Small Scale Industries Development Corporation Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Small Scale Industries Development Corporation Limited - SICOP Tender
Eprocure
Opening Date4 Sep 2020
Closing Date25 Sep 2020
Tender Amount₹ 92,50,000
Costs
EMD
₹ 1,85,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Supply Installation Testing And Commission Of 120 Watt Led Street Lighting And 200 Watt High Mast Lights At Newly Developed Industrial Estate
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_SICOP_103560_1Tender No
20-PES of 2020 dated 04-09-2020Tender Authority
Small Scale Industries Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.jksicop.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of 3 Core 1.5 Sq mm single core Copper wire from fixture to connection box along with necessary lugs etc. Complete Job.
615
-
-
Pole Bracket
Fabrication, supply, installation and fixing of pole bracket made out of 38 mm dia G.I pipe medium class 1.5 Mtr long including accessories including bending the pipe to the required shape, 2 no.s 40mm x 3mm flat iron clamps with suitable size nuts , bolts and washer, painting the flat iron with primer and finish paint etc as required suitable for fixing of 120 W LED luminary a)Single Arm
65
-
-
b) Double Arm
8
-
-
G.I Pipe for Cable Protection along pole(Vertical Length)
Supply, bending, threading and fixing of G.I pipe class-B, 40-
50mm dia, 3M long along the pole for protection of cable. The top end of the pipe be threaded suitable for fixing of connection box. The pipe is to be suitably bended to size for smooth entry of cable not less than 12 times the diameter of pipe as per diagram and complete job in all respects.
150
-
-
Cable
Supply, laying, Testing and commissioning of11 KV grade
Aluminum conductor, PVC insulated, PVC sheathed, steel
armored cable 0.75M below ground including digging of trench 0.35M wide 0.75 M depth and refilling the trench, including sand and brick etc as required complete Job.
a) 4C 10 Sq mm
2590
-
-
4 16 Sq mm
1280
-
-
2 C 16 Sq mm
975
-
-
4 C 50 Sq mm
650
-
-
Supplying and fixing 5 Amp to 32 Amp rating 240 Volt “B” series Miniature circuit breaker suitable for lighting other load of following poles in the existing MCB DB complete with connection testing and commissioning etc as required.
a) Single pole 6 to 32 amp
65
-
-
Cement bottoming of poles for street lights in ration of 1:3:6 mix withn2’x2’x2.5’ cement block.
65
-
-
The Pole to be painted with one coat of primer and two coats of silver white aluminum paint.
65
-
-
S.P.F & Connecting Connector 63 AMP 4Pole.
65
-
-
Providing and fixing of Aluminum lugs of required
200
-
-
Servo Stabilizer
Fabrication, supply, erection, testing and commissioning of 20 KVA 3 phase servo controlled automatic voltage regulator transformer with following specifications.
input voltage 100-260(PN)242-450(PP)
Output Voltage 400V+/- 1%(PP)
230V +/-1%(PN)
Oil Cooled
Un-balanced type
Protection: over load and short circuit protection
Voltmeter: 0-300V (AE) make separately on each phase.
Ammeter with selector switch with CT’s Auto manual switch to operate the stabilizer manually in case of
some defect in the automatic circuit. The stabilizer shall be provided with first filling of fresh transformer oil.
Sheet gauge used for fabrication of stabilizer should not be less than 14 SWG
Capacity of auto variable transformer (Varriac) should not be less than 40 Amp.
Speed of correction should not be less than 20-30 volt per
second efficiency more than 90% . Copper wound
2
-
-
G.I Pipe Earthing.
Earthing with G.I earth pipe 4.5 Mts long 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
10
-
-
G.I. Pipe for Road/ Gate Crossing.
Provided and laying of G.I.Pipe class-B for gate/road crossing 0.75 M below ground etc after excavation and back filling the same by way of sand cushion and p/l of RBM 9” thick, two coats of grade II and top p/l cement concrete in mix 1.1.5.3 at the top of road/ gate crossing as required complete job.
a). 75mm
140
-
-
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc, with charcoal and salt as required.
4
-
-
Fabrication, wiring, supply, installation, testing and
commissioning of front operated double door floor mounted cubical outdoor type panel board made of 165Wg, Ms sheet painted with two or more coats of enamel paint over two coats of primer complete with earthing bus, neutral link, drilling holes, on the board and consisting of the following:-
MCCB 125 Amp 4 pole– 2 No.’s Make ABB Legrand 100 Amp Change Over 4pole Make ABB Legrand
MCB 4p 63A – 5No. Make ABB Legrand
Contractor ML2 – 1No. Make ABB Legrand
Electronic Timer – 1No. (astro type switch)
Push Bottom – 2 No.’s
Toggle switch – 1No.
Bus-Bar, Aluminum bus bar 100 A-1 set, Volt meter (0-300v)-
1No, phase indicator R/Y/B- 1set
2
-
-
SITC of feeder pillar with 4 pole TPN with 4 pole bus bar with required size 6/32 Amp DP as per site requirement with thimbles complete job as required
4
-
-
Laying of cable including cost of carriage of sand and bricks (0.75 mm blow ground including digging of trench 0.35M wide 0.75M depth and refilling the trench including sand and bricks etc and as required complete job.
5400
-
-
Supplying installation testing and commissioning of high mast light comprising high mast shaft in 2 segments 12.5 mtrs bottom dia 360mm/top dia-100mm no. of sections -2 section length 65mm 6500mm each section thickness
18. 3mm/base plate-520x16mm 1.no
19. Head frame (2/3) wire system 1.no
20. Double carriage winch 1.no 21. Double drum winch 1.no
22. In winch power tool 3-phase 0.75Hp.06 pole single speed 1.no
23. Chain / sprocket 1no
24. Winch mounting plate 1.no
25. Resting arm 1.no
26. Lightning final 1.no Integral drop cable 5 core- 2.5 sq mm 1.no
27. Wire rope,6mm-2/3 wire system 1.no
28. Cast Al. junction box at lantern carriage 1.no
29. Plug and socket 1.no
30. Necessary fasteners 1.no
31. Foundation bolts M24x1100 (51 mass) 1.no
32. Anchor plate+ template
33. Aviation obstruction light (single dome) led
34. FR PVC 2.5 sqm wire for wiring of fixtures and FP
20)P/F of GI earthing to above system 2nos
22) Civil foundation for above high mast as per manufacturer drawing 1complete job
2
-
-
Supplying installation testing and commissioning of 200 Watt LED high power halogen light including nuts and bolts complete connection as required
12
-
-
Part (A) voltage stabilizer section
Servo motor operated automatic voltage stabilizer for unbalanced input voltage and unbalanced output load having following specification- (z) Input - 160-460 volt AC three phase, (aa) Output - 400 volt AC three phase, (bb) Stability- + 3% , (cc) Frequency- %) HZ + 3%, (dd) Ambient temp- minus 10deg to 40 deg, (ee) Cooling natural air cooled, (ff) Speed of correction 20V/sec, (gg) Efficiency- more than 95% (hh) Operation - automatic/manual (ii) Duty cycle- continuous (jj) Construction-out door (kk) Capacity- 6-KVA (3 phase) (ll) Indication- main indicator in each phase, out put on and output trip indication. (mm) Display & control card- three nos. micro controller based software driven static digital cards with digital display of input and output voltage ,low/high voltage indication, low/high cut off indication overload trip and display of time delay function (nn) Protections-automatic low/high voltage cut off electronic overload and short circuit tripping on each phase in the output (oo) MCB- 32 amp TPN MCB shall be provided at the input of the stabilizer (pp) Bypass arrangement – stabilizer shall be provided switching circuit to operate direct on line in case of single phasing/faults. Surge protection – surge protection device type 2,20 Ka shall be provided as per IEC 61643-11 2011 (qq) Testing standard – IS 7815& IS 2026 (rr) Line filter protection – three phase four wire single stage line filtering as per IEC-60939-I &II, CSA-C22.2 NO.8-13 &UL 1283.shall be provided in the output of the AVR (ss) Mounting – base/stand (tt) Power components- three nos. motorized copper wound auto variable transformers as per IS 5142 (uu) Termination – suitable termination shall be provided for input and output connections (vv) Time delay in the output- (A) at the time of switching off- 0-5 sec adjustable. (B) at the 6time of switching ON – 10 sec.-2.5 minute adjustable (ww) Time delay at the input – A time delay relay of 5 to 10 minutes (adjustable) shall be provided at the time of switching ON the input supply to the stabilizer through TP contactor of 18 amp[s capacity (AC 3 duty) with a coil voltage range of 100-250 V Part-B timer and motor control section
Control penal to regulate the mains supply to high mast light and reversing motor consisting of following components accessories. (k) 32 amps TPN MCB at the input supply of the penal 1 no (l) 3-pole contactor of 18 amps capacity 1no Quartz timer with 24 hour setting ,base/DIN/Flush mounting type with a battery backup time of 150hrs 1 no (m) Three phase over load relay 4-6 amps capacity 1 no
n) One pole 2-way switches with centre OFF position for auto/manual operation of switching ON-OFF of MAST light. 1 no (o) Mains indicator R,Y,B to indicate availability of mains supply. 3 no (p) Push button switches for forward/reverse control of motor. 2no (q) 18 amps TP contactor (240 V) for forward and reverse motion of the motor 2nos, (r) Indicator for forward/reverse operation of motor. 2nos (s) Approximate dimensions of the penal for housing voltage regulator and control penal 900mm(W)x750mm(H)x450mm(D t) Approximate total weight of the complete unit 1980kgs
xx) The entire assembly of servo stabilizer, timer and motor section shall be housed in a double door sheet steel enclosure of 1.2 mm SWG duly powder coated for outdoor application. Make(IECO/L&T/Schneider/jai ma/Siemens/ABB)
2
-
-
Evaluation Notes How It Works ?