Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 Sep 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 87,550Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669724_1Tender No
GE 874/EWS-53/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
80.21
-
-
M&L for PCC 1:4:8, type D-2 (40mm graded Aggregate) in foundations, filling and mass concrete complete all as specified and directed.
8.37
-
-
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified and directed.
72
-
-
M&L for reinforced cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate), nominal mix) as in lintel Bands, gable bands complete all as specified and directed.
6.69
-
-
M&L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in coping, plinth band, bed block including rounded or chamfered angle as directed including necessary formwork etc complete all as specified and directed.
1
-
-
M&L for use and waste of formwork to sides of rough finished surfaces of RCC/PCC bands in walls complete all as specified and directed.
35
-
-
M&L for RCC M-25 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
30.95
-
-
M&L for RCC M-25 (Design mix) as in Columns, pillars, piers, posts and struts etc complete all as specified and directed.
7.58
-
-
M&L for RCC M-25 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
14.2
-
-
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finish flat surface complete all as specified and directed.
172.35
-
-
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunching’s, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc finish with rough finish flat surface complete all as specified and directed.
133.09
-
-
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns, and stanchions, etc finish with rough finish flat surface complete all as specified and directed.
90.21
-
-
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips quality conforming to FE-410-s or FE 410-0 complete all as specified and directed.
4000
-
-
All as per item No-16 above but 6 to 8 mm dia bars as in stirrups/ spacers complete all as specified and directed.
1800
-
-
M&L for rendering 10mm thick plaster on internal face of wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
395.26
-
-
M&L for rendering 15mm thick plaster on external surface of wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
234.38
-
-
M&L for applying two coats of cement base paint over a coat of alkali resistant primer including preparation of newly plaster surface complete all as specified and directed.
234.38
-
-
M&L for applying three coats of white wash on wall including preparation of plastered or un-plastered surfaces of walls, complete all as specified and directed.
395.26
-
-
S&F for 6 mm thick plywood (03 Nos of ply), grade CWR type BB fixed with nails to timber frame work as in ceiling complete all as specified and directed.
162.25
-
-
S & F for 2nd class soft wood as in scantling, clean sawn fixed in unframed work, complete all as specified and directed.
2.5
-
-
S&F for plain fillets, rectangular or triangular in section clean sawn, secured with nails or brads sectional area exc 3 Sqcm & nexc 6Sqcm, second class soft wood (Kail) complete all as specified.
346.25
-
-
M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparing surfaces of wood and wood-based materials of any description not otherwise described over 10 cm width or girth complete all as specified.
155
-
-
M&L for mild steel Fe -410-W(gde-E-250) Quality A Roof trusses (framed), trussed, purlins, posts, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
4995
-
-
M&L for mild steel work for Chimney bars(straight or camber) bearings bars tongoes or water bars for window frames ;Window guard bars ,plain let in and fixed indepandently in window frames ,L or T section supports for shelves etc,and similar articles confirming to Fe-290Gde E-165
350
-
-
M&L for preparing new steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint including a coat of red oxide primer complete all as specified and directed.
112
-
-
S&F steel windows with side hung shutters including projecting type hinges with handle and steel peg stey ,complete with glazing bars ,dovetailed or welded.
9.72
-
-
S&F Steel rolling shutters, Thickness of laths 1.25 mm without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
60
-
-
S&F sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed.
8.5
-
-
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 100mm thick, watered and rammed to a true surface complete all as specified and directed.
24.34
-
-
M&L for moorum/red bajri filling in floors or pavings ,laid in layers n exc 15 cm thick ,spread levelled ,and blinded with earth and rammed including watering all as specified and directed.
16.22
-
-
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub-base complete all as specified and directed.
162.25
-
-
M&L for 50 mm thick PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection, surfaces finished even and fair, complete all as specified and directed.
50
-
-
M&L machine cut Kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement over and including 15 mm thick screed bed in c:m 1:4 over and including 25mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate complete all as specified and directed.
162.25
-
-
All as per item No 36 above but on vertical surface such as skirting, dados, risers to steps, etc., set and jointed in neat cement slurry and pointed in coloured cement to match tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
26
-
-
S&F pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self-tapping screw including necessary scaffolding, any type, any location/height complete all as specified and directed.
275
-
-
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws including necessary scaffolding, any type, any location/ height complete all as specified and directed.
19
-
-
M&L for point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC (FR-LS-H) insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC (FR-LS-H) insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 volts grade including casing and capping (ISI marked) for one light/ fan point controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge including 3mm thick plastic laminated top sheet cover, including cutting chases to wall and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
37
-
-
All as per item No 40 herein before but wiring with 1.5 sqmm copper wire (FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board
9
-
-
All as per item No 40 herein before but wiring with 1.5 sqmm copper wire (FRLSH) and 1.5 sqmm earth wire for switch socket combination 3 pin 5 amps on independent board.
9
-
-
All as per item No 40 herein before but wiring with 2.5 sqmm copper wire (FRLSH) and 1.5 sqmm earth wire for switch socket combination 6 pin 15 amps on independent board.
10
-
-
S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed.
46
-
-
Supply & Fixing Socket outlet 2 in1, 3 pin 5 Amps flush type complete all as specified and directed.
9
-
-
S & F switch socket combination 5 pin 16A, flush type complete all as specified and directed.
10
-
-
S & F switch socket combination 3 pin 5A, flush type complete all as specified and directed.
9
-
-
Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
28
-
-
S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed.
21
-
-
M & L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
9
-
-
Supply and fix LED Bulb 9 Watt complete all as specified and directed.
9
-
-
S&F 09W/10W Bulk head luminiares including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
5
-
-
S&F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50HZ, RPM 1200, Copper winding of sweep 300mm, with 2 years warranty complete all as specified and directed.
2
-
-
S & F of sheet metal enclosure distribution boards double door three phase 415 Volts 12 Ways Vertical TPN DB For Comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising the following (a) MCCB Four pole 100 Amps AC 415 Volts 25 KA - 01 Nos as incoming and 12 Nos MCB SPN 40 Amps, C Series as outgoing complete all as specified and directed.
1
-
-
Supply and fixing of MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
1
-
-
S & F of MCB SPN, 240volt, 40 to 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
10
-
-
M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FR-LS-H ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 4 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surface including taking down old unserviceable submain wiring and making good disturbed surface complete all as specified and directed.
200
-
-
S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed.
9
-
-
Supply & Fixing RCBO, single pole and neutral (SPN) 30mA, 240V, 32 Amp complete all as specified and directed.
9
-
-
S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C’ series, complete all as specified and directed.
18
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
4
-
-
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed. Note: -Punned thickness only shall be measured and paid.
7.7
-
-
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed.
0.76
-
-
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed.
115
-
-
Supply and fixing of GI Tubing medium grade of 40mm nominal bore of pipe in trenches/under roads/ under culverts/under paths under floor on walls with pole in new position with screwed, sockets joints together with all tube fittings complete all as specified and directed.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements