University Of Jammu Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

University Of Jammu Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Oct 2024
Closing Date13 Nov 2024
Tender Amount₹ 89,51,000 
Notes
Download

Costs

Summary

Construction Of Administrative Block At Kupwara Campus (electrification And Fire Alarm System)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Administrative Block at Kupwara Campus (Electrification and Fire Alarm System)
Construction of Administrative Block at Kupwara Campus (Electrification and Fire Alarm System)
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
120 sqmm 3 1/2 core

50

1768

88400

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

41

474

19434

... More
Above 95 sq. mm and upto 185 sq. Mm

50

422

21100

... More
Supply, laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 50 sqmm 3 1/2 core

180

858

154440

... More
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed

-

-

-

... More
3½ X 240 sq. mm (62mm)

4

1027

4108

... More
3½ X 120 sq. mm (45mm)

4

613

2452

... More
3½ X 50 sq. mm (35mm)50

10

413

4130

... More
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
single pole

160

256

40960

... More
Double pole

40

656

26240

... More
Triple pole

6

1007

6042

... More
Triple pole and neutral

6

1228

7368

... More
Supplying and fixing 0.5 A to 3 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole

70

510

35700

... More
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Double pole

14

1450

20300

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. with MS enclosure (2 in each lab) 40 A

16

4642

74272

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door

4

12833

51332

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB

4

8209

32836

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way (4 + 18), Double door (HDB G1G2F1F2)

4

4974

19896

... More
8 way (4 + 24), Double door ( LIGHTING Main Distribution in panel room)

1

5965

5965

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
8 way , Double door (SDB INV)

13

2573

33449

... More
12 way , Double door (SDB L )

13

2315

30095

... More
16 way , Double door (U SDB & PDB)

30

3141

94230

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

50

669

33450

... More
150 mm width X 50 mm depth X 1.6 mm thickness

20

716

14320

... More
225 mm width X 50 mm depth X 1.6 mm thickness

60

895

53700

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

12

1159

13908

... More
150 mm width X 50 mm depth X 1.6 mm thickness

12

1270

15240

... More
225 mm width X 50 mm depth X 1.6 mm thickness

4

1694

6776

... More
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description for the follwing items

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire ((L/I circuit.)

1664

233

387712

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

45

275

12375

... More
2 x 4 sq.mm + 1 x 4 sq.mm earth wire (INV distribution)

210

334

70140

... More
2 x 6 sq.mm + 1 x 6 sq.mm earth wire (L distribution)

310

439

136090

... More
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring (UPS distribution)

310

570

176700

... More
2x 16 sq.mm +1 x 16 sq.mm earth wire for Sub main wiring (H sub-distribution)

685

772

528820

... More
4x 16 sq.mm +2 x 16 sq.mm earth wire for Sub main wiring (H distribution)

220

1365

300300

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including wall cutting, wall repairs and finishing as required

-

-

-

... More
20 mm

50

128

6400

... More
25 mm

120

145

17400

... More
Group A Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. excluding slab conduting as required. note: all items included like Conduit, wire, box, switches wall cutting, wall repairs and finishing as required

480

1015

487200

... More
(Group B) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. note: all items included like Conduit, wire, box, switches wall cutting, wall repairs and finishing as required

144

1182

170208

... More
Providing and fixing of UPS power point power point (in loop .) with 1.5 sq. mm PVC insulated copper wire , through midium classPVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 2 nos. recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 1.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned note: all items included like Conduit, wire, box, switches wall cutting, wall repairs and finishing as required

100

1000

100000

... More
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all respets note: all items included like Conduit, wire, MS box, switches wall cutting, wall repairs and finishing as required

132

2100

277200

... More
Providing and fixing of AC points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular C-curve MCB, socket recessed in wall covered with modular sheet/ MS box at two levels of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all respets note: all items included like Conduit, wire, MS box, switches wall cutting, wall repairs and finishing as required

10

2500

25000

... More
Installation, testing and commissioning of pre-wired, (LED) fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required.

492

206

101352

... More
Supply of 2 ft LED slim 9- 12 watt warm110lm/w 230V Batten type lights(T5 Type) , complete in all respects. Wipro, Halonix, Havells

8

350

2800

... More
Supply of 4 ft LED slim 20 watt warm110lm/w 230V Batten type lights(T5 Type) , complete in all respects. Wipro, Halonix, Havells

130

450

58500

... More
Supply of 12 watt surface/ recess LED slim 230V , complete in all respects. (commertial) Wipro, Halonix, Havells.

20

650

13000

... More
Supply of 15 Watt surface/ recess LED slim 230V , complete in all respects .(commertial) Wipro, Halonix, Havells

80

1000

80000

... More
Supply of 22 Watt surface/ recess LED slim 230V , complete in all respects .(commertial). Wipro, Halonix, Havells

236

2150

507400

... More
Supply of 2ft x 2ft 36 Watt surface/ recess LED slim 230V , complete in all respects. (commertial). Wipro, Halonix, Havells

4

3350

13400

... More
Supplying, installation, testing & commissioning of 150 Watt IP 66 LED flood light 230V , complete in all respects. (commertial). (indoor field) Wipro, Halonix, Havells

8

9500

76000

... More
Supply, fixing of 3W LED Unidirectional Exit Signage Light with inbuilt 2 hours battery back up .

6

5400

32400

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

10

450

4500

... More
Suppyly, testing of 9”x9” flap window type exhaust fan complete with all accessories. etc . Crompton, Halonix, Havells, Usha

10

1550

15500

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote with cells or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

134

3500

469000

... More
Supplying and fixing of fan GI hooks

40

210

8400

... More
Supplying and fixing of 2/2.5 feet fan rods as reuired.

60

250

15000

... More
Supplying and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

4

369

1476

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

180

87

15660

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required.

-

-

-

... More
15/16 A switch

6

156

936

... More
6 pin 15/16 A socket outlet

6

197

1182

... More
5/6 A switch

6

103

618

... More
3 pin 5/6 A socket outlet

6

122

732

... More
Supplying and fixing of 15/ 16 A 3pin Top

6

150

900

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess wall cutting, wall repairs and finishing as required

-

-

-

... More
1 or 2 Module (75mmX75mm)

24

298

7152

... More
4 Module (125mmX75mm)

12

343

4116

... More
Internal Earthing Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

12

7432

89184

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

80

247

19760

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

140

244

34160

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

150

70

10500

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

50

1162

58100

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

7472

29888

... More
Supplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels

2

2400

4800

... More
Supplying , fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)

2

4700

9400

... More
FIRE EXTINGUISHERS

-

-

-

... More
Supplying and fixing approved make fire buckets of 24 gauge galvanized steel sheet with 4 no sand buckets, standard 9 liters capacity as per IS:2546:1974 and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 4 buckets).

1

9500

9500

... More
Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.

6

9500

57000

... More
PORTABLE FIRE EXTINGUISHERS 'Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity

6

4500

27000

... More
Fire Alarm

-

-

-

... More
Wiring for fire alarm detector/ call/ hooter/strobe points with 1.5 sq.mm FRLS PVC insulated copper conductor 2 core cable cable un armoured including start and back loop of circuit in in Medium class PVC conduit as where reuired, , suitable GI box etc. as required. note: all items included like Conduit, cable etc

99

1345

133155

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.

1

239225

239225

... More
Supplying, installation, testing & commissioning of intelligentan alog addressable photothermal detector complete with mounting base complete as required.

90

2858

257220

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

9

2726

24534

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

8

3871

30968

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (make suitable for existing FAP)

8

3506

28048

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. (make suitable for existing FAP)

8

3003

24024

... More
LA System

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 100 cm with three prongs long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. Insulated base plate including holes etc. complete as required.

3

1950

5850

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

100

113

11300

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

100

247

24700

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

12

7472

89664

... More
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.

55

5800

319000

... More
Providing and laying in position of cement concrete M(1:2:4) in RCC for all types of structures including proper vibration and curing including broom finish if required including cost excavation, backfill etc of formwork and reinforcement etc all complete as per direction of EIC.

1

7000

7000

... More
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 100 Amp 25KA 4 pole with MS enclosure (UPS input)

1

10723

10723

... More
Providing and fixing of 5 KVA Automatic Copper wound transformers should have voltage range 120-250 V and out put 220 V with Hi cut, low cut and time delay protections

2

11500

23000

... More
Supply, installation, testing & commissioning of 3.5 kVA 1 phase Inverter with 4x200AH 12V tubuler Batteries including suitable rack, input/output leads/ Switch sockets etc. to make the system operational. Note: Item Should have minimum of two years Warrenty and free service.

2

120375

240750

... More
Providing and fixing modular PVC Modulebox with 32 A MCB and 6 pin 32 A socket outlet combine of reputed make/ as per approval (INV i/p &o/p)

4

640

2560

... More
Providing and fixing 63 MCB type Change over switch with Enclosure

2

1780

3560

... More
Internet/Data Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess wall cutting, wall repairs and finishing as required

-

-

-

... More
1 or 2 Module (75mmX75mm) (LAN/tel)

84

298

25032

... More
4 Module (125mmX75mm)

12

343

4116

... More
Supply, fixing, Testing, commissioning of Wall Mount Rack - 6U 550 W x 450 D Specification Conforms to DIN 41494 OR equivalent ISO Standards. Front Glass Door (tinted, Toughened) with Lock & Key,2 pairs of 19" Mounting Rails with U-Marking. Welded to Frame Top and Bottom Cover, Vented and Field Cable entry exit cut outs UL Certified. Standard Accessories: 1U Cable Manager (1), Hardware Pkt of 20 (1 Pkt). 6 Socket 5 Amp. Power Distribution Unit (1 No) Roof Mounted Fan Unit / 90 CFM /230V AC (1 No). Standard Color : Grey, Static Load : 40 kgs

3

7800

23400

... More
Supply, Installation, testing & commissioning of CAT6 UTP Patch Cord – 3M Specifications: Features Category 6 Equipment cords, he work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling, Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring, Should have 50 micrinches of gold plating over nickel contacts, Should be covered by ETL verification program for compliance with TIA 568.C.2 , Mechanical : Cable Conductor size: 24 AWG stranded bare copper, Max O.D.: 5.6mm (.22”), Jacket: PVC UL-94V-O, Temperature range: -10oC t+80oC, echanical Characteristics – Plug Operating life: Minimum 750 insertion cycles, Contact blade: Phosphor bronze, Contact plating: 50µ” Gold, Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7, Approvals: UL 444 for copper conductor , Operating life: Minimum 750 insertion cycles, Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC, insolation résistance : 35 M Ohm (Max), Operating temperature: -10oC t80oC

40

310

12400

... More
Supply, Installation, testing & commissioning of CAT6 UTP Patch Cord – 1M Specifications: Features Category 6 Equipment cords, he work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling, Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring, Should have 50 micrinches of gold plating over nickel contacts, Should be covered by ETL verification program for compliance with TIA 568.C.2 , Mechanical : Cable Conductor size: 24 AWG stranded bare copper, Max O.D.: 5.6mm (.22”), Jacket: PVC UL-94V-O, Temperature range: -10oC t+80oC, echanical Characteristics – Plug Operating life: Minimum 750 insertion cycles, Contact blade: Phosphor bronze, Contact plating: 50µ” Gold, Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7, Approvals: UL 444 for copper conductor , Operating life: Minimum 750 insertion cycles, Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC, insolation résistance : 35 M Ohm (Max), Operating temperature: -10oC t80oC

84

200

16800

... More
Supply,fixing, testing and commissioning of 24 Port manageable Switch Switch Hardware Specification: Switch with at least 24 X 10/100/1000 Mbps Ports and 4 x 10G SFP+ Ports, 1 x RJ-45 Console Port & 6 kV surge protection on all Ethernet ports, Switch Should Support Link status detection, Port and LED shut-off, System hibernation Switching capacity should be 110Gbps or higher or non-blocking architecture. Switch packet forwarding rate should be 85 Mpps or higher or non-blocking architecture. Switch MAC table should be at least 16K or higher. Support for the Energy Efficient Ethernet (IEEE 802.3az) standard. Power input should be 100 to 240 VAC, 50/60 Hz, internal power supply. Power Saving (Green) Operating temperature should be -5 degree celsius to +50 degree celsius. EMI Certificate - CE, FCC/IEC and SAFETY Certificate - CB/ UL. Switch Software Specification Should support Head of Line blocking prevention for lower latency and better performance. Support Jumbo Frame up to 12K Bytes or higher. Should support IGMP Snooping, Able to create 250 or more IGMP groups and require support for IGMP Snooping Fast Leave,IGMP Snooping Querier Should support MLD Snooping, Able to create 250 or more MLD groups, Per VLAN MLD Snooping and require support for MLD Snooping Fast Leave. Link Aggregation LACP 802.3ad: Minimum 8 groups per device and 8 ports per group Port Mirroring : One-to-One / Many-to-One Switch Should Support Access Control List based on (ACL's) 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles / Rules: 50 / 768 Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol. Should support Spanning tree Root restriction Should support Loopback detection (LBD) to detect the loop created by a specific port. Should support Multicast Filtering to filters or forward all unregistered groups. Switch should support IEEE 802.1Q VLAN tagging for Ethernet frames. Different type of VLAN like Port based, Auto Surveillance, Auto Voice, Asymmetric Vlan etc. should be available for configuration. Switch should support QoS (quality of service) IEEE 802.1P for traffic prioritization. It should support 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin. Port based ingress / egress rate limit function should be available with limit in increments as low as 16 Kbps Switch should support Neighbor Discovery (ND) protocol for IPv6. Switch should support to create atleast 4 IP interface Should support default routing and static routing with minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries. Support at least 700 rules shared by IPv4, MAC, and IPv6 & Each rule can only be associated with a single port. Should support port security to secures the access port based on MAC address. should have broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. Support Traffic Segmentation to restricted traffic flow from a single or group of ports, to a another group of ports. Should have SSH and SSL for IPv4 and IPv6. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan and TCP SYNFIN. Should support 802.1X port based authentication. Should support ARP spoofing prevention. Should support DHCP snooping and DHCP server screening. Switch should able to create a binding table for IP + MAC + Port to prevents a malicious user from spoofing or to restrict the unauthorized users. Should support 802.1X RADIUS and local server database authentication. Should have option to check the status of copper cables using the cable-diagnostics time domain reflect meter (TDR). Able to manage trough Web-GUI, CLI, Telnet & SNMP Should support SNMP v1, v2c, v3 and SNMP Traps and Remote Monitoring (RMON). Should have dual Image support to reduce down time for the switches. Switch should support dynamic host configuration protocol (DHCP) auto configuration of multiple switches through a boot server eases switch deployment. Should have SNTP/NTP protocol for time synchronization. Should support Link Layer Discovery Protocol (LLDP) and LLDP-MED. Note Switch should be supplied with the all necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above mention feature set from day 1. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards.

3

28000

84000

... More
Supply, testing and commissioning of Access Points IEEE 802.11b/g/n/ac/ax, Wifi-6, 2x2+2x2 , PoE (802.3at) Access Point, Data Signal Rate Up to 1800 Mbps Access Point should have Wi-Fi: 802.11a/b/g/n /ac/ax, 802.11d & 11h, EAP, EAP-TLS, EAP-TTLS/MSCHAPv2, PEAPv0/MSCHAPv2, PEAPv1/EAP-GTC, EAP-SIM Supports enhanced security – WPA/WPA2/WPA3 Personal and Enterprise, RADIUS client, and Cipher negotiation Access Point should have Interface Power Jack, Factory Reset Button, console port and LAN ports (PoE) Access Point should support Network Management: HTTP, HTTPS, Software Controller, Hardware Controller, SNMP Support, Telnet, Email Notification, Secure SSH Telnet. Access Point should allow auto fallback data rate for reliability, optimized throughput and transmission range Certifications - FCC, CE. Access Point should support Min Four Dual Band Internal Antennas: - 3 dBi (2.4 GHz), 4 dBi (5 GHz) and Maximum Output Power 22 dBm (2.4 GHz), 24 dBm (5 GHz) Access Point should support Wireless Resource Airtime Fairness, Connect Limit, Aging out, ACL RSSI and Band Steering, Wireless MAC ACL, WLAN Partition Support ARP Spoofing Prevention, Wireless Intrusion Protection, Bandwidth Optimization Access Point should support MAC-based access filtering and WLAN partitioning, Wi-Fi Multimedia Quality of Service (QoS), Traffic Control Uplink and Downlink limit, Access Point should show Ethernet traffic statistics and WLAN traffic statistic, Access Point should support Load balancing to optimize performance between Access Points Note Wi-Fi AP should be supplied with the all necessary components like wall and ceiling mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above mention feature set from day 1.

2

26000

52000

... More
CAT 6 end termination on both sides as per requirement

84

421

35364

... More
Providing and fixing of INDOOR 4U RACK • Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of Mounting Rails with U-Marking,Welded Side • Dimensions: as per standards for NRV cabeling

2

5200

10400

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the H class PVC conduit as required. conduit included ) wall cutting, wall repairs and finishing as required 1 run of cable

1836

102

187272

... More
Supply, both side termination and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. D-link Single outlet faceplate with RJ-45 jack

84

510

42840

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

30

128

3840

... More
25 mm

50

145

7250

... More
LT Network

-

-

-

... More
Supplying and errecting of 0.05 ACSR LT conductor in all respects

360

97

34920

... More
Providing fixing of Shackle LT insulators including clamping duly painted clamps nuts and bolts what so ever required to install insulators

20

450

9000

... More
Providing fixing of GI pole mount muki clamps with nuts and boltsetc.

20

450

9000

... More
Providing and fixing of GI earthing and continuity conductors of G.S.S to panel boards and equipments as per Indian Electricity Act.

1

5000

5000

... More
Supplying , errecting of of 7.5 meters height with base plate/ top cap etc. and should be planted 1.25 meters deep concerted in M15 mix including cost of block above the ground level around the SST pole (0.5 meters x 0.5meter dia.) in same concrete mix with finished plaster dully curried as per site requirement complete. including duly paint coating for street lights

5

15800

79000

... More
Supplying and erection of stay set complete (galvanised) with19/20mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size

2

8500

17000

... More
Street lights

-

-

-

... More
Providing and Fixing of lighting fixture pressure die-cast aluminium IP66 roadway luminaire with high power LED(45W) as light source with toughened glass applicable BIS Standards and ISI Marks etc. Certification: LM79-08, LM80, L70, NABL etc.

22

6200

136400

... More
Providing and fixing of MS Painted outdoor luminary arms for holding 1 no luminary (as per site requirement) and duly fitted on the pole with clean Welding job i/c Supplying/ Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works and anti-corrosive Bitumastic paint of approved brand and manufacture to give an even shade. two or more coats work as per requirement.

22

1500

33000

... More
LT CABLE NON DSR ITEMS Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un moured, served, sheathed 1100 volts grade. having ISO 9001/14001 marks etc.

-

-

-

... More
16 sqmm 2 core

30

229

6870

... More
6 sqmm 2 core

525

148

77700

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required ( Upto 35 sq. Mm)

555

387

214785

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 63 mm dia (OD-63 mm & ID-51 mm nominal) ( for pole foundation )

40

127

5080

... More
Design, fabrication, supplying to site of installation, testing and commissioning of 4 meter height above ground level M.S. Tubular steel/ GI poles/ of 100 mm dia steel pipe with suitable size of reducer for fixing light fixture i/c Supplying/Applying priming coat with ready mixed red oxide Zinc chromate primer of approved brand and supplying&applying anti-corrosive Bitumastic paint of approved brand and manufacture to give an even shade. two or more coats work as per requirement. suitable cable entry space as per requirement and standard design i/c base plate for 4 no. places to insert bolts

22

6500

143000

... More
Providing & Laying of cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size)for G I poles 18”x18”x36” (2'' below ground level) i/c cost of plaster the outer surface with frame work curing, shuttering and anti-corrisive Bitumastic paint two coats etc. with anchor bolts structure or set righting of existing pole for mounting pole in proper way. Foundation size may varry as per site requirement

22

3500

77000

... More
Providing and fixing of suitable size IP 65 or equivalent protected Cable Junction Box for poles 16/6 sq mm terminal block with water tight cover and suitable cable entry space as per requirement and standard design with 2 coatts of anti-corrisive paint Note:-(i)Cost of termination of incoming and out going cable in pole box shall be include with the above item.

22

1200

26400

... More
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole

22

256

5632

... More
Wiring for light pole alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, 2 core cable ISO Certified. 2 CX 1.5 sq. mm

168

70

11760

... More
Supply, installation, testing and commissioning of main control LT. cubicle type totally enclosed, double door, out door type standing type (stand height 1 meter), dust, damp and vermin proof LT. danger notice plate, connection of incoming and out going cables with thimbles, stove enameled painted and having following incoming/ outgoing MCB , meters, indicators and bus bar arrangements complete as required including bottom concreated etc in all respects as per site requirements. with:- a) 1 no. 63 Amp MCB C-curve b) 1 set 63 Amp busbar 2 strip heavy duty aluminum basbar. c) 0-500volt volt meter d)meterswitches. e)3no x 32 Amp DP C- curve MCB 240 /415 V, 10 kA, “C”-curve, MCB. f) Panel light with door switch arrangements. g) 1 no Astronomical Timmer with 3 P 40 Amp Contactors

1

34510

34510

... More
Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.