Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Machinery and Tools
Eprocure
Opening Date12 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665702_1Bid Award Id
ViewTender No
GE/PNH-31/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
-
-
-
20 mm dia
490
-
-
25 mm dia
560
-
-
40 mm dia
320
-
-
50 mm dia
350
-
-
S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete laid in trenches, in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
-
-
-
20 mm dia
430
-
-
25 mm dia
380
-
-
40 mm dia
340
-
-
50 mm dia
402
-
-
80 mm dia
374
-
-
100 mm dia
390
-
-
150 mm dia
48
-
-
S&F in repair Gate / globe valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed for following size:-
-
-
-
20 mm bore.
42
-
-
25 mm bore.
46
-
-
40 mm bore
25
-
-
50 mm bore
20
-
-
M&L for construction of brick masonry valve pits of size 100 cm x 100 cm x 105 cm (internal dimension) complete including fabrication of mild steel cover made out of 3 mm thick MS sheet and angle iron frame made out of 40 mm x 40 mm x 6 mm thick and one side provided with hinges and another side provided with locking arranement as per TD drawing held in the office of Engg-in-charge including dismantling the existing unserviceable valve pit complete all as specifeid and directed.
10
-
-
All as per item No 7 above but size 90cm x 90cm x 90cm (internal dimension) complete all as specified and directed.
8
-
-
S&F in repair sluice valve 150mm bore, conforming to IS -14846-2000 PN 1.6 with Steel metal spindle, both ends flanged and drilled with necessary holes for bolts including jointing materials viz nuts, bolts, rubber gaskets etc with iron wheel head including flange joints and making necessary arrangements to fix in position, complete all as specified and directed .
6
-
-
All as per Srl item No. 9 above but 100 mm bore complete all as specified and directed.
7
-
-
All as per Srl item No. 9 above but 80 mm bore complete all as specified and directed.
13
-
-
S&F in repair cast iron reflux valve 150 mm bore, with by pass arrangement, complete all as specified and directed
2
-
-
All as per Srl item No. 12 above but 100 mm bore complete all as specified and directed.
4
-
-
All as per item No. 12 above but 80 mm bore complete all as specified and directed.
12
-
-
All as per item No. 12 above but 50 mm bore complete all as specified and directed.
2
-
-
S&F in repair Cast iron Air Release Valve 150mm bore, with two air outlets complete all as specified and directed
2
-
-
All as per Srl item No. 16 above but 100 mm bore complete all as specified and directed.
2
-
-
All as per Srl item No. 16 above but 80 mm bore complete all as specified and directed.
2
-
-
Supply only chlorination chemical highly efficient (high strength) calcium hypochloride 65% to 70% chlorine content based granular disinfectant more stable in sealed container, no sodium/ iron/ mercury/ heavy metal contaminations, complete all as specified and directed.
Note:
(i) The contractor shall produce manufacturer's test certificate and purchase vouchers of calcium based granular disinfectant.
(ii) Qty shown at column D will not accepted at one time as the material having lesser expiry period.
(iii) The calcium based granular disinfectant shall be brought at site in sealed plastic container.
(iv) Calcium based granular disinfectant shall be of approved make as approved by E-in-C's branch or HQ CENC.
1215
-
-
S&F in repair MS nuts, bolts with washer of any dia and any size as per existing at site complete all as specified and directed.
80
-
-
S&F in repair neoprene rubber gasket suitable for flanges upto 150mm dia pipe not less than 3mm thick of any dia and any size as per existing at site complete all as specified and directed.
120
-
-
S&F in repair CI foot valve of dia 100mm ISI marked with all fittings complete all as specified and directed.
4
-
-
S&F in repair CI foot valve of dia 80mm ISI marked with all fittings complete all as specified and directed.
6
-
-
S&F in repair CI foot valve of dia 50mm ISI marked with all fittings complete all as specified and directed.
6
-
-
M&L for cutting of existing pipe and making arrangements for insertation of NRV and including replacement of NRV of 80/100 mm bore (PN 1.6) and including flanged joint with 3mm thick neoprene rubber gasket including necessary bolts and nuts and necessary earth work complete all as specified and directed.
6
-
-
S&F in repair CI/DI flanged fittings like bends (any radius and angle) tappers any type (straight, bend, increasing, decreasing or double socket), Tee pieces single branch, "Y" junction, double branch, cross (all socket or socket spigot) collars, caps, caps & plug for pipes with spigot or flanged end of any size complete all as specified and directed.
280
-
-
S&F in repair of pressure gauge of 0-150 Psi for 4" dia size and capacity with necessary accessories for fixing complete all as specified and directed.
4
-
-
S&F in repair of old unsv gland packing with new to the valves/pumps sets etc of any sizes/capacity complete with neoprene rubber gasket, jointing material and including nuts/bolts/washers of suitable size complete all as specified and directed.
80
-
-
M&L for leakage rectification by pumping/bailing out of back flow accumulated water in trenches, cutting of existing pipe and making threading/ welding for repair/replacement of unsv fittings, rubber gasket, saddle pieces, nuts, bolts with washer etc, pipe in short lengths (upto 1.5 mtr) for addition and alteration upto 150mm dia CI/DI/MS pipe and including replacement of fittings, rubber gasket, saddle pieces, nuts, bolts with washers etc complete all as specified and directed.
Note: Pipe in short lengths (upto 1.5 mtr), high density rubber sheet, welding work and necessary excavation and earth work as required for making it serviceable is deemed to be included in quoted rate.
86
-
-
M&L for PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregate, as in foundation filling and mass concrete for haunching of pipe of any size complete all as specified and directed.
15
-
-
M&L for replacement of dosing tank suitable for existing at site and as per recommended by manufacturer of declibac technology complete all as specified and directed by Engg-in-charge.
2
-
-
M&L for replacement of shaft with impellar of dosing pump suitable for existing at site complete all as specified and directed by Engg-in-charge.
2
-
-
M&L for replacement of coil 250V, 50 HZ suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of roller assembly, suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of pump tube, suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of injection check valve of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge
2
-
-
M&L for replacement of weighted suction line strainer of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of white suction/discharge tube of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
12
-
-
M&L for replacement of check valve suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of connecting nut of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for replacement of connecting nut with adapter of size 3/8", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
3
-
-
M&L for replacement of ferrule of size 1/4", suitable for dosing pump as existing at site complete all as specified and directed by Engr-in-Charge.
13
-
-
M%L for chemical suitable for RO plant (chemical dosing pump) as recommended by manufacturer complete all as specified and directed by Engg-in-charge.
50
-
-
M&L for servicing of pressure sand filter plant complete in all respect including replacement of necessary parts if required and make it functional, including testing, complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements