: Qutak, Honeywell, Apollo, Kidde

12

-

-

... More
Footinng preparation and preparation of necessary support for Pipeline work at Staircase and on Terrace.

1

-

-

... More
Supply, fitting, fixing, connecting and testing of switch with 24 x 10/100/1000T PoE ports and 4 x 100/1000X SFP ports, PoE+ L2 Switch , Switching Capacity 56Gbps and Forwarding Rate 41.7Mpps, Switch should support PoE and PoE+ with 370W minimum power budget, operaating temperature 0°C to 50°C, Switch should support link reccovery within 50ms for Ring architecture, SDN or similar kind of technolgy should support, . Make:- Cisco - WS-C9300L-24P-4G / Allied Telesis -AT-x230-28GP / Juniper - EX2200-24P) The above L2 Managed Data Switch consists of the following :- 1. Power cord India, right angle. 2. Both side Cable connector. 3. 1 year free service pack. Interface- 24 x 10/100/1000T ports and 4 x 100/1000X SFP ports

-

-

-

... More
Switching Capacity/Forwarding Rate :- 56Gbps/41.7Mpps. Performance:- Up to 16K MAC addresses, 256MB DDR SDRAM. Management:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3, powerful centralized management and zero-touch device installation and recovery like SDN, Security:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3, powerful centralized management and zero-touch device installation and recovery like SDN, Routing:- IPv4 static routing and RIP.

-

-

-

... More
Fail-over:- Switch capable of recovery within 50ms in a ring for application high availability, IPv6:- Device management over IPv6 networks with SNMPv6, Telnetv6, SSHv6 and Syslogv6, Diagnostic:- Optical Digital Diagnostics Monitoring,Automatic link flap detection and port shutdown,Port and VLAN mirroring (RSPAN), Standard Protocol:- IEEE 802.1Q,IEEE 802.1w,IEEE 802.1s,IEEE 802.1p,IEEE 802.1AB,IEEE 802.1AX,IEEE 802.3ad Operating Temparature:- 0°C to 50°C, Certification:- EN,UL and RoHS.

4

-

-

... More
SITC of Gigabit Fiber Module-MM, Support up to 550mtr (Make:- Cisco - GLC-SX-MMD / Allied Telesis -Model No. GLC-SX-MMD/AT-SPSX/CTP-SFP-1GE-SX) / Juniper - CTP-SFP-1GE-SX)

8

-

-

... More
24 Port LIU : SITC of 24 Port Loaded LIU with SC Unit for 24 MM fiber Multi mode fibres OM3 (4 Nos. of Loaded Duplex adapter with Adapter plate) along with 1 Pc of Splice Tray - 24 Fiber Capacity & 24 Nos. of SC Pigtail - Pigtail 1 Meter Multi Mode OM3 (Make:Legrand/Panduit/RIT/Siemon)

1

-

-

... More
SITC of Fiber Duplex Patch Cords SC-LC MM-OM3 Patch Cord 2 mtr. (Make:Legrand/Panduit/RIT/Siemon)

8

-

-

... More
SITC of 6-Core OM3 MM Armoured Fibre Optics Cable in Mtrs: (Make:Legrand/Panduit/RIT/Siemon)

300

-

-

... More
SITC of 24 port UTP jack panel (24 port RJ-45 Loaded CAT-6 UTP 19" rackmountable patch panel preferbaly with 6 blocks). (Make:Legrand/Panduit/RIT/Siemon)

4

-

-

... More
SITC of Straight LAN Patch Chord-1 Mtr (Make:Legrand/Panduit/RIT/Siemon)

57

-

-

... More
SITC of white modular plate type Single front plate for 1 Nos. RJ 45 Data outlet (Make:Legrand/Panduit/RIT/Siemon)

57

-

-

... More
SITC of RJ 45 Data Module to be fixed on face plate (Make:Legrand/Panduit/RIT/Siemon)

57

-

-

... More
Splicing of Armoured SM/MM Fibre Optics Cable: Splicing, testing and commissioning of supplied, OFC cable of 6-Core Armoured Fibre Optics

42

-

-

... More
SITC of Fully Loaded 9 U 19" 600*600 Wall Mounted Rack with all required accessories -2 Nos. of Fan,6A 6 Plug PDU-1 Nos. ,Cable Manager-2 Nos., Mounting Screws-20 Pcs ; Preffered Make-Legrand/APW/President/Valrack

4

-

-

... More
Supply and installation of 4x4 PVC Gang Box with plate.

57

-

-

... More
SITC of Single Phase Online 6 KVA UPS with required nos of 12V SMF 18 Nos of 42 AH battery ,Rack & Interconnecting cable UPS to battery (10mtrs) for Connected Switches and Cameras Preffered Make-Vertiv/GUTUR/APC

1

-

-

... More
SITC of 4MP IR Bullet Fixed Camera -1/3" Progressive Scan CMOS, 2688 × 1520 at 25fps, 2.8mm Fixed lens, 0.01 Lux at F1.2, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Alarm & Audio: 1 input & 1 output, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Audio exception detection, video tampering, UL, CE, FCC certified.Preferred Make- Axis/Pelco/Hikvision

56

-

-

... More
SITC of 64 Channel NVR Processor : Dual-core embedded processor,Operating System : Pre-loaded Licensed OS,IP Camera Support : Min 64 Channel or higher,Two way talk : 1 Channel O/P and 1 Channel I/P,Compression : H.265, H.264, MJPEG4,Video Resolution: Should support up to 8MP IP Camera. Video Recording (Incoming bandwidth) : 256 Mbps,Video Display Split : 1/4/8/16/32,Video Loss : Support,Camera Blank : Support,Alarm Input/ Output : Min 16 channel / Min 4 Channel or betterHard Disk : Min 8 SATA ports , up to 32TB , Raid(Redundancy), ,Smart Phone : iPhone, iPad, Android, Windows,Phone,Protocol : IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP,UDP, UPnP, ICMP, IGMP, SNMP,RTSP, RTP, SMTP,NTP, DHCP, DNS, PPPOE, DDNS, FTP, IP Filter,ONVIF Profile S,User Account : 10 Users,Trigger Event : Recording, Alarm, Video Push, Email,FTP,Recording Mode : Manual , Schedule , STOP,Search Mode : Time/Date , Alarm , Motion Detection ,Exact Search (accurate to second), Smart Search,Playback : Play, Stop, Pause, Rewind, Fast Play, Next file, Previous file, Next Camera, Previous Camera, Full Screen, Backup Selection,Backup Mode : USB Device / Internal SATA / NetworkInterface Ports : 2 USB 2.0 , 1 RS485 , 1,RS232, 2 RJ45,Ethernet Ports : 2 RJ-45 port (10/100M/1000M),Power SITC : AC 100V~240V 50/60Hz,Regulatory : CE, FCC,UL and RoHS;Preffered Make-Hikvision/Axis/ Pelco

1

-

-

... More
SITC of 64 Channel NVR Processor : Dual-core embedded processor,Operating System : Pre-loaded Licensed OS,IP Camera Support : Min 64 Channel or higher,Two way talk : 1 Channel O/P and 1 Channel I/P,Compression : H.265, H.264, MJPEG4,Video Resolution: Should support up to 8MP IP Camera. Video Recording (Incoming bandwidth) : 256 Mbps,Video Display Split : 1/4/8/16/32,Video Loss : Support,Camera Blank : Support,Alarm Input/ Output : Min 16 channel / Min 4 Channel or betterHard Disk : Min 8 SATA ports , up to 32TB , Raid(Redundancy), ,Smart Phone : iPhone, iPad, Android, Windows,Phone,Protocol : IPv4/IPv6, HTTP, HTTPS, SSL, TCP/IP,UDP, UPnP, ICMP, IGMP, SNMP,RTSP, RTP, SMTP,NTP, DHCP, DNS, PPPOE, DDNS, FTP, IP Filter,ONVIF Profile S,User Account : 10 Users,Trigger Event : Recording, Alarm, Video Push, Email,FTP,Recording Mode : Manual , Schedule , STOP,Search Mode : Time/Date , Alarm , Motion Detection ,Exact Search (accurate to second), Smart Search,Playback : Play, Stop, Pause, Rewind, Fast Play, Next file, Previous file, Next Camera, Previous Camera, Full Screen, Backup Selection,Backup Mode : USB Device / Internal SATA / NetworkInterface Ports : 2 USB 2.0 , 1 RS485 , 1,RS232, 2 RJ45,Ethernet Ports : 2 RJ-45 port (10/100M/1000M),Power SITC : AC 100V~240V 50/60Hz,Regulatory : CE, FCC,UL and RoHS;Preffered Make-Hikvision/Axis/ Pelco

1

-

-

... More
SITC of 6TB Surveillance Grade Hard Disk for NVR for 30 Days Back up; Make-Seagate/WD

8

-

-

... More
65" 4k LED Panel,Brightness: 350 cd/m2 , Preffered Make-LG/Samsung

1

-

-

... More
6 Port LIU Switch : SITC of 6 Port Loaded LIU with SC Unit for 6 MM fiber Multi mode fibres OM3 (1 Nos. of Loaded Duplex adapter with Adapter plate) along with 1 Pc of Splice Tray - 6 Fiber Capacity & 6 Nos. of SC Pigtail - Pigtail 1 Meter MM OM3 (Make:Legrand/Panduit/RIT/Siemon)

3

-

-

... More
Add 12 % GST

1

-

-

... More
Add 1% Labour Cess

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.