Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687894_1Bid Award Id
ViewTender No
GE/PNH-63/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for replacement of burnt defective HT/LT copper coil of different type capacity, winding with superior quality enamelled copper winding wire/strips of approved make of suitable size/guage and number of turns matching with the existing impendence and insulated including all allied materials such as cork sheet, fiber glass insulation/paper insulation/Lathoride paper, cotton, empire tape and wooden blocks, bolts, nuts & washers (Brass) soldering/welding and other packing material etc required for entire winding of coils all as specified and directed by Engineer-in-Charge
420
-
-
... More
M&L for HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber oil seal suitable for transformer of any make/type/capacity in repairs, complete all as specified and directed by Engineer-in-Charge
9
-
-
... More
M&L for LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber oil seal suitable for transformer of any make/type/capacity upto 250 KVA in repairs all as specified and directed by Engineer-in-Charge
18
-
-
... More
M&L for replacement of Top gasket sheet made out of 6mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity, complete all as specified and directed.
2
-
-
... More
M&L for replacement of dehydrating breather assembly CI body of standard size filled with silica -gel for transformer of capacity upto and including 315 KVA, complete all as specified and directed.
4
-
-
... More
M&L for replacement of temperature gauge circular dia type of standard size for transformer of capacity upto and including 315 KVA , complete all as specified and directed.
2
-
-
... More
M&L for tap changer assembly & replacement of worn out nuts and bolts and providing new copper lead for tap changer assembly of capacity upto and including 315 KVA complete all as specified and as directed..
1
-
-
... More
M&L for filling in with new transformer oil for top up having low viscosity, of approved make as per IS 355 of 1992 and di-electric strength 60 KV (after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol
1200
-
-
... More
M&L for filtration & dehydration of existing transformer oil including heating continously to achieve results for reuse as per standards including recording its viscosity etc prior & after filtration & dehydration of transformer oil with maintaining its results complete all as specified and directed.
2000
-
-
... More
M&L for repairs to leaking transformers at site up to 315 KVA by opening the top cover, draining the transformer oil to the level just below the bushing, replacing the all four bushing with connecting rod, replacing the oil gaskets of bushings on HT & LT side, replacing the top oil gasket, reassebling, testing etc comlpete all as directed. Note: Replacement of specified parts are deemed to be included in quoted rate
6
-
-
... More
Taking down old servo voltage stabilizer of capacity 25 to 63 KVA, 280 to 400 V, oil cooled un-balanced or balanced servo control from different locations in the area of responsiblity falls under AGE B/R-II area of GE 881 EWS and shifting to authorised workshop and getting back after repair/overhauling by way of replacing unserviceable parts (parts to be measured & paid under relevent items here-in-after as supply only) and refixing the same at original location & connecting electrically and commissioning complete all as specified and directed at site. (Repair shall be carried out in authorised workshop, the rate deemed to including transportation of T&P complete).
3
-
-
... More
Supply only the following items required to incorporate in item as above:-
-
-
-
... More
(a) Servo control motor with base plate, condenser, capacitor, gear etc of existing make all as specified and as directed
2
-
-
... More
(b) Auto control unit
2
-
-
... More
(c) Gear machine
2
-
-
... More
(d) Carbon bushes
2
-
-
... More
e) Main transformer coil
2
-
-
... More
(f) Low/ high voltage cut off switch
2
-
-
... More
(g) Dimmer coil 60 Amps capacity
2
-
-
... More
(h) Dimmer coil 80 Amps capacity
2
-
-
... More
(j) Brass bushes
8
-
-
... More
Taking down old servo voltage stabilizer of capacity 100 to 200 KVA, 280 to 400 V oil cooled un balanced or balanced servo control from different locations in the area of responsiblity falls under AGE B/R-II area of GE 881 EWS and shifting to authorised workshop and getting back after repair/overhauling by way of replacing unserviceable parts (parts to be measured & paid under relevent items here-in-after as supply only) and refixing the same at original location & connecting electrically and commissioning complete all as specified and directed at site. Repair shall be carried out in authorised workshop, the rate deemed to including transportation of T&P complete).
3
-
-
... More
Supply only the following items required to incorporate in item as above:-
-
-
-
... More
(a) Servo control motor with base plate, condenser, capacitor, gear etc of existing make all as specified and as directed
4
-
-
... More
(b) Auto control unit
4
-
-
... More
(c) Gear machine
4
-
-
... More
(d) Carbon bushes
8
-
-
... More
e) Main transformer coil
4
-
-
... More
(f) Low/ high voltage cut off switch
4
-
-
... More
(g) Dimmer coil for 120 Amps capacity suitable for 100 to 200 KVA servo
4
-
-
... More
(h) Brass bushes with suitable insulating material
12
-
-
... More
S &F in repairs Copper thimbles for cable connections of size 25 Sqmm to 120 sqmm complete all as specified and directed
200
-
-
... More
S& F in repairs Copper thimbles for cable connections of size 150 Sqmm to 400 sqmm complete all as specified and directed
100
-
-
... More
Repair/overhauling of air break switch complete by replacing stationary, and moving contacts, fexible copper cord, GI nuts, bolts, etc incl alignment for smooth functioning from ground level all as required at site and as directed by E-in -charge.
15
-
-
... More
Supply and replacement of HT 11 KV outdoor type gang operated air break switch and insulator and steel frame outdoor type suitable for horizontal/vertical insulation single break provided with locking arrangement consisting of MS channel HT post type insulator copper alloys high pressure assembly opening rod of 25mm dia GI pipe medium grade complete conforming to IS-1318 of 1972 rated voltage 11 KV and current rating 200 Amps, 12 insulators, complete all as specified and directed.
10
-
-
... More
Supply and fixing in repairs lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, suitable 11000 Volts complete all as specified and directed.
10
-
-
... More
M&L in repairs disc type insulators, porcelain vitreous white brown or green, 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 11000 Volts complete all as specified and directed.
21
-
-
... More
Supply and fixing in repairs pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line complete all as specified and directed.
100
-
-
... More
Supply and fixing in repairs cable jointing kit for 11 KV (earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 120 Sqmm complete all as specified and directed.
8
-
-
... More
M&L to replacement of moving contact of GOD of brass type male and female and making functional complete all as directed by Engr-In-Charge.
7
-
-
... More
Supplying, fixing, jointing and testing in replacement heat shrinkable straight through joint with and including jointing materials & accessories suitable for 11 KV(E) , XLPE cable of size 95 sqmm , 3 core , complete all as specified and directed .
2
-
-
... More
M&L for Painting to transformer/voltage stabilizer of any make/any size including XPM wire mesh complete, by spraying with two coats of synthetic enamel paint of first quality dark grey/ivory colour paint over a coat of red oxide primer after and including complete removal of old paint and primer by scratching, rubbing and marking SM No complete all as specified and directed.
8
-
-
... More
M&L for Painting to steel tubular pole including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, GOD complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
40
-
-
... More
M&L for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI thimbles, bolt nuts, check nuts and washers of including providing earth wire protection pipe GI medium grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover and suitable handle, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009), incl dismantling of existing earthing complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
M&L for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 3mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 20 x 3mm as earth continuity conductor connected to earth plate by means of GI thimbles, bolt nuts, check nuts and washers of including providing earth wire protection pipe GI medium grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover and suitable handle, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009), incl dismantling of existing earthing complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply, laying in trenches, testing and commisioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts earth grade having cross sectional area 95 Sqmm 3 core, incl taking out old cables complete all as specified and directed.
700
-
-
... More
Supply and fix aerial bunched cable 11 KV grade stranded and compact aluminium phase conductor of size 3 x 95 sqmm + 1 x 70 Sqmm (bare massenger) with copper alloy, the phase conductor should be insulated with XLPE compound copper, CONFORMING TO is 14225-1995 incl all fittings such as anchor clamp , suspension clamp in line connector, service clamp, insulation piercing connectors for taps from bare lines etc, incl taking out old cables complete all as specified and directed.
300
-
-
... More
Supply and laying GI tubes light grade, galvanised, 80mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete incl taking down old us pipe any size all as specified and directed.
36
-
-
... More
Taking out old unserviceable rubber matting and supply and laying new rubber insulating matting (chequered type), 11000 volts grade of size 2m x 1m x 12 mm complete all as specified and directed.
4
-
-
... More
Dismantling concrete poles/steel poles/struts, any size any type and removing from site all as directed by Engr-in-Charge at site.
10
-
-
... More
Supply and erecting in true vertical steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, complete all as specified and directed.
(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work).
10
-
-
... More
M&L for cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete including dismantling of old broken cross arms, bracings, supports, clamps, etc. complete all as specified and directed.
10
-
-
... More
M&L for stay assembly complete with accessories i.e. stay plate 300mm x 300mm x 6mm, galvanised thimbles, GI stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 on Ser Page No 495 of MES Schedule Part-I (2009) complete including dismantling existing stay assembly complete all as specified and directed.
4
-
-
... More
M& L for Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 4mm dia , complete all as specified and directed.
0.5
-
-
... More
M& L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size Complete all as specified and directed.
10
-
-
... More
Dismantling OH ACSR Conductor from the existing LT /HT pole, complete all as specified and directed.
5
-
-
... More
Supply, stringing, streaching and binding with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections all as specified & directed.
5
-
-
... More
Trimming tree branches coming in proximity to HT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 1.5 Mtrs apart from ACSR conductor from all sides all as directed.. (Contactor is required to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost ). Note:- Five lines together will be measured as one span from pole to pole.
200
-
-
... More
Re-stretching of loose over head ACSR conductor/AB Cables/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. (Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge)
50
-
-
... More
Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed
191
-
-
... More
Exc in trenches not exc. 1.5 m wide and exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed
2.5
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
131
-
-
... More
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
62
-
-
... More
Supply and laying Sand cushioning for the purpose of floors and laying of cables including watering and consiolidation.
32
-
-
... More
S & L brick covering with width equal to length of brick as the mechanical protction to cable of common burnt clay, sub class B , designation 75, laid in trenches flat complete all as specified and directed.
2.2
-
-
... More
M&L for Construction of platform suitable for Transformer, of size 3.0m x 3.0m x 01 m (Platform shall be made of one brick thick built in cement mortar (1:4) brick masonary 30cm below ground level and 30 cm above ground level, hollow space 500mm thick shall filled with PCC (1:3:6) type C-2,over well rammed and watered earth, and floor of platform shall be 100 mm thick in cement concrete (1:2:4) type B-2 ,exposed surface of platform shall be plastered 15mm thick in cement mortar (1:4), complete all as specified and directed by Engr-in-Charge at site.
4
-
-
... More
M&L for filling of 40 mm graded crushed stone aggregates around the plinth of transformer/ panels/two pole/four pole structures including making brick wall (300 mm below and 300 mm above ground) for protection of aggregates and making plaster of wall ,and as directed by Engr-In-Charge
3
-
-
... More
M&L for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
3
-
-
... More
M&L of PCC for steel tubular poles (1:4:8) Type D-2 using 40 mm graded aggregate for mass filing of poles complete all as specified and directed at site.
4
-
-
... More
M&L for Coping for steel tubular poles (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.
2
-
-
... More
S&F shock treatment chart complete with figures as per electricity rules including leminated with lemination sheet and as directed by Engr-In-Charge.
6
-
-