Military Engineer Services Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical Goods and Equipments
Eprocure
Opening Date4 Feb 2025
Closing Soon26 Feb 2025
Tender Amount₹ 1,15,59,000 
Notes
Download

Costs

Summary

Rep Maint Of Security Lights, Junctionbox,cables, Lt Oh Lines, Lt Apfc Panels, Mccbs Earthing Ug Cables Street Lights Mccbs And Dg Sets Amf Panels

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item 03 above but of size 4 core 10 Sqmm.

120

-

-

... More
All as per item 03 above but of size 2 core 16 Sqmm.

244

-

-

... More
All as per item 03 above but of size 4 core 16 Sqmm.

736

-

-

... More
All as per item 03 above but of size 4 core 25 Sqmm.

470

-

-

... More
All as per item 03 above but of size 3.5 core 25 Sqmm.

134

-

-

... More
All as per item 03 above but of size 3.5 core 35 Sqmm.

1059

-

-

... More
All as per item 03 above but of size 3.5 core 50 Sqmm

730

-

-

... More
All as per item 03 above but of size 3.5 Core 70 Sqmm

366

-

-

... More
All as per item 03 above but of size 3.5 Core 95 Sqmm

300

-

-

... More
All as per item 03 above but of size 3.5 Core 120 Sqmm

90

-

-

... More
All as per item 03 above but of size 3.5 Core 150 Sqmm

100

-

-

... More
All as per item 03 above but of size 3.5 Core 185 Sqmm

140

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in any type of soil for taking up or laying of cable or erection of poles or laying of pipes all as specified and directed.

915.05

-

-

... More
Excavation in trenches exceeding 1.5 M wide and exceeding 1.5 M in depth but and getting out in any type of soil for taking up or laying of cable all as specified and directed.

8.75

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.

545.74

-

-

... More
Removal of surplus soil to a distance not execeeding 50M and depositing where directed at a level not exc 1.5M above the starting point complete all as specified and directed.

365.98

-

-

... More
Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. NOTE : Punned thickness only shall be measured and paid

279.5

-

-

... More
M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.

25.5

-

-

... More
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.

3.3

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in fixing of pole, stay complete all as specified and directed.

44.86

-

-

... More
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping around pole etc complete all as specified and directed.

7.68

-

-

... More
Dismantling old and unserviceable pre stressed concrete /Steel poles any type including breaking cement concrete complete and supply, fixing and erection of steel tubular swaged pole with cast iron base plate, finial tapper plug, bolts, nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and directed.

32

-

-

... More
S&F in repairs Cable Junction Box/Distribution Board IP 65 with metric knockouts for cable entry of size 10 to 50 sq mm x 4 core including fastening clamp with LT pole, of suitable size, with locking arrangements including with terminals TPN strip, complete all as specified and directed.

35

-

-

... More
S&F in repairs tubing light grade galvanised for cable protection along the poles/ in trenches/under road or floor of 50 mm bore including all fittings, clamps complete all as specified and directed.

46

-

-

... More
M&L for Sub Main wiring using FR Insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing. drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fittings / switch complete all as specified and directed. NOTE: Two runs of cable for phase / neutral and one run of cable for earth including conduit will be measured and paid as one unit length.

404

-

-

... More
M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.20 Metre long bent to shape as specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket with clamps, complete all as specified and as directed.

50

-

-

... More
M&L in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point including testing on completion complete all as specified and as directed.

16

-

-

... More
M&L in repairs Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 150 Watt, as per existing make and type complete all as specified and directed.

20

-

-

... More
All as item no 31 above but for LED Light Fitting of capacity 100/120 Watt.

24

-

-

... More
All as item no 31 above but for LED Light Fitting of capacity 60/72/75 Watt.

38

-

-

... More
All as item no 31 above but for LED Light Fitting of capacity 45 Watt.

22

-

-

... More
M&L in repairs PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm including taking down existing unserviceable wire complete all as specified and directed.

350

-

-

... More
M&L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 6 sqmm including taking down existing unserviceable wire complete all as specified and directed.

430

-

-

... More
M&L in repairs PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 10 sqmm including taking down existing unserviceable wire complete all as specified and directed.

374

-

-

... More
M&L in repairs PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 16 sqmm including taking down existing unserviceable wire complete all as specified and directed.

270

-

-

... More
Supply and fixing LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existing unserviceable flood light fitting of any description complete all as specified and directed. Make: Bajaj Cat No. PRAZE F 180L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips/ Havells.

12

-

-

... More
All as per Ser Item No. 39 here-in-before but of 200 Watts Make: Bajaj Cat No. PRAZE F 240L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips/ Havells.

8

-

-

... More
All as per Ser Item No. 39 here-in-before but of 250/240 Watts Make: Bajaj Cat No. PRAZE F 300L WH NB-A5 TG SD or latest upgraded equivalent model in Wipro/Philips/Havells.

10

-

-

... More
Supply and fixing LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket duly removing existing unserviceable street light fitting complete all as specified and directed. Make: Bajaj Cat No. ENXT P 54L PO PC SD or latest upgraded equivalent model in Wipro/Philips/Havells.

68

-

-

... More
All as per item No. 42 here-in-before but of 60 watt Make: Bajaj Cat No. ENXT P 72L PO PC SD or latest upgraded equivalent model in Wipro/Philips/Havells.

63

-

-

... More
All as per item No. 42 here-in-before but of 70 watt Make: Bajaj Cat No. ENXT P 84L PO PC SD or latest upgraded equivalent model in Wipro/Philips/Havells.

46

-

-

... More
All as per item No. 42 here-in-before but of 90 watt Make: Bajaj Cat No. ZELA P 108L WH PO TG SD or latest upgraded equivalent model in Wipro/Philips/Havells.

50

-

-

... More
All as per item No. 42 here-in-before but of 120 watt Make: Bajaj Cat No. ENXT P 144L WH PO TG SD or latest upgraded equivalent model in Wipro/Philips/Havells.

32

-

-

... More
Supply and fixing LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket duly removing existing unserviceable light fitting complete all as specified and directed. Make: Bajaj Cat No. BGCTNP 40W LED WH or latest upgraded equivalent model in Wipro/Philips/Havells.

16

-

-

... More
Supply and fixing post top light/garden light fitting pin type holder, pvc round or ovel shape of size 6' dia complete with LED bulb pin type 15 watt fixing arrangement on existing pole/bracket duly removing existing unserviceable light fitting complete all as specified and directed.

11

-

-

... More
Supply and fixing Integral LED aviation light luminaire comprising of yellow painted LM6 aluminium alloy housing polycarbonate enclosure including takingdown existing unserviceable aviation light fitting complete all as specified and directed.

9

-

-

... More
Taking down of high mast light, Hot dip galvanised Mast 15/16meter high and Luminaires carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old unserviceable Winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising or lowering and re-installation, testing at site and comissioning after satifactorily repair complete all as specified and directed.

12

-

-

... More
Taking down of old unserviceable street light timer switch board of any type and Supply, installation, testing and commissioning street light distribution boards 12 KW, Digital 24 Hour capacity, 3 pole, 415 volt, made out of CRCA Sheet Steel with front openable door fitted with necessary hinges, door locking by Panel lock and provision for Pad Locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including provision of following switchgears/ components :- (a) Incoming MCB 63 Amp TPN - 01 No. (b) 3 pole contactor 65 Amp - 01 No. (c) Timer switch Digital type, 24 Hour - 01 No. (d) Auto/Manual selector Switch - 01 No. Make: Havells Cat Part NoHXTS09120 or equivalent in L&T/HPL/Indo asian.

4

-

-

... More
Taking down of old unserviceable street light timer switch board of any type and Supply, installation, testing and commissioning street light distribution boards max load 6 KW, Digital 24 Hour capacity, 230 volt, made out of CRCA Sheet Steel with front openable door fitted with necessary hinges, door locking by Panel lock and provision for Pad Locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including provision of following switchgears/ components :- (a) Incoming MCB 40 Amp SPN - 01 No. (b) 3 pole contactor 32 Amp - 01 No. (c) Timer switch Digital type, 24 Hour - 01 No. (d) Auto/Manual selector Switch - 01 No. Make: Havells Cat Part No IHXSS01060 or equivalent in L&T/HPL/Indo asian.

2

-

-

... More
Taking out old unserviceable PCC/steel tubular poles 9 mtr long and supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc including painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed.

5

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 400Amps 35 KA capacity 415V 50Hz with adjustable thermal and magnetic relay, Ics=100% Icu, 75% Icu including taking out the old unserviceable complete all as specified and directed.

7

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 250Amps 35 KA capacity 415V 50Hz with adjustable thermal and magnetic relay including taking out the old unserviceable complete all as specified and directed.

8

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 200Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic relay including taking out the old unserviceable complete all as specified and directed.

6

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 160Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay including taking out the old unserviceable complete all as specified and directed.

4

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 125Amps 35 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay including taking out the old unserviceable complete all as specified and directed.

8

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 100Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay including taking out the old unserviceable complete all as specified and directed.

7

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 100Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay including taking out the old unserviceable complete all as specified and directed.

10

-

-

... More
Supply and fixing of moulded case circuit breaker Four pole 63Amps 25 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay including taking out the old unserviceable complete all as specified and directed.

5

-

-

... More
M&L for GI tubing light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed.

36

-

-

... More
M&L for GI tubing light grade galvanised with all fittings laid in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed.

18

-

-

... More
M&L for earth continuity conductor using GI strip 32 x 6 mm as earthing lead complete all as directed including taking down the old unserviceable complete all as specified and directed.

74

-

-

... More
Supply and installation of on load change over switch in sheet metal enclosure of capacity 63 Amps, 4 pole complete all as specified and directed.

2

-

-

... More
S&F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 50W mounted on MCPCB suitable for 50 mm dia pipe in gress protection IP-66 complete all as specified and as directed.

54

-

-

... More
S&F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.

42

-

-

... More
S&F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.

36

-

-

... More
S&F in replacement of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 70W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and as directed.

28

-

-

... More
Taking down after disconnection of old unserviceable of street/security/road/post top light fitting and supply and fixing of LED based energy saving & environment friendly long life versatile luminaire made in pressure die cast housing and heat sink with aluminium extruded with IP-65 of 30 watt complete with front toughened glass cover including connection with 2.5 sqmm 3 core PVC insulated copper wire complete all as specified. Make : Cat part No .BCLST 30W LED of bajaj or equivalent in Havells/CG/Philips.

18

-

-

... More
Taking down after disconnection of old unserviceable of high mast light fittings and supply and fixing in replacement of LED based saving & enviornment friendly long life versatile flood light Lumos IP-65 of 200 W complete with front glass cover complete all as specified.

12

-

-

... More
M&L for earth continuity conductor /main earthing lead fixed to wall/batten or recess/chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complet all as specified and directed.

36

-

-

... More
M&L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Aluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate strips of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed.

129

-

-

... More
S&F in repairs MCCB 4 Pole, current rating 315/400 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, including necessary spreaders / cable lugs / nut, bolt and washers (if required) all as direcetd.

6

-

-

... More
All as per item No 74 here in before but 4 pole 250 A, having breaking capacity 36 kA

4

-

-

... More
All as per item No 74 here in before but 4 pole 200 A, having breaking capacity 36 kA

6

-

-

... More
All as per item No 74 here in before but 4 pole 160 A, having breaking capacity 36 kA

4

-

-

... More
All as per item No 74 here in before but 4 pole 100 /125 A, having breaking capacity 36 kA

3

-

-

... More
All as per item No 74 here in before but 4 pole 63 A, having breaking capacity 36 kA,

8

-

-

... More
S&F in repairs MCCB 3 Pole, current rating 315/400 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, including necessary spreaders / cable lugs / nut, bolt and washers if required all as direcetd.

4

-

-

... More
All as per item No 80 here in before but 3 pole 250 A, having breaking capacity 36 kA.

2

-

-

... More
All as per item No 80 here in before but 3 pole 200 A, having breaking capacity 36 kA.

4

-

-

... More
All as per item No 80 here in before but 3 pole 160 A, having breaking capacity 36 kA.

4

-

-

... More
All as per item No 80 here in before but 3 pole 100 /125 A, having breaking capacity 36 kA.

6

-

-

... More
All as per item No 80 here in before but 3 pole 63 A, having breaking capacity 36 kA.

4

-

-

... More
S&F in repairs APFC Relays with auto set function having 6 + 1 steps 7 stage suitable for 415 Volts incl necessary connections all as directed.

2

-

-

... More
S&F in repairs APFC Relays with auto set function having 4 + 1 steps 5 stage suitable for 415 Volts incl necessary connections all as directed.

2

-

-

... More
S&F in repairs APFC Relays with auto set function having 3 steps 3 stage suitable for 415 Volts incl necessary connections all as directed.

2

-

-

... More
S&F in repiars MPP type Box capacitor (Resin filled) three phase heavy duty type of capacity 20 to 50 KVAR rating suitable for 440 Voltage incl necessary connections all as specified.

20

-

-

... More
S&F copper bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board for any addition / alteration all as directed.

36

-

-

... More
S&F in repairs Aluminium bus bar of any size with necessary provision of hole with fixing of new nut, bolt and washers of existing size in the panel board all as directed.

14

-

-

... More
S&F in repairs of copper control cable multistranded with suitable size copper lugs crimped on both side of any type of size 25 Sqmm for internal connection including PVC tie all as directed.

30

-

-

... More
All as per item No 92 here in before but of size 16 Sqmm

50

-

-

... More
All as per item No 92 here in before but of size 10 Sqmm

65

-

-

... More
S&F in repairs Copper wound with CTR 400/5 A rating all as directed.

1

-

-

... More
S&F in repairs Copper wound with CTR 200/5A rating all as directed.

1

-

-

... More
S&F in repairs Indicator Lamps (LED type) showing R,Y, B phase all as directed.

2

-

-

... More
S&F in repairs Digital Ampere Meter 0 - 500 Amp, size 96x96 mm square type with selector switch complete all as specified and directed.

2

-

-

... More
S&F in repairs Digital Volt meter 0 - 400V, size 96 x 96 mm square type with selector switch complete all as specified and directed.

2

-

-

... More
S&F in repairs MCB TPN 63Amps, 415 V as per all as specified.

10

-

-

... More
S&F in repairs MCB TPN 32 amps 415 volts C series all as specified.

20

-

-

... More
S&F in repairs MCB DP 32 Amps 240 volts C series all as specified.

28

-

-

... More
S&F in repairs MCB SP 'C' series 10 Amps, 230V all as specified.

42

-

-

... More
M&L for Earthing complete with galvanised steel earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI strip 32x 6 mm thick dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed including dismantling existing earthing.

27

-

-

... More
Supply and fixing in repairs clamp made up of GI strip 25 x 3 mm thick to fix in the RCC/PCC pole for tying of street light connection cable of required length / size from bottom to top of the LT pole including necessary GI nut, bolt and washers complete all as directed.

10

-

-

... More
Service Charges for Carrying out 'C' Check maintenance for DG sets from authorised rep or service engineer from the OEM of DG set of Kirloskar / Cummins / Mahindra make of 100 to 200KVA capacity installed at various loactions, including injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, cleaning the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower / inside tank with solution (caustic soda with water) to the entire satisfaction, trial & testing etc. NOTE : New spares required for 'C' check will be measured and paid seperately as supply only.

12

-

-

... More
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete

12

-

-

... More
Supply only Element for Lubrication oil filter.

12

-

-

... More
Supply only Seal, O Ring

12

-

-

... More
Supply only Element Air Cleaner

12

-

-

... More
Supply only Tappet cover Gasket.

12

-

-

... More
All as per item No 106 above but DG set of 62.5 KVA to 82.5 KVA capacity

16

-

-

... More
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete

16

-

-

... More
Supply only Seal, O Ring

16

-

-

... More
Supply only Air Cleaner element

16

-

-

... More
Supply only Tappet cover Gasket.

16

-

-

... More
All as per item No 106 above but DG set of 30/35 KVA capacity

6

-

-

... More
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete

6

-

-

... More
Supply only Seal, O Ring

6

-

-

... More
Supply only Air Cleaner element

6

-

-

... More
Supply only Tappet cover Gasket.

6

-

-

... More
All as per item No 106 above but DG set of 20/25 KVA capacity

20

-

-

... More
Supply only Kit, fuel filter (Primary, secondary & super bye pass) and ring complete

20

-

-

... More
Supply only Seal, O Ring

20

-

-

... More
Supply only Air Cleaner element

20

-

-

... More
Supply only Tappet cover Gasket.

20

-

-

... More
Note :- (a) The 'C' Check Maint spares, engine oil, Coolant, caustic soda solution (restore plus) will be measured and paid separately under relevent item of this schedule. (b) Any other check as per manufacturer's instructions/ Engr In charge direction shall be carried out by the contractor and the same shall be demed to be included in the quoted rate.and directed.

-

-

-

... More
De-scaling of radiator assembly by carefully removing from the engine, transporting to the workshop (if required) and removing the sediments, scales and rust etc by means of acid cleaning, high pressure water washing and air cleaning, arresting the leakages by gas welding / soldering with suitable material at workshop or at site, re-assembling the same with new gaskets including replacement of radiator cap (wherever required) and fixing to the engine for DG Set of capacity from 100 KVA to 125 KVA complete all as specified and directed.

12

-

-

... More
All as per item No.127 here-in-before but for DG Set of capacity from 62.5 KVA to 82.5 KVA.

8

-

-

... More
All as per item No.127 here-in-before but for DG Set of capacity upto 35 /25KVA.

20

-

-

... More
Taking down the defective radiator assy from the position transport to work shop removing the damaged cooling fin layer, supply and fixing single layer radiator fin assy of complete set made up of copper fins and tube suitable for 82.5 to 125 KVA DG set of any make including bracing work in any layer for the same all as directed. NOTE : Each layer of cooling fin shall be measured and paid separetely.

2

-

-

... More
Attending of complaint duly finding of fault or defects in engine/ alternator/ AMF panel and rectification of defects including checking microprocessor based AMF control panel and connected programmed safety features, safety switches/ cut-outs / thermostats etc, removing and re-terminating the burnt wires, checking of all contactors/contacts for proper auto functioning and rectifying the faults/ faulty components by replacing with new spares and setting the relays setting of programming of operating parameters and safety limits (if required) etc complete all as specified and directed. NOTE :- Spair parts required to make serviceable will be measured and paid separately under respictive items of Sch A.

66

-

-

... More
Service Charges for Carrying out the 'B' Check maint from authorised rep or service engineer from the manufacturer of DG set of Engine Greaves/Kirloskar/Cummins of 100 to 125 KVA checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacment of filters, checking inlet & Exhaust manifold capscrews, checking of fan hub & water pump, toping up level the existing engine oil, coolant top up and in replacement, supplying & fixing of following spares :- (a) Kit, fuel filter and ring 01 set (b) Element for Lubrication oil filter 01 set (c) Kit, Element of super bypass filter 01 set (d) Seal, O Ring 01 set NOTE :- 'B' check shall be carried out on run of 500 hrs or 03 months which ever is earlier.

12

-

-

... More
All as per item No 132 above here above but DG Set Capacity 62.5 to 82.5 KVA

6

-

-

... More
All as per item No 132 above here above but DG Set Capacity 30 KVA /25KVA

6

-

-

... More
All as per item No 132 above here above but DG Set Capacity 20 KVA

16

-

-

... More
Supply & filling Coolant concentrate Superkool xtra as required in the DG oil sump all as directed.

260

-

-

... More
Supply & filling Engine Oil Premium Blue 15 W 40 grade API CI 4 PLUS / Kirloskar engine oil as required in the DG oil sump all as directed.

320

-

-

... More
Supply & checking cleaner Restore Plus solution Part No. AX1001098 Make : Cummins for engines cooling system all as directed.

1

-

-

... More
Dismantling the defective alternator / field winding of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / direct workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back to site re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete all as specified. NOTE : - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.

160

-

-

... More
S&F in repair door hinges for canopy of any capacity of DG set door including nut, bolt, drilling of hole, welding complete all as specified and directed.

5

-

-

... More
Dismantling the old and unserviceable DG Set rubber hose pipe complete set suitable for 20 to 62.5 KVA DG set of any make and type and replacing the same with existing size and equal length for any capacity DG Set including both side hose clamp, with nut, bolt and washers as required , etc as directed by the Engineer in Charge .

5

-

-

... More
All as per item No 140 here in before but for 80 KVA to 125 KVA DG set all as directed.

2

-

-

... More
Supply and connecting battery lead (not less than 1.00 m long each) made out of PVC Insulated Plain/Striped Automobile Cables with high conductivity bright annealed copper conductor bunched together, insulated with dielectric grade PVC compound (impervious to oils, greases, acids, petrol and water) conforming to IS 2465 of size 25 sqmm soldered one end with copper/brass connector with nuts and bolts for battery pole and the other with copper lug for self starter terminal including taking down of existing unserviceable battery lead with connector and lug of any description complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing in repair rectifiers diodes for 20/125 KVA DG sets complete all as specified and directed.

2

-

-

... More
S & F in repair battery charging unit panel mounted automatic operated electronically 24 Volts DC out put and 230 volts incoming AC , as per the existing make and size to accomodate in the space provided in the AMF panel board.

1

-

-

... More
Supply and fixing in repair maintenance free battery 12V, 180 AH for DG set including initial filling & Charging complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
All as per item No. 146 here-in-before but of rating 12V, 150 AH.

2

-

-

... More
All as per item No. 146 here-in-before but of rating 12V, 80/90/100 AH.

2

-

-

... More
Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewinding with ‘F’ class copper wire of 22 /existing gauge including dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/alternator properly including testing on completion complete all as specified.

4

-

-

... More
Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site complete all as specified.

4

-

-

... More
Dismantling the defective self starter assembly 12V/24V carefully from the DG set and carryout repair and servicing by cleaning all accessories with suitable cleaning agent and supply and replace commentator, carbon brush set, carbon brush holder, king pin holder, armature choke nut, body screens, clutch plate assy and solenoid etc re-assembling and re-fixing the same and testing on completion for DG set of capacity from 100 KVA to 125 KVA complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
All as per item No. 151 here-in-before but for DG set of capacity from 62.5 KVA to 82.5 KVA.

4

-

-

... More
All as per item No. 151 here-in-before but for DG set of capacity from 20 KVA to 35 KVA

6

-

-

... More
M&L for providing new AVR unit suitable for 82.5 KVA to 125 KVA DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford

2

-

-

... More
All as per Item No 154 above, but for 20 to 62.5 KVA DG set

2

-

-

... More
Dismantling the old and unserviceable DG Set Diesel/oil pressure pipe of existing size and replacing the same with existing size and equal length of 20 KVA to 62.5 KVA DG Set including both side hose clamp , etc as directed by the Engineer in Charge .

6

-

-

... More
Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applying insulating varnish of 'F' class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete all as specified.

30

-

-

... More
Supply and fixing of lamp indicator assy LED lamp type 230 volts AC complete all as specified.

6

-

-

... More
Supply and wrap asbestos rope of 10 mm dia of superior quality over silencer of DG sets including taking down of existing unserviceable rope complete all as specified and directed by Engineer-in-Charge. NOTE: Straight length of silencer is measured for the purpose of payment

20

-

-

... More
S&F in replacement fan belt suitable for 82.5 KVA to 125 KVA DG Set as per existing model and size including dismantling the old one complete all as specified and directed.

3

-

-

... More
All as per item No 160 above but for 20 KVA to 62.5 KVA DG Set.

4

-

-

... More
Scraping the old paint from the DG set of 20 KVA to 125 KVA capacity, applying one coat of synthetic enamel paint of approved make by using spray gun, writing of SM/MES No at easily visible manner complete as directed.

2

-

-

... More
S&F in repairs self starter 12V/24V with solenoid switch assy complete set as per existing make of DG Set 20 to 62.5 KVA all as directed.

1

-

-

... More
S&F in repairs self starter with solenoid switch assy complete set as per existing make of DG Set for 82.5 to 125 KVA all as directed.

1

-

-

... More
S&F in repairs new Dynamo / Alternator assy 12 / 24 Volts of existing type and capacity suitable for DG set of 20 to 125 KVA capacity including necessary electrical connections all as directed.

3

-

-

... More
S&F in repairs solenoid switch complete set as per existing size and make of DG Set 20 to 125 KVA DG Set all as directed.

2

-

-

... More
S&F in repairs magnetic speed censor assy suitable as per existing make of DG sets.

2

-

-

... More
S&F in repairs Electronic Speed control unit suitable for 20 to 125 KVA Capacity of any make DG sets including neccessary connections and testing complete all as directed.

2

-

-

... More
Dismantling and taking out the defected speed Governor unit with fuel injector pump assy from the DG set of capacity 100 KVA to 125 KVA, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. NOTE : The cost of spares like new injector / nozzle / gasket / seal / nut, bolt and washers are deemed to be included in the quoted rates.

3

-

-

... More
All as per item No. 169 here-in-before but for DG set of capacity 62.5 KVA to 82.5 KVA.

3

-

-

... More
All as per item No. 169 here-in-before but for DG set of capacity 20 KVA to 35 KVA.

2

-

-

... More
Taking down unserviceable engine wiring and M&L for rewiring of engine safety control system from control panel to engine control gadgets like HWT, LLOP, shut down valve, dynamo & self-starter etc for DG set of capacity from 100 KVA to 125 KVA complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
All as per item No. 172 here-in-before but for DG set of capacity from 62.5 KVA to 82.5 KVA.

2

-

-

... More
All as per item No. 172 here-in-before but for DG set of capacity upto 35 KVA

2

-

-

... More
S&F in repairs self starter push button / or with Key arrangement for DG starting suitable for Kirloskar / Cummins DG sets all as directed.

8

-

-

... More
S&F in repairs micro processor based DG control unit suitable for 20 to 125 KVA Capacity as per existing make of DG sets including neccessary connections and testing complete all as directed.

2

-

-

... More
S&F of distilled water in the DG set battery all as directed.

196

-

-

... More
S&F in repairs Feed pump unit, hand operated for 20 to 125 KVA capacity DG sets complete all as specified.

2

-

-

... More
M&L for opening the cylinder head of the engine and oil sump carefully for replacement of head gasket including sump gasket complete refixing the head and sump to arrest oil leakage with engine complete with proper alignment and testing the engine for 1 hrs on load to achiveve designed parameters all as directed by Engineer-in-Charge of capacity 20 KVA to 125 KVA.

2

-

-

... More
Supply, erection, testing and commissioning in repairs outdoor type factory made powder coated AMF Panel Board cubical type, over all size not less than 1000x750x400 mm suitable for DG set 125/100 KVA capacity, with suitable size 4 Nos copper bus bar 400 amps, having locking arrangments floor mounted free standing weather proof panel with IP-54 protection fabricated out of suitable size angle iron and flat and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished and then painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-500 Amps, Digital Voltmeter 0-500 Amps, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:- Location:-14 WEU UNIT AT OAF (a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains. (b) HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start/ stop logic - Mains/ Generator Voltage & Frequency sensing (d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No's (for alternator & mains. (g) Current Transformers of suitable rating

1

-

-

... More
Supply, erection, testing and commissioning ie repairs outdoor type factory made powder coated AMF Panel Board cubical type, over all size not less than 1000x750x400 mm suitable for DG set 82.5 KVA capacity, with suitable size 4 Nos copper bus bar 400 amps, having locking arrangments floor mounted free standing weather proof panel with IP-54 protection fabricated out of suitable sized angle iron and flats and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished and then painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-300 Amps, Digital Voltmeter 0-500 Volts, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:- at 323ad regmt Unit. (a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains (b) HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start/ stop logic - Mains/ Generator Voltage & Frequency sensing (d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No's (for alternator & mains) (g) Current Transformers of suitable rating

1

-

-

... More
Supply, erection, testing and commissioning in repairs outdoor type factory made powder coated AMF Panel Board cubical type, over all size not less than 1000x750x400 mm suitable for DG set 25 KVA /35KVA capacity, with suitable size 4 Nos copper bus bar 400 amps, having locking arrangments floor mounted free standing weather proof panel with IP-54 protection fabricated out of suitable size angle iron and flat and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished and then painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-200 Amps, Digital Voltmeter 0-500 Vols, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:-Location HQ 134 CWE Office DG set. (a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains. (b) HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start/ stop logic - Mains/ Generator Voltage & Frequency sensing (d) Aluminium bus bars of suitable capacity with incoming/ outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 4 pole with overload and short circuit protections - 02 No's (for alternator & mains) (g) Current Transformers of suitable rating

1

-

-

... More
Supply and laying Copper cable 2.5 sqmm 8 core suitable for connection of AMF Panel with protection pipe complete all as specified and directed.

144

-

-

... More
M&L for isolating, disconnecting and transporting the Servo voltage stabilizer of capacity 25 KVA to 100 KVA workshop for repair, strip opening of stabilizer for inspection and ascertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed by Engr-in-Charge. NOTE:- Parts required for replacement will measured and paid seperately under respective items.

4

-

-

... More
Supply and fixing in repair of LT current transformer ratio as per existing rating in LT panels complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair of Auto/Manual selector switch of voltmeter/ammeter in LT panel boards complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity upto 25 KVA to 75 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per srl item No. 187 here-in-before, but of capacity 100 to 250 KVA complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Taking down old burnt out winding and replacement of same for stabilizer oil immersed type of capacity 25 KVA to 250 KVA by using suitable gauge super enamelled copper conductor as per existing winding complete all as specified and directed by Engr-in-Charge.

216

-

-

... More
Supply of insulation transformer oil topping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV all as specified and directed by Engr-in-Charge.

465

-

-

... More
Dehydration of transformer oil for LT/HT AVR/Servo voltage stabilizer upto BDV not less than 50 KV all as specified and directed by Engr-in-Charge.

6500

-

-

... More
Supply and fixing in repair cast iron dimmer gear set for automatic voltage correction capacity 25 KVA to 250 KVA with as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing in repair micro limit switch with cam lever complete for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair of servo motor synchronous type of torque capacity 10 Kg for automatic voltage correction suitable for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair servo dimmer booster coil for automatic voltage correction suitable for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair Carbon brush with holder assembly for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing in repair bush rod brass for servo stabilizer of capacity 25 KVA to 250 KVA as per site requirement for type and make complete all as specified and directed.

5

-

-

... More
Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 25 KVA to 250 kVA complete all as specified and directed.

2

-

-

... More
Supply and fix in repair of over load relay for 25 to 250 KVA voltage stabilizer complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair of graphite carbon brush suitable for Servo voltage stabilizer of any capacity, complete all as specified and directed.

44

-

-

... More
Supply and fixing in repair of Capacitor of capacity 1.42 to 4.0 MF + 5%, 440V, AC 50Hz, complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing in repair of Pinion with gear (Medium) suitable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fixing in repair of Pulsing Transformer heavy duty suitable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair of Control Transformer heavy duty suitable for servo stablizer of any capacity, complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair Off Load change over switch 100 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repair Off Load change over switch 200 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Cat No. BJFL 150W LED I or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves

3

-

-

... More
All as per Ser Item No. 207 here-in-before but of 200 Watts Make: Bajaj Cat No. BJFL 200W LED I or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves

2

-

-

... More
All as per Ser Item No. 207 here-in-before but of 240 Watts Make: Bajaj Cat No. BJFL 240W LED WH MB or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves

2

-

-

... More
Notes :- An amount of Rs. 1,06,800.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.