Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date14 Nov 2024
Closing Date12 Dec 2024
Tender Amount₹ 34,93,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683983_1Bid Award Id
ViewTender No
CWEJP-56/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Dismantling and taking down worn out Pin / Disc insulators 11/33 KV, any shape and size from PCC/Steel tubular poles complete all as specified and as directed.
50
-
-
... More
Dismantling and taking down disturbed GI Wire or cradles from the RCC/Steel Tubular poles complete all as specified and as directed.
1
-
-
... More
Dismanteling and taking down disturbed /corroded Overhead ACSR Conductor of any size from HT Poles and shifting to MES store yard complete all as specified and as directed.
1
-
-
... More
Dsmantling and taking up bent/rusted PCC/Steel tubular pole by breaking PCC ,stacking at site or shifting to MES store yard. complete all as specified and directed.
8
-
-
... More
Dsmantling and taking down unserviceable HT/UG /AB cable from pole or in trench complete all as specified and as directed.
760
-
-
... More
Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a Coat primer, complete all as specified and as directed.
1.5
-
-
... More
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 meters long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and as directed. Note : PCC & Earth work will be measured and paid seperately.
8
-
-
... More
Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 400 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuse , complete all as specified and as directed.
15
-
-
... More
HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.
345
-
-
... More
HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 120 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.
NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
250
-
-
... More
HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 33 KV, ‘Earthed Grade, cross-sectional area 150 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
140
-
-
... More
Cable jointing kit for 11 KV (earthed) heat shrinkable, straight through joint suitable for cross sectional area 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and as directed.
2
-
-
... More
Description all as per Srl item No- 15 above but 120 Sqmm 3 core complete all as specified and as directed.
2
-
-
... More
Cable jointing kit for 11 KV (earthed) heat shrinkable, end joint out door suitable for cross sectional area 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and as directed.
6
-
-
... More
Description all as per Srl item No- 17 above but 120 Sqmm 3 core complete all as specified and directed.
2
-
-
... More
Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitablefor working pressure of 11000 Volts complete all as specified and as directed.
14
-
-
... More
Description all as per item No- 19 above but suitable for working pressure of 33000 Volts , complete all as specified and as directed.
3
-
-
... More
Dismantling and taking down any type of transformers indoor/outdoor,by disconnect HT & LT connections from plinth/ platform/ pole mounted and shifting to workshop Draining out all the transformer oil, dismantling and inspection of transformer core and winding including taking out burnt out winding/insulation of LV / HV coils in the presence of the authorized rep.. and rewinding the damaged core wih suitable gauge of copper winding wire winding, drying out in Heat chamber till specified IR values are obtained and providing new insulation materials, gasket, nuts , bolts, checking of leakages and rectifying the same by welding etc and conducting all tests as per IS 6792-1972 as specified, for transformer ,complete all as specified and as directed. Note:- (a) Required tools & plant including lifting arrangement, transport etc shall be included in the rate quoted. (b) Any damage occurred during lifting/ transporting, the firm will be responsible to rectify such defect free of cost.
-
-
-
... More
50 KVA to 160 KVA complete all as specified and as directed.
5
-
-
... More
200 to 400 KVA complete all as specified and as directed.
3
-
-
... More
Rewinding (Double paper covering) of HT coils of any size and type of transformer including cleaning the burnt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled copper winding wire including filling insulation paper etc complete all as specified and as directed. Note :- (i) Burnt coils shall be handed over to the contractor by the Engineer-in-Charge through issue voucher for rewinding giving reference of transformer i.e. make Capacity, MES/SM number of transformer etc.
(ii) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM.
((iii) Work of rewinding work shall be carried out throught OEM or their authorised vendor only. (iv) Old winding copper wire shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor due payment.
350
-
-
... More
Description all as per item No 22 above but of LT coils of any size and type of transformer including cleaning the burnt out insulating materials, brazing and rewinding with appropriate turns and size of super enamelled copper winding wire including filling insulation paper etc complete all as specified and as directed.Note :- (i) Burnt coils shall be handed over to the contractor by the Engineer-in-Charge through issue voucher for rewinding giving reference of transformer i.e. make Capacity, MES/SM number of transformer etc.
(ii) Weight, number of turns, gauge, insulation of winding wire shall be as per OEM.
((iii) Work of rewinding work shall be carried out throught OEM or their authorised vendor only. (iv) Old winding copper wire shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor due payment.
290
-
-
... More
Replacement of silica gel of breather including providing silica gel as per the existing size / model complete all as specified and as directed.
10
-
-
... More
Replacement of breather assembly complete with first fill of silica gel for 63 KVA-400 Kva transformer as per existing make and size complete all as specified and as directed.
5
-
-
... More
Replacement of temperature gauge as per the existing size / model complete all as specified and as directed.
5
-
-
... More
Replacement of burnt out/ damaged LV bushes with porcelain insulator and replace with Brass LV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and as directed.
30
-
-
... More
Dehydration / Filtration of transformer oil by using Filter Plant and till obtaining the oil dielectric strength 60 KV including topping up of transformer oil to the required level in various transformers located outdoor / indoor sub stations complete all as specified and as directed.
6000
-
-
... More
Supply and charging topping up of new low viscosity transformer oil from sealed drums confirming to IS 335-1993 Part-II after testing the correct dielectric strength up to 45 KV duly de-hydrated complete all as specified and as directed.
400
-
-
... More
Preparation of old painted steel or iron surfaces of transformer of 50 to 400 KVA , 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and as directed.
15
-
-
... More
Excavation in trenches, in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of soft / loose soil complete all as specified and as directed.
310
-
-
... More
Description all as per Item No 31 above but depth exceeding beyond 1.5mtr and not exc 3 metre complete all as specified and as directed.
1
-
-
... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
90
-
-
... More
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
220
-
-
... More
Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and as directed.
70
-
-
... More
Well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed.
6
-
-
... More
GI Pipe light grade 80 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and as directed.
18
-
-
... More
Stay assy complete with accessories as shown in electric plate No.1 stay rod 16mm incl taking down complete (loop type insulator stay clamps excavation & concrete measured separately) complete all as specified and as directed.
3
-
-
... More
Replacement pin type porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle, two G I washers and one G I nut, 150 mm height and 150 mm dia suitable for 11000 Volts grade complete all as specified and as directed.
15
-
-
... More
Description all as per Srl item No 39 herein before but 33000 Volts grade complete all as specified and as directed.
10
-
-
... More
Replacement for Disc Insulator porcelain viterous ,Whit/Brown/Green 145mm high and 255 mm dia ball and socket type for working 11000Volts complete all as specified and as directed.
15
-
-
... More
Description all as per Srl item No 41 herein before but 33000 Volts grade complete all as specified and as directed.
10
-
-
... More
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete for poles / stays complete all as specified and as directed.
8
-
-
... More
Plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate for coping incl necessary formwork complete all as specified and as directed.
15
-
-
... More
Galvanised Steel Wire 3.15 or 4.0mm dia as Earth Continuity Conductor and fixed to Pole, binding with Aluminium Binding Wire, complete all as specified and as directed.
0.5
-
-
... More
Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, complete all as specified and as directed.
0.5
-
-
... More
Painting to steel tubular pole 11.0 metre long with two coats of synthetic enamel silver up to below 1.5M from Top edge and 1.50 metre height from ground level in 30 cm alternative black and red strips and remaining portion with alluminium paint incl numbering of pole no by stensils and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and as directed.
190
-
-
... More
Descrition all as per Srl item No 47 above but two pole structure
6
-
-
... More
Description all as per Srl item No 47 above but four pole structure complete all as specified and as directed.
4
-
-
... More
Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT poles, 25 x 20 cm size including taking out old unserviceable danger notice plate complete all as specified and as directed.
50
-
-
... More
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete all as specified and as directed.
10
-
-
... More
Description all as per Srl item No 51 herein before but with Galvanized iron strip of size 32 x6mm complete all as specified and as directed.
14
-
-
... More
Disconnecting HT supply and taking out defective trolley of VCB HT 11 KV, 400/630/800 Amps of any made and type and servicing of trolley of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components all as directed inserting in trolley. testing commissioning and putting on the supply on load complete all as specified and as directed.
4
-
-
... More
Supply only in replacement of vacuum interrupter type WL-33379( 4 inch dia) suitable for HT VCB 630 Amps complete all as specified and as directed.
2
-
-
... More
Supply only Tripping & closing coil 30 V DC complete all as specified and as directed.
1
-
-
... More
Supply only Programmable digital AM meter (142 x 142mm) complete all as specified and as directed.
1
-
-
... More
Supply only Spring charge motor 220V DC complete all as specified and as directed.
1
-
-
... More
Supply only DYDAC control heavy duty connector plug 24 pin complete all as specified and as directed.
1
-
-
... More
Supply only Electronic panel hooter with multi tone & multi voltage complete all as specified and as directed.
1
-
-
... More
Supply only complete operating mechanism complete all as specified and as directed.
1
-
-
... More
Supply only head tripping coil and accessories complete all as specified and as directed.
1
-
-
... More
Supply only HT bushing complete all as specified and as directed.
1
-
-
... More
Supply only CTS wiring system complete all as specified and as directed.
1
-
-
... More
Supply only LED lamp 220 VAC/30V DC complete all as specified and as directed.
1
-
-
... More
Rewindiing of High speed motor for auto charging od VCB complete all as specified and as directed.
1
-
-
... More
Supply only head tripping coil and including accessories complete all as specified and as directed.
1
-
-
... More
Supply only breaker control switch 32A complete all as specified and as directed.
1
-
-
... More
Replacement of Motor & Gear assy 220 Volt AC, UMG-14 type suitable for HT VCB 630 Amps complete all as specified and as directed.
1
-
-
... More
Filling, spreading & levelling of finished gravel of size not more than 40 mm uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and as directed.
20
-
-
... More
Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc complete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
1.5
-
-
... More
Restringing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wirecomplete all as specified and as directed. NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
5
-
-
... More
Replacement of HT 11 KV current transformer double wound cast resin type of ratio 150/75/5+5, 200/100/5+5, 60/30/5+5 Amps make and modle as per existing complete all as specified and as directed.
3
-
-
... More
Replacement of HT 11 KV PT HRC fuse complete all as specified and as directed.
3
-
-
... More
Replacement Mild steel chequered plate 5mm thick Fe 410w (Gde-E.250) (in replacement of broken PCC duct cover) complete all as specified and as directed.
150
-
-
... More
Calibration of IDMT relay non direction type of 11 KV HT VCB with calibrating machine with respect to time and fault level and alignment of disc spring complete including replacing of auxiliary coil/contact/bridge rectifier/electro magnet/spacer if required complete all as specified and as directed.
3
-
-
... More
Cutting of green growth and wild grass by manual labour or by machine at electrical installation premises,around the pole,along the fencing,removing rubbish from the site of work and depositing where directed not exc 100 Mtr from the starting point. complete all as specified and as directed. Note :- The item shall be operated maximum 4 times in the entire period of the contract and the measurement will be taken every time independently for the payment.
500
-
-
... More
Cutting and trimming of tree branches to clear the over head lines in the arc of HT over head lines/feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees branches) and removal of trimmed branches of trees and depositing the same in waste bin inside the campus complete all as specified and as directed. ( Span length not more then 50 Mtr).
100
-
-