Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Apr 2025
Closing Soon23 May 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour in replacement sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.

100

-

-

... More
Description all as per Ser item No 6.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.

120

-

-

... More
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud TPN 6 way 415 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.

6

-

-

... More
Supply and fixing ceiling rose 3 terminal surface type complete all as specified and as directed.

250

-

-

... More
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.

10

-

-

... More
Supply and fixing switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and as directed.

210

-

-

... More
Supply and fixing bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
Supply and fixing PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 15 amp 240 volts complete all as specified and as directed.

35

-

-

... More
Description all as per Ser item No 12.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.

190

-

-

... More
Description all as per Ser item No 6.00 here-in-before but drawn through including on new surface conduit PVC rigid non metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.

50

-

-

... More
Description all as per Ser item No 6.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.

150

-

-

... More
Description all as per Ser item No 12.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.

100

-

-

... More
Supply and fixing socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and as directed.

250

-

-

... More
Supply and fixing LED lights fitting 1 x 20 W, 220 V, AC decorative type complete with LED tube rod 20 watts driver, holder and power factor 0.95, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.

1350

-

-

... More
Material and labour for point wiring for one light/ fan/ call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/ 1.8mm wall thickness ISI marked including pressed steel modular metal flush boxes with suitable white cover plate with frame of any way i.e. (1 to 12 way as per site requirement) for mounting modular switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.

250

-

-

... More
Supply and fixing socket outlet 2 in 1, 3 pin, 5 A 240 volts complete all as specified and as directed.

350

-

-

... More
Supply and fixing PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 5 amp 240 volt complete all as specified and as directed.

30

-

-

... More
Supply and fixing modular switch 1 way 16A, 1 module, 240 volts ISI marked complete all as specified and as directed.

80

-

-

... More
Supply and fixing in replacement Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar including taking down old unserviceable distribution board/ MCB any type complete all as specified and as directed. Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN distribution board and MCCB should be of same make.

10

-

-

... More
Supply and fixing socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.

120

-

-

... More
Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.

350

-

-

... More
Supply and fixing in replacement of 5 to 32 Amp MCB 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.

350

-

-

... More
Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.

4201

-

-

... More
Supply and fixing socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.

100

-

-

... More
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.

35

-

-

... More
Material and labour copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.

300

-

-

... More
Supply and fixing switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts complete all as specified and as directed.

350

-

-

... More
Description all as per Ser item No 2.00 here-in-before but for One 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.

120

-

-

... More
Material and labour for point wiring for one light/ fan/ call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into new concealed PVC rigid/ 1.8mm wall thickness ISI marked including cast iron/ pressed steel terminal boxes and 3.00mm thick hylum brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof/ ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.

220

-

-

... More
Supply and fixing MCB TPN 40 to 125 Amp in the distribution board complete with connection, testing and commissioning complete all as specified and as directed.

10

-

-

... More
Supply and fixing plug top 15 Amps complete all as specified and as directed.

100

-

-

... More
Supply and fixing modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and as directed.

50

-

-

... More
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.

20

-

-

... More
Material and labour in replacement for copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.

450

-

-

... More
Supply and fixing stepped type electronic fan 120 W regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.

50

-

-

... More
Material and labour for point wiring for one light/ fan/ call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/ steel conduit and cast iron/ pressed steel terminal boxes including 3.00mm thick hylum brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof/ ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.

2156

-

-

... More
Description all as per Ser item No 2.00 here-in-before but for One 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.

245

-

-

... More
Supply and fixing fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and as directed.

80

-

-

... More
Supply and fixing switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.

450

-

-

... More
Description all as per Ser item No 2.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.

200

-

-

... More
Description all as per Ser item No 6.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.

200

-

-

... More
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

50

-

-

... More
Supply and fixing fancy light 9/11 watt for false ceiling as per same complete all as specified and as directed.

80

-

-

... More
Material and labour for self ballast LED retrofit lamp with PVC body and PC diffuser 9/15 watt 230 Volt 6500K complete all as specified and as directed.

550

-

-

... More
Description all as per Ser item No 12.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.

150

-

-

... More
Supply and fixing in replacement MCB SPN 32 Amp rating 240V, 10 KA 'B' curve in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.

70

-

-

... More
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.

350

-

-

... More
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and as directed.

200

-

-

... More
Supply and fixing for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and as directed.

200

-

-

... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.

50

-

-

... More
Supply and fixing switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.

450

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.