Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date7 Mar 2025
Closing Date29 Mar 2025
Tender Amount₹ 43,24,000
Costs
EMD
₹ 86,480Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_700651_1Tender No
GE 861 EWS-87/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolition of brick or stone/boulders masonry, built in cement mortar complete all as specified and directed by Engineer-in-Charge.
46.4
-
-
... More
Demolition of reinforced cement concrete of any description (reinforcement cut as reqduired to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
4.5
-
-
... More
Taking down chowkhat or frame with shutters (without taking shutter from the frame) exceeding 1.5 sqm and not exceeding 4.00 sqm each complete all as specified and directed by Engineer-in-Charge.
14
-
-
... More
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) n. exe 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge.
30
-
-
... More
M&L for cement concrete type C-2, (1:3:6) (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
22
-
-
... More
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
45.6
-
-
... More
M&L for random rubble masonry walling, uncoursed, well bonded, bedded and solidly hearted, built in cm (1:6) but except stones (retrieved from demolition of item no 04 here in before) complete all as specified and directed.
12
-
-
... More
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
560
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:6 finishing on brick or concrete surfaces other than fair faces finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
530
-
-
... More
M&L for 2nd class hard wood, plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge.
1.2
-
-
... More
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns etc. complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
M&L for RCC (nominal mix) 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
... More
M&L for form work to soffits of suspended slabs such as roof slabs, floor slab, landings and similar work not exc 200 mm thick (horizontal or sloping) platforms etc. complete all as specified and directed by Engineer-in-Charge.
9.6
-
-
... More
M&L for form work to edge of concrete, flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, slabs etc horizontal or sloping and similar works exc 10cm but n exc 20 cm wide complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
M&L for Mild Steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
M&L for Mild Steel TMT bars 5 mm dia and over upto and including 10 mm d cut to length bent ta in stirrups , spacer and binders etc. complete all as specified and directed by Engineer-in-Charge.
120
-
-
... More
Supply and fixing 2nd class hard wood 35 mm thick panelled shutters (any number of panels ) with panels of timber flat on both sides (feather edged) of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed by Engineer-in-Charge.
27.4
-
-
... More
Supply and fixed 35mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc (internal sash bars) edges of framing plane, chamfered or rounded fitted and mitred beads for securing glass etc size of members as specified in SSR Part-I Section 8 clause 8.24(a) (kail) complete all as specified and directed by Engineer-in-Charge.
23.4
-
-
... More
Supply and fixed 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc (internal sash bars) edges of framing plane, chamfered or rounded fitted and mitred beads for securing glass etc size of members as specified in SSR Part-I Section 8 clause 8.24(a) (kail) complete all as specified and directed by Engineer-in-Charge.
47
-
-
... More
Taking down of shutters and refixing the same in same opening n exc 1.0 sqm each complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Taking down of shutters and refixing the same in same opening exc 1.0 sqm but n exc 2.0 each complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed by Engineer-in-Charge.
14
-
-
... More
S&F aluminium anodised barrel tower bolts extruded section of size 200 mm complete all as specified and directed by Engineer-in-Charge.
36
-
-
... More
S&F aluminium anodised barrel tower bolts extruded section of size 150 mm long , complete all as specified and directed by Engineer-in-Charge.
72
-
-
... More
S&F aluminium handle extruded febricated type anodised of size 150 mm complete all as specified and directed by Engineer-in-Charge.
56
-
-
... More
S&F100mm mild steel pressed handles oval type stove enamelled black complete all as specified and directed by Engineer-in-Charge.
48
-
-
... More
S&F for butt hinges 100mm medium weight stainless steel complete all as specified and directed by Engineer-in-Charge.
84
-
-
... More
S&F for butt hinges 75 mm medium weight stainless steel complete all as specified and directed by Engineer-in-Charge.
144
-
-
... More
S&F MS helical door spring including roller & roller plate complete 300 mm size complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
14
-
-
... More
S&F in repairs 20 mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engineer-in-Charge.
35
-
-
... More
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane including hacking out old glass panes complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F vitrified ceramic dark shade coloured tiles 10mm thick (square/rectangular) polished, area of each tiles n. exc 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
140
-
-
... More
M&L for vitrified ceramic dark shade coloured 10 mm tiles in vertical surfaces n. exe 0.36 Sqm, over and including 10mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match for wall complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
M&L for glazed ceramic tiles in vertical surfaces 350 x250x7/450x350x7 mm thick , thick on vertical surfaces of walls such as skirting dado etc and jointed in neat cement slurry and pointed in white cement to match laid over and including cement screed bed 10mm thick in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
350
-
-
... More
M&L for kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match th shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
112
-
-
... More
Description all as per item No 40 here-in-above but on vertical surfaces of walls /skirting/dado etc. complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
M&L in repairs for 20mm thick pre-polished granite slabs, machine cut, in vertical/horizontal surfaces with bolting and araldite laid over and including cement plaster 15mm thick in cement mortar 1:4 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of the granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
M&L for cement concrete type C-1, 1:3:6 (using 20mm graded crushed stone aggregate), 50mm thick as in plinth protections complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
270
-
-
... More
S&F anodised aluminium snap grid frame work for false ceiling size of grid 605x605mm frame complete all as specified and directed by Engineer-in-Charge.
270
-
-
... More
S&F for 10 mm thick PVC insulation panels with EPS stuck to 1 mm plain PVC sheet suitably placed in false ceiling grid made of aluminium & GI/MS as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
270
-
-
... More
Dismantling water storage tanks of any description, exc 500 litres & n exc 1000 ltr capacity and removing from site complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F for Rotational moulded polyethylene 1000 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20 mm ball valve high prressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F in repairs 15 mm bore fancy type CP bib taps cast copper alloy with crutch or butterfly handle, screwed down for iron pipe complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
Taking up or down 15mm dia GI Tubing and connections including cleaning for refixing or removal to store complete all as specified.
40
-
-
... More
S&F 15 mm bore GI tubing medium grade galvanised with all fittings concealed and fixed complete to walls & floors etc. complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
S&F 20 mm bore GI tubing medium grade galvanised with all fittings concealed and fixed complete to walls & floors etc. complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L in repairs for weather boarding in 2nd class hardwood clean sawn, plain, 20 mm thick or feather edges, 15 mm to 20 mm thick and fixed with 30 mm laps joints complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L for 2nd Class hard wood eaves, wrought on both sides, plain, 20-25mm thick and fixed with 30mm laps, complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Dismantling timber scantling 40 sq cm and over in section, in any position complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F timber in framed work in second class hard wood clean sawn as in scantling etc. complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F in repairs 20 mm bore gun metal globe or gate valve with iron wheel head screwed head both for iron pipe & fixed complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by Engineer-in-Charge.
540
-
-
... More
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
500
-
-
... More
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheets 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge etc fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
30
-
-
... More
S&F fibre glass translucent corrugated sheeting with two corrugation side lap fixed with L type or J type cranked hook bolts complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L for preparation of new surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
560
-
-
... More
M&L for applying 3 mm thick wall care putty on wall including preparation new surfaces plastered or unplastered surfaces , complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
M&L for preparing plastered new surfaces of walls and applying three coats of white wash on walls complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
M&L for preparation of old surfaces of walls by complete removal of existing treatment and applying two coats of cement based paint over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
208
-
-
... More
M&L for two coats of synthetic enamel paint on new wooden surfaces over a coat of pink primer including preparation of surfaces, over 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
210
-
-
... More
Description all as per the description of item no 67 above here in above but one coat on old surfaces without primer complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
M&L for two coats of synthetic enamel paint over one coat of pink primer on old wooden surfaces including complete removal of existing treatment and preparation of surfaces over 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate ) as in sub base for receiving floor finishes etc. complete all as specified and directed by Engineer-in-Charge.
76
-
-
... More
M&L for chequered cement concrete tiles glossy finished 25cm x25cmx22mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
166
-
-
... More
Hacking out old broken glass any thickness, size quality from wooden or steel frames glazed with old putty or fixed with beads complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
S&F aluminium handle extruded febricated type anodised of size 100 mm complete all as specified and directed by Engineer-in-Charge.
24
-
-
... More
S&F mild steel framed work such as grills, grating etc with guard bars, feamed guard bars, hold fasts,, railing, framed work of water tanks and similar work confirming to Fe-290 gde-E165 complete all as specified and directed by Engineer-in-Charge.
120
-
-
... More
M&L for 100 mm thick PCC 1:3:6, type C-2 and in sub base using 20 mm graded aggregate crushed stone complete all as specified and directed by Engineer-in-Charge.
90
-
-
... More
M&L for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded crushed stone aggregate as in floor to receive floor finishes etc. complete all as specified and directed by Engineer-in-Charge.
160
-
-
... More
M&L for coloured Non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the floor laid over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
160
-
-
... More
M&L for two coats of synthetic enamel paint on NEW STEEL surfaces over coat of red-oxide primer including preparation of surfaces, over 10cm width or girth including preparing roof painting complete all as specified and directed.
6
-
-
... More
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
M&L cement concrete type C-2, 1:3:6 (40mm graded crushed stone aggregate), 75mm thick as in plinth protections complete all as specified and directed by Engineer-in-Charge.
30
-
-
... More
M&L in repairs for weather boarding in 2nd class hardwood clean sawn, plain, 20 mm thick or feather edges, 15 mm to 20 mm thick and fixed with 30 mm laps joints complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
M&L for PCC 1:2:4 type B-2, (using 40mm graded aggregate) as in surface channel and drains complete all as specified and directed by Engineer-in-Charge.
0.45
-
-
... More
M&L for PCC 1:2:4 type B-1, (using 20mm graded aggregate) as in coping, plinth courses, parapets and railings etc including necessary form work complete all as specified and directed by Engineer-in-Charge.
0.4
-
-
... More
S&F in repairs plain mild steel wire, 4.0 mm dia galvanised class 3 in detached work such as arrangement for mosquito nets fixing including straining bolts, hooks, eyes etc. complete all as specified and directed by Engineer-in-Charge.
0.5
-
-
... More
M&L for preparation of old surfaces of walls by complete removal of existing treatment and applying two coat of oil bound distemper over a coat of primer with 3 mm wall thick wall care putty finish complete all as specified and as directed by Engineer-in-Charge.
60
-
-
... More
M&L for applying 3 mm thick wall care putty on new plastered wall surfaces and applying two coats of oil bound distemper over chalk whiting, preparatory to distempering complete all as specified and directed by Engineer-in-Charge.
130
-
-
... More
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc. complete all as specified and directed by Engineer-in-Charge.
145
-
-
... More
M&L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in PVC casing & capping and including pipe hooks , elbows, junction covers and junction boxes , after fixing or cutting on wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep ,suitable length and thickness for mounting, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly fixed on wall or grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
86
-
-
... More
Description as per srl item No-88 here in above but for one 5A socket outlet on the same board controlled by one switch.
8
-
-
... More
Description as per srl item No-88 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
38
-
-
... More
Description all as per srl item No 88 above but for 3 pin socket outlet 15 Amps independent board with 2.5 Sqmm.
13
-
-
... More
S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FR/FR/FRLS stranded copper conductor drawn in surface PVC conduit /casing capping of size 20mm “medium quality” conduit including 4.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after fixing or chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. (Note : PVC cable and PVC conduit shall be ISI marked)
120
-
-
... More
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer-in-Charge.
92
-
-
... More
S&F for Switch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
13
-
-
... More
S&F for Switch Socket combination 2 in 1, 6 Amps flush type, 230 volts complete all as specified and directed by Engineer-in-Charge.
38
-
-
... More
S&F socket outlet 3 pin, 5 Amp, flush type complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
S&F fan regulator Electronic type complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
S&F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer-in-Charge.
52
-
-
... More
S&F LED lights fitting 1x20W, 230V, AC decorative box type with drive, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
44
-
-
... More
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt( White/ Warm White) , 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F LED lights fitting 1x10W, bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Taking down exhaust fan of any size after disconnecting the wire from existing ceiling rose and deposited to MES Store (AGE E/M Sub Divn) and supply & fix exhaust fan, steel body, AC single phase 230/240 volts heavy duty of size 300mm sweep with blades, frame, louvers and all fixing arrangements complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
S&F sheet metal enclosure MCB distribution board, double door with IP -43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link make . Standatd/ Havells/Legrand fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix in replacement MCB SPN, 240 volts any rating from 40-63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
M&L for MCB single pole 240 volts 5 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), disconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed by Engineer-in-Charge.
24
-
-
... More
Supply , laying and fixing testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade of size 35 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
70
-
-
... More
Supply , laying and fixing testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade of size 16 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
35
-
-
... More
Excavation in trenches in n. exc 1.5 mtr vide and 1.5 mtr in depth and getting out in soft/loose soil for laying of U/G cable complete all as specified and directed by Engineer-in-Charge.
12.76
-
-
... More
Returning filling in incl spreading levelling watering and well ramming in layers in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
5.23
-
-
... More
Removing of surplus excavated material to a distance n. exc 50 mtr and deposing where directed at a level n.exc 1.5 mtr from the starting point complete all as specified and directed by Engineer-in-Charge.
7.53
-
-
... More
M&L for sand cushioning in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
5.1
-
-
... More
Supply & laying of bricks common burnt clay locally available best quality laying in trenches across the cable for protection complete all as specified and directed by Engineer-in-Charge.
0.79
-
-
... More
S&F in replacement 40mm bore GI water tubing medium grade (ISI marked) laid in trenches including fittings as required as site and including jointing complete all as specified and directed by Engineer-in-Charge.
24
-
-
... More
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying SPN 40-63 Amps capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amps in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supplying and fixing in replacement installing, commissioning testing in repair LT cubical feeder pillar box out door kiosk type made out of CRCA sheet 3.15mm, 3 phase 4 wire 50 C/S AC with aluminium bus bar of 250 Amps rating fixed on insulators for incoming & outgoing taping complete double door type with locking arrangement fixing on PCC platform with suitable nuts, bolts dully painted with two coats of synthetic enamelled paint over a coat of red oxide primer, cable for service connection complete all as specified and directed by Engineer-in-Charge comprising of the following switchgear:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160 Amps with breaking capacity 35 KA - 01 No OUTGOING :- (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 25 KA - 02 No. (c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 25 KA - 01 No (d) MCB 40 Amps SPN C curve - 02 Nos (e) Voltmeter electronic, digital type, with selector switch 0 - 500 volts, AC, 50 Hz - 1 No. (f) Ammeter electronic, digital type, 0 - 250 amps, AC, 50 Hz - 1 No. (g) Current transformer 200 / 5 amps rating, AC, 50 Hz - 3 Nos. (h) Phase indication lamps - 3 Nos. Make of MCCB : Legrand/Standard/Havells
1
-
-
... More
Material & labour for earthing complete in replacement with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 2.25mtr deep below normal ground level as earth electrode with top edge of the earth plate not less than 1.5mtr below normal ground level, using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and including testing on completion. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .
(ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department .
3
-
-
... More
Material & labour for earthing complete in replacement with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 2.25mtr deep below normal ground level as earth electrode with top edge of the earth plate not less than 1.50mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and including testing on completion. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .
(ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department .
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%