Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date26 Mar 2025
Closing Soon28 Apr 2025
Tender Amount₹ 12,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(h) Air filter for air conditioner mettalic type, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(r) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(t) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
(u) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
(v) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
(w) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
M&L for Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.

3

-

-

... More
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(c) Hermetic sealed unit, for water cooler capacity 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.

1

-

-

... More
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.

1

-

-

... More
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/150 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.

1

-

-

... More
M&L for Replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Spray painting of water cooler capacity 150/150 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.

4

-

-

... More
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 285 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(e) Hermetic sealed unit, capacity 1/6 HP, suitable for deep freezer of 300 to 405 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(h) Relay, PTC of any type, suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 215 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(n) Evaporator coil for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 215 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(q) Wiring kit for refrigerator, capacity 280 to 340 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
M&L for Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.

3

-

-

... More
S&F ofSheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.

2

-

-

... More
M&L for Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 to 5.0 capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.

4

-

-

... More
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.

3

-

-

... More
(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.

1

-

-

... More
M&L for Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.

1

-

-

... More
M&L for Rewinding of main transformer of voltage stabilizer capacity 3.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.

1

-

-

... More
M&L for Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.

1

-

-

... More
M&L for Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. (Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate).

15

-

-

... More
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
(b) Selector switch for controlling of motor speed, 240 volts, 50Hz, three steps, complete all as specified and as directed by Engineer-In-Charge.

15

-

-

... More
(c) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.

15

-

-

... More
(d) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.

15

-

-

... More
(e) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.

15

-

-

... More
(f) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.

10

-

-

... More
(g) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.

10

-

-

... More
M&L for Replacement of old unserviceable ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
M&L for Replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.

5

-

-

... More
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.

3

-

-

... More
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 10.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge.(Note: Two runs of 10.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit).

20

-

-

... More
M&L for Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.

20

-

-

... More
Replacement of old unserviceable/ damaged MCCB with new MCCB, three pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
S&F Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.

4

-

-

... More
S&F MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Supplying and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and as directed by Engineer-In-Charge.

30

-

-

... More
M&L for PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.

30

-

-

... More
M&L for PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.

30

-

-

... More
S&F in repair Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for replacement of Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. (Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces).

1

-

-

... More
M&L for Replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
M&L for Replacement of old unserviceable/ damaged plug top with new plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 4 sqmm all as specified and directed.

20

-

-

... More
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 6 sqmm all as specified and directed.

20

-

-

... More
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 10 sqmm all as specified and directed.

20

-

-

... More
Material and labour for replacement of PVC insulated flat twin core aluminium stranded cable of size 16 sqmm all as specified and directed.

20

-

-

... More
Supply and fixing in replacement with new LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old UNSV security lights all as specified and directed.

30

-

-

... More
Supply and fixing in replacement with new LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old UNSV security lights all as specified and directed.

20

-

-

... More
Supply and fixing in replacement with new LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down old UNSV security lights all as specified and directed.

15

-

-

... More
Supply and fixing in replacement with new LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old UNSV security lights all as specified and directed.

10

-

-

... More
Supply and fixing in replacement with new LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old UNSV security lights all as specified and directed.

9

-

-

... More
Supply and fixing in replacement with new LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old UNSV security lights all as specified and directed.

7

-

-

... More
M&L for Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.

83.6

-

-

... More
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.

48.8

-

-

... More
M&L for Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.

34.7

-

-

... More
M&L for Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.

15.62

-

-

... More
M&L for Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.

25.6

-

-

... More
Supplying, laying or fixing in repair or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 16 sqmm 4 core.

330

-

-

... More
Description all as per item No 119.00 here-in-before but of size 25 sqmm 4 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
Description all as per item No 119.00 here-in-before but of size 50 sqmm 3.5 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge.

55

-

-

... More
M&L for Carrying out periodic maintenance of DG set capacity 62.5 KVA Make : 'Cummins' by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Pallanwala complete all as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items.

1

-

-

... More
Supply only following new spare parts required for repair of DG Set capacity 62.5 KVA :-

-

-

-

... More
Piston with piston pin, connecting rod and lock assembly complete.

2

-

-

... More
Cylinder liner with liner ring assembly complete.

2

-

-

... More
Piston ring set.

2

-

-

... More
Main Bearing.

2

-

-

... More
Connecting rod bearing of 6-pairs.

2

-

-

... More
Small end bearing

2

-

-

... More
Major overhauling gasket set with 'O' ring set.

2

-

-

... More
Head valve inlet and exhaust.

2

-

-

... More
Main Oil seal (Front and Rear).

2

-

-

... More
Hose pipe with clips and joint set.

1

-

-

... More
Fuel Filter.

2

-

-

... More
Oil Filter.

1

-

-

... More
Air cleaner filter

1

-

-

... More
V-Belts

3

-

-

... More
Supply and fix in replacement of old U/S set of 4 nos high pressure copper tubes of required size from FIP to injectors for DG set 62.5 KVA

1

-

-

... More
Replacement of old damaged/ unserviceable Engine temperature gauge with new Engine temperature gauge suitable for DG set of capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 62.5 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Replacement of old unserviceable/ damaged battery with new storage cell lead acid type 12 Volts, 150 AH including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Supply only copper lead cable 2 mtrs long, multi-stranded, with copper thimble for making necessary connections at both ends, suitable for 12 Volts including copper nuts, bolts and washers, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
De-assembling of radiator for cleaning and repair, using ‘K’ oil and radiator cleaning solution hydro-chloric acid by pressure of pump/ caustic soda with wire brush and necessary welding/ brazing of water tubes/ fins, whichever is required for cleaning and repairing, complete all as specified and as directed for 30 to 62.5 KVA DG Set.

2

-

-

... More
Overhauling Fuel Injection Pump by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification all as directed for 62.5 KVA DG Set.

1

-

-

... More
Supply and filling engine oil SAE 20W40 Make : Sawita/Valvoline

40

-

-

... More
Supply and filling radiator coolant Make : Volvoline

20

-

-

... More
Supply and fix in replacement of self starter assembly 12 volt suitable for 62.5 KVA DG set

1

-

-

... More
M&L for Disconnecting electric connections from alternator, capacity 62.5 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note: (a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush with new carbon bush suitable for alternator of DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush holder with new carbon bush holder suitable for alternator of DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
M&L for Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable slip ring assembly with new slip ring assembly suitable for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable solenoid switch with new solenoid switch suitable for self starter capacity 12 Volts, for DG set capacity 62.5 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Carryout periodic maintenance of DG set capacity 30 KVA Make : 'Mahindra' by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Pallanwala complete all as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items.

2

-

-

... More
Supply only following new spare parts required for repair of DG Set capacity 30 KVA :-

-

-

-

... More
Piston with piston pin, connecting rod and lock assembly complete.

2

-

-

... More
Cylinder liner with liner ring assembly complete.

2

-

-

... More
Piston ring set.

2

-

-

... More
Main Bearing.

2

-

-

... More
Connecting rod bearing of 4-pairs.

4

-

-

... More
Small end bearing

2

-

-

... More
Major overhauling gasket set with 'O' ring set.

2

-

-

... More
Head valve inlet and exhaust.

2

-

-

... More
Main Oil seal (Front and Rear).

4

-

-

... More
Hose pipe with clips and joint set.

2

-

-

... More
Fuel Filter.

4

-

-

... More
Oil Filter.

2

-

-

... More
Air cleaner filter

2

-

-

... More
V-Belts

4

-

-

... More
Supply and fix in replacement of old U/S set of 4 nos high pressure copper tubes of required size from FIP to injectors for DG set 30 KVA

2

-

-

... More
Replacement of old damaged/ unserviceable Engine temperature gauge with new Engine temperature gauge suitable for DG set of capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 30 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
M&L for Overhauling Fuel Injection Pump by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification all as directed for 30 KVA DG Set.

2

-

-

... More
Supply and fix in replacement of self starter assembly 12 volt suitable for 30 KVA DG set.

2

-

-

... More
M&L for Disconnecting electric connections from alternator, capacity 30 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note:(a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates.

2

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush with new carbon bush suitable for alternator of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

16

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush holder with new carbon bush holder suitable for alternator of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

16

-

-

... More
M&L for Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Replacement of old damaged/ unserviceable slip ring assembly with new slip ring assembly suitable for DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Replacement of old damaged/ unserviceable solenoid switch with new solenoid switch suitable for self starter capacity 12 Volts, of DG set capacity 30 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Replacement of old unserviceable/ damaged Change over switch with new Change over switch, on load, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, with center handle, conforms to IS:13947 (Part-3); IEC:60947-2, with stain less steel enclouser complete all as specified and as directed by Engineer-In-Charge. Make: Indo-Asian cat part No- ICAS0200 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens.

2

-

-

... More
M&L for Carrying out periodic maintenance of DG set capacity 40 KVA Make : 'Greaves' by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Pallanwala complete all as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items.

1

-

-

... More
Supply only following new spare parts required for repair of DG Set capacity 30 KVA :-

-

-

-

... More
Piston with piston pin, connecting rod and lock assembly complete.

2

-

-

... More
Cylinder liner with liner ring assembly complete.

2

-

-

... More
Piston ring set.

2

-

-

... More
Main Bearing.

4

-

-

... More
Connecting rod bearing of 4-pairs.

4

-

-

... More
Small end bearing

4

-

-

... More
Major overhauling gasket set with 'O' ring set.

4

-

-

... More
Head valve inlet and exhaust.

4

-

-

... More
Main Oil seal (Front and Rear).

4

-

-

... More
Hose pipe with clips and joint set.

2

-

-

... More
Fuel Filter.

4

-

-

... More
Oil Filter.

2

-

-

... More
Air cleaner filter

2

-

-

... More
V-Belts

2

-

-

... More
4 nos high pressure copper tubes of required size from FIP to injectors

4

-

-

... More
M&L for Repair to Cam shaft assembly of diesel engine capacity suitable for 40 KVA DG set, by metal filling, cutting, grinding, polishing as required size including required material, tools and plant, complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
M&L for Repair to Crank shaft assembly of diesel engine capacity suitable for 40 KVA DG set, by metal filling, cutting, grinding, polishing as required size including required material, tools and plant, complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable Engine temperature gauge with new Engine temperature gauge suitable for DG set of capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 40 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Disconnecting electric connections from alternator, capacity 40 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note:(a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush with new carbon bush suitable for alternator of DG set capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush holder with new carbon bush holder suitable for alternator of DG set capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable slip ring assembly with new slip ring assembly suitable for DG set capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Replacement of old damaged/ unserviceable solenoid switch with new solenoid switch suitable for self starter capacity 12 Volts, of DG set capacity 40 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Carrying out periodic maintenance of DG set capacity 25 KVA Make : 'Greaves' by calibration of fuel injection pump including dismantling of radiator, radiator fan, water pump assembly, air cleaner, rocker cover housing rocker, oiling and greasing to movable spare parts such as bearing etc, replacement of old defective air filter, fuel filter, oil filter, insulation cover/ asbestos rope of exhaust pipe with new and manufacturer specified air filter, fuel filter and oil filter, insulation cover/ asbestos rope of exhaust pipe tightening the screws of hose and hose pipe set, strip opening of alternator cleaning of stator and field coils, rotor assembly, and apply one coat of varnishing using ‘H’ class varnish and complete service work as required at site, re-assembling the engine/ alternator in existing position, and testing on completion installed at Pump House Kachriyal complete all as directed by Engineer-In-Charge. Note: New spare parts will be measured and paid separately as supply only under the respective items.

1

-

-

... More
Supply only following new spare parts required for repair of DG Set capacity 30 KVA :-

-

-

-

... More
Piston with piston pin, connecting rod and lock assembly complete.

2

-

-

... More
Cylinder liner with liner ring assembly complete.

4

-

-

... More
Piston ring set.

4

-

-

... More
Main Bearing.

4

-

-

... More
Connecting rod bearing of 4-pairs.

8

-

-

... More
Small end bearing

8

-

-

... More
Major overhauling gasket set with 'O' ring set.

4

-

-

... More
Head valve inlet and exhaust.

2

-

-

... More
Main Oil seal (Front and Rear).

2

-

-

... More
Hose pipe with clips and joint set.

4

-

-

... More
Fuel Filter.

2

-

-

... More
Oil Filter.

1

-

-

... More
Air cleaner filter

1

-

-

... More
V-Belts

3

-

-

... More
4 nos high pressure copper tubes of required size from FIP to injectors

4

-

-

... More
M&L for Calibration, repair, checking of fuel injector nozzle assembly of DG set capacity 25 KVA, transport to workshop including replacement of injector nozzle cap, barrel and small spares required for smooth functioning of injector nozzle, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
M&L for Disconnecting electric connections from alternator, capacity 25 KVA, decoupling of engine and alternator, separaing from base plate, and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading, by mechenical means, replacing defective spare parts with new spare parts, including any type of machine work required at site/ workshop to compete the repair including complete servicing all as required at site, re-assembling in existing position complete and testing on completion all as specified and as directed by Engineer-In-Charge Note:(a) New spare parts will be measured and paid separately as supply only under the respective items. (b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling of alternator will deemed to be included in quoted rates.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush with new carbon bush suitable for alternator of DG set capacity 25 KVA, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Replacement of old damaged/ unserviceable carbon bush holder with new carbon bush holder suitable for alternator of DG set capacity 25 KVA, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
M&L for Replacement of old damaged/ unserviceable electronic rectifier/ Automatic Voltage Rectifier with new electronic rectifier/ Automatic Voltage Rectifier suitable for DG set capacity 25 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L for Replacement of old damaged/ unserviceable slip ring assembly with new slip ring assembly suitable for DG set capacity 25 KVA, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Replacement of old damaged/ unserviceable solenoid switch with new solenoid switch suitable for self starter capacity 12 Volts, of DG set capacity 25 KVA, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Supply and fix in replacement of DOL starter suitable for submersible pump set of capacity 7.5 HP, complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M&L for Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.

5

-

-

... More
Amount of Schedule of credit of for Rs 90,058.00 shall be deducted from quoted amount.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.