Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date27 Feb 2025
Closing Date4 Apr 2025
Tender Amount₹ 2,30,00,000
AI Insights
Technical
Technical
Class Of Bidder
... View More
Class 'B' and above.
Bid Capacity
... View More
For MES enlisted contractors one class below the eligible class, the bid capacity required is 5 times their tendering limit, unless they meet the upgradation criteria. For unenlisted contractors, the bid capacity required is 2 times the tendering limit of the MES Class they are eligible for. However, specific numerical values or a direct formula for calculating bid capacity based on the tender value are not provided.
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completing similar works. For MES enlisted contractors, they should have satisfactorily completed works reflected in the Work Load Return (WLR) or any other report circulated by the Competent Engineer Authority. For contractors not enlisted with MES, they should meet the enlistment criteria of 'B' class and category c(vii) contractor, which includes satisfactorily completion of requisite value works with Central/State Government/Central/State PSUs/AWHO/AFNHB/CGEWHO/DGMAP. However, the specific value and percentage of similar works completed are not mentioned. Bidders who are one class below the eligible class must have previously completed similar works satisfactorily and meet the criteria of upgradation in respect of past experience of completed works. No specific amount or percentage is mentioned for similar works completed.
Costs
EMD
₹ 3,05,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699496_1Tender No
CA NO. CEPZ-47/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
(vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. (vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS
1.5 HP each pump) 4.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. Make Xylem/Grundfoss/KSB (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 200 LPM , 125 psi pressure. (ix) 6A TP MCCB 10KA ICS with starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps
and other fitting parts , 1.0 HP each) (x) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) (xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps)
-
-
-
... More
(xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each) (xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps ) (xiv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each) (xv) 6A DP 10 KA for ON line Monitoring System and two number flow meters (xvi) 16A DP 10 KA for Spare -03 No for PLC board. The above panel includes all kind of MCB , MCCB, MPCB, ENERGY METER , Indication Lights , Selector Switches ,Push Button.
-
-
-
... More
SEWAGE TREATMENT PLANT Supplying, Fabrication ,Instalation, Erection , Testing and commisioning of All Electro Mechanical Parts or Machinery with inter connecting piping and valves ,railing ,Wet Well plateform and M.S.Stair, Complete M.S.Structure for the Vertical Removal of Submercible Pumps with manual operated chain Pully arrangement with complete Testing and Commissioning of Sewage Treatment Plant(STP) for sewage parameter as per Annexure 'B'(Inlet parameter of raw sewage) & Annexure 'C' '(Treated sewage parameter of arboriculture) (DNIT) based on the principle of Suspended Growth with one numbers Membrane Bio Reactor (MBR) having capacity of 75 Kilo Liters Per Day each (75KLD) based on 24 hours of operation for treating domestic sewage from toilets, bathrooms , kitchen waste water etc, received through newly laid sewer network by gravity with all safety equipments, tools and plants to test the parameters of various stages of process as per CPHEEO Manual of Sewerage and Sewage Treatment comprising of- Manual Operated C.I.Sluice valve at Inlet Chamber , SS Coarse Bar Screens, Raw Sewage Pumps with complete piping and valves at wet well cum equalization tank with MBR skid plant made up of M.S.Plate 6mm thick with FRP Coating 5mm thick inside M.S.tanks : Inlet Chamber , Vortex Grit Chamver , Screen Chambers , Manual Control Valves , Stainless Steel(SS) fine screens , equilisation tank, Anoxic Tank with submercible mixer , Aeartion tank , MBR Reactor Tank with submerged Membrane skid, Permeate Pumps VFD opertaed , Air blowers and air grid system, Sludge Recirculation system with pumps piping etc , Hypo dosing pumps and dosing tanks, Sludge storage pvc tank , Filter Press, & filter Press feed screw pumps, Equilisation feed cutter pumps, CIP back wash System with Citric Acid, Hypo Dosing system and back wash water tank, All control valves or Pneumatic Valves or Solinoid Valves, Interconnecting piping with complete fitting parts and valves, Elctrical and instrumentation cables for entire STP, Inspection plateform with ladder, Railing, Over flow pipes , Outside paint work of all M.S.parts , providing fixing of electro magnatic flow meters at Inlet and Outlet of each Skid STP, Pressure Gauges, Hydostatic Pressure Transmitters ,Rota Meters for MBR , Rota Meter for Air Scouring, Float Switches and all measuring instruments, One number treated water on line monitoring system, all as specified and as elaborated below SERIAL wise specifications.MBR controlled by PLC as per given specifications.
1
-
-
... More
INLET CHAMBER CONTROL VALVES & COARSE SCREENS inside Wet Well:-
Providing and fixing of two number Manual operated C.I.Sluice Gate valves 200mm Dia at wet well Inlet Chambers and Providing and fixing of two numbers coarse bar screens made of M.S.Epoxy coated Angle frame 50x50x6mm with Flat size of 50mm wide 8mm thick ,position in vertical face @20mm gap , Over all size of 420 wide ,1100mm Straight Height places at 60 degree angle.
-
-
-
... More
RAW SEWAGE TRANSFER PUMPS with S.S.Piping FROM collection sump to Equalization Tank and equilisation tank to INLET CHAMBER OF MBR PACKAGE PLANT :-Providing & Fixing of Two Nos (One working and One standby)
, Submercible Types with level sensors , non-clog sewage handling Submercible Pumps suitable for solid handing of at least 40 mm dia for raw sewage transfer of capacity : Minimum 5 m3/hr(Cutter pump) and 3.6m, head 10 m (including required suction head). The pump shall have CI casing Stainless Steel impeller, TEFC induction motor of suitable capacity to run on 400/440V, 3 phase, 50 Hz cycles A/C power supply with single phase preventer, dry run protection etc. including pressure gauge, level controller system with stainless steel probes/sensors and float switches for automatic operation, cable, starters, panel, indicators, selector switches etc, complete with other accessories as required.
Note:- Suitable Comman Header with NRV ,Manual Control Valves and complete pipe,bents, flanged joints , S.S nut bolts , rubber jains complete Pipe fitting of S.S.Material up to the Inlet Chamber shall be provided .Casing : Cast Iron IS 210 Gr. FG 260 .Cable gland : Cast Iron IS 210 Gr. FG 260 ,Motor Body : Cast Iron IS 210 Gr. FG 260 Seal cover : Cast Iron IS 210 Gr. FG 260, Coupling : CI,Duck foot bend : C.I.Guide Pipe : SS 304,Lifting chain : SS 304,Fasteners : MS with GI coating The Pumps are to be fitted with multi strand, multi core unarmoured; PVC insulated flexible cable conforming to IS Specifications. The motor of the offered submersible pump shall be as per IS 325 standard. The following safety features shall be provided in pump design.b) Thermal switches to sense increase in temperature of the motor winding.d) Low level cut off through electrode type levelsensor.In auto mode, pump will start at high level and stop at low level and in manual mode athigh level pump is required to start manually and will stop automatically at low level.
-
-
-
... More
These special features give signal to the control panel which trips the motor thereby avoiding further damage to the pump / motor and ensures long trouble free operation of the pump. Control panel with at least 2 Nos. level probes shall be provided.
The pumped flow from the Pumping Station to the elevated Head Works of the Plant shall be taken through a Rising Main designed for peak flow.
The Pumps will have coupling arrangement at discharge end, a guide pipe and a chain for easy removal and lowering of Pumps. The Pumps shall run smooth without undue noise and vibration. Vibration shall be limited as per BS 4675, Part I. The motor shall be as per IS 9283-1995. Motor shall have integral cable parts and the cable entries shall be sealed. Complete rotor shall be balanced dynamically.
-
-
-
... More
Coarse Diffusers inside Wet Well cum Equallization Tank: Providing and fixing of eight numbers coarse bubble diffusers with S.S.Material Air pipe line with all bends
,flanges , control valves ,nuts and bolts from All Air Blowers to Wet Well Air diffusers system. Quantity: One Set for only Wet well.
-
-
-
... More
ANOXIC CHAMBER & MIXER :- Providing and fixing of One number Anoxic Tank & Submercible Mixer of 1.0HP Capacity with complete lifting arragement and submerged cable and required power connection from main STP panel and ON -OFF starter at Mixer site on top of wall. Anoxic tanks will be made of MSEP , 3m lenght x 5.3 height x 2.0m wide , Minimum 6mm thick M.S.Sheet and 5mm thick Epoxy Coating inside with all MS structure bracing channels as per standard engineering practices of shape and dimension . Leak proof welding should done as per IS specifications.Qty:01 set for each skid.
-
-
-
... More
INLET CHAMBER & FINE BAR SCREENS :- Providing and fixing of two number Manual operated C.I.Sluice valves 100mm Dia at Inlet Chambers with fine bar screen MSEP tank and Providing and fixing of two numbers Fine bar screens made of M.S.Epoxy coated Angle frame 50x50x6mm with Flat size of 50mm wide , position in vertical face @6mm gap ,Over all size of 200 wide ,950mm Tapper Height places at 60 degree angle. MOC : of one Inlet Chamber and Two Fine Bar Screen is MSEP Minimum 6mm thick M.S.Sheet and 5 mm thick Epoxy Coating inside. Size of inlet Chamber: 0.6*0.6*0.6 and Size of Fine Bar screen Chamber is 300mm wide , 700mm Height and 1000mm length of each .Qty: two Numbers. Leak proof welding should done as per IS specifications.Qty:01 set for each skid ,Total 1 sets .
-
-
-
... More
VORTEX GRIT CHAMBER UNIT :- Providing and fixing of One number Manual operated Vortex Type Grit Chamber made up of MSEP tank with 100mm dia valve at the bottom of the vortex Grit Chmabers including P/F of one Number G.I.flanged insurtion pipe at the bottom to remove Grit . Vortex tanks will be made of MSEP , 1.0m Dia x 1.9m height , Minimum 6mm thick M.S.Sheet and 5 mm thick Epoxy Coating inside with all MS structure bracing channels as per standard engineering practices of shape and dimension . Leak proof welding should done as per IS specifications.Qty:01 set for skid.
-
-
-
... More
MEMBRANE BIO REACTOR :-Providing and fixing of minimum 180 Sq: m area of PVDF fine membrane with S.S.mounting of membrane Train Fixing from Top inside MBR tank (make QUA). MBR tank made of MSEP, 3m lenght x 4.3m height x 3.0m wide , Minimum 6mm thick M.S.Sheet and 5mm thick Epoxy/FRP Coating inside with all MS structure bracing channels as per standard engineering practices of shape and dimension . Leak proof welding should done as per IS specifications.Qty:01 set for each skid.
-
-
-
... More
AIR BLOWERS with Complete Air Piping Network:- Providing and fixing of Two Numbers for each skid (One working and one stand by) Air Blower twin lobe type blower with motors/pulleys of capacity not less than 110 cum/Hr @ 0.50 WC driven through 'V' belt or directly coupled through flexible coupling to a TEFC motor of suitable capacity suitable for 400/440 volts, 3 phase, 50 cycles AC supply with single phase preventer, starters including rigid one piece CI casing and side plates, anti friction bearings, suction silencer, discharge silencer, anti vibration pads necessary foundation, common base plate, lubricant oil, etc, complete with valves, NRV, rubber flexible complete including sound proof cover as per OEM specification .The blower will be fitted with S.S.Material AIR Pipe 1. Upto Wet Well (40mm dia) 2. Upto MBR ( 40mm dia) 3. Upto Sludge tank ( 40mm dia) 4. upto Aeration Tank Sysytem.( 50mm dia), with required Air Control valves . (length of all pipe as per site plan )Qty:01 set for each skid.
-
-
-
... More
Lateral AIR GRID Piping :- Providing and fixing of Air Grid piping of Header and Lateral Type of MOC - SS 304 should be catered in wet well tank, Aeration Tank , MBR tanks & sludge tank .Lateral Grid will have provision of fixing Air Diffueres with thread joint. Qty:01 set for each skid.
-
-
-
... More
SLUDGE RECIRCULATION TANK :- Providing and fixing of One number Sludge Tank made of MSEP for each skid , 3.0m lenght x 4.0 height x 1.0m wide , Minimum 6mm thick M.S.Sheet and 5 mm thick Epoxy Coating inside with all MS structure bracing channels as per standard engineering practices of shape and dimension . Leak proof welding should done as per IS specifications.Qty:01 set for each skid.
-
-
-
... More
RETURN SLUDGE CUM WASTE PUMPS :- Providing and fixing of Two Numbers (One working and one stand by) submercible type sludge pump 2.0HP motor capcity and minimum head 10m. The pumps shall be made of CI casing, CI Impeller, SS shaft and sleeve, Mechanical seal are connected to a TEFC induction motor of suitable capacity to run over 400/440V, 3 phase, 50 cycles AC power supply mounted on a common base frame with coupling guard, 100 mm dia pressure gauge with GM isolation cock, including all necessary piping, valves, industrial type .It includes the common header made of GI Pipe manifold finished & hot dipped galvanised with flanged ends on other sides and other accessories testing, commissioning complete as required.Both pumps have one delivery line upto Anoxic tank & sludge tank . It includes providing and fixing of Sludge Line Made of S.S.Material of required dia with all bends,Tee and flanges
.Qty:01 set for each skid.
-
-
-
... More
COMPLETE PIPING :- Providing and fixing of all inter-connection piping of S.T.P between pumps, MBR tanks, oulet pipe up to treated water tanks . The material of Piping will be S.S only wherever submerged or non submerged pipes as per colour code marked direction of flow and type of sewer within battery limit including tees, bends, flanges, nut bolt, gasket, etc. including necessary primary and secondary supports with masonry work/structural steel work all as required and as specified.All welding works to be done as per I.S.Specification including leak proof test and fine finishing.Qty:01 set for each skid. VALVES & WATER METER :- Providing and fixing of all Valves of 75 KLD capacity of STP as per size and material of STP piping including in One lot such as gate valves/butterfly valves/NRV/Air Release valves of suitable size complete all as specified and directed.. Two Digital Water meter ultra sonic type need to be provided at Inlet of STP after Wet Well and Outlet of Treated water pump line. The reading of water meter also displayed on SCADA screen to control the process.Qty:01 set for each skid. CLEAN IN PROCESS (CIP) with DOSING Tanks : Providing and fixing of Two number
C.I.P Pumps 1 HP each with Two Numbers Citric Acid Dosing Pumps with complete set of acid dozer comprising of 500 Ltrs Cap.each HDPE (Chemical grade) tank with inlet/outlet connection pump of adjustable capacity for dosing of acid solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVC material of 10mm dia up to memebrane line. Providing and fixing of pipe line and valve arragement for connecting two number Hypo Dosing System with complete set of hypo dozer comprising of 500 Ltrs Cap.each HDPE (Chemical grade) tank with inlet/outlet connection pump of adjustable capacity for dosing of chlorine solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVC
material of 10mm dia up to memebrane line.ty:01 set for each skid.
-
-
-
... More
HYPO DOSING with DOSING Tanks : Providing and fixing of Two Hypo Dosing Pumps with complete set of Sodium Hypo Chloride solution dozer comprising of 1000 Ltrs Cap.each HDPE (Chemical grade) tank with inlet/outlet connection pump of adjustable capacity for dosing of chlorine solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVC material of 10mm dia up to Chlorination Start point. One Mixer is also part of supply and fitting.Qty:01 set for each skid.
-
-
-
... More
PERMEATE PUMPS FOR MEMBRANE :- P/F of Two Nos: (One working and one stand by) Horizontal centrifugal mono block type pumps as PERMEATE pump with capacity not less than 4.0 cum/Hr and minimum head mWC 20m. The pumps shall be made of C.I casing,C.I /Noryl Impeller, SS shaft and sleeve, Mechanical seal are connected to a TEFC induction motor of suitable capacity to run over 400/440V, 3 phase, 50 cycles AC power supply mounted on a common base frame with coupling guard, pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design including all necessary piping, valves, industrial type electronic type electronic level indicators with stainless steel probe/sensors for automatic operation, GI manifold finished & hot dipped galvanised with flanged ends on other sides and other accessories incl canopy of suitable size made of angle iron 40 x 40 x 6 mm and Galvalume sheet 0.5mm thick, testing, commissioning complete as required. It also includes P/F of VFD system to control the suction and back wash period of the MBR system.Qty:01 set for each skid.
-
-
-
... More
MBR CONTROL VALES :- Supply & Fitting of Minimum Six Numbers Pneumatic control Valves controled by PLC programming with S.S piping flanged and welded with appropriate bends and T joints .It also includes supply and fixing of Rota Meter and Hydrostatic Pressure Transmitter.Qty:01 set for each skid.
-
-
-
... More
AIR COMPRESSOR :- Supply and Fitting of One No . AIR COMPRESSOR MAKE ELGI , CAPACITY 150LPH , 2 HP motor with required flow control valves and piping upto required valves of MBR process.Qty:01 set.
-
-
-
... More
DISINFECTION TANK :- Providing and fixing of One number Disinfection Tank made of MSEP , 3m lenght x 4.0 height x 1.0m wide with two baffle walls per standard engineering practices of shape and given dimension . It also Includes provision of Hypo Dosing System from hypo dozer comprising of 500 Ltrs Cap.each HDPE (Chemical grade) tank with mixer & inlet/outlet connection pump of adjustable capacity for dosing of chlorine solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVC material of 10mm dia up to Disinfection Tank. MOC : Minimum 6mm thick M.S.Sheet and 5 mm thick Epoxy Coating inside with all MS structure bracing channels as per standard engineering practices of shape anddimension . Leak proof welding should done as per IS specifications.Qty:01 set for each skid.
-
-
-
... More
FILTER PRESS SCREW PUMPS :- P/F of Two Nos (one working and one stand by) screw type pumps for feeding the sludge from Sludge Tank to Filter Press. pumps should be of CI casing and bronze impellor along with motor of capacity not less than 0.5 Cum/Hr, 10 mtr head. Pump should be provided with isolation cock, isolation valve, NRV on delivery line, mechanical seal, vibration pad, drain valve inc. 150mm dia pressure gauge, suitable vibration eliminator pads of approved design. Motor to be suitable for 400/440V, 3 phase, 50 cycles AC power supply with single phase preventer, starters, industrial type electronic level indicators ncluding all necessary piping, valves and other accessories and concrete foundation, complete all as specified and directed. It also includes all piping of required dia (S.S material) from Sludge Pump to Screw Pumps and Delivery Line from Screw Pumps to Filter Press with pumps headers , valves , NRV , Bends , Flanges etc complete in all respect.Qty:01 set for each skid
-
-
-
... More
FILTER PRESS (Hydraulic Operated) :- Supply, installation and commissioning of one number filter press with proper foundation fixing accessories, sheds, inspection arrangement and with provision of proper collection of sludge and its disposal. The specification of filter press is Size 600mmx600mm, 15 plates, per batch operation, with hydraulic press system and motor 3 phase 440v 50hz motor or higher capacity with suitable DOL starter, single phase parameter including cover shed made of structural steel posts with sufficent space all round for inspection (min 1 mtr), internal height 2.0 mtr above the equipment or 3 mtr overall height whichever is more , plinth height min 45 cm made of PCC 1:2:4 prepatinted Galvalume aluminium zinc coating GI based Plain stel sheet 0.50mm thick of any colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, Cover shed made of structural steel posts with suffcient space allround for inspection (min 1 mtr), internal height 1.5mtr above the equipment,prepainted Galvalume aluminium zinc coating GI based plain steel sheet 0.05mm thick of any colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, the disposal of the filter cake will be done with hand one wheel operated trolly up to the site given by Eng-in-charge. Qty:01 set for each skid.
-
-
-
... More
AIR MIXING OF SLUDGE TANK: Providing and fixing of Four numbers coarse bubble diffusers with S.S.Material Air pipe line with all bends ,flanges , control valves ,nuts and bolts from Air Blowers to Sludge Tank complete in all respect.Qty:01 set for each skid.
-
-
-
... More
COMPLETE PIPING :- Providing and fixing of all inter-connection piping of S.T.P between pumps, MBR tanks, oulet pipe up to treated water tanks . The material of Piping will be S.S only wherever submerged or non submerged pipes as per colour code marked direction of flow and type of sewer within battery limit including tees, bends, flanges, nut bolt, gasket, etc. including necessary primary and secondary supports with masonry work/structural steel work all as required and as specified.All welding works to be done as per I.S.Specification including leak proof test and fine finishing.Qty:01 set for each skid.
-
-
-
... More
VALVES & WATER METER :- Providing and fixing of all Valves of 75 KLD capacity of STP as per size and material of STP piping including in One lot such as gate valves/butterfly valves/NRV/Air Release valves of suitable size complete all as specified and directed.. Two Digital Water meter ultra sonic type need to be provided at Inlet of STP after Wet Well and Outlet of Treated water pump line. The reading of water meter also displayed on SCADA screen to control the process.Qty:01 set for each skid
-
-
-
... More
CLEAN IN PROCESS (CIP) with DOSING Tanks : Providing and fixing of Two numberC.I.P Pumps 1 HP each with Two Numbers Citric Acid Dosing Pumps with complete set of acid dozer comprising of 500 Ltrs Cap.each HDPE (Chemical grade) tank with inlet/outlet connection pump of adjustable capacity for dosing of acid solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVC material of 10mm dia up to memebrane line. Providing and fixing of pipe line and valve arragement for connecting two number Hypo Dosing System with complete set of hypo dozer comprising of 500 Ltrs Cap.each HDPE (Chemical grade) tank with inlet/outlet connection pump of adjustable capacity for dosing of chlorine solution (10 LPH) with testing and commissioning complete.It also includes Delivery pipe line of CPVmaterial of 10mm dia up to memebrane line.ty:01 set for each skid.
-
-
-
... More
COMPLETE Electrical and Electronics parts Cabling and wiring of all specified units of complete MBR STP :- Providing and fixing of all inter-connection wiring / cabling of STP machinery parts like pumps, Motors , Pneumatic Valves , Sensors , PLC control panel connection to Computer Monitor for SCADA Operation , Air compressors , Air Blowers Motors , CIP system , Chlorination System , Permeate pump with VFD drive cabling and control valves , Anoxic Mixer etc. complete in all respect including cable trays ,earthing of entire plant. The feed flow rate of each MBR is typically controled to maintain constant level in the membrane tank by controling VFD of premeate pump.
Provision of removing air from the permeate pipe should be made by installing adequate DEgassing Pot and isolating atomatic controled valve and reverse direction of flush air.Qty:01 set for each skid.
-
-
-
... More
Fabrication and fixing of M.S.Plateform ,Ladder , Railing at Coarse .Screen chamber inside Wet Well MOC: 40mm dia M.S.Pipe , Channels ,M.S.Plate ets complete in all respect to provide access to the coarse bar screen cleaning and operation of control valves as per drawing it also includes red oxide and enamel paint on all surfaces of M.S.Members.Qty: One Set only.
-
-
-
... More
Plateform for MBR reactor :Made of MS Fabricated Angle channel framed with M.S.Sheet 8mm thich plateform on one side of MBR tank for inspection with MS.Ladder. Width of minimum 750mm will be provided.It also includes two coats of paint work as per IS Specifications .Qty:01 set for each skid.
-
-
-
... More
Fabrication and fixing of M.S.Structure for the provision of Sewer Pumps Lifting arrangement from wet well to top ground level for maintenance purpose . It includes Grouting of Anchour Bolts on both sides of the Vertical Members of ISMB 300X140 with suitable two numbers PCC foundation, one manual type chain pully( One Ton Capacity ) to be fix on the top of Horizontal channel so that Pumps can be lifted up to the top Plateform , Four guide pipes also to be provided and fixed at the Bottom of Wet Well by groutning to base . One moving S.S.Bush (100mm long 20mm thick )to be fix on top of Guide Pipe connected to Submercible Pump body by Clamp .Gap between guide pipe and moving bush shold be at least 10mm . The top of bush one handle is provided to tie up with the chain of Pully at top . It includes red oxide and Bitumen paint on all surfaces of M.S.Members - Qty: One Set only.
-
-
-
... More
P/F Two Numbers of Earthing for each Skid with 600x600x 6.0 mm G.I .earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed.Qty:01 set for each skid. Note :- G.I. Strip more than 7.5 mtr will be measured and paid separately.
-
-
-
... More
PVC STORAGE TANK : Providing and fixing of One numbers Triple Layers 20000 liter capacity , Two Number 2000Liter capacity and One Number 10000liter capacity , One Number 2000 liter capacity flushing tank for MBR PVC material factory made with inlet and outlet arrangement to be placed on 200mm thick RCC plateform .( The above quantity is for one skid plant).Qty:01 set for each skid.
-
-
-
... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm G.I strip ,complete all as specified and directed.Qty:01 set for each skid.
-
-
-
... More
Providing and fixing of PLC - SCADA for two numbers MBR 75 KLD capcity Specifications as per Annexure -I attached ) Low voltage panel (LV )PANEL . Suitable Power contractor as per load make ABB AX09-30-10-80 rated operation voltage 690V AC ,21A . Thermal overload relay ABB Class 20/22 , Air Circuit Breaker , MicroProcessor Based Overcurrent releases(MBOR), Machinery Drive ACS 380 with software , General purpose Drive ACS 580 , Aapp Cables , MCB .Qty:01 set
1
-
-
... More
Lumpsum price worked out by the contractor for Excavation and Earth work as listed in Schedule 'A' Part-II.
1
991090
-
... More
Lumpsum price worked out by the contractor for Road, Path & Culvert as listed in Schedule 'A' Part-III.
1
1718344
-
... More
Lumpsum price worked out by the contractor for Protective works as listed in Schedule 'A' Part-IV.
1
3646701
-
... More
Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-V.
1
160224
-
... More
Lumpsum price worked out by the contractor for Security fencing and steel gate works as listed in Schedule 'A' Part-VI.
1
210409
-
... More
Lumpsum price worked out by the contractor for External Electrical Supply Works as listed in Schedule 'A' Part-VII.
1
270860
-
... More
Lumpsum price worked out by the contractor for External Water Supply Works as listed in Schedule 'A' Part-VIII.
1
667061
-
... More
Supply and fix PPR Gate Valves (Brass Insert) bore sizes 90 mm outer dia complete all as specified.
4
-
-
... More
Supply and fix PPR Gate Valves (Brass Insert) bore sizes 75 mm bore pipecomplete all as specified.
2
-
-
... More
M&L for cutting existing GI/CI any size of pipe line making new connection for PPR pipe including short pieces, inserting tees, bends, sockets, union etc with existing water line all as specified and as directed.
1
-
-
... More
M & L for construction of valve chambers of internal size not less than 1000mmx1000mmx1050mm with 15 cm thick soild concrete block masnory, block casted using PCC 1:3:6 type C-1 surface mix built in cement and sand mortar 1:4 , 10mm thick plaster to thick internal surface and external upto 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick, MS steel cover including 40x40x6mm MS angle frame embedded in 150mm thick PCC 1:2:4 type B-1, with 25x6mm flat iron hold fast, handles, hinges with locking arrangements, applying one coat of red oxide primer ant two coat of synthetic enamel paint to all steel surface and earth work in any type of soil & disposal of surplus soil to a distnace not exceeding 50m complete all as specified.
4
-
-
... More
All as per above item No. 14 but size 600mm x600mmx600mm.
50
-
-
... More
Supply, install, testing and commissioning of centrifugal pumpset of capacity 2HP/1.6 KW,3phase, 415 Volts, 50 Hz,2900 RPM, min Head rang-25 Mtrs at 312.50 L.P.M flow rate, horizontal type, inlet & outlet size -50mm can withstand wide voltage fluctation from 200-400 Volts, designed to prevent overloading and motor burntout dynamically balanced rotating parts to ensure minimum vibrations during running, CED coated cast iron components for rust free & longer life. and motor ody and delivary casing made of material -cast iron, shaft-stainless steel including, NRV of suitable size, cabel complete all as specified . (01 set including 02 Nos of pumps one working & one standby)
2
-
-
... More
Constructing brick masonary manholes with sub class 'B' bricks in cement mortar 1:4 curved on plan exc 6m mean radius type-A of size 800mm x 900mm and depth 0.60 mtr to 0.90 mtr, with FPS class designation 75 in CM 1:4 inside cement plaster 15mm in CM 1:3 with WPC, conforming to IS 12592 fixed in cement concrete 1:2:4 20 mm graded crushed stone aggregates including centering shuttering all as specified and directed.
111
-
-
... More
Constructing brick masonary circular type manholes with sub class 'B' bricks in cement mortar 1:4 curved on plan exc 6m mean radius type-B of 900 mm internal dia and depth exc 0.90 mtr to 1.65 mtr, with FPS class designation 75 in CM 1:4 inside cement plaster 15mm in CM 1:3 with WPC, conforming to IS 12592 fixed in cement concrete 1:2:4 20 mm graded crushed stone aggregates including centering shuttering all as specified and directed.
19
-
-
... More
Constructing brick masonary circular type manholes with sub class 'B' bricks in cement mortar 1:4 curved on plan exc 6m mean radius type-C of 1200 mm internal dia and depth exc 1.65 mtr to 2.30 mtr, with FPS class designation 75 in CM 1:4 inside cement plaster 15mm in CM 1:3 with WPC, conforming to IS 12592 fixed in cement concrete 1:2:4 20 mm graded crushed stone aggregates including centering shuttering all as specified and directed.
1
-
-
... More
Providing and laying Rodent Repelent SN-8 DWC ID (HDPE BLACK) Pipe 150mm dia, with full coupler and rubber ring confirming to IS:16098-2 including testing of joints, commissioning etc complete Make: Tirupati/Bestech/Astral/Ashirwad.
553
-
-
... More
Providing and laying Rodent Repelent SN-8 DWC ID (HDPE BLACK) Pipe 200mm dia, with full coupler and rubber ring confirming to IS:16098-2 including testing of joints, commissioning etc complete Make: Tirupati/Bestech/Astral/Ashirwad.
737
-
-
... More
M & L for cement concrete type C-2 (1:3:6) using 40 mm graded crushed stone aggregate as in foundation fillings and mass concrete complete all as specified and directed.
5
-
-
... More
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe 225 mm all as specified.
40
-
-
... More
Providing orange Colour safety foor rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS-1786 having minimum cross section as 23 mm x 25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between producted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance tedt as per specificatiobs and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as specified.
1451
-
-
... More
Providing & Fixing FRP / GRP manhole covers 60 mm dia medium duti 2.50 Tons load test with frame of spefified sizes / colour shall be conforming to IS1726 & BS EN 124 standards, colour shall be as per direction of engineer in charge and manhole cover shall be engraved with clients name confirmed with engineer in charge complete with accessories in all respects nothing will be paid separatel. Make : JSN/Dudhu/HP/Pillon
131
-
-
... More
Comprehensive maintenance of STP and SCADA system
-
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during defect laibility period of Ist year during Phase II (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 8% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during defect laibility period of IInd year during Phase III (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 8% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase IV (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 9% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase V (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 9% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase VI (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 9% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase VII (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 9% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase VIII (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 10% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase IX (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 10% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase X (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 10% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase XI (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 10% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
11
-
-
... More
Operation and comprehensive maintanance of STP and SCADA system during Phase XII (item no 1.01 to 2.30 & 3.00 of BOQ of the work) for amount of STP of amount. Not exceed the 10% of items NO 1.01 to 2.30) NOTE (i) The contractor shall follow the term & condition of E-in-C's branch policy no 10/2023 issued vide letter no A/95533/SCADA Sewage/Pol/E2W(PCC) dated 21 Jul 2023 (ii) Contractor to provide month-wise breakdown details of the same.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%