Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Mar 2025
Closing Date21 Apr 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Summary

Repair/maint Of Pumps,motors,starters,voltage Stabilizers Etc At Y Station, Ridge Area, Raipur Satwari And 166 Mh Under Age E/m Of Ge Satwari

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Disconnecting electrical connections from the panel & VT motor to the pump set and lifting of unserviceable VT pump of any capacity from the bore well upto 40 Mtr's including column pipe and other accessories,carrying to workshop for repair,taking back after repair & lowering, jointing the same in orignal position/location with column pipe, motor and other accessories, connecting to all electrical connections, testing and commissioning including replacement of all nut,bolt washer & gasket etc as required at site complete all as specified and directed. Note: (i) The cost of transportation to and from workshop and T&P required for lifting of pump is deemed to be included in the quoted rate. (ii) Spare parts required shall be measured and paid seperatly under relivent items. (iii) If there is any mishappening during lowering of pump and motor to the tube well, the quoted rate shall be deemed to be included for the same.

5

-

-

... More
Repair/opening & overhauling of VT pump set by dismantling (in r/o ser item No 04),cleaning , servicing,replacement of minor spare parts including fixing of major parts required for proper functioning, re-assembling after repair complete all as specified and directed. Note: (i) Major spare parts required shall be measured and paid seperatly under relevant items 06 to 18 as "Supply only" .

5

-

-

... More
Supply only Gun metal impeller as per existing size.

18

-

-

... More
Supply only Neck Ring as per existing size.

15

-

-

... More
Supply only Gland plate as per existing size.

3

-

-

... More
Supply only Studs as per existing size.

24

-

-

... More
Supply only Stainless steel lineshaft 3 metre long as per existing size.

24

-

-

... More
Supply only Top shaft 1.5 metre long as per existing size.

5

-

-

... More
Supply only Guide spider 6" as per existing size.

24

-

-

... More
Supply only Guide spider bush as per existing size.

24

-

-

... More
Supply only Stainless steel sleeve as per existing size.

24

-

-

... More
Supply only Shaft coupler as per existing size.

24

-

-

... More
Supply only Stuffing box as per existing size.

2

-

-

... More
Supply only Thrust bearing as per existing size.

6

-

-

... More
Supply only Cast iron impeller housing as per existing size.

9

-

-

... More
S&F in replacement of mild steel column pipe 50 mm size (heavy grade) inside the bore well to header including both side flange ends welded in every three mtr along with nut, bolt ,washer and gasket including painting with synthetic enamelled paint over a coat of primer complete all as directed .

12

-

-

... More
S&F in replacement of mild steel column pipe 80 mm size (heavy grade) inside the bore well to header including both side flange ends welded in every three mtr along with nut, bolt ,washer and gasket including painting with synthetic enamelled paint over a coat of primer complete all as directed .

18

-

-

... More
S&F in replacement of mild steel column pipe 100 mm size (heavy grade) inside the bore well to header including both side flange ends welded in every three mtr along with nut, bolt ,washer and gasket including painting with synthetic enamelled paint over a coat of primer complete all as directed .

24

-

-

... More
S&F in replacement of mild steel column pipe 150 mm size (heavy grade) inside the bore well to header including both side flange ends welded in every three mtr along with nut, bolt ,washer and gasket including painting with synthetic enamelled paint over a coat of primer complete all as directed .

24

-

-

... More
Disconnecting electrical connections from the panel and lifting out unserviceable submersible pump and motor of capacity 17.5 HP to 35 HP including column pipe and other accessories from tube well of depth 35m , carrying to workshop for repair and taking back to original location after repair complete all as specified and directed. (i) The cost of transportation to and from workshop and T&P required for lifting of pump & motor is deemed to be included in the quoted rate. (ii) Spare parts required shall be measured and paid seperatly under relivent items. (iii) If there is any mishappening during lifting of pump and motor to the tube well, the quoted rate shall be deemed to be included for the same.

10

-

-

... More
All as per Srl item No 23 here in before but of capacity 25 to 30 HP from the depth of tube well upto 150m.

2

-

-

... More
All as per Srl item No 23 here in before but of capacity 7.5 HP from the depth of tube well upto 40m.

2

-

-

... More
M&L for lowering of submersible pump with motor of capacity 17.5 HP to 35 HP into tube well of depth upto 35m , jointing with column pipe and other accessories, connecting to all electrical connections, testing and commissioning including replacement of all nut,bolt, washer & gasket with new one and binding the submersible cable with colum pipe etc as required at site complete all as specified and directed . Note: (i) The cost of T&P required for lowering of submersible pump with motor to the borewell is deemed to be included in the quoted rate. (ii) Spare parts required shall be measured and paid seperatly under relivent items. (iii) If there is any mishappening during lowering of pump and motor to the tube well, the quoted rate shall be deemed to be included for the same.

10

-

-

... More
All as per Srl item No 26 here in before but of capacity 25 to 30HP, the depth of tube well upto 150m.

2

-

-

... More
All as per Srl item No 26 here in before but of capacity 7.5 HP, the depth of tube well upto 40m.

2

-

-

... More
M&L for strip opening of submersible motor of capacity up to 7.5 HP, taking out rotor from stator, taking out burnt winding from the stator, cleaning the core and rewinding the same with insulated copper wire of existing gauge including other winding material and re-assembling complete all as specified and directed.

2

-

-

... More
All as per Srl item No 29 here in before but of capacity 15 HP to 20 HP

3

-

-

... More
All as per Srl item No 29 here in before but of capacity 25 HP to 35 HP

7

-

-

... More
M&L in replacement of thrust plate as per existing size of submersible motor of capacity 7.5 HP complete all as specified and directed.

2

-

-

... More
M&L in replacement of thrust plate as per existing size of submersible motor of capacity 17.5 HP complete all as specified and directed.

2

-

-

... More
M&L in replacement of thrust plate as per existing size of submersible motor of capacity 25 HP to 35 HP complete all as specified and directed.

8

-

-

... More
M&L in replacement of thrust bearing and base with pad as per existing size of submersible motor of capacity 7.5 HP complete all as specified and directed

2

-

-

... More
M&L in replacement of thrust bearing and base with pad as per existing size of submersible motor of capacity 17.5 HP complete all as specified and directed

2

-

-

... More
M&L in replacement of thrust bearing and base with pad as per existing size of submersible motor of capacity 25 HP to 35 HP complete all as specified and directed

8

-

-

... More
M&L in replacement of rubber bushes as per existing size of submersible motor of capacity 7.5 HP complete all as specified and directed

2

-

-

... More
M&L in replacement of rubber bushes as per existing size of submersible motor of capacity 17.5 HP complete all as specified and directed

2

-

-

... More
M&L in replacement of rubber bushes as per existing size of submersible motor of capacity 25 HP to 35 HP complete all as specified and directed

8

-

-

... More
M&L in replacement of alignment, grinding, polishing and balancing of shaft of submersible motor of capacity 7.5 HP to 17.5 HP complete all as specified and directed.

2

-

-

... More
M&L in replacement of alignment, grinding, polishing and balancing of shaft of submersible motor of capacity 25 HP to 35 HP complete all as specified and directed.

6

-

-

... More
M&L in replacement of coupling arrangement with key as per existing size of submersible motor of capacity 7.5 HP to 17.5 HP complete all as specified and directed.

3

-

-

... More
M&L in replacement of coupling arrangement with key as per existing size of submersible motor of capacity 25 HP to 35 HP complete all as specified and directed.

8

-

-

... More
M&L in replacement Seal guide sleeve of 25 to 35 HP submersible Motor as existing make and size complete all as specified and directed

8

-

-

... More
M&L in replacement Seal guide sleeve of 7.5 to 20 HP submersible Motor as existing make and size complete all as specified and directed

4

-

-

... More
M&L in replacement Cable connector sleeve guide plate of 25 to 35 HP submersible Motor as existing make and size complete all as specified and directed

8

-

-

... More
M&L in replacement Cable connector sleeve guide plate of 7.5 to 20 HP submersible Motor as existing make and size complete all as specified and directed

4

-

-

... More
M&L in replacement Motor base along with inner plate of 7.5 to 20 HP submersible Motor as existing make and size complete all as specified and directed

4

-

-

... More
M&L in replacement Motor base along with inner plate of 25 to 35 HP submersible Motor as existing make and size complete all as specified and directed

8

-

-

... More
Opening, servicing, cleaning the submersible pump set of various size & capacity for repair, replacement of minor spare parts including fixing of major parts required for proper functioning, re-assembling after repair complete all as specified and directed. Note: (i) Major spare parts required shall be measured and paid seperatly under relevant items 52 to 70 as "Supply only" .

5

-

-

... More
Supply only Stainless steel shaft as per existing size of submersible pump of capacity 7.5 HP

2

-

-

... More
Supply only Stainless steel shaft as per existing size of submersible pump of capacity 17.5 HP to 35 HP

12

-

-

... More
Supply only Impeller as per existing size for submersible pump set 7.5 HP .

2

-

-

... More
Supply only Impeller as per existing size of submersible pump of capacity 17.5 HP to 35 HP .

12

-

-

... More
Supply only NRV as per existing size for submersible pump set of capacity 17.5 HP to 35 HP .

6

-

-

... More
Supply only Bowl bush as per existing size for submersible pump set of capacity 7.5 HP .

2

-

-

... More
Supply only Bowl bush as per existing size for submersible pump set of capacity 17.5 HP to 35 HP .

12

-

-

... More
Supply only Neck ring as per existing size for submersible pump set of capacity 7.5 HP

2

-

-

... More
Supply only Neck ring as per existing size for submersible pump set of capacity 17.5 HP to 35 HP .

12

-

-

... More
Supply only Sand guard assembely of 25 to 35 HP submersible pump as existing make and size.

10

-

-

... More
Supply only Sand guard assembely of 7.5 to 20 HP submersible pump as existing make and size

4

-

-

... More
Supply only Bush housing set including bush of 25 to 35 HP submersible pump as existing make and size .

10

-

-

... More
Supply only Bush housing set including bush of 7.5 to 20 HP submersible pump as existing make and size .

4

-

-

... More
Supply only Upper housing set of 25 to 35HP submersible pump as existing make and size .

8

-

-

... More
Supply only Upper housing set of 7.5 to 20 HP submersible pump as existing make and size.

4

-

-

... More
Supply only Lower housing set of 25 to 35 HP submersible pump as existing make and size.

8

-

-

... More
Supply only Lower housing set of 7.5 to 20 HP submersible pump as existing make and size.

4

-

-

... More
Supply only Tie rod & tie bolt of 25 to 35 HP submersible pump/Motor as existing make and size.

8

-

-

... More
Supply only Tie rod & tie bolt of 7.5 to 20 HP submersible pump/Motor as existing make and size.

4

-

-

... More
Disconnecting electrical connections for taking out unserviceable submersible motor and other accessories of any size from open well ,carrying to workshop for repair, taking back to the existing well after repair , re installation in orignal position including all electrical connections, testing and commissioning complete all as specified and directed. Note: (i) Spare part required shall be measured and paid separatly under relivent items. (ii) The cost of transportation to and from workshop and T&P required for taking out motor is deemed to be included in the quoted rate. .

2

-

-

... More
M&L for removing the burnt winding of open well submersible motor of capacity up to 5 HP, cleaning the slots for rewinding and rewinding the motor with superior quality super enamelled copper winding wire as per exisitng gauge and size, varnishing, drying, replacement of bearings and re-assembling the motor complete all as specified and directed.

2

-

-

... More
Taking out submersible pump from the open well and opening & overhauling, servicing and cleaning and repair, replacement of minor spare parts including fixing of major parts required for proper functioning, re-assembling after repair complete all as specified and directed. Note: (i) Major spare parts required shall be measured and paid seperatly under relevant items 74 to 77 as "Supply only" .

2

-

-

... More
Supply only neck ring as per existing size for submersible pump

2

-

-

... More
Supply only Impeller as per existing size for submersible pump

2

-

-

... More
Supply only thrust bearing as per existing size for submersible pump

2

-

-

... More
Supply only rubber bush as per existing size for submersible pump

2

-

-

... More
Disconnecting electrical connections for taking out unserviceable dozing motor of any size and other accessories from the dozing pump, carrying to workshop for repair,taking back to the existing location after repair , re installation in orignal position including all electrical connections, testing and commissioning complete all as specified and directed. Note: (i) Spare part required shall be measured and paid separatly under relivent items. (ii) The cost of transportation to and from workshop and T&P required for taking out is deemed to be included in the quoted rate. .

15

-

-

... More
M&L for removing the burnt winding wire of the dozing motor of capacity up to 0.5 HP, cleaning the slots for rewinding, and rewinding the motor with superior quality super enamelled copper winding wire as per exisitng gauge and size, varnishing, drying, replacement of bearings and re-assembling the motor complete all as specified and directed.

6

-

-

... More
M&L for disconnecting the dozing pump set and servicing, cleaning, checking and filling the gear oil as per existing make and model of dozing pump set, replacement of minor spare parts including fixing of major parts required for proper functioning, re-assembling after repair complete all as specified and directed. Note: (i) Major spare parts required shall be measured and paid seperatly under relevant items 81 to 91 as "Supply only" .

15

-

-

... More
Supply only PVC NRV set with glass ball for suction and delivery adopter

12

-

-

... More
Supply only PVC adopter for suction and delivery without NRV

6

-

-

... More
Supply only PVC strainer washer type heavy duty or as per existing strainer for suction

6

-

-

... More
Supply only teflon gland square type

12

-

-

... More
Supply only chemical oil seal with cap

4

-

-

... More
Supply only dosing aginator gear box 25 LPH

4

-

-

... More
Supply only S.S agitating rod with fan, PP coating

4

-

-

... More
Supply only Plunger assembly without PVC dosing head 25 LPH

4

-

-

... More
Supply only Plunger assembly with PVC dosing head complete 25 LPH

4

-

-

... More
Supply only Heavy duty PVC pipe for delivery & suction line

5

-

-

... More
Supply only Rubber coupling bush as per existing size or make and model

12

-

-

... More
S&F control panel for dosing Pump suitable for Model SSAPS/SDSPT/25 / or equivalent, made of powder coated MS fabricated box cosisting of LED indicator, digital volt meter, Amps meter, single phase preventor, high voltage low voltage protection, plus buzzer will be on when single phase or high voltage /low voltage passing complete all as specified and directed.

1

-

-

... More
Disconnecting electrical connections for taking out unserviceable centrifugal motor of capacity 7.5 HP to 20 HP and other accessories from the foundation, carrying to workshop for repair, taking back to the existing location after repair , re installation in orignal position including all electrical connections, testing and commissioning complete all as specified and directed. Note: (i) Spare part required shall be measured and paid separatly under relivent items. (ii) The cost of transportation to and from workshop and T&P required for taking out is deemed to be included in the quoted rate.

7

-

-

... More
M&L for removing the burnt winding wire of the centrifugal motor of capacity 17.5 HP to 20 HP, cleaning the slots and rewinding the motor with superior quality super enamelled copper winding wire as per exisitng gauge and size, varnishing, drying, replacement of bearings and re-assembling the motor complete all as specified and directed.

3

-

-

... More
All as per Srl tiem No 94 here-in before but of capacity 10 HP .

3

-

-

... More
All as per Srl tiem No 94 here-in before but of capacity 7.5 HP .

2

-

-

... More
M&L disconnecting centrifugal pump set of any capacity, opening, servicing, cleaning and replacement of minor spare parts including fixing of major parts required for proper functioning, re-assembling after repair complete all as specified and directed. Note: (i) Major spare parts required shall be measured and paid seperatly under relevant items 98 to 115 as "Supply only" .

9

-

-

... More
Supply only impeller as per existing size of centrifugal pump set of capacity 7.5 HP

2

-

-

... More
Supply only impeller as per existing size of centrifugal pump set of capacity 10 HP

4

-

-

... More
Supply only impeller as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP

4

-

-

... More
Supply only gland bush including gland packing as per existing size of centrifugal pump set of capacity 7.5 HP

1

-

-

... More
Supply only gland bush including gland packing as per existing size of centrifugal pump set of capacity 10 HP

4

-

-

... More
Supply only gland bush including gland packing as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP

3

-

-

... More
Supply only ball bearing as per existing size of centrifugal pump set of capacity 7.5 HP

2

-

-

... More
Supply only ball bearing as per existing size of centrifugal pump set of capacity 10 HP

3

-

-

... More
Supply only ball bearing as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP

4

-

-

... More
Supply only center guide as per existing size of centrifugal pump set of capacity 7.5 HP

1

-

-

... More
Supply only center guide as per existing size of centrifugal pump set of capacity 10 HP

2

-

-

... More
Supply only center guide as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP

3

-

-

... More
Supply only pump shaft as per existing size of centrifugal pump set of capacity 7.5 HP to 10 HP

4

-

-

... More
Supply only pump shaft as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP.

3

-

-

... More
Supply only neck ring as per existing size of centrifugal pump set of capacity 7.5 HP to 10 HP

3

-

-

... More
Supply only neck ring as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP.

2

-

-

... More
Supply only tyre coupling as per existing size of centrifugal pump set of capacity 7.5 HP to 10 HP

3

-

-

... More
Supply only tyre coupling as per existing size of centrifugal pump set of capacity 17.5 HP to 20 HP.

2

-

-

... More
Supply, Installation, testing and commissioning in replacement of fully automatic star delta starter (MU-G50) for submersible motor controller of capacity 50HP, 415 Volts, 50/60HZ , Relay range 36-70 Ampere, TP Heavy duty contactors, control relays, timers, auto/manual selector switch for suitable rating with ON, OFF, Trip Indicating Light, Push Buttons, Digital metering of Amps & Volts meter complete all as specified and directed.

1

-

-

... More
All as per ser item No 116 above here-in-before but of capacity 40HP with Relay range 36-60 Ampere TP Heavy duty complete.

1

-

-

... More
All as per ser item No 116 above here-in-before but of capacity 25HP with realy range 25- 40 Ampere TP Heavy duty complete.

2

-

-

... More
All as per ser item No 116 above here-in-before but of capacity 10-15HP with realy range 13- 21 Ampere TP Heavy duty complete.

1

-

-

... More
All as per ser item No 116 above here-in-before but of capacity 06 - 7.5 HP with realy range 9- 14 Ampere TP Heavy duty complete.

2

-

-

... More
S&F in replacement of DOL Starter for 10 H.P. with Heavy duty contactors, control relays of current rating 20 Amps, timers, auto/manual selector switch for suitable rating with ON, OFF, Trip Indicating Light, Push Buttons, fitted in panel board including single phase preventer complete all as specified and directed.

5

-

-

... More
All as per ser item No 121 above here-in-before but of capacity 0.5 HP to 7.5 HP complete.

4

-

-

... More
Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 100 KVA to 250 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.

3

-

-

... More
All as per Ser item No 123 here-in-before but of capacity 50 KVA to 73 KVA

4

-

-

... More
All as per Ser item No 123 here-in-before but of capacity upto 45 KVA

4

-

-

... More
S&F in replacement dimmer coil with supper enameled copper wire for voltage stabilizer of capacity 200-250 KVA complete all as specified and directed.

2

-

-

... More
All as per Ser item No126 here-in-before but of capacity 100 KVA

2

-

-

... More
All as per Ser item No126 here-in-before but of capacity 50 KVA to 73 KVA

4

-

-

... More
All as per Ser item No 126 here-in-before but of capacity upto 45 KVA

3

-

-

... More
Dismantling and Rewinding of dimmer coil with supper enameled copper winding wire including vamishing tapping and insulating material to get same cap 200 KVA.

2

-

-

... More
All as per ser item No130 here-in-before but cap 100 KVA

2

-

-

... More
All as per ser item No130 here-in-before but cap 50 KVA to 73 KVA

4

-

-

... More
All as per ser item No 130 here-in-before but cap upto 45 KVA

2

-

-

... More
M&L for dismantling of primary & secondary coils of capacity 200-250 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.

3

-

-

... More
All as per Ser item No134 here-in-before but of capacity 100 KVA

4

-

-

... More
All as per Ser item No134 here-in-before but of capacity 50 KVA to 73 KVA

4

-

-

... More
All as per ser item No 134 here-in-before but of capacity upto 30-45 KVA

4

-

-

... More
M&L for toping up transformer oil not less than 45 KV strength

200

-

-

... More
M&L for replacement of printed circuit board (PCB) complete all as specified and directed.

24

-

-

... More
M&L for replacement of dimmer brush with carbon brush & brush holder complete all as specified and directed..

22

-

-

... More
M&L for replacement of analog amp meter 96 sqmm, 0-200 amps with CTs complete all as specified and directed.

7

-

-

... More
M&L for replacement of analog volt meter 0-500 volts with selector switch complete all as specified and directed.

7

-

-

... More
M&L Repalcement of internal wiring of circuit board of stabilizers complete as as specified and directed.

9

-

-

... More
M&L for replacement of brass studs fixed for input & output of stabilizer of 100-200 KVA capacity with brass nuts complete all as specified and directed.

21

-

-

... More
M&L for replacement of brass studs fixed for input & output of stabilizer of 50-73 KVA capacity with brass nuts complete all as specified and directed.

12

-

-

... More
M&L for replacement of brass studs fixed for input & output of stabilizer of 20 KVA to 45 KVA capacity with brass nuts complete all as specified and directed.

12

-

-

... More
S&F digital volt meter 0-500 volt with selector switch complete all as specified and directed

6

-

-

... More
S&F digital Amp meter 0-400 Amp with selector switch complete all as specified and directed

5

-

-

... More
S&F indicator lamp set (RYB) complete all as specified and directed

18

-

-

... More
S&F in replacement onload change over switch, 250 Amp, 415V, AC, 4 pole, front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.

2

-

-

... More
All as per Ser item No 150 here-in-before but 200 Amps 415 Volts complete.

1

-

-

... More
All as per Ser item No 150 here-in-before but 160 Amps 415 Volts complete.

2

-

-

... More
All as per Ser item No 150 here-in-before but 100-125 Amps 415 Volts complete.

1

-

-

... More
All as per Ser item No 150 here-in-before but 63 Amps 415 Volts complete.

1

-

-

... More
S&F in replacement PVC insulated and PVC sheathed, flat submersible cable, 6 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections complete all as specified and directed.

90

-

-

... More
All as per Ser item No155 here-in-before but of size 10 sqmm 3 core

60

-

-

... More
All as per Ser item No 155 here-in-before but of size 16 sqmm 3 core

60

-

-

... More
M&L in replacement sub main wiring with four single core stranded copper conductor unsheathed PVC insulated cable, 1100V grade, 25 sqmm, drawn through non-metallic PVC rigid conduit of suitable size and conduit accessories fixed on surface/ recessed as required with 16 sqmm copper conductor cable as earth conductor for three phase wiring including connecting motor stater to motor box complete all as specified and directed.

15

-

-

... More
All as per Ser item No 158 above here-in-before but of size 6 sq mm

18

-

-

... More
All as per Ser item No 158 above here-in-before but of size 4 sq mm

25

-

-

... More
S&F in replacement MS tail piece of size 80 mm, one side flange ended and other side of threaded end for submersible pump complete all as specified and directed.

2

-

-

... More
S&F in replacement MS tail piece of size 100 mm, one side flange ended and other side of threaded end for submersible pump complete all as specified and directed.

2

-

-

... More
S&F in replacement MS tail piece of size 150 mm, one side flange ended and other side of threaded end for submersible pump complete all as specified and directed.

2

-

-

... More
S&F in replacement of MS tia rod ( U Clamp ) of size 25 x 6 mm ,both welded bolt of existing size for holding for submersible pump complete all as specified and directed

5

-

-

... More
M&L in replacement power contactor 3 pole with coil voltage 220 volt, type MNX 70 rating complete all as specified and directed.

3

-

-

... More
M&L in replacement power contactor 3 pole with coil voltage 220 volt, type MNX 110 rating complete all as specified and directed.

3

-

-

... More
M&L in replacement single phase preventor, 440 volt complete all as specified and directed.

5

-

-

... More
Disconnecting the electrical connection from the main panel for repair, taking down starter panel & and replacement of panel wiring, CT's, connector, lugs/thimble etc and re-connection at the same position testing commissioning complete all as specified and directed.

2

-

-

... More
M&L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr below ground level connected to GI strip 25x4mm by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, precast RCC cover slab using reinfocement with XPM weighing not less than 4.00 kg/Sqm with suitable handle made of 12mm round bar including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh ,40mm dia light grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.

6

-

-

... More
M&L for galvanised iron strip 25x4 mm complete all as specified and directed.

24

-

-

... More
M&L for galvanised iron strip 32x6 mm complete all as specified and directed.

18

-

-

... More
S&F in replacement 150mm bore non return valve of CI body, both ends flanged, duly drilled, ISI marked with IS-14846-2000, PN-1.6 having stainless steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing steel plate as required complete all as specified and directed.

1

-

-

... More
All as per Ser item No 172 here-in-before but of size 100 mm bore

1

-

-

... More
All as per Ser item No 172 here-in-before but of size 80mm bore

1

-

-

... More
S&F in replacement 80 mm bore sluice valve of CI body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having stainless steel spindle and check nut including operating wheel cap, fixing with new nuts, bolts, washers and rubber insertion/ packing complete all as specified and directed

1

-

-

... More
All as per Ser item No 175 here-in-before but of size 100 mm bore

1

-

-

... More
All as per Ser item No 175 here-in-before but of size 150 mm bore

1

-

-

... More
S&F in replacement MCCB 200 to 250 Amps, 4 Pole,415 volt, 36 KA, 50 Hz, adjustable type with thermal and magnetic release complete all as specified and directed.

1

-

-

... More
S&F in replacement MCCB 160 Amps, 4 Pole,415 volt, 36 KA, 50 Hz, adjustable type with thermal and magnetic release complete all as specified and directed.

3

-

-

... More
S&F in replacement MCCB 100-125 Amps,TP, 25 KA wih adjustable thermal and magnetic setting complete all as specified and directed.

3

-

-

... More
S&F in replacement MCCB 63 Amps,TP, 25 KA wih adjustable thermal and magnetic setting complete all as specified and directed.

2

-

-

... More
S&F in replacement rotor assembly with bearings brachets & tollerence rings for Decrine dosing pump of Make Declibac complete all as specified and directed.

1

-

-

... More
S&F in replacement of coil 250V, 50 HZ for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement single head feed rate control with shaft for Decrine dosing pump of Make Declibac complete all as specified and directed.

1

-

-

... More
S&F in replacement pump head (Ferrule 1/4" & Duckbill included) for Decrine dosing pump of Make Declibac complete all as specified and directed.

1

-

-

... More
S&F in replacement roller assembly for Decrine dosing pump of Make Declibac complete all as specified and directed.

1

-

-

... More
S&F in replacement pump tube for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement Injection check valve for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement Weighted suction line stainer for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement 3/8" white suction/discharge tubing for Decrine dosing pump of Make Declibac complete all as specified and directed.

18

-

-

... More
S&F in replacement check valve duckbill for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement connecting nut 3/8" with adapter for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement connecting nut 3/8" for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement ferrule 1/4" for Decrine dosing pump of Make Declibac complete all as specified and directed.

4

-

-

... More
S&F in replacement injection valve up to 7 Kg pressure for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement foot valve for dosing unit for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement 25mm bore ball valve for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement PVC diaphram for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement PVC head for Decrine dosing pump of Make Declibac complete all as specified and directed.

2

-

-

... More
S&F in replacement 'O' ring for PVC head for Decrine dosing pump of Make Declibac complete all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.