Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Eprocure
Opening Date29 Oct 2024
Closing Soon25 Nov 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681756_1Tender No
GES/AKH-46/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Description all as serial item No- 2.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
10
-
-
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications with existing sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
15
-
-
Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
115
-
-
Description all as serial item No- 6.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
10
-
-
Description all as per serial item No- 6.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
15
-
-
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
20
-
-
S&F Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
305
-
-
S&F Socket outlet, 5-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
20
-
-
S&F Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
30
-
-
S&F Switch socket combination 2-in-1, 3-pin and 5 pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
35
-
-
S&F Electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd, complete all specified and as directed by Engineer-In-charge.
30
-
-
S&F Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
200
-
-
S&F Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings inlcuding retrofit LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge.
70
-
-
S&F LED tube light fitting, 20 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 20 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge.
140
-
-
S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed.
150
-
-
S&F Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified.
15
-
-
S&F Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-In-Charge.
8
-
-
S&F Sub main wiring in repair (concealed conduits to surfaces) for circuits/ sub main wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
90
-
-
Sub main wiring in repair (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
90
-
-
S&F Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
16
-
-
S&F Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
10
-
-
S&F MCB, Triple Pole and Neutral, 63 Amps, 415 volts 10 KA, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
MCB, Single Pole and Neutral, 40 Amps, 240V, 10KA, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
21
-
-
S&F MCB, single pole, 6 to 32 Amps, 240V, 10KA, 50 Hz, 'C' curve, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
143
-
-
S&F Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
400
-
-
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%.
(ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
6
-
-
M&L for Servicing of ceiling fans of sweep 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed. (Unserviceable parts other than specified in this item if any will be measured seperately).
150
-
-
M&L for Servicing of Exhaust fans of sweep 300mm to 450mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed . (Unserviceable parts other than specified in this item if any will be measured seperately).
10
-
-
Rewinding of ceiling fan motor of size 1200mm/1400mm with super enamelled copper winding wire of existing gauge affter cutting and removing the burnt existing winding including varnishing heating by providing fresh insulating materials complete.
100
-
-
Rewinding of exhaust fan/wall monting fan motor of size 300mm with super enamelled copper winding wire of existing gauge affter cutting and removing the burnt existing winding including varnishing heating by providing fresh insulating materials complete.
6
-
-
All as per Srl Item No-33 here-in-above but for exhaust fan of size 400/450 mm of any make complete all as specified.
1
-
-
S&f in replacement ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete. Make - SKF
12
-
-
S& F in replacement of AC film capacitor 4.0 mfd, 440 volts suitable for any type exhaust fan in FR plastic casing including connection complete. Make - Havells cat ref no. 4.0 mfd / 440V / PLWW / 28x52 or equivalent in Epcos / Usha as approved.
6
-
-
S& F in replacement of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 2.5 mfd / 440V / PLWW / 25x45 or equivalent in Epcos / Usha as approved.
50
-
-
Replacement of old unserviceable fan blades made of MS sheet duly powder coated ,of type make and colour as of ceiling fan suitable for 1200mm sweep ceiling fan of any make incl all accessories complete all as specified.
6
-
-
Replacement of Blade assembly of Exhaust fan with fixing hexagonal nut of size 300 to 450mm of any make.
2
-
-
Replacement of iron Frame of exhaust fan 4 way with welded and painted as directed .
1
-
-
S&F Gun metal bush of exhaust fan
6
-
-
S&f in replacement of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
10
-
-
S&F in replacement of PVC canopy suitable for ceiling fan of any size and make as required.
10
-
-
S&F in replacement of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete.
50
-
-
S&F in replacement of down rod of ceiling fan made of GI pipe medium grade 15 mm bore of length upto 600 mm including cutting, threading, painting etc as required.
12
-
-
Taking down of desert cooler fixed at any position, cleaning internally and externally by scraping all scales dirt etc and repairs to desert cooler to check leakage, tightening ( By replacing screws, nuts and bolts etc ) including painting of desert cooler with spray machine with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer, letters, Refixing of the desert cooler after necessary oilling and greasing of fan and water lifting pump complete all as specified and directed
20
-
-
Supplying in replacement Fan motor 1/6 HP, 230 volt, single phase for the existing desert cooler complete all specified and directed. ( Make Khaitan )
8
-
-
Supplying in replacement Water lifting pump, Vertical type,18 watts, 230 volt, 50 C/S, single phase suitable for desert coolers complete all specified and directed ( Make : Khaitan )
4
-
-
Supplying in replacement Side panel made out of 1.0 mm thick GI sheet, fixed with iron handle suitable for desert coolers of capacity 3000 cfm including two coats of synthetic enamel hammer tone paint over a one coat of red oxide primer on both side of panel complete all specified and directed
4
-
-
Supplying in replacement High density polythene pipe 15 mm dia complete all specified and directed
36
-
-
Supplying in replacement Complete steel body of desert cooler of capacity 3000 cfm duly painted with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer . The body of desert cooler shall be fabricated as under :-
( a ) The top and bottom made out of 1.25 mm thick GI sheet.
( b ) side panels (set of three) made out 1.00 mm thick GI sheet.
( c ) Front grill of suitable size and of approved quality.
2
-
-
Supplying and Replacement Three way water distributor, heavy duty, PVC, including necessary nuts and bolts complete and taking out old distributor complete all specified and directed
2
-
-
Supplying in replacement Selector Switch regulator, suitable for Desert coolers exhaust fan of any make complete all specified and directed
2
-
-
Re-wiring of desert cooler with suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all specified and directed.
10
-
-
Dismanting and taking out Old, Unservicable fan motor from the desert cooler and Rewinding with supper enamel copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed
10
-
-
M& L for fabrication of desert cooler stand made out of MS angle iron 40x40x6mm thick all as per existing size suitable at site incl painting ith two coats of synthetic enameld paint over a coat of red oxide primer coat .
2
-
-
Repairs to voltage stabilizer of any make, single phase with input voltage 135 - 190 V and out put voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc.complete all as specified and directed
1
-
-
All as per item No- 57 here in before but for capacity 03 KVA
1
-
-
All as per item No- 57 here in before but for capacity 01 to 02 KVA
2
-
-
Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in GI pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed.
4
-
-
Replacement of unserviceable heating element of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj.
10
-
-
Replacement of unserviceable thermostat of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj
5
-
-
Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts.
8
-
-
S&F in replacement of Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-In-Charge.Make: Crompton cat part No- CCR-127-36-57-SL-NWH (Aura-I) or equivalent in Phillips/ Havells/ Wipro/Halonix.
6
-
-
S&F in replacement of LED lights suitable for mirror/any other indicated locations, environmental friendly, ultra modern, energy saving, including LED lamp capacity 10 Watt, 2 feet long, connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified, complete all as specified and as directed by Engineer-In-Charge.
Make: Havells/ Philips/ Osram/ Crompton.
25
-
-
S&F in replacement of Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified.
Make: Havells ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Bajaj/ Philips/ Wipro.
10
-
-
S&F in replacement of Decorative, wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base., including LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge.
Make: Havells ordering cat part No-LHDL02160099 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
10
-
-
S&F in replacement of Ceiling fan, metalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 210 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance above 2 MΏ, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top & Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: BAJAJ Model No Energos 28 or Equivalent Makes in Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
6
-
-
Supply and fixing in replacememt of unserviceable exhaust fan 375 mm to 450 mm sweep steel body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed by Engr-in-Charge. Make : Crompton Greaves/Havells/ Bajaj Note: (i) Cutting of walls/wooden panel of any description and making provision of holes etc and making good to the disturbed surface to matching with the existing finish shall also be deemed to have been included in the quoted rates. (ii) The dismantled/UNSV exhaust fan shall be deposited with MES store yard for safe custody and shall be the property of the Deptt.
2
-
-
S&F in replacement of 20 W LED Lamp Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base dimension: Width: 200 mm & Height: 227 mm for Moon 200. Make: Havells ordering cat part No-LHFXBON1TN6F035 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
6
-
-
Supply and fixing in replacememt of unserviceable exhaust fan of 450 mm sweep steel body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed by Engr-in-Charge. Make : Crompton Greaves/Havells/ Bajaj Note: (i) Cutting of walls/wooden panel of any description and making provision of holes etc and making good to the disturbed surface to matching with the existing finish shall also be deemed to have been included in the quoted rates. (ii) The dismantled/UNSV exhaust fan shall be deposited with MES store yard for safe custody and shall be the property of the Deptt.
2
-
-
Supply and fixing in replacement of Star rated Geyser of 25Ltr capacity of any make/design (Vertical or horizontal) including making electric and water supply connections etc complete all as specified and directed.) The dismantled/UNSV Geyser shall be deposited with MES store yard for safe custody and shall be the property of the Deptt.
2
-
-
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
430
-
-
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
11
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
240
-
-
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
190
-
-
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge.
Note: Punned thickness shall be measured.
120
-
-
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
12.5
-
-
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles etc, complete all as specified and as directed by Engineer-In-Charge.
15
-
-
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of stays etc, complete all as specified and as directed by Engineer-In-Charge.
7
-
-
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
3
-
-
Replacement of old damaged, steel tubular poles with new steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, complete all as specified and as directed by Engineer-In-Charge.
Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
3
-
-
Replacement of old unserviceable/ damaged over head conductor with new over head, aluminium conductor, steel reinforced, weasel, from any type/ height of poles including proper binding with existing insulators, complete all as specified and as directed by Engineer-In-Charge.
Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
0.5
-
-
Re-stretching only for aluminium conductor steel reinforced including earth wire, of any size and type, maintaining required sag, fixed poles of any height and type with insulators, fixed with aluminium binding wire including all required labours, tools and plants, including making all necessary connection, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Taking down existing unserviceable/ rusted structural steel in cross arms and replacement with new mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged pin type insulator with new pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and as directed by Engineer-In-Charge.
15
-
-
Replacement of old unserviceable/ damaged shackle type insulator with new shackle Type, Porcelain, vitreous, white, brown or green insulator size 100mm height, 115mm dia including galvanised mild steel straps 31x5mm and insulator bolts of bolts 14mm dia, washers, nuts, for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-In-Charge.
15
-
-
Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule.
3
-
-
Replacement of old unserviceable/ corrosion GI earth wire with new galvanised iron wire as in earth wire or wire guard, cradles, hexagonal/ rectangular, fabricated with galvanised steel wire of 4.0mm dia from any position, LT poles of any type and any height including binding wire, 1.60mm dia, galvanised iron, complete all as specified and as directed by Engineer-In-Charge.
0.7
-
-
Replacement of old unserviceable rubber mat with new synthetic rubber insulating mat for preventing HT shock, thickness not less than 25mm, size 2.00x1.00 mtrs, complete all as specified and as directed by Engineer-In-Charge.
8
-
-
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections , one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
100
-
-
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 16.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
100
-
-
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 20x15cm size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for two wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for three wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for four wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 150.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
100
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 120.0 Sqmm, 3.5-core.
100
-
-
Description all as per serial item No-.98 here in before but for cross-sectional area 95.0 Sqmm, 3.5-core.
120
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 70.0 Sqmm, 3.5-core.
120
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 50.0 Sqmm, 3.5-core.
120
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 35.0 Sqmm, 3.5-core.
150
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 25.0 Sqmm, 4.0-core.
150
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 16.0 Sqmm, 4.0-core.
200
-
-
Description all as per serial item No- 98 here in before but for cross-sectional area 10.0 Sqmm, 4.0-core.
200
-
-
Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, 'light grade', galvanised, 50mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
18
-
-
Description all as serial item No- 107 here-in-before but for 40mm bore pipe.
30
-
-
Earthing for poles, complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire of 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
4
-
-
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
4
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, tripple pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 125 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 160 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 200 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 250 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.
1
-
-
Supply and fix in replacement of aluminium lugs for cable size 10.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 16.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 25.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 35.00 sqmm
40
-
-
Supply and fix in replacement of aluminium lugs for cable size 50.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 70.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 95.00 sqmm
30
-
-
Supply and fix in replacement of aluminium lugs for cable size 120.00 sqmm
30
-
-
Trimming/ cutting of tree not exceeding 30cm girth including cutting of trunk, and branches along the over head LT/ HT lines/ poles, in 3.0mtrs radius all around the conductor and disposal of material to a distance not exceeding 50mtrs and clearing site including making surface even with all necessary tools, plants and manpower, complete all as specified and as directed by Engineer-In-Charge.
10
-
-
Cleaning away/ cutting of all grass vegetation, saplings, shrubs, creepers, brushwood, undergrowth, roots and trees not exceeding 30cm girth (measured one metre above ground level) around the LT panels, transformers, and removing rubbish outside the periphery of cantonmant area, complete all as specified and as directed by Engineer-In-Charge.
40
-
-
Design,Supply, installation, testing and commissioning of Cubical type floor mounted LT panel, size 1.00x1.00x.30M depth, outdoor type factory fabricated made out of CRCA sheet of 3.15 mm thick ,fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 250 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete to include the following accessories:- (a) phase indicating lamp and Ampere meter complete with CT and selector switch for three phase current display. (b) MCCB FP 415 volts of capacity 160 amps adjustable type with rupturing capacity 25 KA (incoming)-01 No (c) MCCB, FP 415 volts of capacity 63 amps with rupturing capacity 25 KA-01 No (outgoing). (d) MCB, DP, 230volts, 40Amp of capacity 10KA-5 Nos (outgoing). (e) Indicating Lamps set- 01 (f) Digital ammeter and voltmeter with CTs and switch set- 01 each
1
-
-
Preparation of surfaces of old painted steel tubular swaged poles LT poles of any size, any section, cleaning the surface with mild steel wire brush and complete painting of pole including one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as specified and as directed by Engineer-In-Charge
30
-
-
Preparation of surfaces of old painted steel tubular swaged LT poles of any size, any section, of two pole structure, cleaning the surface with mild steel wire brush and complete painting of pole including one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as directed by Engineer-In-Charge.
3
-
-
Preparation of surfaces of old painted steel tubular swaged HT poles of any size, any section, of two pole structure, cleaning the surface with mild steel wire brush and painting of complete pole including one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as directed by Engineer-In-Charge.
3
-
-
M&L for Gang operated Isolating Switch 11 kV Triple pole vertical type, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps, 15 insulators, including drop out fuse assembly as specified and directed.
2
-
-
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 V.
1
-
-
Amount of Schedule of credit of for Rs 1,45,448.00 shall be deducted from quoted amount.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%