Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Dec 2024
Closing Date18 Jan 2025
Tender Amount₹ 16,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special repair/replacement of unserviceable earthing, LT panel and its allied services at Basoli under GE Basoli
Special repair/replacement of unserviceable earthing, LT panel and its allied services at Basoli under GE Basoli
Special repair/replacement of unserviceable earthing, LT panel and its allied services at Basoli under GE Basoli
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)

26

-

-

... More
Supply and laying un-reinforced precast concrete cable cover laid width wise factory made, class LV type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.

2880

-

-

... More
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and directed.

49.84

-

-

... More
M & L PCC (1:2: 4) type BO, using (12.5 mm graded crushed stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grounting of porcelain insulator, complete all as specified and directed

1

-

-

... More
Supply and spread and leveling of gauge not exceeding 40mm size graded coarse aggregate in loose filling over dress earth surface in the installation yard complete all as specified and directed.

20

-

-

... More
Supply & fixing in repair air termination single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on roof, complete all as specified and directed

40

-

-

... More
S & F in repair aluminium strip of size 25 x 3.15 mm fixed with suitable saddles & fixing screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor, complete all as specified and directed

620

-

-

... More
S & F in repair GI strip 32 mm x 6 mm on wall for down conductors or as earth continutty conductor, complete all as specified and directed.

100

-

-

... More
S & F in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall , complete all as specified and directed.

8

-

-

... More
S & F vitreous china porcelain insulator with busbar support white type, complete all as specified and directed.

550

-

-

... More
M&L Chemical earthing complete with copper plate electrode (98 percent conductivity when annealed) 900 mm x 600 mm x 5 mm thick buried directly in ground ( Earth pit not less than 2.25 Metres deep below normal ground level and 1.3 mtr wide) with top edge of the plate not less than 1.5 mtr below ground level earth plate connected to copper strip (98 percent conductivity when annealed) 32 x 6mm (drawn in and including earth lead protection pipe light grade GI of size 50 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in Plate No 2 of SSR Part I connected to earthing lead , filling with Charcoal 400 KG , dust and common salt 325 KG and Magnesium sulphate 100 KG, necessary excavation and earth work in any type of soil, perforated watering pipe , funnel with wire mesh, earth lead protection pipe light grade PCC Chamber 1: 3 :6 type C1 ( for even finish on both the faces ) and RCC cover 1:2:4 type B1, 550 x 550 x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 nos of handles of 10 mm dia Steel rod 500 mm Long all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc complete as in repairs all as specified and as directed. Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost

6

-

-

... More
M&L for earthing with GI earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m below ground level) with top edge not less than 1.5m below normal ground level connected with GI dtrip including necessary excavation and earth work in any type of strata, removing surplus soil, to a distance not exc. 50m, PCC chamber in PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate, mild steel angle frame of size 40 x 40 x3mm linged with 10mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40mm dia light grade GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Note :- i) The earth chamber shall be constructed 0.50 m from the edge of earth pit with all necessary watering arrangement. The cost for the same is deemed to be included in unit rate of above item.ii) GI pipe required for protection and earth continuity conductor will be measured and paid seperately beyond 7.5 meters.iii) The test point shall be measured and paid seperately.iv) Rate quoted is also inclided retriving old metal parts of existing earthing and depositing to MES store yard.

24

-

-

... More
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 95 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately.

250

-

-

... More
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 70 sqmm 3.5 core, PVC insulated, armoured heavy duty electric cable with aluminum conductor,1100 Volts grade, complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately.

220

-

-

... More
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 50 sqmm 3.5 core, PVC insulated, armoured heavy duty electric cable with aluminum conductor, 1100 Volts grade, complete all as specified and directed. Note : (I) Earth work/ sand cushioning shall be measured and paid separately.

250

-

-

... More
Taking down/ dismantling of old unsv LT cable complete all as specified and directed.

720

-

-

... More
Find out Fault in existing U/G LT/ cables laid below earth surface in any location of Basoli Area by the expert engineers team of state electricity board authorised under using and hiring of LT fault loactor complete all as specified and directed. Note : LT Straight through Joint kit will be paid and measured seperatly in relevent item of BOQ.

5

-

-

... More
M&L for boring under road with trench less tecnology including DWC HDPE pipe of required dia complete for protection of LT cable complete all as specified and directed.

10

-

-

... More
Supply & laying 40mm bore G I tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc complete all as specified and directed.

50

-

-

... More
Supply & laying 50mm bore G I tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc complete all as specified and directed.

20

-

-

... More
M&L for straight through joint outdoor type of size 25 to 50 sqmm 3.5 core for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables complete all as specified and directed.

3

-

-

... More
M&L for straight through joint outdoor type of size 70 to 95 sqmm 3.5 core for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables complete all as specified and directed.

3

-

-

... More
M&L for straight through joint outdoor type of size 120 to 185 sqmm 3.5 core for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables complete all as specified and directed.

3

-

-

... More
S&F MCCB FP, 36kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x of L&T Make, CAT No. - CM92009OOP1OG including spreader Terminals (CAT No. - ST98053OOOO - Set of Six) and extended Rotary Handle (CAT No. - CM99860OOOO) or equivalent as per Appendix 'F' of list of make.

2

-

-

... More
S&F MCCB FP, 36kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x of L&T Make, CAT No. - CM92009OOP1OG including spreader Terminals (CAT No. - ST98053OOOO - Set of Six) and extended Rotary Handle (CAT No. - CM99860OOOO) or equivalent as per Appendix 'F' of list of make.

3

-

-

... More
S&F MCCB FP, 36kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x of L&T Make, CAT No. - CM92009OOP1OG including spreader Terminals (CAT No. - ST98053OOOO - Set of Six) and extended Rotary Handle (CAT No. - CM99860OOOO) or equivalent as per Appendix 'F' of list of make.

3

-

-

... More
S&F MCCB FP, 36kA, 125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x In of L&T Make, CAT No. - CM92008OOL1OG including spreader Terminals (CAT No. - CM97785OOOO - Set of Six) and extended Rotary Handle (CAT No. - CM99860OOOO) or equivalent as per Appendix 'F' of list of make.

2

-

-

... More
S&F ON Load change over switch open execution type, 4 Pole, 250 Amps rating of L&T make, CAT No. - CO32500OOOO including operating handle - CAT No- CX40001OOOO or equivalent as per Appendix 'F' of list of make.

1

-

-

... More
S&F in repairs Glow sign board of size 1.5 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterier and interior side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin LED tubelight fitting 1x22 watt (2 Nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 metre) copper wire with drilling and necessary required arrangement for fixing of board including testing complete all as spcified and directed.

6

-

-

... More
M&L for dismantling of existing panel including disconnecting cables, etc. and design, supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, made out of CRCA sheet 3.15mm thick duly powder coated with Seimens grey shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2.00 mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised design with single door system for each compartment for each control gear with provn of side cable alley for outgoing cables. Outer cubicle must be extendible in both ends having both sides door openable and should be provided with suitable louvers for ventilation. The Bus bar rating shall be aluminium -4Nos and each have 1.5 time of incommer MCCB i.e. 500Amp. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes.

1

-

-

... More
The bus bar will be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders. The cubicle should be inclusive of following :Incoming (a). MCCB Four Pole 36kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x In with Spreader Terminals and Extended Rotary Handle - 01 No. MAKE- L&T-CAT NO-CM94006OOT1OG or equivalent in ABB/Siemens/Havells OUTGOING -(a) MCCB Four pole, 36kA,160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x In with Spreader Terminals and Extended Rotary Handle - 01 No.MAKE- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/Havells

-

-

-

... More
(b). MCCB TP, 36kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x In with Spreader Terminals and Extended Rotary Handle - 02 Nos.MAKE- L&T-CAT NO-CM94005OOQ1OG or equivalent in ABB/Siemens/Havells MAKE - Legrand, CAT No. - 0046 60(c). MCCB TP, 36kA,125 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 - 1.0 x In, Adjustable Short Circuit setting: 6 - 10 x In including rotary handle with spreader terminal- 02 Nos. MAKE- L&T/ ABB/Siemens/Havells (d). 4 pole Change over switch front operated handle cap 200 Amp - 02 Nos. (e) Analogue Ammeter alternating current range : 0 - 30 A (4 modules). MAKE - Legrand, CAT No. - 0046 02 or equivalent in ABB/Siemen/Havells (f) Analogue Voltmeter alternating current voltage range : Range 0-500 V - 4 Modules. (g) Ammeter selector switch suitable for line currents with OFF with CT of 16 Amps. MAKE - L&T, CAT No. - 61325 SCB03TDYR or equivalent in ABB/Siemen/Havells (h) Voltmeter selector switches suitable for Voltage between Phases with OFF, 16 Amps. MAKE - L&T, CAT No. - 61312 SCB03TDYR or equivalent in ABB/Siemen/Havells (j) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 3 Each, L&T Make (k). Copper bus bar 500 AMPS rating of size 50X10 MM for R-Y-B phases and for Neutral. (l) Foundation for the panel should provided with PCC 1:2:4 at a depth of 150 MM below G.L. and 500 MM above the G.L. with slot openings for I/C and O/G cables.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.