Power Development Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Eprocure
Opening Date1 Jun 2018
Closing Date22 Jun 2018
Tender Amount₹ 41,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Handling, carriage from Divisional stores Sopore, Assembling, Installation, Testing & Commissioning of 11 KV Panel Board with VCB ,800 Amps with CTR 600-300-150/5-5- 2.89 A, 3-Core CT for 1 (Incomer Panels) and CTR 400-200/5- 5 A, 2-Core CT for 5 Outgoing Panels with all numerical relays on IEC-61850 protocol, Ammeter, Voltmeter, Energy Meter dlms compatible with RS 485 port , Lamp Indicators, complete with Terminal Blocks and wiring . The DC voltage shall be as per the system to be installed in this particular upcoming Rec Stations.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 33KV Isolator, 1250 Amps, three pole Break, Centre Post rotating, air break O/D without Earthing Switch, including Terminal Box and Auxiliary Switch ( Horizontal alignment)

2

-

-

... More
Supply, Installation, Testing & Commissioning of 33KV Isolator, 1250 Amps, three pole Break, Centre Post rotating, air break O/D Earthing Switch, including Terminal Box and Auxiliary Switch ( Horizontal alignment)

2

-

-

... More
Supply, Installation, Testing & Commissioning of Current Transformers, Outdoor Type, 33KV, 3 core with CTR 250-125/5-5-5 A as per specification (1Set shall mean 3 No's)

2

-

-

... More
Supply, Installation, Testing & Commissioning of Surge Arrestors Station Type,30KV Grade, Non Linear Resistor Type, as per specification.

3

-

-

... More
Supply, Installation, Testing & Commissioning of Voltage Transformers, Outdoor Type, 33KV/110v, as per specification (1Set shall mean 3 No's)

1

-

-

... More
Supply, fabrication and installation of bus bar in outdoor yard for 33 kV Bay using All Aluminum conductor 200mm from transformer to incoming bay. The cost shall include aluminum alloy pads/Tclamps of required sizes, Tension fittings and Disc insulators, Post insulators as per specification / practice in vogue for Line and transformer bay

1

-

-

... More
Supply, Installation, Testing & Commissioning of Multistranded Control Cables & accessories (Glands, lugs, ties , nuts and bolts, ferrules etc) : 12 Core,10 Core 8 Core, 6 Core, 4 Core, 2 Core, Multicore 2.5sqmm Copper, FRLS armoured inner/outer sheath for all the equipment's and Suitable loops shall be provided at both ends for each cable run. This shall include cost of cable glands. one lot means complete controle cabling in the Receiving sub station

1

-

-

... More
Supply, Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 400 sqmm with supply of Heat shrink cable termination kits (outdoor as well as indoor ).Suitable loops shall be provided at both ends for each cable run (minimum 60 meter length).

60

-

-

... More
Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables,armoured 3C 240 sqmm with supply of Heat shrink cable termination kits ,outdoor as well as indoor.

240

-

-

... More
Supply, Installation, Testing & Commissioning of 11 KV Gang operated Operated Switch, horizontal type with Earthing Blade, Terminal Box & Auxiliary Switch, as per specifications.(11 kv Horizontal type Isolators)

5

-

-

... More
Supply, Installation, Testing & Commissioning of 9 KVSurge Arrestor (station type)

5

-

-

... More
Supply, Installation, Testing & Commissioning of 100 KVA, 33/0.433 KV, copper wound, 3-Ph Auxiliary Sub Station on 2 No ST Pole (to be provided by the Department) Structure complete with all accessories ( including GO set, Dropout fuse,LA,Channels,Extension of earthing/100 Amps MCCB 4 pole 16 KA in outdoor type MS enclosure) . It includes providing of supply circuit at AC Distribution Board by installation 120 mm sq XLPE cable 3½C from SS to AC distribution Board. as perv IS-1554

1

-

-

... More
Supply, Installation, Testing & Commissioning of 25 KVA, 11/0.433 KV, copper wound, 3-Ph Auxiliary Sub Station , Dry type Indoor type ( including ,incomer and out going XLPE 3½C cable ,Extension of earthing/63 Amps MCCB 4 pole 16 KA in outdoor type MS enclosure) . as perv IS-1554

1

-

-

... More
Supply, Installation, Testing & Commissioning of DC system 36 V ( as per site requirement) using automatic battery charger , 20 Amps with trickle and boost charge and maintenance free VRLA batteries 100 AH (2volts x18 No.) , including its mounting arrangement, wiring upto required equipment.

1

-

-

... More
Switchyard Illumination by providing and fiting on 8 meter long Galvinized iron contineously taped polygonal pole , 1x50 Watt LED fittings IP66 including copper armoured wires , 2 core 2.5 sqmm , fittings and junction box , to be laid underground through HDPE pipe conduit of 50 mm dia, .( Output of LED shall be more than 100 Lumens per watt at minimal operating current)

5

-

-

... More
Supply , installation and testing of 10 KVA, single phase LT sero stablizer, oil cooled, with motor control, electronic overload protection,ground fault monitoring with trip indication ,surge supressor, voltage cutt off for servomotor at input and over voltage, auto manual switch , with digital VIF meters , input range 100-280, out put 230volts,

1

-

-

... More
Supply ,Design,drawing, Fabrication and Fixing of Earthing MAT for New Bay: GI Strip 75x8mm including making of butt and lap joints by way of welding/bolting, bending of risers and fixing of same to equipment support structures and equipment earthing points, whereever required with painting(Red Oxide) of joints. Work shall include P/F of Earthing Electrodes manufactured from 19mm dia GI Spikes ( The erathing value should be less than 2 ohms)

20

-

-

... More
Supply ,Fabrication and installation of GI Structures as per Drawing for errection of 33 kV and 11 kv Gantry structure and equipment structures using GI pipes (152mm x 5.9 mm ) , GI 100x50x50x6, 75x75x6mm, 65x65x6mm, 50x50x6mm chanel / angle and 50x6mm flat iron galvanized where ever required including required nuts and bolts. for 33 KV and 11 kv Gantry structure ,ST poles of 11 meter and 09 meter respectively will be provided by the department from Divisional store.

70

-

-

... More
Supply , installation and testing of Fire Fighting Equipment (co2 fire Extinguishers) and Fire Fighting Equipment (3 No. Fire Buckets of 9 ltrs,having round bottom with handle, painted white from inside and post office red clor from outside , bottom is painted black. Filled with sand

1

-

-

... More
supply Al ladder (folded) of reputed make and qualities complying with the suitable grade of IS 617:1975.Straight Extendable upto 30 ft having aluminium channel of 90X30 mm with 63mm wide steps edging non-slippery. A locking device or spreader to hold the front and back section securely in an open position and each pair of side-rails rigidly to one another shall be an integral part of each ladder.

1

-

-

... More
Spply of Analog Oil Test machine ,test sequence as per IEC 60156 / IS6792,, Safety door & Zero start interlock, Memory effect analog voltmeter, Oil Test vessel with electrode gap adjustment facility., Voltage Calibrator for onsite calibration, Voltage Accuracy 1 percent

1

-

-

... More
Desk top computer with standard durable computer Table with Processor - dual core 2.4 GHz+ (i5 or i7 series Intel processor or equivalent AMD) RAM - 16 GB Hard Drive - 256 GB or larger solid state hard drive Graphics Card - any with DisplayPort HDMI or DVI port -Monitor – 23 widescreen LCD with DisplayPort HDMI or DVI support Operating System - Windows 10 Professional editions, (orgional) with 1 kva UPS, with one hour backup Warranty 1 year warranty- Backup Device - External hard drive and or USB Flash Drive

1

-

-

... More
P/l of Construction of Foundation blocks of Transformer bed by way of requisite earth work excavation, centring shuttering works , P/L of Providing and laying of cement concrete of nominal mix M-10 grade (1:4:8) of 4 inch thick, and Providing and laying of cement concrete of nominal mix M-15 grade (1:2:4) with crushed stone aggregate of size 20mm. including all carriages of material from source to site , including Cement mortar 1:4 ( 1 cement : 4 course sand ) 12mm think for Transformer of the required size of (10x10x5)cubic feet, under the guidance of concerned Sub Divisional Engineer, including Back filling/refilling in trenches of available earth in layers in plinth and wherever required ,

1

-

-

... More
P/l of Construction of Foundation blocks of various equipments P/l of Construction of Foundation blocks of equipments by way of requisite earth work excavation, centring shuttering works , P/L of Providing and laying of cement concrete of nominal mix M-10 grade (1:4:8) of 4 inch, and Providing and laying of cement concrete of nominal mix M-15 grade (1:2:4) with crushed stone aggregate of size 20mm. including Cement mortar 1:4 ( 1 cement : 4 course sand ) 12mm think for equipments foundations above ground , including all carriages of material from source to site as per the required size of (10x1.5x5)cubic feet, to be authorized by the concerned Sub Divisional Engineer , including Back filling/refilling in trenches of available earth in layers in plinth and wherever required ,

30

-

-

... More
Providing, placing, bending, binding cutting of Thermo Mechanically Treated (TMT) bars, Fe15 grade for RCC works including cost of binding wire and necessary overlapping.for all equipement foundations

250

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.