Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date22 May 2025
Closing Date25 Jun 2025
Tender Amount₹ 8,48,12,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The eligible class required by a bidder to participate or bid in the tender is 'S' Class, also referred to as "Class 'S'".
Technical Capacity
... View More
The required prior work experience for the bidder includes having successfully completed similar works during the last seven years, which should consist of both Sewer Network and Sewage Treatment Plant work. The criteria for similar works are as follows: - Three satisfactorily completed sewage treatment works/ STP in the last seven years, each costing not less than an amount equal to 40% of the estimated cost or each having a quantity of specific items of works not less than 40% of the estimated quantities of the tender. - Two satisfactorily completed sewage treatment works/ STP in the last seven years, each costing not less than an amount equal to 50% of the estimated cost or each having a quantity of specific items of works not less than 50% of the estimated quantities of the tender. - One satisfactorily completed sewage treatment works/ STP in the last seven years, each costing not less than an amount equal to 80% of the estimated cost or each having a quantity of specific items of works not less than 80% of the estimated quantities of the tender. Alternatively, the bidder should have prior work experience in similar works, which includes works consisting of both Sewer Network and Sewage Treatment Plant work, with the following options: - At least two satisfactorily completed sewage treatment works/ STP in the last seven years, each costing not less than 40% of the estimated cost or each having a quantity of specific items of works not less than 40% of the estimated quantities of the tender. - Alternatively, one satisfactorily completed sewage treatment works/ STP in the last seven years, costing not less than 80% of the estimated cost or having a quantity of specific items of works not less than 80% of the estimated quantities of the tender. - Another option is two satisfactorily completed sewage treatment works/ STP in the last seven years, each costing not less than 50% of the estimated cost or each having a quantity of specific items of works not less than 50% of the estimated quantities of the tender. The estimated cost of the current project is Rs. 848.12 Lakhs. The value of previously completed works shall be enhanced at 5% per year to bring them at par with the present cost. The average annual financial turnover during the last three years should be at least 30% of the estimated cost of the tender.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF SEWAGE TREATMENT PLANT ALONGWITH CONNECTED WORKS INCLUDING OUTSOURCING SERVICES AT ZANGLI UNDER GE 874 EWS
PROVN OF SEWAGE TREATMENT PLANT ALONGWITH CONNECTED WORKS INCLUDING OUTSOURCING SERVICES AT ZANGLI UNDER GE 874 EWS
PROVN OF SEWAGE TREATMENT PLANT ALONGWITH CONNECTED WORKS INCLUDING OUTSOURCING SERVICES AT ZANGLI UNDER GE 874 EWS
PROVN OF SEWAGE TREATMENT PLANT ALONGWITH CONNECTED WORKS INCLUDING OUTSOURCING SERVICES AT ZANGLI UNDER GE 874 EWS
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from Pre Priced Schedule.

1

88070

-

... More
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from Pre Priced Schedule.

1

10124

-

... More
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from Pre Priced Schedule.

1

28391413

-

... More
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDING WORKS as listed in Schedule 'A' Part-V brought forward from Pre Priced Schedule.

1

1367702

-

... More
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from Pre Priced Schedule.

1

419921

-

... More
Lump sum price worked out by the contractor for COMPOUND WALL, FENCING & GATE WORKS as listed in Schedule 'A' Part-VII brought forward from Pre Priced Schedule.

1

247534

-

... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-VIII brought forward from Pre Priced Schedule.

1

2176043

-

... More
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTH WORKS as listed in Schedule 'A' Part-IX brought forward from Pre Priced Schedule.

1

10834477

-

... More
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-X brought forward from Pre Priced Schedule.

1

831441

-

... More
SCH 'A' Part-XI (BUILDING WORKS FOR PLANT ROOM)

-

-

-

... More
Construction of Block of plant room cum duty room cum store with toilet including truss and ramp single storey permanent construction inclding structural designing of building and truss complete all as specified and directed. Note:-The architectural drawings in r/o Block of plant room cum duty room cum store with toilet are part of tender documents and structural design of said Block alongwith of truss shall be carried out by contractor after examining the SBC at site and get the design vetted from any IIT (not by professor in his individual capacity). The work shall be commenced after approval of vetted drgs by Accepting officer. The other details of said building/Block except design which is to be carried out by contractor, shall be followed as per drawings and specifications of CA.

1

-

-

... More
SCH 'A' Part-XII (STP WORKS FOR 120KL/day)

-

-

-

... More
Design, supplying, installation, testing & commissioning of 120KLD Package type Sewage treatment plant with all mechanical & civil works, with suitable heating arrangement based on the technology suggested by the bidders in technical bid best suitable in J&K as per geographic and climatic conditions of site and as per following specifications and complete all as specified and directed. The STP shall consist of all components required for satisfactory functioning of STP. It shall be capable of meeting the output parameters complying with NGT, CPCB / SPCB or DPCC (which ever is stringent). The STP shall be designed for working in minus (-) 10 degree Celcious Temp at Zangli (J&K) at an altitude of 2200m above MSL. The detail design of STP shall be carried out by the contractor and get it vetted from any of the IIT and shall be submitted to GE within 120 days from date of commencement of work (Refer Sch A Notes) stated in Work Order placed by GE. The design submitted by the contractor shall be finally approved by Accepting officer before commencement of STP work. Notes:- (i) The technology being adopted by the contractor shall be best suitable in J&K as per geographic and climatic conditions of work site. (ii) The other components of STP (civil and mechanical works) as per Pre Priced Sch and BOQ shall be constructed by the contractor as per specifications, drawings and as directed. (iii) The design of STP shall be carried out by the contractor after complying the instructions of CPHEEO manual. This endorsement shall be made in approved design and drawings. (iv) NOTE:- Minimum sizes/details/capacity,etc of chambers/tanks, etc are specified in respective Items, to be designed and constructed by the contractor.

1

-

-

... More
Sewage Treatment Plant shall include the following items/components (As the STP will be above ground, the agency has to check the invert level of Sump and accordingly the raw sewage need to be transferred to feed the Plant):- (A) COLLECTION SUMP:- The untreated sewer effluent shall firstly be collected in collection sump. The Collection Sump shall be constructed as per appropraite approved design of contractor. However, min tentative details are:- depth of sump= 5.05 mtr, dia of sump = 2.5 mtr, min capacity of pump = 170 LPM, Nos. of pump = 03 (02 W + 01 S) and dia of raising main from pump = 40mm. The invert levels of collection sump shall be finalised in consultation with GE in accordance with site conditions and proposed sewer line network. (B) STILLING CHAMBER:- The sewage shall be pumped to stilling chambers from collection sump. The Stilling Chamber shall be constructed as per appropraite approved design of contractor. However, min tentative details are :- No. of chamber = 01, L= 0.8 mtr, B= 0.7 mtr and D=1.50 mtr (including free board). (C) BAR/SCREEN CHAMBER:- Two Nos screen chambers (one working and one standby) shall be constructed as per appropraite approved design of contractor and as per specifications specified in CA. However, min tentative details are :- L= 2.00 mtr, B = 0.30 mtr, Depth= 0.20 mtr, Free board= 0.30 mtr, thickness of bar= 10mm, spacing between bars = 12mm, angle of placement of screen = 60 degree, width of side frame = 25mm, slope of chamber = 1 in 10. The sewage shall move to screen chamber from stilling chamber through gravity. The levels shall accordingly be decided as approved by GE. (D) OIL AND GREESE TRAP/GRIT CHAMBER:- Two Nos oil and greese trap/grit chambers (one working and one standby) shall be constructed as per appropraite approved design of contractor and as per specifications specified in CA. However, min tentative details are :- L=2.00 mtr, B=0.45 mtr, D=0.80 mtr (including free board). The sewage shall move to oil and greese trap/grit chamber from screen chamber through gravity. The levels shall accordingly be decided as approved by GE.

-

-

-

... More
(E) EQUALIZATION TANK:- The equalization tank shall be constructed as per appropraite approved design of contractor. However min tentative details :- Volume=42.56 cum, Width=3.20 mtr, Length= 3.80 mtr, Depth = 3.50 mtr (including free board of 0.20 mtr and air grid of height 0.30 mtr). (F) SEWAGE TREATMENT UNIT:- The sewage shall be pumped to STP Unit. The Sewage treatment plant shall be of Package type with 120KLD capacity having microprocessor based control with all mechanical & civil works, with suitable heating arrangement. The STP Unit shall consist of all components required for satisfactory functioning of STP with inlet and outlet sewage characteristics as mention below. The STP shall be designed for working in minus (-) 10 degree Celcious Temp at Zangli (J&K) at an altitude of 2200m above MSL. The basic data about inlet sewage and required for outlet sewage are as under:- (i) Inlet Sewage Characteristics :- pH = 6.5-8.0, BOD = 150 ppm, COD = 500 ppm, TSS = <150 ppm, Inlet Temperature = 8° C, Oil & Grease = < 20 mg/ liter, Fecal Coliform = 10^7- 10^8 MPN/ 100 ml, Total Kjeldahl Nitrogen = 30 mg/liter

-

-

-

... More
(ii) Treated (Effluent) Sewage Characteristics after treatment :- pH = 6.5 - 8.5, BOD = ≤10 mg/L, TSS = ≤ 50 mg/L, COD = ≤50 mg/L, Oil & Grease = ≤10 mg/L, Total Kjeldahl Nitrogen = 5 mg/liter Notes :- (i) There is no embargo on the technology to be used for sewage treatment scheme. Any technology selected for STP should also take accountability of the expertise in the J&K area, Life cycle cost of the STP and intended reuse of treated waste water STP shall be provided as per above mentioned parameters. (ii) The levels of the various treatment units (stilling chamber/screens/grit chamber/equilisation tank etc) shall be decided and provided by the OEM/Contractor on his requirement for the package type STP. (G) TREATED WATER TANK:- Treated Water Tank shall be constructed as per Sch 'A' Part-I. Details are:- Volume = 40 Cum, Depth = 3.50 mtr (including free board), Dia = 4 mtr). (H) AIR COMPRESSOR:- Air Compressor shall be constructed as per approved design by the contractor. Two Nos (one working and one standby). However, min tentative details are :- Capacity = 70 Cum/Hr, Air requirement for equilisation tank = 50.00 Cum/Hr, Air requirement for sludge tank = 20.00 Cum/Hr.

-

-

-

... More
(J) DISINFECTION UNIT :- Disinfection Unit shall be constructed as per details to be designed by the contractor. (K) FILTER FEED TANK & PUMP :- Filter Feed Tank shall be constructed as per details to be designed by the contractor. However, Centrifugal, mono bloc, filter feed pump shall have discharge rate of minimum 6.0 m³/hr at a head of 35 meters 2.0 HP/2900 rpm, along with all interconnecting pipelines, suitable size ball valve at inlet and outlet, Non Return Valve at Outlet, with all fittings and specials required including MS base frame duly epoxy painted and grouted, suitable for operation on 3 phase, 415 Volt , AC supply i/c connections complete etc as required. Qty - 2 Nos. (1Working + 1Standby). (L) MULTI GRADE FILTER (MGF) :- MGF to be comprised of latest IS. (M) ACTIVATED CARBON FILTER (ACF) :- Activate carbon filter to be comprised of IS 2062 Mild steel epoxy painted vassels with butterfly valve in MS frontal pipe works frontal. (N) SLUDGE HOLDING TANK :- The Sludge Holding tank shall be constructed as per appropraite approved design of contractor. However, min tentative details are:- Retention time= 4 hours, Length= 0.80 mtr, Width= 0.70 mtr, Height = 1.25 mtr (including 0.20 mtr free board and 0.30 mtr air grid). (O) INTERCONNECTING PIPING :- Supplying & Fixing of all necessary UPVC & MS Pipes of approved make including valve, fittings & other accessories etc. complete in all respect. (P) MISC:- Rates for all the requisite connected equipments as per design submitted by the contractor for proper functioning of whole STP plant shall be deemed to be included in quoted rates.

-

-

-

... More
(Q) Control Panel for Sewage Treatment Plant : (i) Electrical Distribution Board having controls of STP Operation as per specification mentioned here under: (a) Single Incomer, Non-Compartmentalized non draw out type, Fuseless type, Single front, Top entry, CRCA, RAL7032, Free standing, Floor mounted. Panel make shall be fabricated panel from OEM. (b) Main Busbar : Aluminium, 0.8A/Sq.MM (c) Control Busbar : Copper (d) Earth Busbar : 50 x10MM Al (H), 25x10MM Al (V) (e) Fault level : 50kA for 1 sec. (f) Incomer (Suitable for 54 KW of connected load) : MCCB (3P, TOLR, with U/V) (g) No space heater with thermostat, Illumination Lamp and Door limit Switch to be provided. (h) Outgoing Feeders(3 phase ): MPCB + Contactor (j) Outgoing Feeders(1 phase) : MCB+Relay (k) Others :- 100MM base channel L/R selection considered in MCC No spare feeders considered.

-

-

-

... More
(ii) Power/Control Cable & termination Accessories : (a) Power Cables is to be provided: (aa) 3 Core, XLPE / PVC insulation, Armoured, upto 6 Sq.mm Cu conductor cable. (ab) 3 Core, XLPE / PVC insulation, Armoured, above 6Sq.mm Al conductor cable. (b) Control Cables : 4 Core, XLPE / PVC insulation, Armoured, 1.5 Sq.mm Cu conductor cable is to be provided. (c) Termination Accessories : (aa) Double compression Ni plated brass glands with earth strips to be provided. (ab) Non insulated Al/Cu Lugs of suitable conductor size are to be provided. (iii) Trays with tray supports : (a) Tray material - Hot dripped GI Cable Trays. Make : IEI approved vendor. (b) Types of cable tray - Ladder and perforated type with coupler plates and joining accessories (c) Minimum Sizes to be provided - 2mm thick 600mm(W)X2500mm(L)X50mm(H) - Ladder 300mm(W)X2500mm(L)X50mm(H) - Ladder 450mm(W)X2500mm(L)X75mm(H) – Ladder 150mm(W)X2500mm(L)X50mm(H) - Ladder 100mm(W)X2500mm(L)X50mm(H) - Perforated 50mm(W)X2500mm(L)X50mm(H) - Perforated Hot dipped galvanised MS tray supports are to be provided at regular interval of 2.5mtrs

-

-

-

... More
(iv) LBPS : (a) Make: Vaishno or techno commercially equivalent (b) For manual operation of drives Enclosure - CRCA , MS powder coated with RAL 7032 paint shade, IP65 protection For 3 Phase drives - LPBS with Start/Stop PB with Push release type PB and mushroom head Stop PB with key with 1 NO+1NC contacts for each PB, For 1 Phase drives - Plug and socket (v) Above ground Earthing : (a) As per IS3043- Size is based on short circuit capacity of 50kA for 1sec (b) Cross section of earth strips or wires of suitable sized and body earthing E&I equipment are to be provided. GI strip will be provided as MOC for earthing. (R) Cabling : Suitable size of Copper / Al armored Electrical cabling from control panel to various units of sewage treatment plant as per the capacity of the motors / drives complete as required along with Cable trays.

-

-

-

... More
(S) Instrumentation : Supplying & fixing of following complete as required:- PRESSURE GAUGES – Supply & fixing of Bourdon / Diaphragm type pressure gauges to Indicate the Pressure having range of 0 to 4 Kg/ cm2 for Pumps & 0 to 1.0 Kg/cm2 for Blowers as required. LEVEL Switches – Supply & Fixing of level switches to Indicate the low & High level inside the tanks as required. ELECTRO MAGNETIC FLOW METER - Supply, Installation, testing and Commissioning of Electromagnetic Flow meter 1.5" line size. Suitable for 2-10 m3/hr with flow rate for sewage water. Indicator ; enclosure – cast aluminum, weather proof IP-65; mounting- field (direct on sensor); supply power- 230 volt ac as required- 02 Nos. (01 for inlet & 01 for outlet) (U) Insulation of Package Sewage Treatment Tank with glass wool having density of 24 kg/cm² with minimum thickness of 50 mm with aluminium cladding with 0.8 mm thick sheet. (V) Flushing Tank shall be constructed as per details to be designed by the contractor and as directed.

-

-

-

... More
NOTE :- The rate quoted by contractor shall include the following:- (a) M&L for Heating and insulation for complete STP unit and Equalisation tank as specified and directed. (b) M&L for all Chemiclas required for plant operation/first run, initial filling of lubricants & Lab test certifate, analysis report of water samples during pre commissioning and post commissioning of plant should be provided by contractor. (c) 1 Lot of foundation for Pumps, Blowers and other equipments as required in PCC and starters. (d) Suitable Temperature control measure insulation of pipeline and heating arrangement shall be adopted for winter season upto (-) 10 degree celcius at altitude of 2200 mtr. (e) Contractor has to submit all the requisite drawings & technical specifications duly vetted by IIT through GE and to be approved by Accepting officer before commencement of work. (f) Contractor has to submit drawing & technical specification of LT Panel through GE before placing order for approval of Accepting Officer. (g) Pre painted galvalume aluminium zinc coating GI bassed corrugated steel sheet 0.50mm thick with mild steel framed structure including two coats of synthetic enamel paint over a coat of red oxide primer including necessary welding, base plate, gusset plate, excavation, RCC work in foundation. Foundation design shall be based on load bearing capacity of soil at a depth of 1.5M from GL covering from bar screen chamber to activated carbon filter (ACF) having both side slope of 1 : 3 with clear height 3 Mtr on all sides and 1.50m clear space on all sides from civil structure 60 mm thick machine pressed precast concerete interlocking paver block any slope and size M-35 Grade over 50mm thick sand cushion to be laid at 1.5M clear space on all sides from Civil structure. The structure will be designed for loading as per IS 800, the design will be get approved by Accepting Officer before work commenced. No side cladding is required.

-

-

-

... More
SCH 'A' PART-XIII (SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEM)

-

-

-

... More
Designing, Supplying, Developing, Installation, Integrating, caliberation and Commissioning of SCADA System suitable for STP 120 KLD and Lift well pump house and including control panel, electromagnetic online flow meter with data logging range 0 - maximum five times of anticipated flow in cum/hr for specified pipe and Multi Parameter analyser or online continous effluent monitoring system (COD, BOD, TSS, pH, Ammonia, temp) having monitor with display and data logging for treated sewage effluent with all accessories as follows complete all as specified and directed:- RACK 8 CHANNEL 1 No. BMX PROCESSOR 1 No. BMX POWER SUPPLY 1 No. BMX 32 DI CARD 1 No. BMX 32 DO CARD 1 No. BMX 8 ANALOG INPUT CARD 2 Nos. ETHERNET SWITCH 1 No. BMX CABLE 3 MTR 4 Nos. BMX ANALOG CONNECTOR 2 Nos. LUX, FERRULING, MOUNTING PLATE, DIN RAIL, TERMINAL BLOCK CABLE TIE 1 LOT SCADA 1 No. ENGINEERING & SERVICES 10 DAYS ON SITE 1 No. ELECTRICAL PANEL ENCLOUSER SELF FABRICATED 1 No. SCADA CITECT STUDIO 500TAG 1 No.

1

-

-

... More
i5 COMPUTER WITH 4GBRAM, 1TB , 32'' MONITOR 1 No. UPS 1KVA BACKUP 1 No., Colour Lasor Printer - 01 No. COD, BOD,TSS MONITORING DISPLAY WITH DATA LOGING 1 No. Raw sewage lifting Pumps TeSys M-CB THO/MAG 2.5-4A TeSys AUXILIARY N/O N/C TOP 9A TP Power Contactor 3 NO AUXILIARY CONTACT BLOCK 2NO Power terminals 9 Control terminals 30 Control MCB SP 6A 3 Illuminated Push Button 6 220V AC TRIP Indicating Lamp 3 220V AC Auto/Manual Selector Switch 3

-

-

-

... More
SCH 'A' PART-XIV (SEWAGE DISPOSAL WORKS)

-

-

-

... More
M&L for DWCPE pipes, 150 mm dia, laid in trenches and jointed complete all as specified & directed.

7125

-

-

... More
M&L for DWCPE pipes 200 mm dia, laid in trenches and jointed complete all as specified & directed.

60

-

-

... More
SCH 'A' PART-XV (EXTERNAL WATER SUPPLY WORKS)

-

-

-

... More
Supply, fixing and installation of pumping sets, centrifugal, electric driven, 15 HP, Head-65 mtr, Head range (60-80) Mtr, Discharge-417 LPM, Impeller gun metal material, RPM-2900 inclusive of PCC foundation, complete all as specified and directed.

2

-

-

... More
Supply, fixing and installation of pumping sets, centrifugal, electric driven, 5 HP, Head-27 mtr, Head range (25-35) Mtr, Discharge-300 LPM, Impeller gun metal material, RPM-2900 inclusive of PCC foundation, complete all as specified and directed.

2

-

-

... More
Supply, fixing and installation of pumping sets, centrifugal, electric driven, 1.5 HP, Head-10 mtr, Head range (8-15) Mtr, Discharge-278 LPM, inclusive of PCC foundation, complete all as specified and directed.

2

-

-

... More
Supply, fixing and installation of non clog vertical submersible pumps, 3 HP 200 LPM, Head-25 Mtr with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including guide rail and lifting chain, cables, earthing, testing complete with 2 years maintenance, complete all as specified and directed.

3

-

-

... More
Supply and Fix star delta Starter fully automatic suitable for 15 HP Pumpset 415 V AC complete all as specified and directed.

2

-

-

... More
Supply and Fix direct Online starter suitable for 5 HP Pumpset 415 V AC complete all as specified and directed.

2

-

-

... More
Supply and Fix direct Online starter suitable for 1.5 HP Pumpset 415 V AC complete all as specified and directed.

2

-

-

... More
Supply and Fix direct Online starter suitable for 3 HP non clog vertical Pumpset 415 V AC complete all as specified and directed.

3

-

-

... More
Supply, fixing, connecting and testing of sluice valve Cl body brass spindle, iron wheel head type PN 1.6 (ISI marked) 80 mm dia ends of 80 mm dia GI pipe complete all as specified and directed.

2

-

-

... More
Supply, fixing, connecting and testing of sluice valve Cl body brass spindle, iron wheel head type PN 1.6 (ISI marked) 100 mm dia ends of 100 mm dia GI pipe complete all as specified and directed.

2

-

-

... More
Supply and fixing cast iron air release valves with two air outlets,150 mm dia bore and fixing up in water supply mains complete all as specified and directed.

3

-

-

... More
Supply and fixing heavy duty foot valve of size 50 mm conforming to IS 4038 complete all as specified and directed.

2

-

-

... More
Supply and fixing heavy duty foot valve of size 100 mm conforming to IS 4038 complete all as specified and directed.

2

-

-

... More
M&L for construction of valve pit of size 90 cm X 90 cm X 90 cm (internal dimensions) brick construction including all excavation and earth work in hard/loose soil, returning filling in disposal of surplus spoil to a distance not exceeding 50 m and depositing where directed, PCC in foundation (1:4:8) type D2 (using 40 mm graded crushed aggregate), brick masonry in cement mortar (1:4), rendering 12 mm thick in cement mortar (1:4) internally finished even and fair and pointing flush externally as the work proceeding in the same mortar, mild steel 50X6 mm frame MS sheet cover of 2 mm thick with handle and locking arrangment, painting on all the exposed MS work with two coats of synthetic enamel paint of approved make, painting on all the MS embedded in PCC with two coats of black bituminous paint complete all as specified and directed. NOTE:- The Quoted rate shall include rates for excavation, earthwork, aggregates, brick masonary, PCC, rendering, painting, mild steel, sheet cover, disposal of soil, etc all as directed.

2

-

-

... More
M&L for construction of valve pit of size 50 cm X 50 cm X 50 cm (internal dimensions) brick construction including all excavation and earth work in hard/loose soil, returning filling in disposal of surplus spoil to a distance not exceeding 50 m and depositing where directed, PCC in foundation (1:4:8) type D2 (using 40 mm graded crushed aggregate), brick masonry in cement mortar (1:4), rendering 12 mm thick in cement mortar (1:4) internally finished even and fair and pointing flush externally as the work proceeding in the same mortar, mild steel 50X6 mm frame MS sheet cover of 2 mm thick with handle and locking arrangment, painting on all the exposed MS work with two coats of synthetic enamel paint of approved make, all the MS embedded in PCC with two coats of black bituminous paint complete all as specified and directed. NOTE:- The Quoted rate shall include rates for excavation, earthwork, aggregates, brick masonary, PCC, rendering, painting, mild steel, sheet cover, disposal of soil, etc all as directed.

2

-

-

... More
M & L for Road cutting/digging of size 5.0m x 0.6m x 0.4m, for laying of 150 mm dia GI pipe and filling and making good the disturbed road with PCC Concrete complete all as specified and directed.

3

-

-

... More
M & L for Road cutting/digging 5.0m x 0.4m x 0.3m, for laying of 25/50 mm dia GI pipe and filling and making good the disturbed road with PCC Concrete complete all as specified and directed.

2

-

-

... More
M & L for cutting of GI Pipe 40 mm dia and threading of pipe with suitable size dia, set and fixing of Tee reducer of size 40 mm X 25 mm and fixing of 25 mm dia GI pipe complete all as specified and directed.

1

-

-

... More
SCH 'A' PART-XVI (EXTERNAL ELECTRIC SUPPLY WORKS)

-

-

-

... More
Supply, installing, testing and commissioning of outdoor type, step down transformer, 11KV on HT side and 433 Volts, 3 phase 50 cycle per second, capacity 100 KVA, core type, copper wound, oil immersed, naturally cooled, Oil Natural Air Natural (ONAN) with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN-11 (Vector Group) with neutral brought out on secondary side (LV side) and having tapping at 0, (plus/minus) 2.5%, (plus/minus) 5%, (plus/minus) 7.5% on HV side to be changed by means of hand operated off load tap changer/ gear. Switch handle shall be provided with the locking arrangement alongwith top position indicator. The transformer shall be IS : 1180 (Part-I) : 2014 with maximum total loses as per energy efficiency level 2 of IS : 1180 (Part-I) : 2014 and shall comprise of the following :- (a) Outdoor type HT porcelain bushing with insulator on primary side including all accessories as required. (b) One cable box on LV side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with two Nos cable glands suitable for reception/taking out of XLPE insulated heavy duty armoured cables including glands, joints and jointing materials complete.

1

-

-

... More
(c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill dehydrating agent (silca gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One No 100mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals on tank to facilitate fixing of 02 Nos 32x6mm galvanized iron earth strip for earthing of body and 02 Nos 32x6mm galvanized iron earth strip for earthing of neutral. (j) Rating plate and terminal marking plate. (k) Oil level gauge. (l) Oil drain filter valve. (m) Lifting lugs.

-

-

-

... More
(n) Oil filling hole with cap/plug with connecting plate complete. (o) Air release valve vent with plug. (p) Four plain solid cast steel detachable rollers. (q) First filling of new and unused transformer oil IS-335/93 (Fourth revision) marked filtered and tested upto 50 KV dielectric strength at 2.5mm air gap between testing electrodes. Accessories as per IS-1180 (Part-I) : 2014. (r) Busbar trunking of suitable size at LV side with complete fixing arrangement and incl insulators for connection of multiple outgoing cable at LV side. (s) The transformer shall be installed on a platform/foundation with steps as per manufacturers design and cost of the same shall be deemed to be included in quoted rate by the contrator. NOTE:- Certificate of di electric strength of transformer oil shall be submitted by contractor to GE.

-

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate not less 1.5 mtr below normal ground level, filled around with 15 cm thick alternate layers of charcoal dust and common salt and connected with and including up to 7.5 RM to galvanised iron strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main panel and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC (1:3:6) type C-I in chambers, RCC 1:2:4 type B-I in pit cover reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary excavation & earth work as directed complete all as shown in electric plate No-3 of MES SSR Part I of 2009. PCC chamber shall be constructed at least 1.5 mtr away form the earth electrode and pipe for watering complete all as per specified and directed . Note: The quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth wire and protection pipe and watering pipe. Any variation in length shall be adjusted through deviation order.

12

-

-

... More
Material and labour earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate not less 1.5 mtr below normal ground level , filled around with 15 cm thick alternate layers of charcoal dust and common salt and connected with and including up to 7.5 RM to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and thimble and other ends of the earth strip connected to main panel and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC (1:3:6) type C-I in chambers, RCC 1:2:4 type B-I in pit cover reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary excavation & earth work as directed complete all as shown in electric plate No-3 of MES SSR Part I of 2009. PCC chamber shall be constructed at least 1.5 mtr away form the earth electrode and pipe for watering complete all as per specified and directed. (Internal Electric supply = 1, External electric supply = 4) Note: The quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth wire and protection pipe and watering pipe. Any variation in length shall be adjusted through deviation order.

5

-

-

... More
Supply and fixing Aerial Bunched (AB) cable (on Steel Tubular Poles/ other structures), ISI marked, HT 11000 V Grade, of size 3 core x 95 sq mm with three power cores sections stranded compacted circular aluminimum conductor screened with natural coloured XLPE insulation screened with black extured semi conductor compound and one layer of copper tape and covered with black exturuded PVC (core indentification by colour type marking red, yellow and blue with colour tape placed longitudinally under the copper type) and one bare messenger GI wire of 70 sq mm shall be stranded non compected circular alu alloy complete all as per specified and directed. Note - The following fittings and accessories shall be used to install erect and join the AB cable:- (a) Suspension clamp with eye hook. (b) Suspension fittings and corresponding eye hook. (c) Dead eye fittings. (d) Nylon Cable Ties (e) All Necessary Connectors (f) End and mid cable connectors/ jointing kits

230

-

-

... More
Supply and fixing of Steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-64 (11 metres long) including drilling of holes of required size for fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately and making Pole Number with black paint at suitable height complete all specified and directed.

11

-

-

... More
M&L for bracket for fixing of street light fittings bend to shape, made out of 32 mm dia GI pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers and including two coats of aluminum paint over a coat of red oxide primer complete all specified and directed.

6

-

-

... More
M&L for SMC enclosure of 155 x 155 x 100mm (outdoor pole mounted boxes IP 56 with metric knock outs for cable entry) for single row 2 WAY MCB mountable out door pole mounting type including one single pole MCB, 240 Volts, 'C' Curve type, 6 Amps with rupturing capacity 10 KA, having entry from lower side with cable gland for cable of size 10/16 Sq mm 2 core including locking arrangement complete and enclosure to be fitted on pole with clamps nuts, bolts and washers complete all as specified and directed.

6

-

-

... More
Supply, installation, commissioning and testing of switch air break, gang operated with 12 insulator switch tripple pole mechanically operated, mounted on insulators and steel frame with mechanism worked from ground level for current rating 400 Amp operating voltage 11 KV outdoor type vertical mounted type complete with locking arrangment, assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV Fuse (drop out type) of capacity 10 Amps complete with DO fuses with one number operating rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys including flat iron clamp 50mmx6mm, MS channel of suitable size & length for fixing GOD including nut bolt washers complete all as specified and directed.

2

-

-

... More
Supply and fixing of LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm imbedded in PCC (1:2:4) block, type B-2 (using 40 mm graded crushed stone aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 4 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with copper busbar of suitable 400 amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour and complete internal wiring all as specified & directed. Following shall deemed to be included in the cost of panel:- (a) MCCB neutral link 415 volt 50 Hz, AC 250 Amps 35 KA - 01 No (incoming) (b) MCCB neutral link 415 volt 50 Hz, AC 100 Amps 35 KA - 03 Nos (Outgoing) (c) MCCB neutral link 415 volt 50 Hz, AC 63 Amps 35 KA - 01 No (Outgoing) (d) MCB SPN 32 Amps, 16KA - 01 No (outgoing) (e) On load Changover 250 Amps - 01 No (f) Digital voltmeter - 01 No. (g) Digital Ampr meter - 01 No. (h) Indicator lamp - 01 Set Notes:- (a) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (b) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (c) Panel drawing should be approved by Garrison Engineer .

1

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel Engine driven generating set with Governing class G2 incl sound reducing canopy (sound level not more than 75 db at a distance of 1 mtr) 14 guage as per guideline issued by Ministry of Environment & forest notification, & Central pollution control board 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 100 KVA after considering derating factor at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to 40 degree C at Zangli (J&K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa electric starter motor with batteries, turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 100 kVA all as per as per IS: 13364 and up to date amendments with H class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed.

1

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB IV Norms Compliance) developing Min 156 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement . The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine. (d) Alignment and Fuel Tank : Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel : DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer specifications.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- 1. Capacity of alternator at 1600 meters altitute -100 kVA, AC 3 Phase, 415 volts, 50 Hz. and shall be all as recommended by the manufacturer for above sized motor. 2. PCC platform shall be as per maufacturer design. 3. Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. 4. Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute. 5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's engineer and not by any authorised person. 6. DG Set to be tested for 12 Hrs contineously as following: All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes

-

-

-

... More
Schedule 'A' Part-XVII (Manning, Operation and Maintenance of STP, DG Set & SCADA)

-

-

-

... More
Outsourcing of services for manning, operation and maintenance of main Sewage Treatment Plant (STP), DG Set, SCADA system at Zangli Garrison 1st year after completion of Phase-II during defect liability period by deploying 02 Nos experienced qualified skilled operators/ staff per shift (each shift of 08 Hours) in two shift including Sundays and holidays complete inclusive of daily, weekly, monthly and quarterly maintenance including the equipments, after completion/handing over to MES complete all as specified and directed. Note :- Outsourcing staff will change after every 11 months. The quoted rates are deemed to be included of following activities/ work :- (A) : EQUIPMEMENT TO BE MAINTAINTED (i) Inlet chamber/stilling chamber, Screen chamber , Oil and grease/grit chamber. (ii) Equilisation tank (iii) MBBR- 02 Nos (iv) Anoxic Tank (v) Air Blower (vi) Tube shelter (vii) Disinfection tank (viii) Filter feed tank (ix) ACF & MGF (x) Sludge holding tank (xi) treated water tank (xii) Feed pumps and raw water sewage pumps (xiii) interconnecting pipes (xiv) Hypo dosing system alongwith tanks (xv) valves

1460

-

-

... More
(xvi) Electrical system cables/wires and panels (xvii) installed machinary for treated water supply (xviii) Sludge drying Beds (xix) Up keeping and replacement of the any component or sub-components of the Automation System for proper operation of the system. (xx) Reparing/ replacement of all defective Automation components and sub-components of the equipments installed at STP/DG Set/SCADA as per the requirement to ensure proper uninteruppted operation of the system. Cost of repair/replacement shall be borne by the contractor. (xxi) The contractor shall submit a monthly performance / maintenance report for each system to GE. (xxii) Liquidated Damage shall be levied by the Engineer in charge if contractor is unable/fails to deliver the services as directed. (xxii) The minor mechanical /electrical repair/ maintenance / inspection /lubrication of valves , DG sets, STP machinary (xxiii) The condition of the batteries including the level of electrolyte is to be checked regularly and if required the level of electrolyte is to be topped up with distilled water /electrolyte on required basis by the operattor on duty without any additional cost. (xxiv) Operation of flushing tank. (xxv) The Media shall be changed in winter season and the cost of the same to be included in quoted rate by the tenderer.

-

-

-

... More
(B) : (i) Stacking the sludge cakes properly (ii) Cleaning the blockages in any pump/pipe line (iii) Supplying /distributing the treated water regularly as per the directions (iv) Complete cleaning the grits and channels daily (v) During the cleaning , safety equipments will be supplied / arranged by the contractor (vi) Removing the algae/sludge in the tube settler and keeping the surrounding area clean daily and removing vegetations etc failing which recovery of Rs. 1000/- per day shall be made (vii) Mixing of the chemicals as directed. (C) : (i) Duty roster of manpower deployed shall be displayed otherwise recovery of Rs 1000/- per installation per day shall be made (ii) Contractor shall take labour license for provision of labour under contract . All the provisions of contract labour act 1970 and amendment there to and specified in tender shall be strictly adhered to (iii) For payment of minimum wages to the works, provision in tender and particular specifications shall be strictly adhered (iv) Log sheet for records shall be supplied by contractor after approval of format by Engineer in Charge. (v) Diesel and engine oil for DG set shall be provided by GE Office. (vi) Contractor shall ensure that treated water shall be confirmed within the permissible limit. (vii) Proper running record in respect of STP, DG Set and SCADA system to be maintaned by the contractor and produced to Engineer in Charge as and when required. (viii) Contractor will hand over STP plant and installations to the deptt in good woking condition on expiry of contract period. (ix) Contractor shall strictly ensure proper training to MES personal wrt operation and mintenance of STP and SCADA works. The contractor's rates shall be deemed to be included for above aspect. Nothing extra shall be paid on this account.

-

-

-

... More
As per item No. 9.01 - 9.03 above but for 2nd year after completion of Phase-II during defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 3rd year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 4th year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 5th year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 6th year after completion of Phase-II during defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 7th year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 8th year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 9th year after completion of Phase-II after defect liability period

1460

-

-

... More
As per item No. 9.01 - 9.03 above but for 10th year after completion of Phase-II after defect liability period

1460

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.