Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Civil And Construction
Drainage Work
Eprocure
Opening Date1 Aug 2022
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No 34

1

-

82042.11

... More
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 35

1

-

10124.08

... More
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 39

1

-

166483901.45

... More
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 41

1

-

2244813.07

... More
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 42

1

-

1234190.07

... More
Lump sum price worked out by the contractor for SECURITY WALL & GATE WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 44

1

-

2377046.12

... More
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 47

1

-

1024665.31

... More
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTH WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 49

1

-

27200883.56

... More
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 56

1

-

3235691.38

... More
SCH 'A' Part-XI (STP WORKS FOR 800KL/day)

-

-

-

... More
Designing, Supply, fixing, testing , installation & commissioning of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) having capacity of 800 KLD including entire civil and electromechanical works for complete functioning of STP along with requisite electrical control panels, all interconnecting pipes, cables and wires related to plant of capacity 800 KLD. The waste water coming out of plant is to be recycled for horticulture, MT wash / disposed off to river or as directed including all connected civil works complete including all as follows as per the OEM specifications to achieve the parameters mentioned as following:-

1

-

-

... More
(A) MECHANICAL UNITS & CIVIL UNITS (a) 01 No collection chamber of 3.45 m depth & dia 6 m of the tank from ground level in RCC M-30 construction. (b) 03 Nos raw sewage pumps (2W+1S) non clog submersible pump with chrome steel impeller and cutter non clog to pass 40 mm size particles of capacity 5.5 HP of flow capacity 1668 LPM for each pump with timer switch for auto operation of centrifugal. (c) 01 No stilling chamber in RCC M-30 construcion size 1.70 m x1.5 m x1.30 m (depth including free board). (d) 02 Nos Screen chamber in mild steel epoxy painted construction in RCC M-30 of size 2.00 m X0.3 m X0.75 m (depth including free board) and appropriate wier after bath screen to be provided to maintain depth & velocity. (e) 02 No. fine bar screen with clear spacing of 6 mm thickness of bar size 10 mm angle of placement of screen 60°width of side frame 25 mm provide slope in the chamber 1 in 10 and 02 No of coarse bar screen with clear spacing 12 mm of bar size 25X 5 mm thick MS flat epoxy painted construction. (f) 02 Nos Oil & greese trap/ grit chamber in RCC M-30 Construction of size 2.80 m x0.90m x 0.60m (depth including free board). Use baffle wall at 0.5 M from end of grit channel to get the water flow from bottom. Skim out the top oil and greese. (g) 01 No Equilization tank (EQT) in RCC M-30 construction with rung ladder of size 7.00 m x 9.00 m x 4.5 m (including 0.2 m free board ) with air grid of height 0.3 m of coarse bubble, lateral and header type for Equilization tank and MBBR reactors.

-

-

-

... More
(h) 04 Nos non clog submersible raw sewage pumps (2W+2S)( Provide 1W + 1S for each MBBR Tank) of flow capacity 278 LPM with chrome steel impeller and cutter, non clog to pass 40 mm size particles of capacity 2 HP (j) 02 Nos(in Series) & 02 Nos(in parallel) moving bed bio reactor with fluid media in PP construction, RCC M-30 construction of size 3.30 m x 3.30 m x 4.00 m (including 0.2 m free board and air grid of height 0.3 m ) with retention time 3.5 Hrs in each tank., with Air grid of coarse bubble , lateral & header type alongwith 02 Nos (1W+ 1S) twin lobe roots type positive displaced air blower of capacity 1900 Cum / Hr Surface area of media 500 Sqm / Cum percentage of reactor required 35% & vol of each reactor required 37.89 Cum (k) 02 lot of tubesettler internal of square type in PVC media in 2 Nos tubesettler tank RCC M-30 construction of size 2.5 m x 1.55m x 2 m with angle of INCLINATION 60° length of tubesettler pack 1 m. Tubesettler to be placed at 0.75 m from the flat bottom keeping 0.25 m gap at the top. Bottom of the settler to be made sloping at 45°towards center from all sides to remove sludge from bottom. Additional depth to be considered as per design requirement for provision of slopping bottom.

-

-

-

... More
(l) 1 No. Dewatering Poly Electrolyte (DWPE) dosing system consisting of metering type dosing pump of 0-17 LPH in PP constructions and LDPE/ HDPE dosing tank of 500 Litres capacity. (m) 1 No. Poly aluminium chloride (PAC) dosing system consisting of 01 No electronics metering type dosing pump in PP construction capacity suitable for plant and 01 No. LDPE/ HDPE dosing tank of capacity 200 Ltrs. (n) 1 No. (1 No. for CCT) of Hypo dosing system consisting of metering type dosing pump of capacity 27 LPH in PP construction and LDPE/HDPE dosing tank of 500 Litres capacity. (o) 01 No of Filter feed tank in RCC M-30 construction of depth 3 m and dia 6 m with retention time 2 Hr (p) 2 Nos. (1W+1S) Centrifugal Monobloc Filter Feed Pumps for pumping secondary stage treated water to Filters of capacity 33.0 m3/hr @ 35 m Head. (This pumps will also act as filters back wash pumps). (q) 2 Nos. Multi Grade Filter (MGF) & 02 Nos Activated Carbon Filter (ACF) of 16 hr operation of filtration capacity 12 Cum/ Sqm/ Hr of dia not less than 1.7m. The pumping and back washing arrangement to be supplied by the manufacturer as per requirement. The dimensions may vary as per vendor equipment.

-

-

-

... More
(r) 01 No treated water tank in RCC M-30 construction of volume 217 Cum and size 6.4 m x 6.4m x5.3 m (depth including free board) (s) 01 No sludge holding tank in RCC M-30 construction of size 1.4 m X 1.3 m x 2 m (depth including 0.3 m free board and 0.3 m air grid). Rust proof material with coarse diffuser to be used for air grid. 2 Nos. (1W+1S) Sludge Feed Pumps (Screw Type) for Sludge Transfer from Sludge Holding Tank to Centrifuge System of capacity 1.0 m3/hr @ 35 m Head. (t) 01 No of disinfection tank with retention time 30 minutes of size 2.90 mx 2.90 m x2.3 m (depth including free board).disinfection used hypo (sodium Hypochloride) 6% Cl2 and chlorine dosage 4 mg/ Lit CCT inlet. Process of dosing should be sodium hypo solution through hypo dosing pump. (u) 02 Nos parallel Anoxic Tank with surface area of media 500 sqm/ Cum percentage of carrier fill 20% HRT230 min Volume of each reactor required 68.32 Cum of size 4.50 m x 4.50 m x4.00 m ( depth including 0.2 m free board and 0.3 m air grid). Anoxic system have nonsubmersible centrifugal recycling pump of capacity as per designed by OEM -2 Nos(1W+1S) for sludge recycling from MBBR to Anoxic tank.

-

-

-

... More
(v) 02 Nos Air comrpessor of capacity 1900 Cum/ Hr (Air required for equilization tank 300 Cum / Hr, air required for sludge holding tank 80 Cum/ Hr, Air Required for MBBR A1 494 Cum per Hr, Air Required for MBBR B1 for 494 Cum Hr, Air Required for MBBR A2 266 per Cum Hr, cycling timer to be provided for switching between compressors. Vendor have to be provide provision of blowing hot air using compressor in winters as per note given below. (w)1 No. Solid Bowl Type, counter current Centrifuge of capacity 1.0 m3/hr having frame of Mild Steel and Casing in SS 304 (x) 1 Lot of interconnecting piping and valves for all units with MS ‘B’ Class pipe of STP.

-

-

-

... More
(y) 1 No. Electrical Distribution Board having controls of STP Operation as per specification mentioned here under: (i) Single Incomer, Non-Compartmentalized non draw out type, Fuseless type, Single front, Top entry, CRCA, RAL7032, Free standing, Floor mounted Panel Make: Fabricated panel from STP OEM Approved vendor. (ii) Main Busbar: Aluminium (iii) Control Busbar: Copper (iv) Earth Busbar: 50x10MM Al (H), 25x10MM Al (V) (v) Fault level: 50kA for 1 sec Switch gearof Make: Siemens/ABB, VFD of Make: ABB/Siemens/Danfoss (vi) Incomer (Suitable connected load to be designed by the tenderer duly vetted by any IIT/NIT and approved by Accepting Officer): MCCB (3P, TOLR, with U/V) MFM with RS485 communication. (vii) No space heater with thermostat, Illumination Lamp and Door limit Switch to be provided. (viii) Outgoing Feeders(3 phase): MPCB + Contactor (ix) Outgoing Feeders(1 phase): MCB+Relay (x) Others- 100MM base channel - L/R selection considered in MCC - No spare feeders considered. Note:- The capacity and quantity of outgoing feeders/ switch gear has to be designed by the tenderer as per their specification.

-

-

-

... More
(B) Power/Control Cable & termination Accessories (a)Power Cables: (i) 3 Core, XLPE / PVC insulation, Armoured, Up to 6 Sq.mm Cu conductor cable (ii) Above 6Sq.mm Al conductor cable is to be provided. (b)Control Cables: (i) 4 Core, XLPE / PVC insulation, Armoured, 1.5 Sq.mm Cu conductor cable is to be provided. - Make of cables-Polycab, Havells, Finolex (c) Termination Accessories (i) Double compression Ni plated brass glands with earth strips to be provided (ii) Non insulated Al/Cu Lugs of suitable conductor size are to be provided

-

-

-

... More
(C) Trays with tray supports (a) Tray material - Hot dripped GI Cable Trays Make: IEI Approved vendor. (b) Types of cable tray - Ladder and perforated type with coupler plates and joining accessories (c) Minimum Sizes to be provided - 2mm thick 600mm(W)X2500mm(L)X50mm(H) - Ladder 300mm(W)X2500mm(L)X50mm(H) - Ladder 450mm(W)X2500mm(L)X75mm(H) – Ladder 150mm(W)X2500mm(L)X50mm(H) - Ladder 100mm(W)X2500mm(L)X50mm(H) - Perforated 50mm(W)X2500mm(L)X50mm(H) - Perforated Hot dipped galvanised iron tray supports are to be provided at regular interval of 2.5mtrs

-

-

-

... More
(D) LBPS (a) Make: As approved by Accepting Officer. (b) For manual operation of drives Enclosure - CRCA , MS powder coated with RAL 7032 paint shade, IP65 protection For 3 Phase drives - LPBS with Start/Stop PB with Push release type PB and mushroom head Stop PB with key with 1 NO+1NC contacts for each PB,For 1 Phase drives- Plug and socket .

-

-

-

... More
(E) Above ground Earthing (a) As per IS3043- Size is based on short circuit capacity of 50kA for 1sec (b)Cross section of earth strips or wires of suitable sized and body earthing E&I equipment are to be provided. GI strip will be provided as MOC for earthing. (i) 1 Lot of Interconnecting cabling and cable tray for all units of STP. (ii) 1 Lot of Level Switches for Raw Water Tank (RWT) and Clarified Water Tank (CWT) (F)Shed for STP Plant as per manufacturer's recommendation each plant. (G) All interconnecting piping & valves of all units of STP. (H) For movement suitable path beween various units of STP .

-

-

-

... More
NOTES : Rates deemed to include cost of following:- (i) 1 Lot of foundation for Pumps, Blowers and other equipments as required in PCC and starters. (ii) Suitable Temperature control measure insulation of pipeline and heating arrangement shall be adopted for winter season upto (-) 10 degree celcius at altitude of 1600 mtr / Extra bacterial culture suitable for winter temperature shall be mixed in the MBBR chamber for multiplying the bacteria. The culture should maintain the pH of sewage in the neutral range. (iii) Contractor has to submit drawing & technical specification duly vetted by NIT/IIT and approved by Accepting officer before commencement of work. (iv) Contractor has to submit drawing & technical specification of LT Paner before placing order for approval of GE. (v) Rates also included pre painted galvalume aluminium zinc coating GI bassed corrugated steel sheet 0.50mm thick with mild steel framed structure including two coats of synthetic enamel paint over a coat of red oxide primer including necessary welding, base plate, gusset plate, excavation, RCC work in foundation. Foundation design shall be based on load bearing capacity of soil at a depth of 1.5M from GL covering from bar screen chamber to activated carbon filter (ACF) having both side slope of 1 : 3 with clear height 3 Mtr on all sides and 1.50m clear space on all sides from civil structure 60 mm thick machine pressed precast concerete interlocking paver block any slope and size M-35 Grade over 50mm thick sand cushion to be laid at 1.5M clear space on all sides from Civil structure. The structure will be designed for loading as per IS 800, the design will be get approved by Accepting Officer before work commenced. No side cladding is required.

-

-

-

... More
SCH 'A' Part-XII (STP WORKS FOR 1500KL/day)

-

-

-

... More
Designing, Supply, fixing, testing , installation & commissioning of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) having capacity of 1500 KLD including entire civil and electromechanical works for complete functioning of STP along with requisite electrical control panels, all interconnecting pipes,cables and wires related to plant of capacity 1500 KLD. The wastewater coming out of plant is to be recycled for horticulture, MT wash / disposed off to river or as directed including all connected civil works complete including all as follows as per the OEM specifications to achieve the parameters mentioned as following

1

-

-

... More
(A) MECHANICAL UNITS & CIVIL UNIT (a) 01 No collection chamber of 4.35 m depth & dia 8 m of the tank from ground level in RCC M-30 construction. (b) 03 Nos raw sewage pumps (2W+1S) non clog submersible pump with chrome steel impeller and cutter non clog to pass 40 mm size particles of capacity of 1045 LPM, 10 HP for each pump with timer switch for auto operation of centrifugal. (c) 01 No stilling chamber in RCC M-30 construcion size 2.10 m x1.90 m x1.50 m (depth including free board). (d) 02 Nos Screen chamber in mild steel epoxy painted construction in RCC M-30 of size 2.00 m X0.3 m X0.75 m (depth including free board) and appropriate wier after bath screen to be provided to maintain depth & velocity. (e) 02 No. fine bar screen with clear spacing of 6 mm thickness of bar 10 mm angle of placement of screen 60°width of side frame 25 mm provide slope in the chamber 1 in 10 and 02 No of coarse bar screen with clear spacing 12 mm of bar size 25X 5 mm thick MS flat epoxy painted construction. . (f) 02 Nos Oil & greese trap/ grit chamber in RCC M-30 Construction of size 4.70 m x1.00m x 0.60 m (depth including free board). Use baffle wall at 0.5 M from end of grit channel to get the water flow from bottom. Skim out the top oil and greese.

-

-

-

... More
(g) 01 No Equilization tank (EQT) in RCC M-30 construction with rung ladder of size 10.00 m x 12.00 m x 4.5 m (including 0.2 m free board and air grid of height 0.3 m ) with air grid of height 0.3 m of coarse bubble, lateral and header type for Equilization tank and MBBR reactors. (h) 04 Nos non clog submersible raw sewage pumps (2W+2S)( Provide 1W + 1S for each MBBR Tank) of flow capacity 521 LPM with chrome steel impeller and cutter, non clog to pass 40 mm size particles of capacity 3.5 HP (j) 02 Nos(in Series) & 02 Nos(in parallel) moving bed bio reactor with fluid media in PP construction, RCC M-30 construction of size 4.00 m x 4.00 m x5.00 m (including 0.2 m free board and air grid of height 0.3 m ) with retention time 3.5 Hrs in each tank., with Air grid of coarse bubble , lateral & header type alongwith 02 Nos (1W+ 1S) twin lobe roots type positive displaced air blower of capacity 2700 Cum / Hr (k) 02 lot of tubesettler internal of square type in PVC media in 2 Nos tubesettler tank RCC M-30 construction of size 3.2 m x 2.1m x 2 m with angle of incination 60° length of tubesettler pack 1 m. Tubesettler to be placed at 0.75 m from the flat bottom keeping 0.25 m gap at the top. Bottom of the settler to be made sloping at 45°towards center from all sides to remove sludge from bottom. Additional depth to be considered as per design requirement for provision of slopping bottom.

-

-

-

... More
(l) 1 No. Dewatering Poly Electrolyte (DWPE) dosing system consisting of metering type dosing pump of 0-32 LPH in PP constructions and LDPE/ HDPE dosing tank of 1000 Liters capacity. (m) 1 No. Poly aluminium chloride (PAC) dosing system consisting of 01 No electronics metering type dosing pump in PP construction capacity suitable for plant and 01 No. LDPE/ HDPE dosing tank of capacity 200 Ltrs. (n) 1 No. (1 No. for CCT) of Hypo dosing system consisting of metering type dosing pump of capacity 0-52 LPH in PP construction and LDPE/HDPE dosing tank of 2000 Liters capacity with agitator for properly mixing of solution . (o) 01 No of Filter feed tank in RCC M-30 construction of depth 3.25 m and dia 8 m with retention time 2 Hr (p) 2 Nos. (1W+1S) Centrifugal Monobloc Filter Feed Pumps for pumping secondary stage treated water to Filters of capacity 70 m3/hr @ 20 m Head. (This pumps will also act as filters back wash pumps). (q) 2 Nos. Multi Grade Filter (MGF) & 02 Nos Activated Carbon Filter (ACF) of 16 hr operation of filtration capacity 12 Cum/ Sqm/ Hr of dia not less than 2.3 m. The pumping and back washing arrangementbto be supplied by the manufacturer as per requirement. The dimensions may vary as per vendor equipment. (r) 01 No treated water tank in RCC M-30 construction of volume 401 Cum and size 8.7 m x 8.7m x5.3 m (depth including free board)

-

-

-

... More
(s) 01 No sludge holding tank in RCC M-30 construction of size 1.9 m X 1.8 m x 2 m (depth including 0.3 m free board and 0.3 m air grid). Rust proof material with coarse diffuser to be used for air grid.alongwith 2 Nos. (1W+1S) Sludge Feed Pumps (Screw Type) for Sludge Transfer from Sludge Holding Tank to Centrifuge System of capacity 2.0 m3/hr @ 35 m Head. (t) 01 No of disinfection tank with retention time 30 minutes of size 4.00 mx 4.00 m x2.3 m (depth including free board).disinfection used hypo (sodium Hypochloride) 6% Cl2 and chlorine dosage 4 mg/ Lit CCT inlet. Process of dosing should be sodium hypo solution through hypo dosing pump. (u) 02 Nos parallel Anoxic Tank with surface area of media 500 sqm/ Cum percentage of carrier fill 20%, HRT 230 min Volume of each reactor required 128.09 Cum of size 5.40 m x 5.40 m x 5.00 m ( depth including 0.2 m free board and 0.3 m air grid). Anoxic system have nonsubmersible centrifugal recycling pump of capacity as per designed by OEM -2 Nos(1W+1S) for sludge recycling from MBBR to Anoxic tank. (v) 02 Nos Air compressor of capacity 2700 Cum/ Hr (Air required for equilization tank 430 Cum / Hr, air required for sludge holding tank 110 Cum/ Hr, Air Required for MBBR A1 702 Cum Hr, Air Required for MBBR B1 702 Cumper Hr, Air Required for MBBR A2 378 Cum per Hr, cycling timer to be provided for switching between compressors. Vendor have to be provide provision of blowing hot air using compressor in winters as per note given below.

-

-

-

... More
(w)1 No. Solid Bowl Type, counter current Centrifuge of capacity 1.0 m3/hr having frame of Mild Steel and Casing in SS 304 (x) 1 Lot of interconnecting piping and valves for all units with MS ‘B’ Class pipe of STP. (y) 1 No. Electrical Distribution Board having controls of STP Operation as per specification mentioned here under: (i) Single Incomer, Non-Compartmentalized non draw out type, Fuseless type, Single front, Top entry, CRCA, RAL7032, Free standing, Floor mounted Panel Make: Fabricated panel from STP OEM Approved vendor. (ii) Main Busbar: Aluminium, (iii) Control Busbar: Copper (iv) Earth Busbar: 50x10MM Al (H), 25x10MM Al (V) (v) Fault level: 50kA for 1 sec Switch gear of Make: Siemens/ABB VFD of Make: ABB/Siemens/Danfoss (vi) Incomer (Suitable connected load to be designed by the tenderer duly vetted by any IIT/NIT and approved by Accepting Officer): MCCB (3P, TOLR, with U/V) MFM with RS485 communication.

-

-

-

... More
(vii) No space heater with thermostat, Illumination Lamp and Door limit Switch to be provided. (viii) Outgoing Feeders(3 phase): MPCB + Contactor (ix) Outgoing Feeders(1 phase): MCB+Relay (x) Others- 100MM base channel - L/R selection considered in MCC - No spare feeders considered. Note:- The capacity and quantity of outgoing feeders/ switch gear has to be designed by the tenderer as per their specification. (B) Power/Control Cable & termination Accessories (a)Power Cables: (i) 3 Core, XLPE / PVC insulation, Armoured, Up to 6 Sq.mm Cu conductor cable (ii) Above 6Sq.mm Al conductor cable is to be provided. (b)Control Cables: (i) 4 Core, XLPE / PVC insulation, Armoured, 1.5 Sq.mm Cu conductor cable is to be provided. Make of cables-Polycab/Havells/Finolex (c) Termination Accessories (i) Double compression Ni plated brass glands with earth strips to be provided (ii) Non insulated Al/Cu Lugs of suitable conductor size are to be provided

-

-

-

... More
(C) Trays with tray supports (a) Tray material - Hot dipped GI Cable Trays Make: IEI Approved vendor. (b) Types of cable tray - Ladder and perforated type with coupler plates and joining accessories (c) Minimum Sizes to be provided - 2mm thick 600mm(W)X2500mm(L)X50mm(H) - Ladder 300mm(W)X2500mm(L)X50mm(H) - Ladder 450mm(W)X2500mm(L)X75mm(H) – Ladder 150mm(W)X2500mm(L)X50mm(H) - Ladder100mm(W)X2500mm(L)X50mm(H) - Perforated 50mm(W)X2500mm(L)X50mm(H) - Perforated Hot dipped galvanised MS tray supports are to be provided at regular interval of 2.5mtrs (D) LBPS (a) Make:As approved by Accepting Officer. (b) For manual operation of drives Enclosure - CRCA , MS powder coated with RAL 7032 paint shade, IP65 protection for 3 Phase drives - LPBS with Start/Stop PB with Push release type PB and mushroom head Stop PB with key with 1 NO+1NC contacts for each PB, For 1 Phase drives- Plug and socket .

-

-

-

... More
(E) Above ground Earthing (a) As per IS3043- Size is based on short circuit capacity of 50kA for 1sec (b)Cross section of earth strips or wires of suitable sized and body earthing E&I equipment are to be provided. GI strip will be provided as MOC for earthing. (i) 1 Lot of Interconnecting cabling and cable tray for all units of STP. (ii) 1 Lot of Level Switches for Raw Water Tank (RWT) and Clarified Water Tank (CWT) (F)Shed for STP Plant as per manufacturer's recommendation each plant. (G) All interconnecting piping & valves of all units of STP. (H) For movement suitable path beween various units of STP .

-

-

-

... More
NOTES : Rates deemed to include cost of following:- (i) 1 Lot of foundation for Pumps, Blowers and other equipments as required in PCC and starters. (ii) Suitable Temperature control measure insulation of pipeline and heating arrangement shall be adopted for winter season upto (-) 10 degree celcius at altitude of 1600 mtr / Extra bacterial culture suitable for winter temperature shall be mixed in the MBBR chamber for multiplying the bacteria. The culture should maintain the pH of sewage in the neutral range. (iii) Contractor has to submit drawing & technical specification duly vetted by NIT/IIT and approved by Accepting officer before commencement of work. (iv) Contractor has to submit drawing & technical specification of LT Paner before placing order for approval of GE. (v) Rates also included pre painted galvalume aluminium zinc coating GI bassed corrugated steel sheet 0.50mm thick with mild steel framed structure including two coats of synthetic enamel paint over a coat of red oxide primer including necessary welding, base plate, gusset plate, excavation, RCC work in foundation. Foundation design shall be based on load bearing capacity of soil at a depth of 1.5M from GL covering from bar screen chamber to activated carbon filter (ACF) having both side slope of 1 : 3 with clear height 3 Mtr on all sides and 1.50m clear space on all sides from civil structure 60 mm thick machine pressed precast concerete interlocking paver block any slope and size M-35 Grade over 50mm thick sand cushion to be laid at 1.5M clear space on all sides from Civil structure. The structure will be designed for loading as per IS 800, the design will be get approved by Accepting Officer before work commenced. No side cladding is required.

-

-

-

... More
SCH 'A' Part-XIII (STP WORKS FOR 15KL/day)

-

-

-

... More
Designing, Supply, fixing, testing , installation & commissioning of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) having capacity of 15 KLD including entire civil and electromechanical works for complete functiong of STP along with requisite electrical control panels, all interconnecting pipes,cables and wires related to plant of capacity 15 KLD. The wastewater coming out of plant is to be recycled for horticulture, MT wash / disposed off to river or as directed including all connected civil works complete including all as follows as per the OEM specifications to achieve the parameters mentioned as following

1

-

-

... More
(A) MECHANICAL UNITS & CIVIL UNITS (a) 01 No collection chamber size 15 Cum in RCC M-30 construction. (b) 03 Nos raw sewage pumps (2W+1S) non clog submersible pump with chrome steel impeller and cutter non clog to pass 40 mm size particles of capacity 1.25 m3/hr @ 10 mwc for each pump with timer switch for auto operation of centrifugal. (c) 01 No stilling chamber in RCC M-30 construcion of Size 0.04 Cum (depth excluding free board). (d) 02 Nos Screen chamber in mild steel epoxy painted construction in RCC M-30 of size 1.00 m X 0.5 m X 1.0 m (depth including free board) and appropriate wier after bath screen to be provided to maintain depth & velocity. (e) 02 No. fine bar screen with clear spacing of 6 mm thickness of bar 10 mm angle of placement of screen 60°width of side frame 25 mm provide slope in the chamber 1 in 10 and 02 No of coarse bar screen with clear spacing 12 mm of bar size 25X 5 mm thick MS flat epoxy painted construction.

-

-

-

... More
(f) 02 Nos Oil & greese trap/ grit chamber in RCC M-30 Construction of size 1.0 m x 1.05 m x 2.5 m (depth including free board). Use baffle wall at 0.5 M from end of grit channel to get the water flow from bottom. Skim out the top oil and greese. (g) 01 No Equilization tank (EQT) in RCCM-30 construction with rung ladder of size 2.00 m x 2.00 m x 2.5 m (including 0.2 m free board) with air grid of height 0.3 m of coarse bubble, lateral and header type for Equilization tank and MBBR reactors. (h) 04 Nos non clog submersible raw sewage pumps (2W+2S)( Provide 1W + 1S for each MBBR Tank) of flow capacity 0.75 Cum/ Hr with chrome steel impeller and cutter, non clog to pass 40 mm size particles

-

-

-

... More
(j) 02 Nos(in Series) & 02 Nos(in parallel) moving bed bio reactor with fluid media in PP construction,mild steel epoxy coated tank construction of size 3.38 m x 2.13 m x 2.00 m (including 0.2 m free board and air grid of height 0.3 m ) with retention time 3.5 Hrs in each tank., with Air grid of coarse bubble , lateral & header type in SS304 construction alongwith 02 Nos (1W+ 1S) twin lobe roots type positive displaced air blower of capacity 50 Cum / Hr (k) 02 lot of tubesettler internal of square type in PVC media in 2 Nos tubesettler tank MS 5mm Thick construction of size 2.5 m x 1.55m x 2 m with angle of inclination 60° length of tubesettler pack 1 m. Tubesettler to be placed at 0.75 m from the flat bottom keeping 0.25 m gap at the top. Bottom of the settler to be made sloping at 45°towards center from all sides to remove sludge from bottom. Additional depth to be considered as per design requirement for provision of slopping bottom.

-

-

-

... More
(l) 1 No. Dewatering Poly Electrolyte (DWPE) dosing system consisting of metering type dosing pump of 0-1 LPH in PP constructions and LDPE/ HDPE dosing tank of 50 Liters capacity. (m) 1 No. Poly aluminium chloride (PAC) dosing system consisting of 01 No electronics metering type dosing pump in PP construction capacity suitable for plant and 01 No. LDPE/ HDPE dosing tank of capacity 50 Ltrs. (n) 1 No. (1 No. for CCT) of Hypo dosing system consisting of metering type dosing pump of capacity 0-1.25 LPH in PP construction and LDPE/HDPE dosing tank of 50 Liters capacity with agitator for properly mixing of solution . (o) 01 No of Filter feed tank in RCC M-30 construction of depth 2.25 m and dia 3 m with retention time 2 Hr (p) 2 Nos. (1W+1S) Centrifugal Monobloc Filter Feed Pumps for pumping secondary stage treated water to Filters of capacity 1.2 m3/hr @ 35 m Head. (This pumps will also act as filters back wash pumps).

-

-

-

... More
(q) 2 Nos. Multi Grade Filter (MGF) & 02 Nos ACF Activated Carbon Filter (ACF) of 16 hr operation of filtration capacity 12 Cum/ Sqm/ Hr of dia not less tha 1.7m. The pumping and back washing arrangementbto be supplied by the manufacturer as per requirement. The dimensions may vary as per vendor euipment. (r) 01 No treated water tank in RCC M-30 Thick construction of volume 16.2 Cum and size 3 m x 3 m x 1.8 m (depth including free board) (s) 01 No sludge holding tank below in RCC M-30 Thick construction of size 2.0mx2.0mx1.78m depth including 0.3 m free board and 0.3 m air grid). Rust proof material with coarse diffuser to be used for air grid. 2 Nos. (1W+1S) Sludge Feed Pumps (Screw Type) for Sludge Transfer from Sludge Holding Tank to Centrifuge System of capacity 0.5 m3/hr @ 35 m Head. (t) 01 No of disinfection tank with retention time 30 minutes of size of 3.6 Cum .disinfection used hypo (sodium Hypochloride) 6% Cl2 and chlorine dosage 4 mg/ Lit CCT inlet. Process of dosing should be sodium hypo solution through hypo dosing pump. (u) 02 Nos in parallel Anoxic Tank of mild steel epoxy coated with surface area of media 500 sqm/ Cum percentage of carrier fill 20%, HRT 230 min Volume of each reactor required 2.5 Cum (depth excluding 0.2 m free board and 0.3 m air grid).

-

-

-

... More
(v) 02 Nos Air compressor of capacity 50 Cum/ Hr (Air required for equilization tank , air required for sludge holding tank , Air Required for MBBR A1 , Air Required for MBBR B1 , Air Required for MBBR A2 and air required for MBBR B2 cycling timer to be provided for switching between compressors. Vendor have to be provide provision of blowing hot air using compressor in winters as per note given below. (w)1 No. Batch Type Centrifuge of capacity 5.0 kg/batch having Mild steel construction of basket size 300 x 240 mm (x) 1 Lot of interconnecting piping and valves for all units with MS ‘B’ Class pipe of STP.

-

-

-

... More
(y) 1 No. Electrical Distribution Board having controls of STP Operation as per specification mentioned here under: (i) Single Incomer, Non-Compartmentalized non draw out type, Fuseless type, Single front, Top entry, CRCA, RAL7032, Free standing, Floor mounted Panel Make: Fabricated panel from STP OEM Approved vendor. (ii) Main Busbar: Aluminium, (iii) Control Busbar: Copper (iv) Earth Busbar: 50x10MM Al (H), 25x10MM Al (V) (v) Fault level: 50kA for 1 sec Switch gear of Make: Siemens/ABB VFD of Make: ABB/Siemens/Danfoss (vi) Incomer (Suitable connected load to be designed by the tenderer duly vetted by any IIT/NIT and approved by Accepting Officer): MCCB (3P, TOLR, with U/V) MFM with RS485 communication. (vii) No space heater with thermostat, Illumination Lamp and Door limit Switch to be provided. (viii) Outgoing Feeders(3 phase): MPCB + Contactor Note:- The capacity and quantity of outgoing feeders/ switch gear has to be designed by the tenderer as per their specification.

-

-

-

... More
(B) Power/Control Cable & termination Accessories (a)Power Cables: (i) 3 Core, XLPE / PVC insulation, Armoured, Up to 6 Sq.mm Cu conductor cable (ii) Above 6Sq.mm Al conductor cable is to be provided. (b)Control Cables: (i) 4 Core, XLPE / PVC insulation, Armoured, 1.5 Sq.mm Cu conductor cable is to be provided.- Make of (cables-Polycab/Havells/Finolex (c)Termination Accessories (i) Double compression Ni plated brass glands with earth strips to be provided (ii) Non insulated Al/Cu Lugs of suitable conductor size are to be provided (C) Trays with tray supports (a) Tray material - Hot dipped GI Cable Trays Make: IEI Approved vendor. (b) Types of cable tray - Ladder and perforated type with coupler plates and joining accessories (c) Minimum Sizes to be provided - 2mm thick 600mm(W)X2500mm(L)X50mm(H) - Ladder 300mm(W)X2500mm(L)X50mm(H) - Ladder 450mm(W)X2500mm(L)X75mm(H) – Ladder 150mm(W)X2500mm(L)X50mm(H) - Ladder 100mm(W)X2500mm(L)X50mm(H) - Perforated 50mm(W)X2500mm(L)X50mm(H) - Perforated Hot dipped galvanised iron tray supports '(D) LBPS (a) Make: As approved by Accepting Officer. (b) For manual operation of drives Enclosure - CRCA , MS powder coated with RAL 7032 paint shade, IP65 protection For 3 Phase drives - LPBS with Start/Stop PB with Push release type PB and mushroom head Stop PB with key with 1 NO+1NC contacts for each PB, For 1 Phase drives- Plug and socket

-

-

-

... More
(E) Above ground Earthing (a) As per IS3043- Size is based on short circuit capacity of 50kA for 1sec (b)Cross section of earth strips or wires of suitable sized and body earthing E&I equipment are to be provided. GI strip will be provided as MOC for earthing. (i) 1 Lot of Interconnecting cabling and cable tray for all units of STP. (ii) 1 Lot of Level Switches for Raw Water Tank (RWT) and Clarified Water Tank (CWT) (F)Shed for STP Plant as per manufacturer's recommendations . (G) All interconnecting piping & valves of all units of STP. (H) For movement suitable path beween various units of STP .

-

-

-

... More
NOTES : Rates deemed to include cost of following:- (i) 1 Lot of foundation for Pumps, Blowers and other equipments as required in PCC and starters. (ii) Suitable Temperature control measure insulation of pipeline and heating arrangement shall be adopted for winter season upto (-) 10 degree celcius at altitude of 1600 mtr / Extra bacterial culture suitable for winter temperature shall be mixed in the MBBR chamber for multiplying the bacteria. The culture should maintain the pH of sewage in the neutral range. (iii) Contractor has to submit drawing & technical specification duly vetted by NIT/IIT and approved by Accepting officer before commencement of work. (iv) Contractor has to submit drawing & technical specification of LT Paner before placing order for approval of GE. (v) Rates also included pre painted galvalume aluminium zinc coating GI bassed corrugated steel sheet 0.50mm thick with mild steel framed structure including two coats of synthetic enamel paint over a coat of red oxide primer including necessary welding, base plate, gusset plate, excavation, RCC work in foundation. Foundation design shall be based on load bearing capacity of soil at a depth of 1.5M from GL covering from bar screen chamber to activated carbon filter (ACF) having both side slope of 1 : 3 with clear height 3 Mtr on all sides and 1.50m clear space on all sides from civil structure 60 mm thick machine pressed precast concerete interlocking paver block any slope and size M-35 Grade over 50mm thick sand cushion to be laid at 1.5M clear space on all sides from Civil structure. The structure will be designed for loading as per IS 800, the design will be get approved by Accepting Officer before work commenced. No side cladding is required.

-

-

-

... More
INTERNAL ELECTRIFICATION WORKS

-

-

-

... More
Supply and fixing LED tube light fitting 4 feet long , 18 watt 220 V AC,AC Box type with driver holder and LED light including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including hanging by chain or hook fitted on two round blocks /fixing arrangement on truss/roof/wall complete all as specified and directed .

39

-

-

... More
Supply and fix heavy duty exhaust fan of size 300 mm sweep, AC single phase 220 volts 50HZ, incl. louver shutter, XPM jaali, grounting etc. (ISI marked) incld connection wire of 1.50Sqmm three core from ceiling rose to exhaust fan in flexible conduit complete all as specified and directed.

8

-

-

... More
Supply and fixing sub main wiring with two runs of single core FRLS PVC insulated multi-stranded copper conductor 4 Sqmm and one run of 4 Sqmm for earth continuous earth wire including suitable PVC conduit not less than 20mm dia with all accessories medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 4 sqmm, one runs of earth wire 4 sqmm & PVC conduit will be considered as one unit.

50

-

-

... More
Supply and fixing ceiling fans AC single phase 230V/240V 50 Hz of size 1200mm sweep BEE 5 star rated , aluminium body, copper wound with fan blade aluminium, three core copper wire lead, electronic type regulator (rotary type 360 degree) (ISI marked) complete alll as specified and directed.

4

-

-

... More
Supply and fixing MCB SPN 240 Volt, 50Hz , 10 KA, 'C' series of rating 06 to 32 Amp confirming to IS/IEC 60898-1 complete all as specified.

3

-

-

... More
Supply and fixing MCB SP 240 Volt, 50Hz , 10 KA, 'C' series of rating 06 to 32 Amp confirming to IS/IEC 60947-2 complete all as specified.

14

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6 mm thick buried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire protected by provn of GI light grade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregates ) with 40mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4kg/Sqm) and frame of angle iron 25x 25x3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 5 of SSR -2010 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and protection pipe 15 mm bore medium grade GI light grade 20 mm bore watering pipe. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.

3

-

-

... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, GI bracket of size 40mm dia pipe with GI wall clamps, nuts and bolts incld connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

6

-

-

... More
INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Supplying and fixing angle valve cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed complete all as specified and directed.

10

-

-

... More
Supplying and fixing Health faucet (ABS body) mild steel chromium plated shitable for 15 mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.

2

-

-

... More
PANELS FOR SEWAGE DISPOSAL WORKS

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 02 Nos. automatic non clog submersible pump 3 HP, 02 Nos. motorized butterfly valve, 02 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 900(H) X 900(W) X 300(D) mm fabricated from 2 mm CRCA Sheet complete all as specified and directed. (Location :- 10, 2188, 2664 A ) The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based

5

-

-

... More
Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module. (ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications

-

-

-

... More
('iii) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (iv) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (v) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays. ( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT)

-

-

-

... More
(vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (viii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB) 3HP DOL Starter 02 Nos (a) MCB 16 A TP- 2NO. (b) Contactor 9 A TP - 2 NO. (c) Over Load Relay 4.5-7.5 A - 2 NO. (d) Digital Ammeter- 2 NO.(e) Push Button Start/Stop - 4 NOS. (f) Indicating Light ON/OFF/TRIP- 6 NOS.(g) Single Phase Preventer- 2 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 02 Nos. automatic non clog submersible pump 5 HP, 02 Nos. motorized butterfly valve, 02 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 900(H) X 900(W) X 300(D) mm fabricated from 2 mm CRCA Sheet. (Location :- Chief Office) all as specified and directed.

2

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module. (ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX

-

-

-

... More
CONTACT (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications(iv) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (v) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (vi) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays ( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT)

-

-

-

... More
(vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (viii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB) 5HP DOL Starter 02 Nos (Item mention below for 01 No) (a) MCB 20 A TP- 1 NO. (b) Contactor 18 A TP - 1 NO. (c) Over Load Relay 6-10 A - 1 NO. (d) Digital Ammeter- 1 NO (e) Push Button Start/Stop - 2 NOS. (f) Indicating Light ON/OFF/TRIP- 3 NOS (g) Single Phase Preventer- 1 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation)

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 02 Nos. automatic non clog submersible pump 10 HP, 02 Nos. motorized butterfly valve, 02 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 900(H) X 900(W) X 300(D) mm fabricated from 2 mm CRCA Sheet. (Location :- 415) all as specified and as directed.

2

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel.

-

-

-

... More
(i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module. (ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications '(iii) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (iv) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (v) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT)

-

-

-

... More
(vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (viii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB) 10HP Star Delta Starter 02 Nos (ix) MCB 32 A TP- 2 NO. (x) Contactor 18 A TP - 4 NO. (xi) Contactor 12 A TP - 2 NO. (xii) Over Load Relay 6-10 A - 2 NO.Star Delta Timer - 2 NO. (xiii) Digital Ammeter- 2 NO. (xiv) Push Button Start/Stop - 4 NOS. (xv) Indicating Light ON/OFF/TRIP- 6 NOS. (xvi) Single Phase Preventer- 2 NO.CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation)

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 02 Nos. automatic non clog submersible pump 20 HP, 02 Nos. motorized butterfly valve, 02 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 900(H) X 900(W) X 300(D) mm fabricated from 2 mm CRCA Sheet. (Location :- 2752, 576 ) all as specified and directed.

2

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.

-

-

-

... More
(ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications (iii) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (iv) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (v) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT) (vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (viii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB)

-

-

-

... More
20HP Star Delta Starter (a) MCB 60 A TP-2 NO. (b) Contactor 32 A TP - 4 NO (c) Contactor 22 A TP - 2 NO (d) Over Load Relay 14-23 A - 2 NO. (e) Star Delta Timer - 2 NO. (f) Digital Ammeter- 2 NO. (g) Push Button Start/Stop - 4 NOS. (h) Indicating Light ON/OFF/TRIP- 6 NOS. (j) Single Phase Preventer- 1 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 02 Nos. automatic non clog submersible pump 30 HP, 02 Nos. motorized butterfly valve, 02 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 900(H) X 900(W) X 300(D) mm fabricated from 2 mm CRCA Sheet. (Location :- MPS Center, 1546 ) all as specified and directed.

4

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.

-

-

-

... More
(ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications (iii) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (iv) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (v) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT) (vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (vii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB)

-

-

-

... More
30HP Star Delta Starter 02 Nos (a) MCCB 100 A TP- 2 NO. (b) Contactor 40 A TP - 4 NO (c) Contactor 32 A TP - 2 NO. (d) Over Load Relay 20-33 A - 2 NO. (e) Star Delta Timer - 2 NO.(f) Digital Ammeter- 2 NO. (f) Push Button Start/Stop - 4 NOS. (g) Indicating Light ON/OFF/TRIP- 6 NOS. (i) Single Phase Preventer- 2 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 03 Nos. automatic non clog submersible pump 30 HP-02 No & 20 HP- 01 Nos. motorized butterfly valve, 03 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 1200(H) X 1200(W) X 300(D) mm fabricated from 2 mm CRCA Sheet all as specified and directed.

1

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.

-

-

-

... More
(ii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications (iii) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (iv) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (v) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT) (vi) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (vii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (viii) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB)

-

-

-

... More
As per requirement (Make:- Schneider/ ESBEE/ABB) 30HP Star Delta Starter -02 Nos (a) MCCB 100 A TP- 2 NO. (b) Contactor 40 A TP - 4 NO. (c) Contactor 32 A TP - 2 NO. (d) Over Load Relay 20-33 A - 2 NO (e) Star Delta Timer -2 NO. (f) Digital Ammeter- 2 NO. (g) Push Button Start/Stop - 4 NOS. (h) Indicating Light ON/OFF/TRIP-6 NOS (i) Single Phase Preventer- 2 NO.

-

-

-

... More
20HP Star Delta Starter -01 No (a) MCB 60 A TP- 1 NO. (b) Contactor 32 A TP - 2 NO. (c) Contactor 22 A TP - 1 NO. (d) Over Load Relay 14-23 A - 1 NO. (e) Star Delta Timer - 1 NO. (f) Digital Ammeter- 1 NO. (g) Push Button Start/Stop - 2 NOS. (h) Indicating Light ON/OFF/TRIP- 3 NOS. (j) Single Phase Preventer- 1 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation)

-

-

-

... More
Supply, Installation Testing & Commissioning of Indoor type PLC ( Programmable Logic Controller) based Pump and Valve Automation, Protection Panel suitable for control and monitoring 03 Nos. automatic non clog submersible pump 30 HP 01 No & 35 HP-02 Nos, 02 Nos. motorized butterfly valve, 03 Nos. pressure transmitter, 01 Nos. ultrasonic level transmitter. The panel should be of minimum size 1200(H) X 1200(W) X 300(D) mm fabricated from 2 mm CRCA Sheet all as specified and directed.

1

-

-

... More
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Automatic Pump On/Off (c) Automatic Operation of Motor Actuated Butterfly Valves (d) Automatic Toggling of Pumps ( if secondary pump exists) (e) Auto Change Over In Case of Pump Failure ( if secondary pump exists) (f) Single Phasing Prevention (g) Manual Mode Operation (all connected sub systems including all valves in STP and pumps) from the PLC based Control Panel. (i) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom programming as per process requirement (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module.

-

-

-

... More
(ii) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/ABB/GE Automation/PHOENIX CONTACT) (a). 1 Nos. non isolated RS 485 communication port, 1 Nos. Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming Software based on IEC to facilitate building of custom build function blocks. (d). Industrial Grade Processor. (e). Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module. (iii) 01 no. HMI - 7" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ ABB/GE AUTOMATION/PHOENIX CONTACT) (a). 01 nos. RS 485 and 01 no. USB port (b). Serial multilink, USB downloading port (c). Support external data storage on a USB memory stick for storing production data and backing up applications (iv) 01 no. SMPS of 5/10A rating as suitable according to panel design. (Make: SCHNEIDER / SIEMENS/ PHOENIX CONTACT / OMRON) (v) Suitable no. of interposing relays of 220VAC & 24 VDC coil rating and 6 A contact rating. (Make: OEN / OMRON / ALLEN BRADLEY/PHOENIX CONTACT) (vi) Suitable no. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays.( SCHNEIDER / SIEMENS/ ABB/PHOENIX CONTACT)

-

-

-

... More
(vii) MCB rating 32A, 10A, 6A. (Make:- Legrand/ Schneider/ABB) (viii) Illuminiated push button & indicator lamp (Make:- Schneider/ESBEE/ABB) (ix) Selector switches, Audio visual alarm indicator:- As per requirement (Make:- Schneider/ ESBEE/ABB) 30HP Star Delta Starter (a) MCCB 100 A TP- 1 NO. (b) Contactor 40 A TP - 2 NO. (c) Contactor 32 A TP - 1 NO. (d) Over Load Relay 20-33 A - 1 NO. (e) Star Delta Timer - 1 NO (f) Digital Ammeter- 1 NO (g) Push Button Start/Stop - 2 NOS. (h) Indicating Light ON/OFF/TRIP- 3 NOS

-

-

-

... More
(i) Single Phase Preventer- 1 NO. 35HP Star Delta Starter -02 Nos (a) MCCB 100 A TP- 2 NO. (b) Contactor 50 A TP - 4 NO (c) Contactor 40 A TP - 2 NO (d) Over Load Relay 30-50 A - 2 NO. (e) Star Delta Timer - 2 NO. (f) Digital Ammeter- 2 NO. (g) Push Button Start/Stop - 4 NOS. (g) Indicating Light ON/OFF/TRIP- 6 NOS. (h) Single Phase Preventer- 2 NO. CRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ELDON / RITTAL ) Make of the PLC based panel:- (Universal Switch Gear Control Cat. No. U- 753 / PLC /220V AC or equivalent in ABB Automation/Tricolite/GE Automation)

-

-

-

... More
Supply, Installation, Testing and Commissioning of 4 pair CAT 6 UTP armoured cable for Sensors all as specified and directed. Make: D Link/ Finolex/ Polycab

305

-

-

... More
Supply only 2 Core 1.5sq.mm. PVC sheathed PVC insulated copper armoured cable all as specified and directed. Make: Havells/Polycab/Gloster

300

-

-

... More
Supply only 6 Core 1.5sq.mm. PVC sheathed PVC insulated copper armoured cable all as specified and directed. Make: Havells/Polycab/Gloster

1000

-

-

... More
Supply & Fixing wiring of starter and motor with Flat Three Core 10 sqmm PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors complete all as specified and directed. Make: Havells/ Polycab/ Anchor

150

-

-

... More
Supply & Fixing wiring of starter and motor with Flat Three Core 16 sqmm PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors complete all as specified and directed. Make: Havells/ Polycab/ Anchor

50

-

-

... More
Supply & Fixing wiring of starter and motor with Flat Three Core 25 sqmm PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors complete all as specified and directed. Make: Havells/ Polycab/ Anchor

115

-

-

... More
Supply & Fixing wiring of starter and motor with Flat Three Core 35 sqmm PVC Insulated & PVC Sheathed Industrial copper Cable for Submersible Pump Motors complete all as specified and directed. Make: Havells/ Polycab/ Anchor

50

-

-

... More
MISCELLANEOUS E/M & B/R ITEMS FOR SEWAGE DISPOSAL WORKS

-

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 200 LPM at 25 Mtr Head 3 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

8

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 350 LPM at 25 Mtr Head 3 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

2

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 500 LPM at 25 Mtr Head 5 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

4

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 800 LPM at 25 Mtr Head 10 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

2

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 1500 LPM at 25/40 Mtr Head 20 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

5

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 2000 LPM at 25/40 Mtr Head 30 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

7

-

-

... More
Supply, Fixing, testing and commissioning Non clog vertical Submersible Pumping Set 2500 LPM at 25/40 Mtr Head 35 HP CI impeller and cutter non clog to pass 40 mm size particles pumping sets with CI impeller, CI casting SS shaft & SS Sleeve minimum discharge capacity as above coupled with high quality motor 3 phase 415 volts 50 Hz 1450 RPM seal with two indepedent mechanical seal and optional pencil electrode for sealing chamber control including foundation as per manufacturer design and electric connection with suitable size of cable and all necessary conection for suction and delivery and all holding arrangements complete all as specified and directed. Pump set shall be mounted on a metal base frame incl installation with guide rail and lifting chain complete all as specified and directed.

2

-

-

... More
Supplying, laying, jointing , testing ductile iron (DI) pipes of 100mm size, centrifugally cast, class K-9, in any length laid in trenches complete all as specified and directed. NOTES:- The unit quoted rate shall include:- (a) Short pieces of any length as required at Site. (b) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. (c) Earth work, PCC, Titan joints and all CI fittings shall be measured and paid separately.

461

-

-

... More
Supplying, laying, jointing , testing ductile iron (DI) pipes of 150mm size, centrifugally cast, class K-9, in any length laid in trenches complete all as specified and directed. NOTES:- The unit quoted rate shall include:- (a) Short pieces of any length as required at Site. (b) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. (c) Earth work, PCC, Titan joints and all CI fittings shall be measured and paid separately.

580

-

-

... More
Supplying, laying, jointing , testing ductile iron (DI) pipes of 200mm size, centrifugally cast, class K-9, in any length laid in trenches complete all as specified and directed. NOTES:- The unit quoted rate shall include:- (a) Short pieces of any length as required at Site. (b) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. (c) Earth work, PCC, Titan joints and all CI fittings shall be measured and paid separately.

470

-

-

... More
Supplying, laying, jointing , testing ductile iron (DI) pipes of 250mm size, centrifugally cast, class K-9, in any length laid in trenches complete all as specified and directed. NOTES:- The unit quoted rate shall include:- (a) Short pieces of any length as required at Site. (b) Pipes shall be laid in trenches/over RCC pillars/under bridges/culverts/roads etc. (c) Earth work, PCC, Titan joints and all CI fittings shall be measured and paid separately.

910

-

-

... More
Supply, installation, testing, and commissioning of Pressure Transmitter with proper wiring including necessary power pack for supply of DC :- Power supply: 10-36 V DC Enclosure: whether proof IP 65 Process temperature: -30 to 120 Celsius Accuracy: 0.25 % complete all as specified and directed. Make: Indfos/Danfoss/ Endress+Hauser

30

-

-

... More
Supply, Installation,Testing and Commissioning of Ultrasonic Level Transmitter at Sump for measurement of level with following specification:- Range : 0-8 metres Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA , 0-10V DC complete all as specified and directed. Make: Banner / Nivelco / Siemens

14

-

-

... More
Supply and fix cast iron sluice valve flanged ends heavy duty class PN 1.6 suitable for 250 mm (10") dia pipe including 6mm thick 2 Nos rubber insertion ring with GI nuts, bolts and washers of suitable size complete all as specified and directed.

4

-

-

... More
Supply and fix cast iron non return valve flanged ends heavy duty suitable for 250 mm dia pipe including 6mm thick 2 Nos rubber insertion ring with GI nuts, bolts and washers of suitable size complete all as specified and directed.

2

-

-

... More
Supply and fix cast iron non return valve flanged ends heavy duty suitable for 300 mm dia pipe including 6mm thick 2 Nos rubber insertion ring with GI nuts, bolts and washers of suitable size complete all as specified and directed.

1

-

-

... More
Supply & fixing BOD incubutor suitable for BOD method for monitoring the waste water effluent. Incubutor should be castor wheel mounted cabinet , double walled inner chamber made of aluminium / SS outer chamber and outer chamber made of MS with powder coating , chamber volume 90 L 70 mm glass wool insulated 5-105 degree celcius all as specified and directed.

1

-

-

... More
Supply Only Magnese sulphate for BOD testing all as specified and directed.

5

-

-

... More
Supply Only alkali iodide zinc for BOD testing all as specified and directed.

5

-

-

... More
Supply Only H2SO4 Acid for BOD testing all as specified and directed.

5

-

-

... More
Supply Only 0.025 N Sodium thiosulphate for BOD testing all as specified and directed.

5

-

-

... More
Supply Only starch solution for BOD testing all as specified and directed.

5

-

-

... More
Supply, install & testing biochemical oxygen demand tester measurement range 0-1000 mg/L simultaneously determination of the number of sample 6 or 8 channels display BOD5 value working at cultural temp 20 degree C + 1 degree C 220V 50 Hz all as specified and directed.

1

-

-

... More
Supply & fixing integrated type sewage flow meter of suitable size with PTFE lining flanged 150/200 mm made of carbon steel working at 24V DC or 220 V Ac Signal Output 4 to 20 mA RS 485 communication all as specified and directed.

3

-

-

... More
M&L for flush point by using GI pipe medium grade, valves & nozzle in syphon design for maintaining adequate pressure in sewage line to keep the sufficient velocity as per CPHEECO manual for STP using appropriate size of pipe not less than 40mm dia and, fittings etc complete all as specified and directed by Engr-in-charge. Notes: (i) Design of flushing point to be submitted by the contractor duly approved by OEM of STP before execution of site. (ii) Rate includes necessary Earth, PCC , blacksmith work and any item reqd for properfunctioning of flush pont system.

17

-

-

... More
Material & Labour for Reinforced cement concrete pipes class NP3 pipes 400 mm internal dia, with and including collars, laid in trenches and jointed complete all as specified and as directed.

548

-

-

... More
Material & Labour for Crossing of Jammu-Srinagar National Highway for minimum length of 30 metre by Trenchless Technology comprising of construction of Driving pits and Receiving Pits including Tunneling with any micro tunneling / horizontal directional method, Jack Pushing of 250mm dia MS casing pipe and MS Carrier pipes coated with 750 micron polyurethane for protection against corrosion, placing of spacers etc. complete in all respects including restoration at the driving end and receiving end to its original condition complete all as specified and as directed.

1

-

-

... More
Material & Labour for Crossing of Jammu-Srinagar National Highway for minimum length of 30 metre by Trenchless Technology comprising of construction of Driving pits and Receiving Pits including Tunneling with any micro tunneling / horizontal directional method, Jack Pushing of 300mm dia MS casing pipe and MS Carrier pipes coated with 750 micron polyurethane for protection against corrosion, placing of spacers etc. complete in all respects including restoration at the driving end and receiving end to its original condition complete all as specified and as directed.

1

-

-

... More
Material & Labour for Crossing of Jammu-Srinagar National Highway for minimum lenght of 30 metre by Trenchless Technology comprising of construction of Driving pits and Receiving Pits including Tunneling with any micro tunneling / horizontal directional method, Jack Pushing of 150 mm dia DI K-9 pipe from Old CE office to New CE office, placing of spacers etc. complete in all respects including restoration at the driving end and receiving end to its original condition complete all as specified and as directed.

1

-

-

... More
Material & Labour for LLDPE septic drainage tank with upflow filter including media designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 20 users LLDPE tank (commercial grade) as per manufacturer's instructions of Make sintex/polywell/Rotex/Polycon, complete all as specified and as directed.

25

-

-

... More
Material & Labour for cutting of road as required for laying RCC pipe line including repair/make good with filling of earth, boulders, WBM, BM etc. with top surface finished with 30mm thick ready mixed patch filter, complete all as specified and as directed.

150

-

-

... More
Material & Labour for filling of abandoned existing Septic tanks and Soakage Pits of any size by Brick bats/stone boulders of any size, complete all as specified and as directed.

250

-

-

... More
Material & Labour for filling of abandoned existing manholes of any size by Brick bats/stone boulders of any size, complete all as specified and as directed.

300

-

-

... More
Material & Labour for RCC precast Manhole cover with frame of steel fiber reinforced concrete (SFRC) of size 560mm dia heavy duty ISI marked complete all as specified and as directed.

1690

-

-

... More
ROAD / PATH / CULVERTS

-

-

-

... More
Material and labour for Road marking with reflective thermoplastic screed 2.5mm thick using thermoplastic road marking paint of approved brand(white or yellow) including admixture layer of glass beads confirming to BS-6088 and most specification by using automatic mechanical road marking machine including cleaning of all dirt, scales, oil, grease and foreign material etc; complete all as specified and directed. Makes : Asian Paints/Shivalik Prismo India Pvt ltd/ Reliance

100

-

-

... More
Material and labour for Uni/dual/tri-directional acrylic plastic reflectors cat eye of ABS material having size 100mmx100mmx20mm with celluler lense design alloy to continue functioning even after impact/damage in white/red/yellow colour fixed with special hot melt bitumen adhesive to road complete all as specified and as directed.

25

-

-

... More
Material and labour for delinator made of iron pipe of internal dia 70mm, height of 90cm and thickness of 4mm with four strips of 2cm width around the pipe grouted in PCC 1:2:4 type B1 block of size 200mmX200mmX300mm including necessary excavation and removal of soil complete all as specified and as directed. Make : Gogia Plastics Cat part No GPD - 933 or equivalent

40

-

-

... More
EXTERNAL WATER SUPPLY WORKS

-

-

-

... More
Material and labour for cutting the existing GI pipe in position of and including insertion of new tee 50x50x25 mm in pipe of sizes 50 mm dia complete all as specified and directed.

3

-

-

... More
Material and labour for Taking out existing GI/CI/MS pipes of any size up to 150 mm bore for reuse and shifting to new place as per requirement incl excavation, fitting & fixtures, PCC complete all as specified and directed.

200

-

-

... More
EXTERNAL ELECTRIC SUPPLY WORKS

-

-

-

... More
M & L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note: (i) Measurement shall be taken only after punning down sand cushioning.

170

-

-

... More
Steel tubular swaged poles complete with CI base plate , finial taper plug, bolts, nuts & screws as specified type 410 SP- 55 (11 metres long) including two coat of black bituminous paint internally throughout and externally upto embedded portion and including applying two coats of synthetic enamel paint over a coat of red oxide primer with black and yellow strip of 30 cm each upto 1.5 m height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after errection in position including preparation of surface, complete all as specified and directed. ( Note:- Necessary earth work , PCC coping will be measured and paid for separately under respective item.

6

-

-

... More
M&L for earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,(No 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board or junction box all as shown in electrical plate No. 3 of SSR - 2009 (Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (medium grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC cover duly reinforced with XPM (weight not less than 3 kg /sqm ) & CI frame etc , provision of test point , connecting to test point and testing on completion etc, complete all as specified and directed. Note: The quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth wire and protection pipe and watering pipe.

3

-

-

... More
M&L for earthing complete with galvanised steel earth plate of size 60cmx60cmx6mm thick, surrounded by mixture of charcoal and salt in alternate layers burried directly in ground, earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to equipment by using GI strips of size 32x6mm as earthing lead by means of bolts,nuts,checknut & washers of galvanised iron all as shown in elect plate No.5 of MES schedule and connected to earthing test point all as specified and directed including earth pit of size 30cmx30cmx45cm made of PCC 1:3:6 and PCC 1:2:4 cover, funnel, GI tubing etc. & testing on completion including necessary excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (medium grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh, lugs PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Design mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) & CI frame etc , provision of test point , connecting to test point and testing on completion etc, complete all as specified. complete all as specified and directed. Note: The quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth strip, protection pipe and watering pipe.

70

-

-

... More
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete incl Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 25mm x 4mm and 04 sets of nuts,bolts and washers and junction box of mininmum size 168 x 253 x 115 outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with four aluminium strips 60 Amps capacity insulated with insulators, incl colour coding , including control wiring from bus bar to MCB (b) MCB SPN 6 Amps - 01 No. incl copper connection from junction box complete, all as specified and as directed.

10

-

-

... More
Supplying, transporting to site, erecting and fixing in poistion, 9 mtr long and type 410 SP-31 steel tubular swaged and welded poles, IS-2731 marked with CI base plate pole cap/ finial, taper plug, bolts, nuts, washers etc complete, including painting outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and providing 30 cm wide alternate black and yellow strips upto 1.50m from top of coping complete all as specified and directed. Note:- Excavation, Earth work,PCC to be measured & paid for separately.

10

-

-

... More
Supplying and fixing Single Core (phase, neutral and earth) copper conductor (Flexible) FRLS PVC insulated industrial Cables (Unsheathed) 1100 Volts Size 1.5 Sqmm Conforming to IS: 694 complete all as specified and directed. Note: The 3 run of copper conductor shall be measured as one unit

50

-

-

... More
Material & labour switch air break gang operated out door HT 11 KV triple pole mechanically operated mounted on HT insulators(12 Nos insulators)type and MS galvanised steel frame with operating mechanism worked from ground level including operating rod of GI pipe of 25 mm bore with handle for current rating 400 Amps, 11000 volts complete with locking arrangements MS clamps, bolts, nuts and washers etc. including fuse barrels of required capacity to suite the load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.

2

-

-

... More
Material & labour for switch air break gang operated out door HT 11 KV triple pole mechanically operated mounted on HT insulators(12 Nos insulators)type and MS galvanised steel frame with operating mechanism worked from ground level including operating rod of GI pipe of 25 mm bore with handle for current rating 200 Amps, 11000 volts complete with locking arrangements MS clamps, bolts, nuts and washers etc. including fuse barrels of required capacity to suite the load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed.

2

-

-

... More
Supplying and fixing Lightening arrestor gapless metal oxide type heavy duty single pole suitable for rated system voltage or 12 KV and working rated arrester of 9kV with metal discharge current 10 KA complete all as specified and directed.

2

-

-

... More
Taking out existing LT/HT Pole and connected cable of any size for reuse after dismantling all electric connections and shifting to new place as per requirement incl excavation, fitting & fixtures, PCC and making good all electric connection with cable joint and earth level complete all as specified and directed.

40

-

-

... More
Taking out existing LT/HT underground cable any size for reuse after dismantling all electric connections and shifting to new place as per requirement incl excavation, fitting & fixtures, PCC, bricks, sand and making good all electric connection with cable joint and earth level complete all as specified and directed.

200

-

-

... More
Material & labour for Cable route indicator 100mm dia, 5mm thick duly engraved with "HT cables 11000 volts" having CI rod 10mm dia, 50 to 70 cm long, duly welded to round plate complete with PCC block of PCC 1:3:6 type C2 using 40mm graded stone aggregate of size 30 cm x 30 cm x 30cm in ground complete all as specified and directed.

10

-

-

... More
Material & labour for Cable route indicator 100mm dia, 5mm thick duly engraved with "LT cables 1100 volts" having CI rod 10mm dia, 50 to 70 cm long, duly welded to round plate complete with PCC block of PCC 1:3:6 type C2 using 40mm graded stone aggregate of size 30 cm x 30 cm x 30cm in ground complete all as specified and directed.

40

-

-

... More
Material & labour for road cutting and making good to match existing surface with PCC 1:2:4 complete all as specified and directed.

4

-

-

... More
Supply, installation, commissioning and testing of Servo Voltage Stablizer fully automactic micro processor based control card of capacity 150 KVA, three phase oil cooled, indoor type and designed for input variation between 300V to 500V, output voltage stabilized at 415 Volts with accuracy of +1% and speed of voltage correction should not be less than 8V/Sec, input frequency 47 to 53 Hz, having facility to auto and manual operarion, no load loss should be less than 0.5% operating temp -15°C to 45°C above ambient and suitable to operate wtih unbalanced load including initial oil filling up to appropriate level with new transformer oil and having all standard accessories (i.e Volt meter, Amp meter, Set of CTs of appropriate ratio, Selector switch, sufficiant Nos of LED indicator lamps, togal switch for auto and mannual mode, push buttons for voltage lower/ raise and indication for bypass arrengement etc) complete all as specified and directed with and including following additional features:- (a) High and low voltage cut-off system. (b) Single phase prevention and reserve phase protection system. (c) Over load and short circuit protection by provided MCCB of suitable Amps and KA rating, 4 pole having adjustable thermal and adjustable magnetic setting. (d) Incoming control by providing MCCB of suitable Amps and KA rating, 4 pole with adjustable thermal megnatic setting. (e) By-pass arrangement by providing ON Load Change over switch, 4 Pole of suitable rating.

1

-

-

... More
Supply and fixing on load Change over Switch in and incl sheet metal enclosure cubical type 4 pole of rating 400 Amps, confirming to IS-13947 (Part 3) with rotary handles complete all as specified and directed.. Make: Havells / L&T/ Schneider/ Siemens

1

-

-

... More
Schedule 'A' Part-XV (DG SET WORKS)

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing classG2 incl sound reducing canopy (sound level not more than 75 dbat distance 1 mtr) 14 guage as per guideline issued by Central pollution control board , 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 5 KVA after considering derating factor confirming to IS-1601 at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+) 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa Self starter with batteries, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 5 kVA all as per as per IS: 13364 and up to date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed .

3

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 6.25 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of powder coated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 5 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -5 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person. (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing classG2 incl sound reducing canopy (sound level not more than 75 dbat distance 1 mtr) 14 guage as per guideline issued by Central pollution control board , 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 15 KVA after considering derating factor confirming to IS-1601 at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+) 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa Electric starter motor with batteries, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 15 kVA all as per as per IS: 13364 and up to date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed

1

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 19 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of powder coated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 15 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -15 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person. (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing classG2 incl sound reducing canopy (sound level not more than 75 db at distance 1 mtr) 14 guage as per guideline issued by Central pollution control board , 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 40 KVA after considering derating factor confirming to IS-1601 at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+) 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa sel starter with batteries, turbocharger water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 40 kVA all as per as per IS: 13364 and up to date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed

3

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 50 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of powder coated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 40 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -40 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person. (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing classG2 incl sound reducing canopy (sound level not more than 75 dbat distance 1 mtr) 14 guage as per guideline issued by Ministry of Environment & forest notification, & Central pollution control board , 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 75 KVA after considering derating factor confirming to IS-1601 at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+) 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa Electric starter motor with batteries, turbocharger water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 75 kVA all as per as per IS: 13364 and up to date amendments with H class insulation self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed

1

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 91 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated out of powder coated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement provided external to the canopy. The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 75 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -75 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person. (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing class G2 incl sound reducing canopy (sound level not more than 75 db at 1 mtr ) 14 guage as per guideline issued by Central pollution control board 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 20 KVA after considering derating factor at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa self starter with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 20 kVA all as per as per IS: 13364 and up to date amendments with H class insulation having , self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed

1

-

-

... More
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 25 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement . The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 20 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -20 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute.5. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person. (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE

-

-

-

... More
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing class G2 incl sound reducing canopy (sound level not more than 75 db at a distance of 1 mtr) 14 guage as per guideline issued by Central pollution control board 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting on main failure control panel suitable for giving an output of 160 KVA after considering derating factor at 1600 metre altitude above mean sea level and capable of operating between temperature range (-20) degree C to (+) 40 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other with flexible coupling mounted on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of AMF panel with auto change main to generator and viceversa Self starter with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 160 kVA all as per as per IS: 13364 and up to date amendments with H class insulation, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole all as specified and directed

1

-

-

... More
(b) Engine : Water cooled Diesel Engine (CPCB Norms Compliance) developing Min 200 BHP or as recommended by the manufacturer for 1600 mtr altitude having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters, cold start kit etc all as specified and directed. (c) Canopy : Canopy enclosure shall be powder coated and fabricated after passing through seven tank processes16 SWG CRCA MS sheet and Lockable doors should be provided in Canopy with lockable fuel filling arrangement . The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. Absorption type non‐resistance Residential Silencer shall be provided to suppress exhaust noise from the engine.

-

-

-

... More
(d) Alignment and Fuel Tank :Alternator and Engine aligned on a common  14 SWG CRCA MS  base frame complete with MS Fuel Tank, fabricated out of 16 SWG CRCA MS Sheet and is part of base frame. (e) Generating Panel :- DG set should consist of AMF Generating Panel auto starting on main failure mounted as per manufacturer. (f) Maintenance spares:- (i) Fuel filter element-02 Nos. (ii) Oil filter element-03 Nos. (iii) Element air cleaner outer-06 Nos (iv) Element air cleaner inner-06 Nos (v) 'V'Belt -02 Nos (vi) Filter lubricant oil bypass-02 Nos. (g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 160 KVA DG set as per CPCB Norms.

-

-

-

... More
Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 1600 meters altitute -160 kVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii) PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv) Engine shall be designed keeping in consideration of de-rating factor for 1600 meters altitute (vi) DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 30 Minutes, 25% of Rated load = 1 Hr 50% of Rated load = 1 Hr, 75% of Rated load = 1 Hr, Full load = 2 Hr, 110% on rated Load = 1 Hr, Full load = 2 Hr,75% of Rated load = 1 Hr, 50% of Rated load = 1 Hr, 25% of Rated load = 1 Hr, No Load = 30 Minutes (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE (viii)Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person.

-

-

-

... More
ELECTRIC PANEL WORKS

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet 3.15 mm thickness for outer compartment & 1.6mm for inner compartment of suitable size with 450 mm depth with base ISMB 100 mm and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 400 amps, 415 Volts 50 KA (Incoming) - 01 No (b) MCCB 3 pole,200 Amps, 415 Volts 35 KA (outgoing) - 01 Nos (c) MCCB 3 pole, 160 Amps, 415 Volts, 25 KA (outgoing) - 02 Nos (d) MCCB 3 pole, 63 Amps, 415 Volts, 25 KA (outgoing) - 01 Nos (e) Aluminium four strip busbar rated 600 Amp duly insulated with adhesive tape RYB & Black

1

-

-

... More
(f) Digital voltmeter 0-500 volt, with selector switch-01 No (g) Ammeter with CT and selector switch rating from 100/5 -01 No (h) LED indicator lamp-03 Nos (j) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement . Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 160 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,63 Amps, 415 Volts 25 KA (outgoing) - 03 Nos (c) Aluminium four strip busbar rated 250 Amp duly insulated with adhesive tape RYB & Black

2

-

-

... More
(d) Digital voltmeter 0-500 volt, with selector switch-01 No (e) Ammeter with CT and selector switch rating from 100/5 -01 No (f) LED indicator lamp-03 Nos (g) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement . Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 125 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,63 Amps, 415 Volts 25 KA (outgoing) - 02 Nos (c) Aluminium four strip busbar rated 200 Amp duly insulated with adhesive tape RYB & Black

2

-

-

... More
(d) Digital voltmeter 0-500 volt, with selector switch-01 No (e) Ammeter with CT and selector switch rating from 100/5 -01 No (f) LED indicator lamp-03 Nos (g) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement. Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 100 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,40 Amps, 415 Volts 25 KA (outgoing) - 02 Nos (c) Aluminium four strip busbar rated 160 Amp duly insulated with adhesive tape RYB & Black

2

-

-

... More
(d) Digital voltmeter 0-500 volt, with selector switch-01 No (e) Ammeter with CT and selector switch rating from 100/5 -01 No (f) LED indicator lamp-03 Nos (g) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement. Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 40 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,16 Amps, 415 Volts 16 KA (outgoing) - 02 Nos (c) Aluminium four strip busbar rated 200 Amp duly insulated with adhesive tape RYB & Black

7

-

-

... More
(d) Digital voltmeter 0-500 volt, with selector switch-01 No (e) Ammeter with CT and selector switch rating from 100/5 -01 No (f) LED indicator lamp-03 Nos (g) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement . Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 63 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,40 Amps, 415 Volts 25 KA (outgoing) - 01 Nos (c) MCCB 4 pole,25 Amps, 415 Volts 25 KA (outgoing) - 01 Nos (d) Aluminium four strip busbar rated 100 Amp duly insulated with adhesive tape RYB & Black

1

-

-

... More
(e) Digital voltmeter 0-500 volt, with selector switch-01 No (f) Ammeter with CT and selector switch rating from 100/5 -01 No (g) LED indicator lamp-03 Nos (h) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Supply, install, test & commission CPRI approved LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet of 3.15 mm thickness for outer compartment & 1.6mm thickness for inner compartment of suitable size with 450 mm depth with base ISMB 75 mm and Angle Iron frame (50x50x6mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, & rear side incld locking arrangement. Duly painted with powder coating (7 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc. Following shall deemed to be included in the cost of panel:- (a) MCCB 4 pole 40 amps, 415 Volts 25 KA (Incoming) - 01 No (b) MCCB 4 pole,16 Amps, 415 Volts 16 KA (outgoing) - 02 Nos (c) Aluminium four strip busbar rated 100 Amp duly insulated with adhesive tape RYB & Black

1

-

-

... More
(d) Digital voltmeter 0-500 volt, with selector switch-01 No (e) Ammeter with CT and selector switch rating from 100/5 -01 No (f) LED indicator lamp-03 Nos (g) Internal wiring with suitable size single core copper conductor cable of Red, yellow, Blue and black colour including lugs, ferrule, tag etc. Notes:- (i) The cost of MCCBs , CT, instrument fuze holder etc shall be included in quoted rates and nothing extra shall be admissible. (ii) Quoted rate is also inclusive of PCC foundation, earth work, all electrical connections etc. for LT Feeder pillar panel. (iii) Panel drawing should be approved by Garrison Engineer .

-

-

-

... More
Schedule 'A' Part-XVI (Manning and Operation of STP)

-

-

-

... More
Outsourcing of services for 1st year after completion of Phase-I during defect liability period for manning and operation of main sewage treatment plant 216 T/Camp at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , after all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department. 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 1st year after completion of Phase-I during defect liability for manning and operation of main sewage treatment plant R center at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department . 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 1st year after completion of Phase-I during defect liability for manning and operation of main sewage treatment plant CE zone at BB Cantt by deploying 01 No trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 2nd year after completion of Phase-I during defect liability for manning and operation of main sewage treatment plant 216 T/Camp at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department. 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 2nd year after completion of Phase-I during defect liability for manning and operation of main sewage treatment plant R center at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department . 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 2nd year after completion of Phase-I during defect liability for manning and operation of main sewage treatment plant CE zone at BB Cantt by deploying 01 No trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 3rd year after completion of Phase-I for manning and operation of main sewage treatment plant 216 T/Camp at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department. 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 3rd year after completion of Phase-I for manning and operation of main sewage treatment plant R center at BB Cantt by deploying 02 Nos trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department . 5. Outsourcing staff will change after every 11 months.

365

-

-

... More
Outsourcing of services for 3rd year after completion of Phase-I for manning and operation of main sewage treatment plant CE zone at BB Cantt by deploying 01 No trained FGM per shift (each shift of 08 Hours) in three shifts round the clock including Sundays and holidays complete , all as specified and as directed by Engineer-in-charge . Notes: 1. FGM will opearate pumps and ensure proper functioning of all the pumps and motors in the installations. 2. Maintain a record of hours run of each pump set in a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department 5. Outsourcing staff will change after every 11 months.

365

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.