Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date30 Sep 2024
Tender Amount₹ 39,38,584.8 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling stay assembly complete with stay wire complete all as specified and directed.

2

-

-

... More
Dismantling GI earth wire/ old unserviceable guarding complete all as specified and directed.

0.5

-

-

... More
Dismantling street light fitting of any size and type complete all as specified and directed.

10

-

-

... More
Dismantling cable protection pipe of size 25/40/50/80 mm dia complete all as specified and directed.

36

-

-

... More
Taking out old unserviceable service mains complete all as specified and directed.

700

-

-

... More
Taking out old unserviceable/ broken street light bracket complete all as specified and directed.

10

-

-

... More
Taking out old unserviceable PCC/steel pole complete all as specified and directed.

15

-

-

... More
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 10 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.

1200

-

-

... More
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 16 Sqmm 2 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.

200

-

-

... More
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 25 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed.

300

-

-

... More
Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade, cross section area 50 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. Note for srl item No 11 to 14:- (a) Earth work shall be measured and paid separately.

320

-

-

... More
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, laying of cables/pipes/poles etc., and getting out in soft/loose soil complete all as specified and directed.

436.32

-

-

... More
All as per item No 17 above but Exc 1.50 and n.exc 3.0m deep complete all as specified and directed

1.62

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding of 25 cm thick in soft/loose soil complete all as specified and directed

279.78

-

-

... More
Removal of surplus soil as obtained from excavation to a distance not exc. 50 Mtr and depositing where directed at a level not exc. 1.5 Mtr above the starting point complete all as specified and directed.

156.54

-

-

... More
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-charge. Note:-Punned thickness only shall be measured and paid.

130.9

-

-

... More
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.

12.93

-

-

... More
Supply and fixing steel tubes, light grade, galvanised 40 mm dia with all fittings laid in trenches complete all as specified and directed.

18

-

-

... More
Supply and fixing steel tubes, light grade, galvanised 50 mm dia with all fittings laid in trenches complete all as specified and directed.

18

-

-

... More
Supply and fixing street light Engineering plastic one piece moulding control box with locking arrangement made out of HDPE and FI clamp 25 x 3mm complete of dimensions in CM +/-10%(34x28x13) including MCB SP 6 Amp 240 Volts complete with 02 Nos aluminium busbar or terminal two Nos (2P-R/Y/B and N) of rating 63 amps for single phase and neutral on porcelain based insulators complete all as specified and directed.

25

-

-

... More
Supply, erecting and fixing the true vertical position, steel tubular swaged pole(410 SP-31),09 mtr long, complete with cast iron base plate, pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole ,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.(Numbering of the poles shall be done with synthetic enamelled painted letter of shape & size as directed. Note:-(a) Cost of numbering of pole shall be deemed to included in unit rate.(b) Excavation, Earth work and PCC foundation will be measured and paid for separately.

15

-

-

... More
S & F GI bracket made out of GI pipe light grade of size 50/40/32 mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed.

25

-

-

... More
Supply and fixing LED street light luminaries 70/72 Watt having shall be made of single piece Aluminium Die cast with powder coated in RAL-7032 shade with heat distribution fins on housing with UV stabilized toughened glass cover and should have secondary lens on each LED for better light distribution .The system luminaire efficacy should be 110 LM/W with high power LED,.LED driver shall be potted and BIS certified with efficiency 85 % frequency 50 HZ, Operating voltage range 120V-270V,current not more than 0.320 Amp, PF 0.95, THD (I) 10 %, supported with 5 KV internal and 10 KV external SPD, Humidity 10% to 90 % RH, working temperature - 20⁰ C to 50⁰ C lige expectancy of LED should be 50000 burning hours with minimum 70 % initial lumen maintained, CRI 70

25

-

-

... More
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts as specified including necessary form work complete all as specified & directed.

0.76

-

-

... More
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly etc including necessary form work complete all as specified & directed.

7.65

-

-

... More
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement complete all as specified & directed.

1.53

-

-

... More
Supply and fixing 1100 volts grade heavy duty cable with PVC insulated solid/stranded copper conductor served with an inner sheathing of PVC tape and overall PVC sheathed of size 1.5 sqmm 3 core suitable for LED security light for pole box to street light fitting with connector and thimble, nut & bolt and washer etc., complete all as specified and directed.

200

-

-

... More
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel/Bus Bar, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium busbar of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back side opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following:-

4

-

-

... More
(a) Aluminium bus bar cap 200 Amp-04 Nos

-

-

-

... More
(b) MCCB four with breaking capacity 25 or 35 KA,40 Amp - 01 No

-

-

-

... More
(c) Digital Voltmeter-96 x 96 mm flush secure Panel mounting type 0-500V with selector switch - 01 No

-

-

-

... More
(d) Digital Amp meter 96 mm X 96 mm flush secure Panel mounting type 0-100 Amps with selector switch with CT - 01 No

-

-

-

... More
(e) RYB neon indicating lamp set of three- 01

-

-

-

... More
Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 40mmx40mmx6mm and 60 cm in height for fixing the panel (ii) Danger Notice board in Hindi and English of size 20cmx 15cm shall be fixed on the panel (iii) Contractor provided powder coated finish paint on panel and test certificate.

-

-

-

... More
M & L for Earthing complete with and including galvanised steel earth plate electrode 60×60cm×6mm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia (No 8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board or junction box all as shown in electrical plate No. 3 of SSR 2009 (Pt-I) & including necessary excavation and earth work complete all as specified and directed. Note :- The rate also include charcoal and salt in alternate layers, 20mm bore GI Pipe (light grade) for watering, protection pipe funnel, wire mesh, PCC 1:2:4 type B1 chamber in cement concrete 50mm thick precast RCC cover duly reinforced with XPM (weight not less than 3kg/sqm) and CI frame etc and including provision of test point, connecting to test point and testing on completion etc complete.

2

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode of size 60×60cm×6mm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to equipment by using GI strips of size 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No.5 of MES schedule and connected to earthing test point all as specified and directed including earth pit of size 30cm x 30cm x 45 cm made of PCC 1:3:6 and PCC 1:2:4 cover, funnel, GI Tubing etc & testing on completion. Note :- The unit rate includes the cost of excavation & earth work in any type of soil, charcoal and salt in alternate layers, 20mm bore GI Pipe (med grade) for watering 40mm GI protection pipe (light grade) funnel, wire mesh, lugs, PCC 1:2:4 type B1 chamber in cement concrete 50mm thick precast RCC M-25 (design mix) cover duly reinforced with XPM (weight not less than 3kg/sqm) and CI frame etc and including provision of test point, connecting to test point and testing on completion etc complete all as specified. The unit rate also include earthing lead and protection pipe upto 7.5mtr from top of earth plate.

12

-

-

... More
Supply and fixing of on load changeover switch 415 volt in sheet metal enclosure 4 pole of capacity 100,160& 250 Amp (as required) complete all as specified and directed.

1

-

-

... More
M&L for Painting to LT poles, 9 mtr with cross arms, bracing and clamps with one coat of synthetic enamel paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30 cm height all as specified and directed.

30

-

-

... More
Supply, fabricate , fixing structural mild steel RS joist , channel angle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section including nuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed , inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed.

1

-

-

... More
M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified and directed.

12

-

-

... More
M&L in replacement of Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100-volt grade all as specified.

60

-

-

... More
M&L in replacement of ACSR conductor of any size and any type including stretching, fixing and binding to insulator on OH LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified. This item includes all consumables (such as binding wire and replacement insulators and cross arms, etc., for replacement of damaged ones found after/ during replacement process).

12

-

-

... More
Re stretching of LT /HT ACSR conductor and GI wire of any size and on any type of poles carrying upto six conductors in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles complete all as specified and directed.

10

-

-

... More
M & L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and as directed.

2

-

-

... More
M & L for hot dip galvanized stay strands of grade I, 7 Nos wires construction, wire diameter 4 mm, nominal strand diameter 12 mm, heavy zinc coating complete all as specified and as directed.

0.3

-

-

... More
S & F galvanised mild steel wire 3.15 mm or 4 mm dia in overhead lines complete all as specified and as directed.

0.5

-

-

... More
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), LT Panel/Bus Bar, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium busbar of Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) lock with 2 keys, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size including the provision of space to accommodate the under mentioned items. The scope of work includes the following: -

2

-

-

... More
(a) Aluminium bus bar cap 200 Amp-04 Nos

-

-

-

... More
(b) MCCB four pole with breaking capacity 25 or 35 KA,63 Amp - 01 No

-

-

-

... More
(c) Digital Voltmeter-96 x 96 mm flush secure Panel mounting type 0-500V with selector switch - 01 No

-

-

-

... More
(d) Digital Amp meter 96 mm X 96 mm flush secure Panel mounting type 0-100 Amps with selector switch with CT - 01 No

-

-

-

... More
(e) RYB neon indicating lamp set of three- 01

-

-

-

... More
Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 40mmx40mmx6mm and 60 cm in height for fixing the panel (iii) Danger Notice board in Hindi and English of size 20cmx 15cm shall be fixed on the panel (vi) Contractor provided powder coated finish paint on panel and test certificate.

-

-

-

... More
Supply and installation of 7.5 KVA 1 Phase Silent DG Set comprising of (CPCB IV+ NORMS COMPLIANCE developing 10.74 BHP @ 1500 RPM 7.5 KVA Alternator rated at 1 phase, 230 Volts , 50 Hz: 0.8 p.f @ 1500 RPM both mounted , and aligned on a common MS base frame complete with MS Fuel Tank, Manual Control Panel Residential Exhaust Silencer ,AVM pads fitted on base frame ,1 No. 12 Volts DC Battery, Battery Leads, 1st Fill of Lube Oil all housed in Sound proof Acoustic Enclosure.

2

-

-

... More
Supply and installation of 5.5 KVA Ultra Silent Recoil plus Self generator can save the day. 5500VA Portable Inverter Generator is a very good option on can consider. This product is easy to use and can be moved around easily. This product works at a frequency of 50 Hz, with very less immersion. Generators does not create any noise and works very smoothly. It has a voltage of 230 V. May it be regular electronic appliances of heave bulky machinery, the generator can run it all. It can easily work for straight 6 to 7 hours. Engine type of this generator is GCAGD

3

-

-

... More
Note :- The rate of Generator quoted by contractor shall be as per following specification with one year service /replace warranty

-

-

-

... More
Type : Ultra Silent & Compact

-

-

-

... More
Engine Type :GCAGD

-

-

-

... More
Starting System :Recoil/ Electric Starter

-

-

-

... More
Fuel : Petrol

-

-

-

... More
Rated Output Power :5.5 kva

-

-

-

... More
Max output :7.0

-

-

-

... More
Displacement :389 cm³

-

-

-

... More
Continuous Running Hours :6.5 hrs.

-

-

-

... More
ignition system :Full Transistor Ignition

-

-

-

... More
Noise Level :85.2 DB

-

-

-

... More
Voltage :230V

-

-

-

... More
Note Specification should be of following

-

-

-

... More
Fuel System :Electronically Controlled Fuel Injection system

-

-

-

... More
Oil Alert System :Yes

-

-

-

... More
Fuel Tank 19.2 Liters

-

-

-

... More
Oil capacity: 1.1liter

-

-

-

... More
Fuel consumption : 1200ml/ hr

-

-

-

... More
Frequency :50 HZ

-

-

-

... More
Rated Current :23.9 A

-

-

-

... More
Dimensions :1261x700x722 mm

-

-

-

... More
Weight : 123.2 Kg

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.