Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681431_1Tender No
GEJC-72/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and laying in replacement well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent / abutting each other in trenches over the cable for protection complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Supplying and laying in trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level complete all as specified and as directed.
180
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
1200
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 2 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
900
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
800
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
500
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
200
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
1200
-
-
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 4 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
1200
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 120 Sqmm complete all as specified and as directed.
40
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 70 / 95 Sqmm complete all as specified and as directed.
40
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 50 Sqmm complete all as specified and as directed.
50
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 35 Sqmm complete all as specified and as directed.
70
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 25 Sqmm complete all as specified and as directed.
100
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 150/180 Sqmm complete all as specified and as directed.
30
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 250 Sqmm complete all as specified and as directed.
30
-
-
Supply and fixing in replacement unserviceable copper lugs / thimble of size 400 Sqmm complete all as specified and as directed.
30
-
-
Taking down unserviceable street / security light fitting of any type from the pole / building after disconnecting electric connection carefully complete all as specified and as directed.
335
-
-
Supply and fixing in replacement LED street light fitting 35 / 45 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
70
-
-
Supply and fixing in replacement LED street light fitting 60 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
70
-
-
Supply and fixing in replacement LED street light fitting 90 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
50
-
-
Supply and fixing in replacement LED street light fitting 120 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
50
-
-
Supply and fixing in replacement LED flood light 120 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
40
-
-
Supply and fixing in replacement LED flood light 210 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
35
-
-
Supply and fixing and fabrication bracket made out of galvanized iron tubing suitable for 45 / 60 / 90 watt LED light grade upto 1.2 metre length, bend to shape suitable for security light fitting with necessary mild steel clamps with one coat of red oxide primer and two coats of aluminium paint including nut, bolt, washers, clamps etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
20
-
-
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semiconducting compound extruded XLPE insulated, insulation screen of extruded semiconducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 35 Sqmm + 1 x 25 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT distribution system complete all as specified and as directed.
900
-
-
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semiconducting compound extruded XLPE insulated, insulation screen of extruded semiconducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 50 Sqmm + 1 x 35 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT distribution system complete all as specified and as directed.
900
-
-
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semiconducting compound extruded XLPE insulated, insulation screen of extruded semiconducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 70 Sqmm + 1 x 50 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT distribution system complete all as specified and as directed.
900
-
-
Supply and fixing in replacement of 1100 Volt Arial bunched cable having three phase conductor of multistranded compacted circular aluminium conductor screen of extruded semiconducting compound extruded XLPE insulated, insulation screen of extruded semiconducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS : 7098 Part-II of size 3 x 95 Sqmm + 1 x 70 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT distribution system complete all as specified and as directed.
900
-
-
Labour for taking out all incoming / outgoing electric connection from LT panel / starter / motor / voltage stabilizer carefully for repair to cable / rectification the fault and reconnecting in position after repair and preparation the cable and fixing complete with nut, bolts, washers for cable size 25 to 120 Sqmm including preparation of 3.5/4 core cable, 4 wire each alongwith connected items like thimble, insulation tape and will be considerable in this job complete all as specified and as directed.
15
-
-
Material and labour for LT panel box size (1.0 X 1.0 X 0.6 mm) having thickness of 3.15mm and inner shell made out of 2mm thick mild steel sheet and mild steel angle section 50 x 50 x 6 mm mounted on PCC (1:2:4) type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable / openable by keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS : 8623 / 93 complete all as specified and as directed.
(a) Incoming: - (i) MCCB, 630 Amps, 4 Pole, 415 V, 35 KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
(b) Outgoing: - (i) MCCB, 250 Amps, 4 Pole, 415 V, 10 KA - 02 Each (ii) MCCB, 100 Amps, 4 Pole, 10 KA - 02 No.
(c) Digital Ammeter 0-400 A of size 96 Sqmm with selector switch - 01 No.
(d) Digital Volt meter 0-500 V of size 96 Sqmm with selector switch - 01 No.
(e) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming including back up protection by 2 Amp MCB RYB with holder - 01 set of three.
(f) CT coils of suitable ratio - 01 Set.
5
-
-
Material and labour for replacement of old burnt out aluminium bus bar and connected link bar with proper colour coding with insulation tape of current rating 630/400 Amps including replacement of old rusted nut and bolts, washers complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement unserviceable indicators LED set of three pieces as per existing size and sample complete all as specified and as directed by Engineer-in-Charge.
4
-
-
Supply and fixing in replacement Ampere meter analog type 0-400 Amp CT with suitable set of size 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
4
-
-
Supply and fixing in replacement Volt meter analog type 0-500 Volt 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
100
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 150 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
80
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 185 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
100
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 240 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
60
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 400 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
60
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 70 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
150
-
-
Description all as per Ser item No. 39.00 here-in-before but cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
100
-
-
Material and labour in replacement of galvanised iron pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and as directed.
20
-
-
Material and labour in replacement of galvanised iron pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and as directed.
24
-
-
Material and labour for replacement of MCCB 3 pole, current rating 100 Amp, thermal setting adjustable type 70%-100% rapturing capacity 16 kA at 415 V, 50 Hz complete all as specified and as directed.
2
-
-
Material and labour for replacement of MCCB 3 pole, current rating 125 Amp, thermal setting adjustable 70%-100% rapturing capacity 16 kA at 415 V, 50 Hz complete all as specified and as directed.
2
-
-
Material and labour for replacement of MCCB 4 pole, current rating 160 Amp, thermal setting adjustable 70%-100% rapturing capacity 36 kA at 415 V, 50 Hz complete all as specified and as directed.
2
-
-
Material and labour for replacement of MCCB 4 pole, current rating 200 Amp, thermal setting adjustable 70%-100% rapturing capacity 36 kA at 415 V, 50 Hz complete all as specified and as directed.
2
-
-
Material and labour for replacement of MCCB 4 pole, current rating 250 Amp, thermal setting adjustable 70%-100% rapturing capacity 36 kA at 415 V, 50 Hz complete all as specified and as directed.
2
-
-
Material and labour for replacement of MCCB 4 pole, current rating 400 Amp, thermal setting adjustable 70%-100% rapturing capacity 36 kA at 415 V, 50 Hz complete all as specified and as directed.
3
-
-
Material and labour for replacement of MCCB 4 pole, current rating 630 Amp, thermal setting adjustable 70%-100% rapturing capacity 50 kA at 415 V, 50 Hz complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 100 Amp, 415 volts 3 phase, four pole complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 200 Amp, 415 volts 3 phase, four pole complete all as specified and as directed.
2
-
-
Supply and fixing in repair onload change over switch with sheet steel enclosure 415 V, 4 pole, 315 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Labour charges for repair / maint to old / unserviceable LED security / street / flood light / High mast light of any capacity including taking down existing fitting from pole / building for replacement of unserviceable driver, cable terminal block and connection wire and refixing the same in position after repair including testing complete all as specified and as directed by Engineer-in-Charge.
Notes: - (i) Spares shall be measured and paid separately under respective item.
(ii) Sufficient Electrician and Helper shall be deputed daily to concerned subdivision during office hours to ascertain the repairs to be carried out for lights under his AOR.
(iii) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as SUPPLY ONLY.
(iv) Necessary arrangements for carrying out repairs shall be undertaken by the contractor.
79
-
-
Supply and fixing in replacement of electronic driver of capacity 45 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
30
-
-
Supply and fixing in replacement of electronic driver of capacity 60 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
20
-
-
Supply and fixing in replacement of electronic driver of capacity 90 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
15
-
-
Supply and fixing in replacement of electronic driver of capacity 120 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement of electronic driver of capacity 200 watt of existing make for LED flood light fitting complete all as specified and as directed by Engineer-in-Charge.
4
-
-
Dismantling / taking up of LT unserviceable pre-stressed concrete / steel poles of any size and shape and including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed by the Engineer-in-Charge.
Note: - Earth work for taking out of poles shall be measured and paid separately under relevant item of this Schedule.
9
-
-
Material and labour for steel tubular swagged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) including two coats of silver paint over one coat of red oxide paint complete with strip of black and white strips having 30 cm of width upto 1.5 metre height from top of coping including taking out old unserviceable PCC pole complete all as specified and as directed by Engineer-in-Charge.
Note: - Excavation, foundation concrete, preservative treatment etc will be measured and paid separately.
9
-
-
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate as in foundation of electric poles, struts, PCC blocks etc including necessary form work complete all as specified and as directed.
0.6
-
-
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of assembly, bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement, struts, PCC blocks etc including necessary form work complete all as specified and as directed.
8
-
-
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as directed.
1
-
-
Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from the site(s) complete all as specified and as directed.
4
-
-
Labour for rectification of fault related ACSR jumpers, insulators binding wire by removing old one and replacement with new wire binding or rejumber as required etc. complete all as specified and as directed.
Note: - Material shall be measured and paid separately under supply only.
20
-
-
Supply and fixing in replacement of ACSR conductor of any size and type from overhead HT / LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT / HT poles complete all as specified and as directed.
1
-
-
Fixing only by re-straining, tightening of ACSR conductors of any size / type on HT / LT poles including necessary new aluminium binding wire for fixing with insulator / PVC sleeves for jumper etc as required complete all as specified and as directed.
Note: - Serviceable ACSR conductors shall be obtained from Ser item No. 69 here-in-before.
2
-
-
Material and labour in replacement of galvanised steel wire 4.0 mm dia for continuous earth wire and cradles hexagonal / rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire complete all as specified and as directed.
0.5
-
-
Dismantling cross arms of mild steel channel or angle sections etc. and keeping serviceable materials in safe custody for re-use and / or unserviceable materials removing from the site (s) complete all as specified and as directed.
3
-
-
Material and labour in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. mild steel channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete all as specified and as directed.
2
-
-
Fixing only serviceable cross arm, mild steel channel, angle section obtained from Ser item No 75.00 here-in-before as ordered and inclusive of one coat of aluminium paint including preparation of old steel surfaces complete all as specified and as directed.
1
-
-
Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and / or unserviceable materials removing from the site complete all as specified and as directed.
238
-
-
Material and labour in replacement of insulator pin type, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
60
-
-
Material and labour in replacement of insulator pin type, polymer composit material including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
58
-
-
Fixing only serviceable pin type porcelain, vitreous, (white / brown / green) insulator for 1100 volts grade of any type obtained from Ser item No 79.00 here-in-before complete all as specified and as directed.
40
-
-
Material and labour in replacement of insulator shackle type, porcelain, vitreous, white, brown or green shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts 12 mm dia and nuts with or without a pair of straps in size 31 x 3 mm as indicated size height 75 mm and dia 90 mm, for working pressure 1100 volts complete all as specified and as directed.
40
-
-
Fixing only serviceable shackle type porcelain, vitreous (white / brown / green) insulator of any size and shape for 1100 Volts grade obtained from Ser item No 81.00 here-in-before complete all as specified and as directed.
40
-
-
Supply and fixing PVC flat fibre separator for LT line 1100 volt overhead conductor 3/4/5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and as directed.
100
-
-
Supply and fixing SMC pole mounted box of size 10" x 8" x 4" with hinged door including clamp, nuts, bolts and washers and including taking down of old unserviceable junction boxes complete all as specified and as directed. The Box includes: -
(a) MCB single pole 10 Amp, 10 KA 'C' series mounted on din rail - 1 No.
(b) Connector block suitable for 3 phase, 4 wire minimum 16 Sqmm cable - 1 No.
120
-
-
Material and labour in replacement of PVC insulated and sheathed cable of size 1.5 Sqmm 3 core copper conductor multistranded 1100 volt grade 230 volts running through PVC conduit of dia 20 mm with strip clamping on poles at 3 places complete all as specified and as directed by Engineer-in-Charge.
1400
-
-
Material and labour for shifting heavy items / excavating / cleaning areas / clearing site by providing crane / hydra / excavators / tractors / trolley etc as required at site complete all as specified and as directed.
79
-
-
Material and labour for surface cleaning of steel tubular poles LT 9 metres long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black and white strips alternatively 30cm each from coping upto 1.5 metre height starting with black strip using synthetic enamel paint including repairing and painting on coping with cement based white paint complete all as specified and as directed.
Notes: - (i) The quoted rates shall include marking of numbers on each LT pole as per directions of Engineer-in-Charge.
(ii) The quoted rates shall include the repairing of coping with cement / PCC.
120
-
-
Material and labour for cement based white / off white paint for PCC pole 9 metre long, top to bottom and above 1.5 metre from ground level including black and white strips alternatively 30cm each from coping upto 1.5 metre height starting with black strip using synthetic enamel paint including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc including repairing and painting on coping with cement based white paint complete all as specified and as directed.
Notes: - (i) The quoted rates shall include marking of numbers on each LT pole as per directions of Engineer-in-Charge.
(ii) The quoted rates shall include the repairing of coping with cement / PCC.
150
-
-
Supply and fixing in replacement indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 400 Sqmm complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Supply and fixing in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
-
-
Supply and fixing in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
-
-
Supply and fixing in replacement straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-400 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%