Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Security and Emergency Services
Eprocure
Opening Date29 Nov 2024
Closing Date19 Jan 2025
Tender Amount₹ 7,69,27,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Total amount of Sch 'A' PART-IV ( Road/Path/Culvert Works)

1

2359457

-

... More
Total amount of Sch 'A' PART-V (Sewage Disposal Works)

1

600713

-

... More
Total amount of Sch 'A' PART-VI (Area Drainage Works)

1

1260450

-

... More
Total amount of Sch 'A' PART-VII ( Section-I)(Security wall, fencing & gate Works)

1

51403013

-

... More
Sch 'A' PART-VII ( Section-II) ( Security wall, fencing & gate Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.

-

-

-

... More
Taking down old concertina coil of any dia from existing old fencing complete all as specified and directed.

1200

-

-

... More
Taking down old barbed wire any dia from existing old fencing. complete all as specified and directed.

96

-

-

... More
S&F,concertina coil fencing with punch tape concertina coil 450mm dia, strached to 6.0 meter length, having 50 nos sprial turns per 6.0 meter length, spring core wire (2.59mm thick) of high rensile strength of 1620 N/sqm with tape (0.52mm thick) hot dip galvanised upto 20 micros and weight of each coil 7.5 to 8.0 Kg and fixing the same on Y shaped angle iron 8 horizontal R.B.T ( Reinforced barbed tape ) stud tied with GI staple sand GI clips to retain horizontal clips shall be @5 Nos per 2 sprial turns approximate 125 clips per coil including necessary bolts cinokete aklk as specified and as directed. Note: for measurement purpose overall lenght of the wire shall be measured) the get approved by GE before procurment.

1132.5

-

-

... More
Total amount of Schedule 'A' PART-VII ( Section-II) ( Security wall, fencing & gate Works)

-

-

-

... More
Total amount of Sch 'A' PART-VIII (SECTION-I) ( INTERNAL ELECTRIC SUPPLY WORKS)

1

221610

-

... More
Sch 'A' PART-VIII ( Section-II) ( INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.

-

-

-

... More
S & F modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

88

-

-

... More
S & F modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

40

-

-

... More
S & F modular type 2/3 pin combined shuttered type 6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

16

-

-

... More
S & F modular type 2/3 pin combined shuttered type 16 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.

16

-

-

... More
S & F modular type 20 A 1P MCB with socket, conforming to IS 60898- 1: 2002 complete all as specified in IS732: 2019 and directed by the engineer-in-charge.

4

-

-

... More
S & F 16 A,230 V , 50 Hz, 4 P MCB 'C ' curve conforming to IS/IEC 60898-1-2002, having breaking capacity lcn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the Engineer-in-Charge.

4

-

-

... More
S & F 20 W surface/ wall mounted LED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of 90lumen/W, CRI 80, PF 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the Engineer-in-Charge.

48

-

-

... More
S & F 35 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance. suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge.

16

-

-

... More
S & F 200W LED Flood light with aluminium pressure die cast housing , high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, & luminaire lumen 2500Im and system efficiency 100Im/W, in built electronic driver prewired upto terminal block with driver efficiency 85% power factor 0.95, suitable for external pole upto 35mm, LED Make:- Nichia/ Cree/Osram, CRl70, ambient temperature range 0-450C, THD10%, colour temperature 5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria,multistage constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level 60V DC as per IEC Standard including GI pipe medium grade ISi mark of size 32mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamps as required to fix to wall all as specified and directed.

8

-

-

... More
Total amount of Sch 'A' PART-VIII (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)

-

-

-

... More
Total amount of Sch 'A' PART-IX (SECTION-I) (Lightening Protection Works)

1

554123

-

... More
SCHEDULE `A' PART-IX (SECTION-II) (Lightening Protection Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.

-

-

-

... More
Supply and fixing PVC earthing strip DMC insulator for, electrical installation surface tretment colour coated, tensile strength 25 Mpa including washer Nut & bolts etc complete all as specified and as directed

30

-

-

... More
Total amount of Sch 'A' PART-IX (SECTION-II) (Lightening Protection Works)

-

-

-

... More
Total amount of Sch 'A' PART-X (EXTERNAL WATER SUPPLY WORKS)

1

257879

-

... More
Total amount of Sch 'A' PART-XI (Section-I) (External Electric supply)

1

2114052

-

... More
SCHEDULE `A' PART-XI (SECTION-II) (External Electric supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.

-

-

-

... More
Supply, installation, testing and commissioning of LT Feeder Pillar outdoor type confirming of IS 5039, CPRI approval, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer sheet shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front. Panel shall be provided with proper ventilation arrangement from both sides including ventilation fan etc. Protection of enclosure IP 56 with pre-treatment through 7 tank hot chemical process prior to powder coated powder coated with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron with pure polyester siemens grey structural RAL 7035 shade. The bottom of outer shell contains a detachable plate having provision for armoured cable entry with adequate size detachable glands. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. The panel shall be provided with manufacturer name plate, heavy duty SS cable glands of adequate size for incoming and outgoing cables. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs 40 cm grouted in PCC 1:2:4 and making good disturbed surface complete and comprising of the following:

1

-

-

... More
(A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustible, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar. The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables. All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied, ferruled for proper identification and crimped with adequate size of lugs. (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete (iii) Indication lamps LED type--(RYB) =01 set of three B. INCOMER (i) MCCB 200 Amp 4 pole confirming to IS:13947(Part-3) 1993, 25 KA, lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 In setting complete with phase separator - 01 nos (ii) ON Load change over switch without enclosure 200 amps 4 pole TPN front handle operated confirming to IS:13947(Part-3) 1993 -01 nos

-

-

-

... More
C. OUTGOING (i) MCCB 63 Amp 4 pole confirming to IS:13947( ) 1993, 16 KA, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overloaa80-f00% of nominal current and adjustable short ckt 5 to 10 In setting complete with phase seperator - 04 nos ( 03 working +01 Spare )(ii) MCB TPN 40 Amp 4 pole confirming to IS:13947(Part-3) 1993, 10 KA - 02 nos (iii) Street light timer 63 Amp three phase complete -02 Nos. D..Platform for feeder pillar/LT Panel shall be of suitable size as directed 200mm height above ground level, the foundation shall be using PCC 1:2:4 type B1,15cm thick, brick (sub class B) work in CM 1:6, rendering in CM 1:6 on exposed surfaces and 100mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel. Note: (i)_LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel (iii) Contractor shall submit drawing for approval prior to place order.(ii) The quoted rate shall includes rate shall includes minor items such as lugs, nuts & bolts, washer, top insulators, sleeves, provision of extra holes in bus bar etc. ii) All internal wiring shall be done with PVC insulated solid copper conductor FRLS cable confirming to IS-694.(iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank - portion between panel and wall shall be filled with PCC 1:2:4 incl masonry work leaving ducts for cables complete all as directed.

-

-

-

... More
Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISi Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like sockets, coupler, 'O' Ring etc, for protection of cable including hanging on wall with GI clamps nuts, bolts complete all as specified and directed.

2600

-

-

... More
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc for any size complete as directed by Engineer-in-Charge.

800

-

-

... More
S&F LED Street Light fitting 60 watt, for opearting voltage between 140V to 300V system efficiency not less than 120 lumen/ watt.PF- 0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high/ low voltage cut off, maintenance free isolated Electronic driver with over voltage protection.surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing(heat sink) with UV stabilized optics, polycarbonate LENS for symmetrical light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and as directed by Engr-in- Charge

140

-

-

... More
Supply and laying cable junction boxes with terminals IP 66 Halogen free and weather proof of outdoor installation ( with metric knockouts for cable entry- Black Colour) Cable Size 16/25 Sqmm, Box Dimensions-200 x160 x 98, Catalog No-KF 9255(hensel) complete taking out of loop of cable from ground by necessary earth work al specified and directed by Engr in Charge.

74

-

-

... More
M&L for fixing new street light bracket made out of GI pipe medium grade 40 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting, welding ,drilling holes, nut, bolts, washers fittings etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.

148

-

-

... More
S & F cable route indicator made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded letter HT CABLE or LT CABLE suitably inscribed on Cl circular plate 8 mm thick 100 dia complete incl necessary PCC 1:3:6, type C-2 using 40 mm graded aggregate) block of suitable size and necessary earth work and excavation all as specified and directed.

130

-

-

... More
Supply , install , testing and commission outdoor type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thick MS sheet and MS angle secllon 50x50X6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back open able double door system complete suitable for 3 phase 4 wire 415 Volts, 50 Hz, size of panel board- 1.0x0.9x0.5 Mtr,(a) TPN aluminium bus bar 200 Amps insulated with colour corded heat shrinkable sleeve.(b) Incoming MCCB 4 pole 63 Amp 25 KA - 01 Nos (c) Out going MCB TP 63 Amps 10 KA- 02 Nos (d) Indicator lamps RYB - 01 Set (e) Voltmeter 0-500 volts 96 mm square flush pattern-01 No. Make-AE (f) Amp mete 0-200 Amps 96mm square flush pattern - 01 Nos Note:- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulator, sleeves, provision of extra holes in bus bar etc. (ii) aII internal wiring shall be done with suitable size.of PVC insulated solid copper conductor FRLS cable conforming to IS -694 (iii)Panel drawing shall be got approved before placing of order from Engr-in-Charge/ GE (iv The panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonry work leaving ducts for cables complete all as directed. (vii) All MCCB confirming to IS:13947(Part-3) 1993, lcs =100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% of nominal current and adjustable short ckt 5 to 10 in setting complete with phase seperator.

2

-

-

... More
Total amount of Sch 'A' PART-XI(SECTION-II) (External Electric supply)

-

-

-

... More
Total amount of Sch 'A' PART-XII (SITE CLEARANCE, EXCAVATION AND EARTH WORKS )

1

5029417

-

... More
NOTE: Amount against schedule of credit of Rs. 47550.00 for retrieved materials mentioned under relevant part XIII of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during acceptance of tender.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.