Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Oct 2024
Closing Date19 Nov 2024
Tender Amount₹ 54,00,000
Costs
EMD
₹ 1,06,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Installation Of 100 Kva Sub Station Alongwith Ht/lt Electric Supply At Baraf Post
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679143_1Bid Award Id
ViewTender No
CWEK/TOKEN-62/874 EWS/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 33000 volts, Earthed grade cross sectional area 95 sq mm, 3 core, ISI marked complete all as specified and as directed and directed by Engr-in-Charge.
50
-
-
M & L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts. Earthed grade cross sectional area 95 sq mm, 3 core, ISI marked complete all as specified and as directed and directed by Engr-in-Charge.
50
-
-
Material and labour for cable jointing kit for 33KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge
2
-
-
Material and labour for cable jointing kit for 11KV(Earthed grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply, installation, testing and commissioning of 33 KV three phase four wire out door oil cooled type Current Transformer Potential Transformer Combination of ratio 33 KV/1t3/110 V/rt3/110V/rt3, Class 0.5-3, Burden and other paramenters as specified by Engineer in charge as per site suitability. The CT-PT installed on existing two pole structure at site complete, all as specified and as directed
1
-
-
Supply, installation, testing and commissioning of 11 KV three phase four wire out door oil cooled type Current Transformer Potential Transformer Combination of ratio 11 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden and other paramenters as specified by Engineer in charge as per site suitability. The CT-PT installed on existing two pole structure at site complete, all as specified and as directed
1
-
-
Supply, Installation, Testing and Commissioning of AC 33KV Trivector meter in Poly Carbonate Body, Accuracy Class 0.5s as per IS-14697 and ISI-5959 for communication, DLMS compliance with feature of Non Programmable CT at the site. Backlit LCD Display, (Measures kWH, KVAH, V, 1, kW, 6 months history of Energy, Load Survey, TOD, Tamper detection & logging, power On/Off Events, Having Galvancially Isolated Optical & RS232 Port (As per IS1-5959) suitable to measure instantaneous parameters of Rating-/1A with display in absence of power. Default PT ratio: 33KV/110V & CTR including necessary connection from CT PT to meter alongwith additional accerioes required all specified and directed
1
-
-
Supply, Installation, Testing and Commissioning of AC 11KV Trivector meter in Poly Carbonate Body, Accuracy Class 0.5s as per IS-14697 and ISI-5959 for communication, DLMS compliance with feature of Non Programmable CT at the site. Backlit LCD Display, (Measures kWH, KVAH, V, 1, kW, 6 months history of Energy, Load Survey, TOD, Tamper detection & logging, power On/Off Events, Having Galvancially Isolated Optical & RS232 Port (As per IS1-5959) suitable to measure instantaneous parameters of Rating-/1A with display in absence of power. Default PT ratio: 11KV/110V & CTR: ,including necessary connection from CT PT to meter alongwith additional accerioes required all specified and directed.
Note for items No 10&11:- Meter shall be fitted in meter box supplied & fixed under BOQ item No 12
1
-
-
Supply and Installation of IP 68 rated electric meter cover, heavy duty, made of sheet metal, corrossion proof, having hard break proof glass for meter reading, with rails for MCB mountings, for ibid electric meter, including all necessary fittings and material for installation of the cover and the meter into the cover complete, all as specified and as directed by Engr-in-Charge.
2
-
-
Excavation in trenches n. exc. 1.5m wide and n. exc 1.5m in depth for foundation laying of pole, stay assembly and laying of LT cable as in any type of soil and getting out complete all as specified and directed
218.9
-
-
-Ditto- all as item No 13 Above but depth beyound 1.5m deep, for poles.
29.7
-
-
Returning filling in including spreading levelling, watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed.
139.66
-
-
Removal of excavated material to a distance not exe 50m and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed.
108.94
-
-
Supply and filling dry river sand in trenches including spreading for cushioning of LT UG cablec and punning down complete all as speified and directed by Engr-in-charge.
Note : Punned down thickness shall be measured and paid
52.49
-
-
Material and labour for kiln burnt Sub class 'B' bricks laid dry, flat, width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed
5.91
-
-
M & L for cement concrete for foundation fillings and mass conctere type D2 1:4:8 using 40 mm graded stone aggregate complete all as specified and directed.
5
-
-
M & L for cement concrete for foundation fillings, stay assembly and mass conctere 1:3:6 type C2 using 40 mm graded stone aggregate complete all as specified and directed.
21.35
-
-
M/L for cement concrete 1:2:4 type B-I (20 mm graded stone aggregerate) as in coping as specified and directed by Engr-in-Charge
Note:- Unit rate shall be inclusive of from work.
2.98
-
-
Supply & fix cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface,complete all as specified and directed by Engr-in-Charge.
7.5
-
-
Supply and Fixing of ACSR conductor of 3 of 6/1 x 2.59 mm, and 1 of 6/1 x 2.11 mm squirrel size (as reqd on site) including stretching, fixing and binding to insulator on OH LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified and directed by Engr-in-Charge
8.7
-
-
Supply and Fixing for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 (LT) volts grade complete all as specified and directed
220
-
-
Supply and Fixing of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified and directed.
20
-
-
Supply and erect steel tubular swaged poles ISI marked complete with cast iron base plate, final taper plug, bolts, nuts and screw drilling of holes for continuous Gl earth wire as specified type 410-SP-31 (09 mtrs longi including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer after preparation of surfaces. complete, with one earthing after every three poles(on the third poles), all as specified and directed by Engineer in Charge. Note:- (Excavation and PCC shall be measured and paid separately)
55
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core, all as specified and directed by Engr-in- Charge.
90
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, all as specified and directed by Engr-in- Charge.
105
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core, all as specified and directed by Engr-in- Charge.
270
-
-
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core, all as specified and directed by Engr-in-Charge.
220
-
-
M & L, earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground levell with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by Gl light grade pipe 15mm bore including Gl medium grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-1 and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle. made to shape, common salt, charcoal and testing on completion, all as specified and directed
12
-
-
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), Outdoor LT Panel, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars of 300 Amps rating, installed on polymer insulators. The bus bars shall be covered with colour coded (depending on the phase) heat shrink sleeve. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally and internally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with two layers of Sheet Metal Cover (should have one set of doors on inside and one set of doors outside), capable of withstanding snow and rain at installation site with maintainence proof design, with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) lock with 2 keys, having one chamber with door for each MCCB, having two empty chambers for future use, internal wiring 2.5 Sqmm with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size incl the provision of space to accommodate the under mentioned items. The cable coming in and out of the Panel will be laid in specially made PCC/ Brick Masonry Trenches/ Ducts of 30cm x 30 cm with sand cushioning till top and RCC/ Cast Iron lid cover for the trenches. The scope of work includes the following:-
(a) Incoming
(i) On Load Panel Mounted 200A Changeover, 2 input and 1 output-01 Nos
2
-
-
(ii) MCCB 4 pole, 415 volts AC grade, 160 Amps rating and 36 KA rupturing capacity complete 01 No
(iii) Two empty space for future MCCB connection in input (before Changeover, for generator) Short with bus bar. The space shall be closed with a bolted door.
(b) Outgoing
(i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 26 KA rupturing capacity complete 02 Nos
(ii) MCCB 4 Pole 63 Amps rating and 16 KA rupturing capacity -02 Nos (one Standby)
(c) Voltmeter set and Three Phase Digital Panel Ammeter with three displays to display all phases symulteneously 02 Nos
(d) Indicator lamp RYGB Make Havells -01 set (e) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road/ground/floor level.
-
-
-
(f) LCD Multifuentional panel type energy meter, with tamper detection, output for data saving and data logging Model Secure Elite 440 series or equivalent in L&T/HPL-01 Nos (g) Current Transformers As required (h) Schematic Drawing Plate, Rivetted to the panel - 01 No
Note:
(i) All out going feeders shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
-
-
-
M & L for earthing complete with galvanised steel carth plate electrode 60x60cmx 6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68) 8 mesh per liner inch, 80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/transformer neutral/body/LT panel etc.and testing on completeion complete all as specified and directed
16
-
-
M & L for Construction of shed size of 3 x 3x3 mtr for suitable for 100 KVA Transformer including steps, plinth protection, cable duct complete all as specified and directed by Engr-in-Charge.
Drg No CESZ/TD-1110/2011 Sheet 1/2 & 2/2 dated 01 Dec 2011.
3
-
-
Supplying and install on load change over switch 415 V in sheet metal enclosures 4 pole of capacity 160 Amp fix on wall including necessary fittings, complete all as specified and directed by Engr-in-Charge
2
-
-
S & F, LT End termination heat shrinkable type Joint 1100 V Grade suitable for XLPE cable of normal size 4 Core 10 to 120 Sqmm complete all as directed