Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Jan 2025
Closing Soon6 Feb 2025
Tender Amount₹ 48,13,000 
Notes
Download

Costs

Summary

Comprehensive Repair Maint Of 33kv Main Receiving Stations And 33kv No I And Ii Incl Repair And Replacement Of Metering Eqpt And Yard Calibration And Connected Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing in repairs lightening arrestor expulsion type complete with all fittings transmission class, discharge capacity 65 kilo amps, suitable for 11 KV complete all as specified and directed.

2

-

-

... More
Repairing / Servicing the Air break isolating switch HT 11 KV 400 Amps by replacing the defective major spares including provn of minor bolts nuts etc complete all as specified and directed. Note :- Major spare will be measured & paid seperately under relevant item of BOQ.

4

-

-

... More
Supply and fixing in repairs 11 KV Airbreak switch Male contact/moving Contact Blade complete all as specified and directed.

24

-

-

... More
Supply and fixing in repairs 11 KV Airbreak switch Female contact/Fix Contact Jaw complete all as specified and directed.

24

-

-

... More
Supply and fixing in repairs 11 KV Airbreak switch MS jumper carrier complete all as specified and directed.

24

-

-

... More
Supply and fixing in repairs 11 KV Airbreak switch Back Connector plate complete all as specified and directed.

24

-

-

... More
M&L for Earthing of machinery/equipment Installed at power house/substation, using 25 x 3 mm copper strip and copper plate of size 300 x 300 x 3 mm, as earth electrode. earthing complete burried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connected to and including copper strip 25x3mm as earthing lead by means of bolts, nuts, check nuts and washers, test points made of copper Strip 25x3 mm, 10 cm long, PCC (1:2:4) type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC (1:2:4) type B-1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcoal, etc including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of SSR Part-I and connecte complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of copper strip upto 7.5 meter and protection pipe and watering pipe, complete all as specified and directed.

6

-

-

... More
Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm complete all as specified and directed.

483

-

-

... More
Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and directed.

550

-

-

... More
Supply and fixing in repairs cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95/120 sq mm, complete all as specified and directed.

4

-

-

... More
Supply and fixing in repairs cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95/120 sq mm complete all as specified and directed.

4

-

-

... More
Supply, laying jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 Core complete all as specified and directed.

882

-

-

... More
Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 Core complete all as specified and directed.

790

-

-

... More
Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 Core complete all as specified and directed.

480

-

-

... More
Supply, laying, jointing and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 Core complete all as specified and directed.

472

-

-

... More
Supply and fixing in repairs LT Control panel board, Outdoor type,double door, cubical type,Sloppy roof front and back both side openable door, pedestal mounted,CPRI approved with IP-54, overall size not less than 1500 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 1200 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Incoming :- a) MCCB 4 Pole, 630 Amp, 50 KA 415V, Adjustable thermal setting type - 01 No. b) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch - 01 Set c) Digital Amp Meter 0 - 700 Amp, size 96x96 mm square type with selector switch - 01 Set. d) Copper wound with CTR 700/5 - 01 set. e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.

2

-

-

... More
Outgoing :- a) MCCB 4 Pole, 200 Amp , 36 KA 415V, Adjustable thermal setting type - 02 Nos. b) MCCB 4 Pole, 100 Amp, 16 KA 415V, Adjustable thermal setting type - 02 Nos. c) MCCB 4 Pole, 63 Amp, 16 KA 415V, Adjustable thermal setting type - 01 Nos. d) Angle iron base frame made out of ISA 5050 of size 50 x 50 x 6 mm thick including PCC 1:3:6 (using 40 mm graded crushed stone aggregate) type C2 for foundation , total leg height 600 mm above ground level - 01 Job e) Three phase timer switch 20 amp - 01 No, complete all as specified and directed.

-

-

-

... More
Supply and fixing in repairs LT Control panel board, Outdoor type,double door, cubical type,Sloppy roof front and back both side openable door, pedestal mounted,CPRI approved with IP-54, overall size not less than 1200 x 1000 x 450 mm, having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 600 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set including necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under. Incoming :- a) MCCB 4 Pole, 400 Amp, 36 KA 415V, Adjustable thermal setting type - 01 No. b) Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch - 01 Set c) Digital Amp Meter 0 - 400 Amp, size 96x96 mm square type with selector switch - 01 Set. d) Copper wound with CTR 400/5 - 01 set (e) Indicator Lamps (LED type) showing R,Y, B phase - 01 set.

1

-

-

... More
Outgoing :- a) MCCB 4 Pole, 100 Amp, 16 KA 415V, Adjustable thermal setting type - 02 Nos. b) MCCB 4 Pole, 63 Amp, 16 KA 415V, Adjustable thermal setting type - 05 Nos. c) MCB TPN, 32/40 Amp 415V - 03 Nos. d) Angle iron base frame made out of ISA 5050 of size 50 x 50 x 6 mm thick including PCC 1:3:6 (using 40 mm graded crushed stone aggregate) type C2 for foundation , total leg height 600 mm above ground level - 01 Job

-

-

-

... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 300 KVA transformer, complete all as specified and directed

12

-

-

... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 600 KVA transformer, complete all as specified and directed

14

-

-

... More
M&L for replacement off load tap changer for distribution transformer of any make and capacity from 200-600 KVA, complete all as specified and directed

4

-

-

... More
M&L for replacement of bush type insulator brown in color working pressure 433 Volts LT side, complete all as specified and directed

12

-

-

... More
M&L for servicing and repairing of OLTC (ON load Tap changer) for 11 KV Transformer by disconnecting and dismantling all burnt out cables / fuses/ relays / contactors, toggle switch/knobs /indicators/reading units and other accessories repairs / replace the unserviceable items and making the OLTC in serviceable condition and connecting back to its original position, complete all as specified and directed.

2

-

-

... More
M&L for servicing of 33 KV VCB / 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed.

8

-

-

... More
M&L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report all as directed. Note : PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid, complete all as specified and directed

6

-

-

... More
Supply and fixing in repairs the following spares for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 & VCB 11 KV 400 A 25 KA 250MVA:-

-

-

-

... More
Closing coil 24/30V DC

2

-

-

... More
Tripping coil 24/30V DC

2

-

-

... More
Antipumping device 24/30V DC

3

-

-

... More
33 KV porcelain bushing for VCB Top

3

-

-

... More
33 KV porcelain bushing for VCB bottom

3

-

-

... More
Connector strip 16 way

4

-

-

... More
Earth Fault and over current relay of L & T Model No MC61A 24-110V

3

-

-

... More
Digital type power factor indicator meter

4

-

-

... More
Digital type Voltmeter / Ammeter 96 x 96 mm size

4

-

-

... More
LED type indicator lamp assembly

5

-

-

... More
Vacuum Interrupter for indoor VCB

2

-

-

... More
Spout incoming side

3

-

-

... More
Spout outgoing side

4

-

-

... More
Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs

11

-

-

... More
Insulated Copper bus bar of existing size and thickness for VCBs

2

-

-

... More
Gear system assembly complete with handle for charging / discharging of VCBs

2

-

-

... More
Spring charging motor for VCBs

1

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in any type soil for taking up or laying of cable complete all as specified and directed.

829.8

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.

675.4

-

-

... More
Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point, complete all as specified and directed

154.4

-

-

... More
Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness shall be measured for payment purpose.

129.2

-

-

... More
M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.

14.9

-

-

... More
Supply and fixing in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of size 80 mm dia complete all as specified and directed.

42

-

-

... More
Supply and fixing in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of size 100 mm dia complete all as specified and directed.

36

-

-

... More
M&L for graded coarse aggregate, broken stone or boulders of size 40 mm in sub - station yard for laying complete all as directed and specified.

22

-

-

... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed.

6

-

-

... More
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed.

4

-

-

... More
Notes :- An amount of Rs. 155071.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.