Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date13 Mar 2019
Closing Date18 Mar 2019
Tender Amount₹ 32,00,000
Costs
EMD
₹ 64,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PDD_72765_1Bid Award Id
ViewTender No
e-NIT 70 of 2018-19Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site , Laying , stringing, tensioning and binding of 30 mm2 ACSR Conductor , including joints by PG clamps wherever required.(conductor to be supplied by deptt)
13.5
-
-
Cement bottoming of S T poles in 1:2:4 mix as per REC standard 0.5/0.45 cum/pole, muffing 20 cm above ground, including plaster and curing of concrete.
200
-
-
Supply and Painting of poles with one coat of redoxide and two coats of Aluminium paint of standard quality.
200
-
-
Supply and Erection of Galvanized stay set complete with 50 x 8 mm stay clamps, guy insulators 02 nos, anchor plate (200 x 200 x 6 mm), nut bolts ,02 No turn buckle ,1.8 m long, 16 mm dia solid GS rod & 7/3.15 mm dia G.I stranded wire complete.
120
-
-
Supply and fixing of pole Earthing by G.I pipe 40 mm dia or G.I rod 20 mm , 2.5 mtr long through GI strip.
90
-
-
Supplying and fixing of pole Earthing Complete by GI Spiral Earthing, 8 SWG 115 turn coil earthing as per REC Standard
110
-
-
Supplying and Fixing of Danger Plates with clamps with writing in English and Regional Language
200
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 3.5 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose.
200
-
-
Supply , and fixing of GI “V’ cross-arm (75x40x40x6)mm with Pole Top Bracket including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.
825
-
-
Fixing of GI “V’ cross-arm (75x40x40x6)mm with Pole Top Bracket including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure.(Material to be supplied by the Dept.)
825
-
-
Supply and Fixing of GI channel 2140 mm long (75x40x40x6 mm) cross arms for H-frames, GI Angle (50x50x6) cross braces for H-frames with back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers as per REC standard.
1240
-
-
Transportation ,Fixing of GI channel 2140 mm long (75x40x40x6 mm) cross arms for H-frames, GI Angle (50x50x6) cross braces for H-frames with back clamp/Collar clamp of 50x8 mm duly drilled with installtion of GI nuts & bolts,washers as per REC standard.
1240
-
-
Supply , and fixing of GI channel/angle/ flat of sizes including clamps for substation . ( GI channel iron cross arms 100x50x50x6mm- as per REC specification and standard , (2 No) 75x40x40x6mm- as per REC specification and standard (7 No) , 50x50x5mm Transformer belts (02 No) (as per REC specification and standard.)
900
-
-
Fixing of GI channel/angle/ flat of sizes including clamps for substation . ( GI channel iron cross arms 100x50x50x6mm- as per REC specification and standard , (2 No) 75x40x40x6mm- as per REC specification and standard (7 No) , 50x50x5mm Transformer belts (02 No) (as per REC specification and standard.) (Material to be supplied by the Dept.)
900
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Siteand installation of 100KVA/63 KVA/25KVA, 11/0.433 kV Distribution Transformer,Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (Note: The transformer to be provided by JKPDD).
3
-
-
Supply & installation testing commissioning of 11 KV 3 -phase 3 pole , 200 Amps G.O AB Switch complete with all accessories as per REC standard
3
-
-
Supply and installation , testing ,commissioning of 11KV 3 - phase , 100 Amps D.O Fuse set (post insulator type) confirming to ISI specification
3
-
-
Supply and installation, testing ,commissioning of Gapless Surge Arrestor set (Stn. type) confirming to REC specification ,having rated voltage 9 Kv Rms , with discharge current of 10 K-amps with polymer/porcelain housing, Stn type.
3
-
-
Supply & fixing ,testing, commissioning of 11 KV Disc. Insulators 45 KN (Polymer) with fittings as per REC specification.
120
-
-
Supply and Fixing of LT Struture of GI Angle Iron 50x50x6)mm 2/3 ft long, Flat Iron /Pole Clamps 40x6 mm,16 mm bolt dia. Note;Distance between shackle to shakle=30cm , clamps to be 25mm more than dia of top pipe of pole
1250
-
-
Fixing of LT Struture of GI Angle Iron 50x50x6)mm 2/3 ft long, Flat Iron /Pole Clamps 40x6 mm,16 mm bolt dia. Note;Distance between shackle to shakle=30cm , clamps to be 25mm more than dia of top pipe of pole
1250
-
-
Fixing of LT Structure Single shackle set (Mukhi Type) as per REC standard.
250
-
-
Supply & fixing, testing ,commissioning of LT shackle Insulators 16KN as per REC specification.
250
-
-
Transportation, loading ,fixing, testing ,commissioning of LT shackle Insulators 16KN as per REC specification.
250
-
-
Supply & fixing, testing ,commissioning of LT GI U Clamps as per REC specification.
250
-
-
Transportation, loading ,fixing, testing ,commissioning of LT GI U Clamps as per REC specification.
250
-
-
Supply & installation of Fixing of LT fuse set with connectors , LT insulators mounted on Angle Iron 45*45*4mm frame as per REC standards.
3
-
-
Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth. (Note: For LA Earth 1 pipe shall be kept separate)
6
-
-
Supply & installation ,testing , commissioning of 11 KV Pin Insulators (Porcelain) with pins 5KN as per REC specifications.
150
-
-
Transportation loading,Installation ,testing , commissioning of 11 KV Pin Insulators (Porcelain) with pins 5KN as per REC specifications.
150
-
-
Supply & laying, testing ,commissioning of 120mm² 1-core PVC 1.1 KV grade aluminium cable FRLS type. ( Havells /Equivalent make )
120
-
-
Supply and installation of LT bi-mettalic connectors for making connection from DT bush rod to aluminium cables as per REC standard
24
-
-
Supply & fixing of GI nuts and bolts of sizes
260
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of Single Phase smart/pre-paid Energy Meter 5-30 Amp / 10-60 Amp
(Note: The meters shall be provided by Dept.)
90
-
-
Fixing of 10 mm²/16 mm² Cable (2C) from LT Line to meter, 1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type (Note: The cable shall be provided by Dept.)
900
-
-