Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date15 Jun 2024
Closing Date15 Jul 2024
Tender Amount₹ 34,20,000.0000000005 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Non-skid, coloured, designer ceramic tiles 7 to 8 mm thick (square/ rectangular) (Designer Pattern) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 etc, complete all as specified and as directed by Engineer-In-Charge.

34

-

-

... More
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) Designer Pattern, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 etc, complete all as specified and as directed by Engineer-In-Charge.

12

-

-

... More
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 laid over and incl cement concrete type B-0 1:2:4 using 12.50mm graded stone aggregate 25mm thick as in flooring etc, complete all as specified and as directed by Engineer-In-Charge.

160

-

-

... More
Non-skid, joint free, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.

14

-

-

... More
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.

102

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by engineer in charge.

170

-

-

... More
M&L for coloured Glazed ceramic tiles joint free in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.

276

-

-

... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washining down with water to remove dust etc after that applying brushing neat cement slurry with 3.0 Kg of cement per Sqm to receive to kota stone/floor tile

6.5

-

-

... More
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.

6.5

-

-

... More
M&L Makrana white marble work (of any type) work (table rubbed and polished), 18-20mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in 20mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of markrana, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.

156

-

-

... More
Machine cut kota stone slab, (size shall in one length), 18-20mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.

10

-

-

... More
M&L for repairs to sunken floor/ slab with the following specifications:- (a) Demolition of PCC and taking out old brick bat fillihng and roughening surfaces of old concrete floor and wall by picking, sweeping clean and washing down with water to remove dust etc. (b) PCC 1:2:4,type B-0, using 12.5mm graded stone aggregate averaging 50mm thick as in sunken floor,with proper slope towards GI spout. Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required area not exc 150sqcm, incl provn of GI spout pipe of 50mm of Medium grade. The minimum length of Spout shall be 500mm and if any spout comes above chajja than the length of the spout shall be more than Chajja projection. Ends of Spout shall be tippered and any cutting through brick/ RCC structure shall be done by the Contractor and rates are deemed to be included of this aspects. (c) providing 15mm thick cement plaster in cement mortar 1:3 mixed with water proofing compound @ 3% by weight of cement over bottom and vertical surfaces finishing the surface even and smooth without using extra cement. (d) Damp proof course on horizontal / Vertical surfaces with preparation & applying one coat of self priming (33% dilution) and two coats of undiluted material @ 10.67 lts per 10 sqm of Make : smart care Damp proof of M/s asian paint or equivelent for water proofing compound. (e) Graded Brick bats filling under sunken floor. (f) PCC 1:3:6,type C-1,using 20mm graded stone aggregate 75mm thick, over brick bats filling as in subbase to receive tiles. Note:- (i) For payment purpose only floor area shall be measured and entire work shall be carried out to the dimensions as directed by Engr-in-Chrage to meet the purpose. all aspect shall be deemed to be included in unit rates and nothing extra shall be admissible from the Deptt.. (ii) After Coating of Water proofing compound ponding test shall be carried out by filling the sunken surface with water for 72 Hrs and get approved by Engr-in-Charge if any leakage/ seepage noticed the Contractor will re do the whole process without any extra payment. (iii) Cost of PCC , M-15, type B-1 (using 20mm graded crushed stone aggregates) for chamfering the edges and rounding the sides as directed by Engr-in-Charge shall also be deemed to be included in the quoted rates. (iv) Cost of all materials in the specification unless otherwise specified shall deem to be included in the quoted rate.

4

-

-

... More
Grubbing up bushes , tree trunks portion not exc 30CM girth including cutting of trees/bushes grown in over wall and roofs digging out roofs and making good disturbed area of walls and roofs with PCC type C-1 , 1:3:6 using 20mm graded crushed stone aggregates and matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.

3

-

-

... More
Repair to RCC projection chajjas , roof fascias etc by scraping , cutting, chiseling , de-rusting and cleaning of exposed reinforcement surfaces, losse RCC surface with cement concrete in M-20(1:1.5:3), type A-1, (using 12.50mm graded crushed stone aggregate), nominal mix and reinforcement with welded mesh had drawn steel wire fabric of weight exc 2.0Kg/Sqm but not exc 4.0Kg/Sqm cut to length and shape required and tie with and including mild steel wire (annealed) not less than 0.9mm in dia as required, with or without fascia and finished with cement mortar15-20mm thick in 1:3 in patches area not exc 5.0 Sqm and thickness of RCC members n exc 70mm incl necessary form work and applying two coats of finishes to match with the existing surfaces at any height , complete all as specified and as directed by Engineer-In-Charge. Note : 1.0 Cost of steel wire fabric of required weight and size as directed shall deem to have been included in the quoted rates. 2. Cost of necessary saftey arrangements like ladders, saftey harness, scaffolding shall also be deemed to have been included in the quoted rates.

32

-

-

... More
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed.

98

-

-

... More
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.

88

-

-

... More
Refixing old steel tubing galvanised, 15mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.

10

-

-

... More
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed.

38

-

-

... More
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.

33

-

-

... More
Refixing old steel tubing galvanised, 20mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.

5

-

-

... More
Angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed.

6

-

-

... More
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed.

4

-

-

... More
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 20mm bore pipe, fixed in repairs, complete all as specified and as directed.

2

-

-

... More
Wall mixer with bend pipe for overhead shower with built-in non return valve, for hot and cold water, chromium plated, for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1014402 of Cera/ Jaquar/ Hindware.

4

-

-

... More
Wall mixer as in sink mixer return valve, for hot and cold water, 2 in 1, cast copper alloy with capstan head, long screwed shank shanks and fly nuts, chromium plated, for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Centre hole basin mixture for hot and cold water, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1013451 of Cera/ Jaquar/ Hindware.

2

-

-

... More
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.

18

-

-

... More
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 liters and making good to dismantled/ damaged floor/ surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.

6

-

-

... More
Brass chromium plated shower rose 125mm size, fancy type, fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Sinks with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

6

-

-

... More
Brass grating, chromium plated, size 150mm, heavy duty, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Plate rack (kitchen stand) stainless steel, size 780x900x250mm, thickness of stainless steel sheet not less than 0.80mm, weight not less than 7.50Kg each, fixing by means of electrical drill machine, fasteners and screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
S&F in replacement of old UNSV tank Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.

6

-

-

... More
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 15mm dia with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes.

4

-

-

... More
Vitreous China urinal, half stall, flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern and flush pipe but including of waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. but excluding concrete bedding layer, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Tubular towel rail, 20mm dia, D-type, 60cm long between flanges, brass chromium plated, fancy type, including end brackets, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

6

-

-

... More
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified.

46

-

-

... More
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified.

23

-

-

... More
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.

46

-

-

... More
Factory made solid panel PVC door shutter with wood free EPS, 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame with three Nos of stainless butt hinges of 100mm size and rust proof screws, at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.

14

-

-

... More
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.

60.6

-

-

... More
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.

77.7

-

-

... More
Plain cement concrete Nominal Mix (1:2:4) M-15, type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, as in kerb stone, coping, complete all as specified and as directed by Engineer-In-Charge.

0.5

-

-

... More
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.

0.94

-

-

... More
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.

42.6

-

-

... More
Glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats including 0.56mm nominal dia of wire cloth with average width of aperature 1.18mm fitted with staples etc, complete all as specified and as directed.

24.4

-

-

... More
Framed work as in doors or gates of angle or other section and as in frame work of cooler stand, ornamental work, rails fastening and heavy bracket etc, conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed by Engineer-In-Charge.

160

-

-

... More
Supply and fixing in repair of cup board shutter 20mm thick (style) factory made PVC incl chowkat frame made out of MS tubes of 19 guage for top and bottom rails M S frame shall be covered with heated molded designer colour PVC channel having PVC sheet strip of 10 MM width stuck inside with solvent cement for styles and plane colour PVC sheets of top rail, lock rail and bottom rail on either side 10 mm (5 mm x 2) thick of 20 mm and 20 mm cross PVC sheets and as gap inserted for top and bottom rail. Paneling for plain colour PVC sheets to be fitted in the MS frame welded /sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement in the frame at site as per drawing held with AGE B/R-I and to the entire specifications. , complete all as specified and as directed by Engineer-In-Charge.

13

-

-

... More
Prelaminated particle board,18/19mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, as in cup boards, drawers, shutters, fixed with screws to timber frame work, complete all as specified and as directed by Engineer-In-Charge.

7

-

-

... More
Extra over block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails, complete all as specified and as directed by Engineer-In-Charge.

26

-

-

... More
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1517/15, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.

35.3

-

-

... More
Factory made steel Ventilator, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1517/15, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.

4.3

-

-

... More
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.

108

-

-

... More
Aluminium handles, cast type, anodised, size 150mm, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.

89

-

-

... More
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.

89

-

-

... More
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.

11

-

-

... More
Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.

34

-

-

... More
Hasp and staple, safety type, size 100mm, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.

154

-

-

... More
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.

94.75

-

-

... More
Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.

18

-

-

... More
Curtain rod, 20mm dia, mild steel, fancy type, any colour coated, pvc layered with fixing and including end knobs, fixing brackets, stops, round rings to hold the curtain, fixing in repairs with wall plugs and screws, complete all as specified and as directed by Engineer-In-Charge.

42

-

-

... More
Taking down carefully existing rolling shutter and cleaning of all the ball bearings with necessary replacement of damaged ball bearings and locking arrangements and re-fixing the same with necessary greasing and one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge. Note : Cost of Complete materials required for the above specification shall deem to have been included in the quoted rate and nothing shall be paid extra on this account.

2

-

-

... More
Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cant area, complete all as specified and as directed by Engineer-In-Charge.

249

-

-

... More
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and applying two coats of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quoted rate.

119

-

-

... More
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and lincluding Precast machine pressed factory made PCC tiles, size 300x300mm and 20mm thick, with grey cement and no pigment, pointed in cement mortar 1:3 and laid over 15mm thick bedding layer in cement mortar 1:4 mixed with creosote oil @5% by weight of cement, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quoted rate.

130

-

-

... More
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.

4.5

-

-

... More
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.

4.5

-

-

... More
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.

1946

-

-

... More
Rendering 15mm thick, on any surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.

964

-

-

... More
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.

260

-

-

... More
Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed included in quoted rates.

616

-

-

... More
Preparation of on any surface plastered or unplastered surfaces of walls and applying one coat of acrylic smooth exterior paint of required shade @ 1.67KG/10SQM including exterior primer @ 2.20Kg/10SQM, complete all as specified and as directed by Engineer-In-Charge.

460.5

-

-

... More
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.

780

-

-

... More
Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls including complete removal of existing treatment, making surface even and filling weather proof putty in small holes, cavities, cracks and applying two coat of distemper oil emulsion over one layer of wall care putty, complete all as specified and as directed by Engineer-In-Charge.

32.4

-

-

... More
Preparation of new plastered or unplastered surfaces of wall and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.

194

-

-

... More
Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls including complete removal of existing treatment, making surface even and filling weather proof putty in small holes, cavities, cracks and applying two coats of white washing, complete all as specified and as directed by Engineer-In-Charge.

110

-

-

... More
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.

206

-

-

... More
M &L for preparation of old surfaces of ceiling, plastered or unplastered including brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying two coats of white wash on ceiling complete all as specified and directed

110

-

-

... More
M &L for preparation of old surfaces of ceiling, plastered or unplastered including brooming down or steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceiling complete all as specified and directed

150

-

-

... More
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement paint over a coat of primer, complete all as specified and as directed.

136

-

-

... More
Dismantling/ taking out of cast iron drain pipes of 100mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.

25

-

-

... More
Dismantling/ taking out of cast iron drain pipes of 75mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.

26

-

-

... More
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.

10

-

-

... More
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, lfixed on walls, complete all as specified and directed by Engineer-In-Charge.

15

-

-

... More
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed by Engineer-In-Charge.

15

-

-

... More
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, fixed on walls, complete all as specified and directed by Engineer-In-Charge.

11

-

-

... More
Cast iron bends, 100mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Cast iron bends, 75mm bore pipe (any radius), with duck's foot or heel rest, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Cast iron branch pieces, 100mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Cast iron branch pieces, 75mm bore pipe, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Cast iron bends, 100mm bore pipe (any radius), diminishing pieces or tapers (larger bore measured), fitted with oval access doors, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Cast iron bends, 75mm bore pipe (any radius), diminishing pieces or tapers (larger bore measured), fitted with oval access doors, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Cast iron branch pieces, 100mm bore pipe, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Cast iron ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Cast iron floor trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.

8

-

-

... More
Cast iron floor trap, with grating of 75mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Salt-glazed stoneware gully traps, size 150x100mm, square or round mouthed, type 'P' including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
PVC waste pipe, 32mm bore with cup washers, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge. Note : Necessary reinforcement and form wrok shall be deemed to have been included in the quoted unit rates, and nothing extra shall be admissible.

0.6

-

-

... More
Ball valves 20mm bore dia high pzessure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed by Engineer-In-Charge.

6

-

-

... More
Sheet glass shelf assembly, consisting 5.50mm thick sheet glass, 120mm wide including anti rust screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
2nd class hard wood (Kail) as in plain fillets, square, rectangular or triangular in section, clean sawn, sectional area exc. 13 Sqcm but not exc. 25 Sqcm, fixed with nails, all as specified.

25

-

-

... More
Cupboard knobs of 40mm fixed with and including necessary fixtures, complete all as specified and as directed by Engineer-In-Charge.

24

-

-

... More
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flap 40mm , complete all as specified.

20

-

-

... More
Demolition and breaking up drain pipes (Salt glazed ware, CI,AC or Reinforced concrete) of 150mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.

45

-

-

... More
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.

44

-

-

... More
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1 including Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 150mm internal dia, set in cement mortar incl taking down old one of any specification,, complete all as specified and as directed by Engineer-In-Charge.

45

-

-

... More
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, fixing in repairs, complete all as specified and as directed.

42

-

-

... More
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed.

8

-

-

... More
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.

12

-

-

... More
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), manhole covers etc, including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.

0.6

-

-

... More
Demolition of cement concrete (reinforced) in any position and location and including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.

0.1

-

-

... More
M&L Reinforced Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, as in chajjas , water troughs and the like including weathering, slightly rounded or chamfered angles and throating incl necessary reinforcement and form work , all as specified. Note : Necessary reinforcement and form wrok shall be deemed to have been included in the quoted unit rates, and nothing extra shall be admissible.

0.3

-

-

... More
Chequered cement concrete glossy finish coloured tiles size 400mmx400mmx20/25mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 20mm thick screed bed or bedding layer in cement mortar 1:6 laid over and including 75mm thick sub base of Nominal Mix PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, complete all as specified and as directed by Engineer-In-Charge.

80

-

-

... More
Cleaning of blocked/ choked SGSW/ Cast Iron drain pipes/ sewer lines of any dia and any types, in horizontal or vertical position by rodding, from manholes to manholes and manholes end to septic tanks/ soakage wells, flushing with pressure jet of water/ sewage suction machine after taking out existing manholes covers and putting back manhole covers in original position after cleaning of lines including removing the sludge and other waste materials/ blockage in drain pipes, transport to outside of Unit/ Cantonment area and spreading bleaching powder on top of manholes covers of septic/ soakage pits or in the surrounding areas to make hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of transportation of waste materials shall be deemed included in quoted rates.

3

-

-

... More
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.

200

-

-

... More
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed by Engineer-In-Charge.

200

-

-

... More
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.

9

-

-

... More
Excavation in trenches n exc 1.5 metre wide & n. exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes/cable/pipe line etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.

14.8

-

-

... More
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.

7.88

-

-

... More
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.

6.92

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.

185

-

-

... More
Point wiring (in new concealed conduits to surfaces), modular type for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including steel modular boxes, of minimum thickness 1.20mm modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of steel modular boxes, modular cover plates, blank plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.

71

-

-

... More
Description all as per serial item No- 131.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.

16

-

-

... More
Description all as per serial item No- 131.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.

16

-

-

... More
Description all as per serial item No- 131.00 here-in-before but for one light point controlled by two way switches.

1

-

-

... More
Point wiring (in new concealed conduits to surfaces), modular type, for 3/6-pin, 15 Amps, socket outlet on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including steel modular boxes, of minimum thickness 1.20mm modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of steel modular boxes, modular cover plates, blank plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.

8

-

-

... More
Re-fixing of existing Geyser after taking down from the hanging location incl PVC connection, cleaning the same with cleaning material as directed incl testing after completion of the job, complete all as specified.

4

-

-

... More
Re-fixing of existing ceiling fan of existing sweep, after taking down from the hanging location and dismantling of blades from the fan, cleaning the same with cleaning material as directed including painting there of with one coat of synthetic enamel paint by spraying Gun including filling cavities with filler and re-assembling the blades with fan & connecting up with twin core twisted flexible copper conductor cable of suitable size from ceilng rose to fan incl testing after completion of the job, complete all as specified.

8

-

-

... More
Re-fixing of existing Exhaust fan of existing sweep, after taking down from the hanging location and dismantling of blades from the fan, cleaning the same with cleaning material as directed including painting there of with one coat of synthetic enamel paint by spraying Gun including filling cavities with filler and re-assembling the blades with fan & connecting up with twin core twisted flexible copper conductor cable of suitable size from ceilng rose to fan incl testing after completion of the job, complete all as specified. Note : Item form Srl item 136.00 to 138.00 shall be deposisted to AGE E/M store before start of any repair work and shall be collettd from the store and refixed as designated place as per respective specification after the repair work is accomplished.

4

-

-

... More
Modular switch piano, single pole, one way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.

99

-

-

... More
Modular switch piano, single pole, two way, 5/10 Amps, 1/2 module complete all as specified and as directed by Engineer-In-Charge.

2

-

-

... More
Modular bell push switch, single pole, one way, 5-Amps, 1/2 module, 240 volts, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Modular switch 1 way 16A, 1/2 module 240 Volts, complete all as specified and directed by Engineer-In-Charge.

8

-

-

... More
Shuttered Socket outlet modular type, 6A -5 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.

32

-

-

... More
Shuttered Socket outlet modular type, 6/16A -6 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.

8

-

-

... More
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.

12

-

-

... More
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.

45

-

-

... More
Description all as per serial item No- 146.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.

9

-

-

... More
Description all as per serial item No- 146.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.

10

-

-

... More
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.

9

-

-

... More
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.

45

-

-

... More
Switch socket combination 2-in-1, 3-pin, 5 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.

19

-

-

... More
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.

9

-

-

... More
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.

3

-

-

... More
Door bell, AC, 230 Volts, single pole, ding-dong type sound, completeall specified and as directed by Engineer-In-charge.

4

-

-

... More
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.

77

-

-

... More
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.

18

-

-

... More
S&F in replacement of LED retrofit lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, complete all as specified and as directed by Engineer-In-Charge.

18

-

-

... More
Modular LED indicator lamp fixing on modular switch board 240V, AC , 50Hz suitable for 1/2 module including making necessary connection with suitable size PVC insulated copper wire complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
S&F in replacement of 4 feet highly engineered plastic body suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM 5, CRI 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor 0.95 and THD 20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Havells cat part No LUMILINE PLUS PRO BATTEN, MODEL NO LUMILINEPLUSPROBS20WLED865SPCSSIND or Equivalent makes in Crompton/Philips/Benlo/HPL. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.

43

-

-

... More
Replacement of old unserviceable/ damaged LED mirror light, including LED lamp capacity 10 Watt, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat Part No LED Pride Plus Neo Batten 10 W 6500 K or equivalent in Benlo/HPL/Crompton/Philips.

4

-

-

... More
S&F in replacement of old unserviceable/ damaged Decorative, wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base., including LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge. Make: Model No STYLO, Havells ordering cat part No-LHFOECE1TZ1O014 or equivalent in Benlo/HPL/Bajaj

12

-

-

... More
S&F in replacement of old unserviceable/ damaged Environmental friendly , ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified. Make: Havells ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Benlo/HPL/Crompton/Philips..

6

-

-

... More
S&F in replacement of old of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be of made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 to with stand extreme environments with PF 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection , complete all as specified. Make : Havells model No ENDURA SUNDOWN TG,Cat Part No ENDURASUNDOWNSL45WLED765PASYBOTG or Equivalent in Benlo/HPL/Bajaj. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.

6

-

-

... More
S&F in replacement of House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified.

12

-

-

... More
S&F in replacement of old of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 35W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be of made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 to with stand extreme environments with PF 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Havells model No ENDURA SUNDOWN ,Cat Part No ENDURASUNDOWNSL35WLED765PASYBOPC or Equivalent in Benlo/HPL/Bajaj. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.

1

-

-

... More
Sheet metal enclosures in replacement of with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.

4

-

-

... More
S&F in replacement of Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.

7

-

-

... More
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.

48

-

-

... More
S&F in replacement of MCB, Single Pole and Neutral, 6-32 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.

7

-

-

... More
S&F in replacement of MCB, Triple Pole and Neutral, 63 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
M&L in replacement of Sub main wiring (concealed conduits to surfaces) in replacement of for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.

48

-

-

... More
M&L in replacement of Sub main wiring (concealed conduits to surfaces) in replacement of for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.

24

-

-

... More
Supply, laying commissioning, testing in replacement of XLPE LT cable 1100 volts grade of size 16 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etc after taking out existing under ground cable complete all as specified and directed.

100

-

-

... More
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.

3.24

-

-

... More
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.

0.33

-

-

... More
S&F in replacement of Tubes, Light grade' galvanised, 40mm bore, ISI marked with all fittings and fixed to walls and ceilings or laid in floors for lightening conductor, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.

6

-

-

... More
S&F in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-20)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.

4

-

-

... More
Amount of Schedule of credit of for Rs 88,096.00 shall be deducted from quoted amount.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.