Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date9 Jan 2021
Closing Date23 Jan 2021
Tender Amount₹ 22,96,035 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Descaling and flushing of cooling coil complete with chemical,brushing to fins bends and clearing complete all as specified and directed for the following :-

-

-

-

... More
60 TR capacity plant

3

-

-

... More
5TR capacity Plant

2

-

-

... More
Repairing /Servicing of cooling tower of AC Plant FRP type by dismantling and taking out the honey comb PVC fills complete and PVC nozzles,descaling the PVC fills by suitable descaling solution including brushing and clearing complete with cleaning solution and water, replacing the defective PVC filling cleaning the nozzles and replacing the defective PVC flange alongwith rubber gasket and rusted bolts, nuts and washers etc cleaning the water sump and XPM wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specified and directed (PVC Fills will be measured and paid separately) for the following:-

-

-

-

... More
60 TR capacity plant

1

-

-

... More
5TR capacity Plant

1

-

-

... More
M & L for repair to existing unserviceable/defective control processing board of New Signal Centre room 60TR including testing & commissioning complete all as specified and as directed

1

-

-

... More
M & L for repair to existing unserviceable/defective control processing board of 1FOD 5TR including testing & commissioning complete all as specified and as directed

1

-

-

... More
M & L for replacement of unserviceable AC power contactor of following capacity from the control panel in AC plants including reconnectiong/testing complete all as specified and as directed.

1

-

-

... More
AC power contactor upto 16 Amps capacity 440 volts, 50 Hz, 3 phase Make:- L&T/BCH/Siemens

10

-

-

... More
AC power contactor 16 Amps up to 32 Amps capacity 440 volts, 50 Hz, 3 phase Make:- L&T/BCH/Siemens

10

-

-

... More
AC power contactor 32 Amps up to 63 Amps capacity 440 volts, 50 Hz, 3 phase Make:- L&T/BCH/Siemens

5

-

-

... More
M & L for replament of old/unserviceable compressor oil SERVO FRIZ F 68 of Indian oil or equivalent in BPCL/HPCL all as specified and as directed.

140

-

-

... More
M & L for replacement of old/unserviceable water thermometer 0 to 30 digree Centigrade including necessary connections/testing complete all as specified and as directed.

12

-

-

... More
M & L for replacement of old/unserviceable analog type electronic timer suitable for 60 TR Cap AC Plant at New Singal Centre room including necessary connections, testing complete all as specified and as directed Make:- L&T/C&S/Seimens/BCH

2

-

-

... More
M & L for replacement of old/unserviceable analog type electronic timer suitable for 5 TR Cap AC Plant at 1FOD including necessary connections, testing complete all as specified and as directed Make:- L&T/C&S/Seimens/BCH

2

-

-

... More
M & L for replacement of old/unserviceable temperature control thermostat +10 degree Centi for cut in/cut off system for any capacity of existing AC Plant including also providing copper wiring with 1.5sqmm 8 core flexible copper wire from AHU to compressor gauge panel including necessary connections, testing complete all as specified and as directed Make:- Honeywell/Ranco/danfoss

4

-

-

... More
Taking out of old/unserviceable butterfly valve from existing pipe line and supply and fixing new butterfly valve of size 80mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works all as directed by Engr-in-Charge. Make:- Advance /Audco/Kirloskar/Neta

2

-

-

... More
Taking out of old/unserviceable butterfly valve from existing pipe line and supply and fixing new butterfly valve of size 50mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works all as directed by Engr-in-Charge. Make:- Advance /Audco/Kirloskar/Neta

2

-

-

... More
Taking out of old/unserviceable butterfly valve from existing pipe line and supply and fixing new butterfly valve of size 100mm, made out of mild steel including necessary modification of existing pipe line and replacement of falnges with new bolts and nuts etc complete replacement of flanges with new bolts and nuts including all connected works all as directed by Engr-in-Charge. Make:- Advance /Audco/Kirloskar/Neta

2

-

-

... More
Supply and fix new syphon connection of half inch size made out of GI pipe with SS coating suitable for fixing of existing pressure gauge including stop cock of suitable size and all minor items and taking down old unserviceble.

6

-

-

... More
M & L for replacement of old/unserviceable anti freeze thermostat for chillar 2 degree to 12 degree and 5 degree to 25 degree to cut off the compressor load including making necessary electical wiring including necessary connections, testing complete all as specified and as directed and taking out old unserviceable Make:- Ranco/Danfoss/Johnson controls

6

-

-

... More
Taking out of side covers of existing cooling tower of 60 TR capacity carefully without any damage to existing items and remove the unserviceble bearing housing assy complete with fan blade and hub etc all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix bearing housing assy complete 2 Nos tapper bearing fixed with extended shaft suitable for cooling tower of 60 TR capacity etc all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fix aluminium hub assy made out of Aluminium casting with fan blade assy suitable for 60 TR capacity cooling tower inlcuding testing etc all as specified and directed by Engr-in-Charge and taking out old unserviceble.

1

-

-

... More
Supply and fix tapper type pulley (fly wheel) of size 60TR cooling tower capacity tower shaft including provision of bolt, nuts and washers all as specified and directed by Engr-in-Charge and taking out old unserviceble.

1

-

-

... More
Dismantling of side cover existing cooling tower carefully with out any damaging to any parts and removing old unserviceable PVC honey comb fills as per existing including replacement of unserviceble PVC Nozzels refixing all side covers of cooling tower after supply and fixing of PVC honey comb fills suitable for cooling tower for following AC Plants:-

-

-

-

... More
60TR Capacity Cooling tower at NSU

1

-

-

... More
5TR Capacity Cooling tower at 1FOD

1

-

-

... More
Supply and fixing of cast iron pot strainer of 80mm/100mm dia including flanges, nut, bolts of suitable size and removing of old unserviceable strainer. Make:- Neta/Loader/Universal

2

-

-

... More
Supply, fixing and welding medium grade GI tubing of following sizes with necessary MS elbows, bends, sockets, flanges etc including removing of old unserviceable pipe lines etc all as directed:-

-

-

-

... More
50mm dia

50

-

-

... More
80 mm dia

50

-

-

... More
Supply and fixing water pressure gauge 0 to 10 Kg 2"/4 dia suitable for condenser / chillar water line including removing of old unserviceable pressure gauge etc all as directed.

10

-

-

... More
Supply and fixing of cooling tower sprinkler made out of aluminium suitable for 60 TR capacity cooling tower including removing old unserviceable sprinkler

1

-

-

... More
Supply, laying, connecting and testing of armoured copper cable of 35 sqmm Single core laying on ground/cable duct/on wall alognwith suitable support on cable duct / on wall all as directed by Engr-in-Charge. Make:- Bajaj/Havelles

120

-

-

... More
Supply and charging of Refrigerant gas R-22 Make:- Refron/Fluoron/Metron

250

-

-

... More
Supply and fix removable type factory made metallic pre filters of 20 micron of standard size with GI frame both side including taking out out unserviceable all as directed by Engr in Charge. Make:- Aerosol/Dyna/Maf/Zonflower

40

-

-

... More
Supply and fix factory made high performance bag filters of 99 micron down to 5 micron of standard size with multiple pockets and self supporting filters bags with MS/GI anodised aluminium frame suitable for central AC Plant including replacement of bolts and nuts na dtaking down unserviceable. Make:- Aerosol/Dyna/Maf/Zonflower

40

-

-

... More
Supply and replacement of condenser safety valve up to 400PSI scaled of any size confirming of ISI including evacuating of refrigerant gas all as specified and as directed.

4

-

-

... More
Supply and fix V-Belt for compressor motor and AHU motor of following sizes:-

-

-

-

... More
V-belt A-27.

3

-

-

... More
V-belt C-95

6

-

-

... More
M & L for cleaning the external surface of equipments/accessories of Central type AC Plant of 60 TR capacity installed at U/G Ops Room and painting with two coats of synthetic enamal paint of existing colour and shade including writing SM/MES No marking direction of flow, set nos completed all as specified, The AC Plant comprising of following :- (a) Compressor motor 40 HP-03 Nos (b) Compressor 30 TR -03 Nos. (c) AHU 30 TE-03 Nos. (d) Cooling towert 60 TR - 02 Nos. (e) Monoblock pump - 02 Nos. (f) Control pannel -02 Nos. (g) Mounting fram - 03 Nos. (h) Pipe line 100 mm (approx 50 RM).

1

-

-

... More
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric suppply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing fo bearings including rewiring with superior quality copper winding wire insulating material, vamishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection completed all as specified and directed. For the following :-

-

-

-

... More
Electric motor 3 phase 40 HP of AC Plant.

2

-

-

... More
Electric motor 3 phase 15 HP of AC Plant.

1

-

-

... More
Electric motor 3 phase 10 HP of AC Plant.

2

-

-

... More
Electric motor 3 phase 5 HP of AC Plant.

2

-

-

... More
Electric motor 3 phase 3 HP of AC Plant.

1

-

-

... More
Description all as per srl item No 37 here-in-before, but including removing of old gland packing, gland bolt and fixing of new gland packing , gland bolt, cleaning of impeller/Replacement of impeller all as directed (Impeller shall be measured and paid for separately) for the following :-

-

-

-

... More
Monoblock pumping set 10 HP.

1

-

-

... More
Monoblock pumping set 7.5 HP.

1

-

-

... More
Monoblock pumping set 5.0 HP.

2

-

-

... More
Repair/Servicing to LT panel board cubical type installed for AC Plant 60 TR capacity installed at New Signal Centre of HQNC consisting of controls for following eqpts chiller pump - 2 Nos condenser pump 2 Nos, CT fan - 1 No, compressor-3 Nos AHU Blower-3 Nos, Heat water pump-02 Nos and Heater Bank-05 Nos. Incoming switch fuse unit to bus bar chamber etc by opening the panel board, cleaning the dust with blower, cleaning the bus bar, replacement of rusted bolts, nuts and washers, checking the wiring complete including inter locking wiring and replacement the bumt wiring, cable lugs, tightening all connections, Including replacing the defective part like power contracts, MCCBs, MCBs indicating lamp push button over load relaty, selector switch, ammeter, voltmeter, timer switch switch fuse units, HRC fuses etc including testing complete all as directed by the Engr-in-Charge (Note : Defective parts like, power contactor, MCCBs, MCBs, push button, overload relays, ammeter, voltmeter, timer switch, HRC fusesmm switch fuses etc will be measured and paid for separately)

1

-

-

... More
Description all as per srl item No 38 above but installed for AC Plant 10 TR capacity all as directed by Engr-in-Charge.

1

-

-

... More
Electric timer switch 240/415 volt 50 HZ for 30 to 60 seconds Make :- GIC/L&T.

2

-

-

... More
Supply only single phase preventor suitable for 415 volt 50H Hz 3 phase as per existing type . Make:- L&T/Siemens.

3

-

-

... More
Supply only Angle valve 1/4"x 1/4" suitable for gas charging/release valve.

3

-

-

... More
Supply only Rotary type switch 3 phase 415 volts 4 pole 2 way 63 Amp Make:- L&T/Siemens.

2

-

-

... More
Supply only Selector switch for volt meter. Make:- AE/Siemens.

2

-

-

... More
MCCB three pole 415 volt 50 Hz 125 Amps with breaking capacity 35 KA type DTH. Make:- L&T/ABB/Schneider/Siemens or equivalent.

3

-

-

... More
MCCB three pole 415 volt 50 Hz 200 Amps with breaking capacity 35 KA type DTH. Make:- L&T/ABB/Schneider/Siemens or equivalent.

1

-

-

... More
3 pole power contactor type ML-1 415/210 volt 50 Hz AC 16 Amps.

3

-

-

... More
Supply, laying in trenches or fixed to wall etc cable PVC insulated mult stranded copper conductor single core cable of size 50sqmm cut to size all as required for connection from DG Set panel to change over and AMF panel including thimble , flexible conduit pipe complete all as specified and directed by Engr-in-Charge. Make: Havell or equivalent of Polycab / Plaza

120

-

-

... More
Repair serving and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric supply removing of pully and fan and opening of both end covers taking out bearings and rotor checking of air gap checking of rotor field winding replacement of bearings greasing of bearings including rewiring with superior quality copper winding wire insulating material, varnishing binding of winding etc complete all as specified and directed for the following:-

-

-

-

... More
Electric motor 3 phase 75 HP of AC Plant

1

-

-

... More
Electric motor 3 phase 15 HP of AC Plant

1

-

-

... More
Electric motor 3 phase 10 HP of AC Plant

2

-

-

... More
Electric motor 3 phase 5HP of AC Plant

1

-

-

... More
Electric motor 3 phase 5HP of AC Plant

2

-

-

... More
Description all as per srl items No 49 here in before, but including removing of old gland packing gland bolt and fixing of new gland packing gland bolt cleaning of impeller/Replacement of impeller all as directed (Impeller shall be mesured and paid for separately for the following:-

-

-

-

... More
Monoblock pumping set 10 HP.

1

-

-

... More
Monoblock pumping set 7.5 HP.

1

-

-

... More
Monoblock pumping set 5.0 HP.

1

-

-

... More
Descaling of condenser after opening of both end cover, circulation of descaling solution forcibly using pump for circulating decalling solution and roding manually using nylon brush of size 1/4,3/8,1/2,5/8 inch descalling rod etc without damaging copper tubling and refixing of side cover using new gasket of rubber incersion sheet of 3mm thick and replacment of rusted nuts bolts etc complete all as specified and directed by Engr-in-Charge for the following:-

-

-

-

... More
47.5 TR cap Condenser

3

-

-

... More
7.5 TR cap Condenser

2

-

-

... More
5 TR cap Condenser

2

-

-

... More
Descaling and flushing of cooling coil complete with chemical brushing to fins, bends and cleaning complete all as specified and directed for the following:-

-

-

-

... More
95 TR Capacity Plant

1

-

-

... More
15 TR Capacity plant

1

-

-

... More
10 TR Capacity plant

1

-

-

... More
Repairig serving of cooling coil tower of AC plat FRP Type by dismating ad taking out the one comb PVC files complete ad PV Nozzels the PVC files by suitable descaling solution icludig brusing and cleaning complete with cleaning solution and water replacing the dective PVC flage alogwith rubber gasket and rusted bolts nuts and washer etc cleaning the water sump ad XMP wire mesh with suitable cleaning solutio re-assemblig te same includnig replacing the defective water filter flages of pipe joints etc and testing complete all as specified and directed (PVC Files will be measured ad paid separetely for the followig:-

-

-

-

... More
15 TR Capacity plant installed at 37 AMSD A/C Plant

1

-

-

... More
95 TR Capacity plant installled at OT CC

1

-

-

... More
Serving of compressor unit by drainng out the used comprssor oil, opening both side coversh head covers and taking out the defective oil fillter cleaning the sump by using suitable cleaning solution replacinng the defective oil filter element checkig of solution and discharge valve adjust them and refixing the side covers head covers including replacing the suitable gasket complete and re-filling of new compressor oil to the required level, removing the pull cecking the serviceabiliyt of shaft seal ass, replacement of shaft assly and refixing the pull including replacing the defective gas filter and testing complete all as specified and directive by Egieeer in charge for the following :(Oil filter element gas filter and shaft seal will be measured and paid for separately)

-

-

-

... More
Compressor model JS43F 50B istallled at 37 AMSD of 7.5 TR/5 TR Capacity

1

-

-

... More
Supply and replacement of following items complete all as specified and directive b Engr In charge :

-

-

-

... More
Different pressure control switch Type MP-55 Make: Indfos/Danfos

1

-

-

... More
Low pressure cut out control switch MP-I Make: Idofos/dafos

2

-

-

... More
Pressure cut out cotrol switch MP-5 Make: INDFOS/DANFOS

2

-

-

... More
Oil pressuer cut out off switch MP-15 Make: INDFOS/DANFOS

2

-

-

... More
Oil pressure gauge 0 to 300 PSI, Make: FIEBEG/GURU

2

-

-

... More
Compound gauge (- 30 to 0 to 300 PSI, Make: FIEBEG/GURU

2

-

-

... More
Compoud gauge (- 30 to 0 to 150 PSI, Make: FIEBEG/GURU

2

-

-

... More
Water pressure guage (-0 to 150 PSI, Make: FIEBEG/GURU

2

-

-

... More
Hand sut off valve of size 1/4 x 1/4

2

-

-

... More
Solenoid control valve suitable for central AC Plant upto 95 TR Cap

2

-

-

... More
Condenser safety valve for central AC plant up to 95 TR

2

-

-

... More
Supply only 3 pole power contractor Type ML-1.5, 415/210 olt 50 Hz AC 16 Amps Make: L & T/ABB/SCEIDER

6

-

-

... More
Supply only 3 pole power contractor Type ML-4, 415/210 Volt 50 Hz AC 32 Amps Make: L & T/ABB/SCHNEIDER

6

-

-

... More
MCCB Three pole 415 Volt 50 Hz 160 Amps wit breaking capacity 25 KA type DT Make: L & T/ABB/SCHNEIDER/SIMESE

1

-

-

... More
MCCB Three pole 415 Volt 50 200 Amps with breaking capaciyt 25 KA type Make: L & T/ABB/SCHNEIDER/SIMESE

1

-

-

... More
Over load relays MK 1 Type relays range 4 to 6.5 Amps,1.5 to 2.5 Amps, 6 to 9 Amps, 9 to 14 Amps, 11 to 18 Amps Make: L & T/Autoix/MDS/SIMEMS OR Equivalent

3

-

-

... More
Over load relays Type relays range 60 to 100 Amps,37 to 60 Amps, indivisual mounting Make: L & T/Autoix/MDS/SIMEMS OR Equivalan

3

-

-

... More
Over load relays Type relays range 11 to 18 Amps, 9 to 14 Amps, 6 to 9 Amps, 9 to 14 Amps, 11 to 18 Amps Make: L & T/Autoix/MDS/SIMEMS OR Equivalent

2

-

-

... More
Push button pendants 6A, 415 V, 50 z with two push buttons size and shape as per site requirement of each plant.

6

-

-

... More
AC Amps meter 0 to 30 Amps direct reaching type Make : AE/PL/L&T/Standard.

4

-

-

... More
AC Amps meter 0 to 60 Amps Make : AE/PL/L&T/Standard

2

-

-

... More
AC Amps meter 0 to 100 Amps Make: AE/PL/L&T/Standard

3

-

-

... More
AC Amps meter 0 to 300 Amps Make: AE/PL/L&T/Standard

2

-

-

... More
AC Voltmeter electronic digital type 0 to 500 V as per sample Make: AE/PL/L&T/Standard

4

-

-

... More
Electronic timer switch 240/415 volt 50 Hz for 30 to 60 seconds Make: GIC/L&T

3

-

-

... More
Single phase prevetor suitable for 415 volt 50 z 3 phase as per existing type Make: L&T /Siemes

4

-

-

... More
Taking out the defective termostatic expasion valve and supply and fix termostatic expasion valve suitable for the followig :-

-

-

-

... More
Central AC Plant 95 TR Make: ALCO/IFOS

2

-

-

... More
Central AC Plant 15 TR Capacity Make: ALCO/IDFOSS

2

-

-

... More
Supply & fix pre-filter 10 to 20 micros stetic o wove both side DPE mesh I alumnium frame efficiecy 90% of sizes as per site requirement Make of Filter RAVI/ATLETE

24

-

-

... More
Supply and fix V Belt of following sizes:-

-

-

-

... More
V-Belt B-67

8

-

-

... More
V-Belt B-68

8

-

-

... More
V-Belt B-70

4

-

-

... More
V-Belt B-124

18

-

-

... More
Supply & charging of Refrigerant gas R-22 Make:- Refro/Fluro/Metro

183

-

-

... More
Supply only compressor oil I sealed cotainer maufactured by hindustan Petrolium limited as per site requiremet or equivalant as directed by engieer In charge.

40

-

-

... More
Material & Labour for cleaning the external surface of equipmet/accessories of central AC Plant 95 TR capaciyty istalled at C C ad paitig wit two coast of (a) Induction motor55 KW- 3 Nos. (b Compressor nuit 47.5 TR-3 Nos (c) Condenser unit -3 Nos (d) Chiller Unit - 3 Nos (e) Chiller unit -2 Nos (f) Condenser pump set -2 Nos (g) LT Control panel board cubical tpe for compressor chiller pumpset codesing pump set CT fan etc - 1 Nos (h) Cooling tower - 1 Nos (j) Condensing/discharge piping (approx) -50 RM (k) Chilled water pipe in flow and out flow ( approx -200 RM (l) AU of OT ICU other OT ad controlled boards, blower motor.

1

-

-

... More
Descriptiion all as per item No 76 ere-I before but central AC Plant 7.5 TR/5 TR Capacity installed at 37 AMSD and comprising of followig:- (a) Induction motor -11 KW- 2 Nos (b) Induction motor 5.5 KW- 2 Nos (c) Compressor uit 7.5 TR - 2 Nos (d) Compressor Uit 5 TR - 2 Nos (e) Condenser pump set - 2 Nos (f) LT Cotrol pael board cubical tpe- 1 Nos (g) Coolig tower for 7.5 TR & 5 TR - 1 Nos (h) Condenser uit for 7.5 TR (j) Condenser uit for 5 TR (k) AU uit & complete pipig etc

1

-

-

... More
M&L for termal isulatio to ciller pipe lie wit oe coat of bitumious pait poltee seet fiberglass wool tickess of te sould be 50 mmm wiremes ad cover wit POP/Wite cemet wit paitig to matc te existig complete as directed b egr I carge.

15

-

-

... More
M & L for earthig complete with galvanized steel earth plate electrode 600mmx600mmx6.0mm tick buried directlyI ground ( earth pit ot less than 2.25 Mtr below normal ground level with top edge plate not less than 1.5 meter below ormal ground level connected to galvanized earth wire of size 4mm dia as eartig lead by meas of both nuts cuck nuts and washers of galvanized iron earth lead including PCC pit i PCC 1:2:3 Tpe B-1 RCC cover made out of cement cocerete 1:2:3 ytpe B-1( usig 20mm graded crusted stone aggerate reniforced with TMT steel bars 8mm dia @ 150mm c/c both was with suitable handle and angle iron 40x40x5mm frame GI medium grade watering pipe 20mm bore and fuel with wire mes light grade proctection pipe 40mm bore up to mani board complete as show on electric plate o 3 of MES Sc 2009(Part-1 ad testing on completion all as directed ad taknig down the same item. Note: On testing after completion of earting if desired earth resistance is not obtained, the earting will be done by the contractor at is own risk & cost of the entire satisfaction of engieer in charge.

32

-

-

... More
M&L GI Pipe medium grade for cooling tower In repair of dia 40mm

15

-

-

... More
M&L GI Pipe medium grade for cooling tower In repair of dia 25mm

15

-

-

... More
M&L Gu metal gate valve iro weel ead, screwed both ends of dia 40 mm

4

-

-

... More
M&L Gu metal gate valve iro weel head, screwed both eds of dia 25 mm

4

-

-

... More
Disconnectig and isolating the compressor of Accel Make SMC 6- 100 Model from te existing AC system by putting plates to suction and discharge valve opening of the compresssor removing of interal parts cleaning of the oil parts througly replacemet of te followig parts icludig trust wasers,mirror parts like nuts , bolts etc including polising to te crak shaft ressemblig back all te serviceable parts after compelte overaulig removig of te dumm plates of the compressor including testnig commissioing complete all as directed Note : Spare parts & cosumable will be measured & paid separtel charging of compressor oil will be measured & paid separtely.

1

-

-

... More
Supply & fix the following spares for Accel Make SMC-6-100 Model Compressor icludig takig dow old unsericeable spare parts complete all as specified & as directed.

-

-

-

... More
Main bearing pump and seal end

1

-

-

... More
Cylinder liner

6

-

-

... More
Piston

6

-

-

... More
Piston ring

6

-

-

... More
Suction Strainer

1

-

-

... More
SV Reeds

6

-

-

... More
Discharge valve assembly

6

-

-

... More
CR Bearing

2

-

-

... More
Gasket Set

2

-

-

... More
Crank Shaft for suitable size

1

-

-

... More
O ring Set

1

-

-

... More
Rocker arm frame

1

-

-

... More
Oil pump gear

1

-

-

... More
Connecting Rod

6

-

-

... More
Valve springs.

6

-

-

... More
Supply & fix of shaft seal assembly of a make of compressor including removing of te userviceable shaft seal assembl as testnig all as specfied & as directed

6

-

-

... More
Disconnection & dismanting old unserviceable meter guage panel idoor type supply istallation testing of in door vertical type guage pael board made out of 2mm tick MS Seet & GI pipe of medium gauage 80mm dia as per required length comprising of the following :- (a) Suction Pressure 0 to 150 PSI. (b) Oil Pressure guage 0 to 300 PSI. (c) COP guage 0 to 300 PSI (d) DP guage - 0 to 400 PSI.. (e) ON OFF switch with all tpe of indicators (f) LP/HP/OP Pressure cutouts. Note: All pressure guage & cut out will be paid separtely under relavent item if Sc A (ii) Quoted rate by the contractor include check and tightig of all connectio wiht meter gauge and replacement of userviceable copper pipe of 1/4 dia LP/P Pressure cut outs OP pressure cut outs Water pressure cutouts Copper Tube of Size 1/2 inch dia Copper Tube of size 1/4 ic dia

5

-

-

... More
Dismanting of unserviceable spriker carefully & suppply & fix new spriker made out from alumniium die casting suitable for upto 100 TR Capacity cooling tower etc all as directed b Engieer In charge.

2

-

-

... More
Demolition of old PCC Platfrom form existing postion & costruction of n ew PCC platform suitable for installing of 95 TR Cap AU all as directed b Engr In charge.

1

-

-

... More
M&L for replacement of old/unserviceable water termostatic 0 to 30 degree cetigrade icludig necessary connectio/testing Complete all as specified & as directed.

12

-

-

... More
Takign out of old userviceable butterfly valve form existing pipe lie & supply and fixing new butterfly valve of size 100mm made out of mild steel including necessary modification of existnig pipe lie & replacment of faiges with new bolts & nuts etc complete replacement of flages with new bolt and nuts including all connected works all as directed b Engieer in charge Make:- Advace /Audco/Kirloskar/Neta

6

-

-

... More
Supply & fix new sypon connection on half inch size made out of GI Pipe Wit SS coatig suitable for fixing of existing pressure guage includnig stop cock of suitable size and all mioir items & taking down old userviceable.

6

-

-

... More
Supply & fix water pressure guage 0 to 10 KG 2/4 dia suitable for condenser chillar water lie including removing old userviceable pressure guage etc all as directed.

4

-

-

... More
Supply & fix factor made performace bag filters of 99 micro down to 5 micro of standard size with multiple pockets & self supporting filters bags with MS/GI aodised aluminum frame suitable for central AC Plant including replacement of bolts & nuts & taking down userviceable Make:- Aerosol/da/Mat/Zoflower.

12

-

-

... More
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32 Amps, 220 Volts complete suitable for window/ Split type complete all as specified and directed by Engr-in- charge.

5

-

-

... More
Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts by with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in- charge.

5

-

-

... More
Taking out old existing unserviceable front show grill and supply and fix new front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-charge (as per sample approved by GE)

4

-

-

... More
Taking out old existing unserviceable inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0Ton as existing shape, size and make complete all as specified and directed by Engr –in – charge. Make:- Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.

4

-

-

... More
Taking out old existing unserviceable outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size with out compressor complete all as specified and directed by Engr –in – charge. Make:- Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.

3

-

-

... More
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below:-

-

-

-

... More
M&L rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA.

5

-

-

... More
Description all as per ser item No.100 here - in-before but of capacity 5KVA.

25

-

-

... More
Description all as per ser item No.100 here - in-before but of capacity 2KVA

15

-

-

... More
Description all as per ser item No.100 here - in-before but of capacity 1KVA

15

-

-

... More
Description all as per ser item No.100 here - in-before but of capacity 0.5KVA

5

-

-

... More
M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC.

15

-

-

... More
M&L in replacement of Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA.

22

-

-

... More
M&L in replacement of circuit plate with connection wire.

40

-

-

... More
M&L in replacement of relay for 0.5KVA, 1KVA & 2KVA,16Amp 24V DC.

25

-

-

... More
M&L in replacement of Voltmeter 0- 300V, AC 75 Sqm.

25

-

-

... More
M&L in replacement of Ampre meter 0- 30Amp, AC 75 Sqm

25

-

-

... More
M&L in replacement of push switch

20

-

-

... More
M&L in replacement of time delay circuit.

25

-

-

... More
M&L in replacement of connector switch 30amp 220volts AC

15

-

-

... More
M&L in replacement of 3pin socket 5Amps,240volts.

25

-

-

... More
M&L in replacement of 3pin socket 15Amps,240volts.

10

-

-

... More
Supply and fixing water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in - Charge

15

-

-

... More
Taking out old existing unserviceable cooling coil and supply and fix new cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC all as specified and directed by Engr –in – charge.

10

-

-

... More
Taking out old existing unserviceable condensing coil supply and fix new condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC all as specified and directed by Engr –in – charge

7

-

-

... More
Rep/replacement PCB for LG /Voltas/Loyed/Hitachi/Godrej window type AC 1.5 ton / 2Ton capacity complete all as directed by Engr-in- charge

8

-

-

... More
Rep/replacement PCB for LG /Voltas/Hitachi/Loyed/Godrej split type AC 1.5ton/2Ton cap complete all as directed by Engr-in- charge .

17

-

-

... More
Taking out old existing unsv coil Senser supply and fix new coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge.

10

-

-

... More
Taking out old existing unsv Senser supply and fix new senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge.

10

-

-

... More
Taking out old unsv blower supply and fix new blower(plastic body) of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in- charge.

10

-

-

... More
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2 TR.

210

-

-

... More
Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2 TR.

3

-

-

... More
Supply and topping up of refrigerant gas R-600 in refrigerantor.

5

-

-

... More
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator .

5

-

-

... More
Supply & fixing in replacement of L -Shape thimble brass in pk(50Nos in one pkt) complete all as specified and directed by Engr-in- charge.

2

-

-

... More
Supply & fixing in replacement of L -Shape thimble brass in pk(50Nos in one pkt) complete all as specified and directed by Engr-in- charge.

3

-

-

... More
Supply and fix in replacement of unsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr –in –charge

12

-

-

... More
Supply & fixing flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in- charge.

7

-

-

... More
Taking out old existing unserviceable and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton. Make:- LG/Voltas/Hitachi/Godrej.

6

-

-

... More
Taking out old existing unserviceable and supply and fix new hermetic/Rotary sealed unit compressor and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to window type ACs/ Split Type ACs:- (a) Sealed unit (Compressor Rotary Type) Suitable for capacity 1.5 Ton Window type/spllit type ACs. Make:- LG/Godrej/Hitachi/universal

4

-

-

... More
Taking out old existing unserviceable and supply and fix new hermetic/Rotary sealed unit compressor and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to window type ACs/ Split Type ACs:- (a) Sealed unit (Compressor Rotary Type) Suitable for capacity 2Ton Window type/spllit type ACs Make:- LG/Godrej/Hitachi/universal.

4

-

-

... More
Taking out old existing unserviceable and supply and fix new hermitically /Rotary sealed unit compressor and making connection of suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per existing unit of latest new model of same manufacture with same specification conforming to original compressor including recharging with refrigerant gas F-22/R-134A,R-600, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and changing parts with gas brazing and leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to Water coolers, refrigerator and deep freezers:-

-

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 40/80 Ltr. Make:– Godrej / Blue Star /Voltas

5

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 60/120 Ltr. Make:- Godrej / Blue Star /Voltas.

4

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for Water cooler of capacity 150/180 Ltr. Make:– Godrej / Voltas /Blure Star.

3

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for 165/170 Ltr Refrigerator, Make:- Godrej /LG/Voltas.

4

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for 270 to 290 Ltr Refrigerator, Make:- Godrej /LG/Voltas

4

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) in original suitable for more thatn 310 Ltr Refrigerator, Make:- Godrej /LG/Voltas

4

-

-

... More
Taking out old existing unserviceable and supply and fix new sealed unit (compressor) suitable for 320 litres Deep Freezers in original, Make:- Godrej /Voltas/Blue Star

3

-

-

... More
Supply and fixi in replacement and testing of complete new Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts, bolts main lead as required etc against burnt defective motor of following capacity/Models as under :-

-

-

-

... More
Fan motor1/16 HP single shaft for water cooler Make:- Air master/Crompton.

4

-

-

... More
Fan motor1/20 HP single shaft for water cooler as per the original make of complete fan motor. Make:- Air master /Crompton

4

-

-

... More
Fan Motor 1/35HP single shaft for water cooler Make:- Air master/Crompton

5

-

-

... More
Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead. Make:- Air master/Crompton

4

-

-

... More
Supply and fixing in replacement of Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators.

4

-

-

... More
Supply and fixing in replacement of fan motor of 165/170 Litre Refrigerator and supply and fix new fan motor of existing make, shape and size directed by Engr-in-Charge.

4

-

-

... More
Description all as per Srl Item No 123 above but suitable for single door 310 litre Refrigerator complete all as specified and directed by Engr-in- Charge .

4

-

-

... More
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size all as directed by Engr-in-Charge

6

-

-

... More
Supply and fix in replacement & testing of Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete in all respect. Make:- Air master/ Crompton.

5

-

-

... More
Description same as Srl item No 126 but Blower Fan Motor single shaft for Split type AC complete with base, clamps, side holders, rubber bushes complete

5

-

-

... More
Description same as Srl item No 126 Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG Make. Make:- Air master/Crompton.

3

-

-

... More
Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd supply and fix new Multi purpose Running Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

20

-

-

... More
Taking out old existing unsv Starting Capacitor of capacity 120+150 mfd supply & fix new Multi purpose starting Capacitor of capacity 120/150 mfd for window/split AC complete all as specified and directed by Engr-in-charge (as per sample approved d by GE)

7

-

-

... More
Taking out old existing unserviceable Starting Capacitor of capacity 40+80 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/80 mfd for water cooler complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

8

-

-

... More
Taking out old existing unserviceable Starting Capacitor of capacity 40+60 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/60 mfd for water cooer complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

7

-

-

... More
Taking out old existing unserviceable Starting Capacitor of capacity 80/100mfd supply and fix new Multi purpose Running Capacitor of capacity 80/100 mfd for water cooler complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

10

-

-

... More
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 45+5 mfd supply and fix new Multi purpose running Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

20

-

-

... More
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 36+6 mfd supply and fix new Multi purpose running Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

12

-

-

... More
Taking out old existing unsv Multi purpose running Capacitor of capacity 10 mfd supply and fix new Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

5

-

-

... More
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 4 mfd supply and fix new Multi purpose running Capacitor of capacity 4 mfd for water cooler complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

5

-

-

... More
Taking out old existing UNSV muti purpose running capacitor of capacity of 20 Mfd supply and fix new multi purpose running capacitor of capacity 20 Mfd for water cooler complete all as specified and directed by Engineer -in- Charage( as per sample approved by GE)

9

-

-

... More
Taking out old existing UNSV thermostate and supply and fix new thermostate for water cooler for any capacity comp;lete all as specified and directed by Engineer -in- charge ( as per sample approved by GE)

10

-

-

... More
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2ton window type AC of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

2

-

-

... More
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

2

-

-

... More
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance all as directed by Engineer - in - charge

3

-

-

... More
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels

2

-

-

... More
Replacement of Khas khas set for the doors of desert coolers all as directed by engineer-in-charge

3

-

-

... More
Servicing window/split type air conditioner 1.5 TR capacities of any make by opening the indoor/ outdoor unit ,cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water ,greasing fan motor ,rectification of loose electric connections and replacement of u/s knobs of electrical items complete all as directed by the Eng in charge.

40

-

-

... More
Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning all as directed.

15

-

-

... More
Disconnecting and taking down unserviceable thermostat from split type AC and supply and fix new thermostat for split type AC 1.5/ 2.0 Ton cap AC and testing the same for satisfactory performance all as specified and as directed ,

7

-

-

... More
Pressure testing and rectifying leakage in the system of window/split air conditioner up to 2 TR capacity including testing for satisfactory performance, commissioning all as directed.

7

-

-

... More
Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-charge.

100

-

-

... More
Cleaning of coils of Window/Split by using alkaline based coil cleaner (Non Acid based) incl taking down filters, spraying the diluted alkaline based coil cleaner, leaving it for five minutes and then flushing with running water. Fixing back the filters. Testing & re-commissioning etc., all as directed by Engineer-in-Charge. Make:- C-Shine

10

-

-

... More
Taking out old existing unserviceable Fan motor 4x4 and supply and fix new Fan motor 4x4 for water cooler of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

5

-

-

... More
S&F in replacement of Sub main wiring with two single core PVC insulated, unsheathed copper conductor cable, 1100volts grade of size 4.0 sqmm, FRLS in and inculding concealed PVC conduit, heavy duty, ISI marked, of dia 25mm and thickness not less than 2mm with all accessories such as bends, Tees, elbows, reducer socket, bell mouth,tube ends etc including cutting chases, pinning in masonry walling & making good to facing by pointing / plastering in cement mortar 1:3 to ends or edges for concealed wiring inculding 4.00 sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified and directed. Note :- Two run of wire and single run of earth wire 1RM of PVC conduit shall be measured as one unit.

90

-

-

... More
Taking out old existing unserviceable diacharge valve and supply and fix new discharge valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

8

-

-

... More
Taking out old existing unserviceable suction valve and supply and fix new suction valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

8

-

-

... More
Taking out old existing unserviceable bush and supply and fix new bush of 1.5/2 ton split type AC .of any capacity makle LG/ Voltas complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

5

-

-

... More
Taking out old existing unserviceable filter drier and supply and fix new drier of Split /Window 1.5/2.0 Ton Ac LG. Sidwal, Carrier and Voltas (as per sample approved by GE) of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

10

-

-

... More
Taking out old existing unserviceable capillary and supply and fix new capillary of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

12

-

-

... More
Taking out old existing unserviceable dead Nut and supply and fix new dead nut of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

25

-

-

... More
Taking out old existing unserviceable NRV and supply and fix NRV of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge (as per sample approved d by GE)

15

-

-

... More
Supply and fix in replacement of unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split type AC working on both ( Hot & Cool) (as per sample approved by GE) and complete all as specified and directed by Engr-in- charge.

10

-

-

... More
Sub main wiring with two single core PVC insulated unsheathed copper conductor cable 1100 volts grade 6.0 Sq mm size HRFR in and including concealed PVC conduit heavy duty ISI marked 25mm dia non metallic with all accessories such as bends, Tees, elbows, reducer socket, bell mouth, tube ends etc. including cutting chases, pinning in masonry walling & making good to facing by pointing/plastering in cement mortar 1:3 to ends or edges for concealed wiring including 4.0 Sq mm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified and directed by Engr-in-Charge.Note : Two run of wire and single run of earth wire and 1 RM of PVC conduit shall be measured as one unit

90

-

-

... More
M&L for repair of Deep frezeer of capacity 320ltr capcity by dismatiling the whole condensing as well as cooling coil and finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confroming no leakage . The reassembling the same deep freezer by provinding proper insulation material at the disturbed area all as per entire satisfaction of Engineer-in- Charge.

5

-

-

... More
M&L for repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including provinding the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as complete all as specified and directed by Engr- in- Charge.

5

-

-

... More
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.

5

-

-

... More
Taking out old existing unserviceable foam insulation and supply and fix new foam insulation of 1.5/2 ton split type/window AC of any capacity complete all as specified and directed by Engr in charge (as per sample approved by GE)

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.