Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date23 Dec 2024
Closing Soon6 Jan 2025
Tender Amount₹ 27,17,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed

62.57

-

-

... More
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified.

38.39

-

-

... More
Well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed

2.84

-

-

... More
PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in foundations, filling, mass concrete and sub base of floor, complete all as specified & directed.

1.37

-

-

... More
PCC 1:2:4 nominal mix, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.

0.13

-

-

... More
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately).

55

-

-

... More
XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size150 Sqmm 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.(Earth work, brick protection and sand cushioning shall be measured and paid for separately).

45

-

-

... More
All as per item No. 10 above but cross-sectional area 70 sqmm, 3.5 core

105

-

-

... More
All as per item No. 10 above but cross-sectional area 35 sqmm, 3.5 core

375

-

-

... More
All as per item No. 10 above but cross-sectional area 16 sqmm, 4.0 core

250

-

-

... More
All as per item No. 10 above but cross-sectional area 16 sqmm, 2.0 core

160

-

-

... More
All as per item No. 10 above but cross-sectional area 10 sqmm, 2.0 core

570

-

-

... More
Steel tubular swaged poles complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-55 (11m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with fluorescent yellow paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (Earth work, and PCC shall be measured and paid for separately).

2

-

-

... More
Air break gang operated switch with 12 insulators outdoor type, triple pole, mounted on 12 insulators, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS channel, HT post type insulator contacts of copper alloy, high pressure, heavy duty contact assembly operating rod 20mm dia GI pipe, medium grade, complete including drop out fuses conforming to IS-1818, rated voltage 11 KV and for current rating 400 Amp including taking down old GOD of any type, shape & size, complete all as specified.

1

-

-

... More
Lightning arrestors (set of three) metal oxide surge type (ZnO) complete with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts complete all as specified and as directed.

1

-

-

... More
Anit climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed. Note :- Clamps will be measured separately.

0.1

-

-

... More
Danger notice plate of size 25 x 20 cm, made of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with and including mild steel clamps, bolts and nuts of approved size for HT poles, complete all as specified.

2

-

-

... More
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer including preparation of surfaces, complete all as specified & directed.

2.4

-

-

... More
Construction of Platform for installatiom of Transformer of size 3mX2.5mX1.25m with brick work in cement mortar 1:6 earth filling,300 mm thick PCC 1:5:10 type E2, 100 mm thick PCC 1:2:4 type B1 using 20 mm crushed stone aggregate in florring , including XPM fencing (weight not less than 4 kg/sqm) with support of angle iron frame 50 x 50 x 6 mm at four corners with gate with locking arrangements and all steel surfacces well treated with two coats of synethic enamel paint over a coat of red oxide primer complete all as per Drg No CEUZ/TD-1129/96 sheet 1/2

1

-

-

... More
GI tubing ‘light grade’ with all fittings, laid in trenches or under road crossing as protection pipe, bore of pipe 80 mm, complete all as specified.

20

-

-

... More
All as per item No. 23 above but for bore of pipe 50 mm

24

-

-

... More
All as per item No. 23 above but for bore of pipe 40 mm

18

-

-

... More
Outdoor type cable terminal box (heat shrinkable) suitable for 11 KV 3 core 50 to 95 Sqmm XLPE HT cable including all jointing material, fixing with suitable clamps made out of FI 50x6 mm including nuts, bolts and washers, testing and commissioning, complete all as directed.

4

-

-

... More
Supply,install,testing and commissioning outdoor type step down transformer 11000 volts/433 volts (at no load) ,AC , 3 phase 50Hz capacity 160 KVA corec type double copper wound , oil immersed , naturally cooled, oil natural, air natural (ONAN) with external cooling fins , delta connected on primary side (HV) ) star connected on secondary side (LV) in accordance with vector symbol , Dyn 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at +5% to -10% (at 2.5% each step) HV side to be changed by means of hand operated off load tap changer gear. The Transformer shall be IS 1180Part 1:2014 (level -2) and BEE certied and shall comprise of the following :- (a) cable end box on HT side suitable for 95sqmm 3 core XLPE cable (b) cable end box on LV side suitable for 150sqmm 3.5 core XLPE cable (c)Oil conservator with filter type frain valve and oil level gauge (d)dehyderating breather with first fill dehyderating agent (silica gel) (e) explosive vent (f)Thermometer pocket on tank cover (g)one no 100mm dia , dial type thermometer , vapour pressure type , having range 0-120 degree celcius with metal guard having maximim perimeter reading , temperature indicator with resisting device for transformer.

1

-

-

... More
(h) Two earthing terminals on tank cover to facilate fixing of 32x6mm copper earth strip for earthing of neutral body. (i)Rating plate and terminal making plate (j)oil level gauge (k)oil drain/filter valve (l) lifting lugs (m) Oil filling hole with cap / plug with connecting plate complete (n) air release valve plug (o)Four plain solid cast steel deattachable rollers (p)extra bushing for neutral , outside the LT cable box for providing independent earthing for Neutral (q)First filling of new and unused transformer oil IS:35/93(4th revision), marked (Make:Savita/Poweroil) filtered and tested upto 40KV dielectric strength at 2.5mm air gap between testing.

-

-

-

... More
Supply, installation, commissioning and testing of servo controlled Voltage Stabiliser fully automatic operation, unbalanced type (individual phase control), copper wound 415 V, 50 Hz confirming to BIS 9815 : Part 1 : 1994 reaffirmed 2009, IP-45, three phase naturally oil cooled, indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilised at 415 volt with accuracy ± 1.0% and speed of correction 15 volts per second of capacity 160 KVA including first filling of transformer oil having dielectric strength not less than 150 KV as per IS:335, 0-500 volts voltmeter, arrangment to check input voltage and output voltage, RYB indication lamp, high & low voltage cut off system, single phase preventor, time delay relay, servo byepass switch, overload & short circuit trip system, ammeter, oil level gauge& capacity overload 20% overload for one hour etc., complete all as specified & directed.

1

-

-

... More
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 500 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (350Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- Main Panel

1

-

-

... More
(a) MCCB 350 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) On Load changeover switch 160 amp 4 pole, 415 V, 50 Hz- 01 Nos (c) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Outgoing) (d) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 03 Nos (outgoing) (e) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 03 Nos (outgoing) (f) Multifunctional meter(Volt, Ampere, Frequency, Pf) Make L&T (WL4110210000) (g) CT as per reqd size, Make AE (h) Indicator lamp RYB -- 03 NOS (j) Danger notice Plate duly rivetted on front - 01 No. (k) Panel internal wiring for control circuit with copper cable 2.5 Sqmm.(Make:Savita/Poweroil) filtered and tested upto 40KV dielectric strength at 2.5mm air gap between testing. (l) Earth terminal - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from AGE(I) before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 350 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (160Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following (Loc: Offrs Mess)

1

-

-

... More
(a) MCCB 160 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) On Load changeover switch 100 amp 4 pole, 415 V, 50 Hz- 01 Nos (c) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Outgoing) (d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) MCB 63 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 02 Nos (outgoing) (f) MCB 32 amps, 02 pole,415 volts, 50 hz AC supply with breaking capacity 10 KA - 04 Nos (outgoing) (g) Multifunctional meter(Volt, Ampere, Frequency, Pf) Make L&T (WL4110210000) (h) CT as per reqd size, Make AE (j) Indicator lamp RYB -- 03 NOS (k) Danger notice Plate duly rivetted on front - 01 No. (l) Panel internal wiring for control circuit with copper cable 2.5 Sqmm (m) Earth terminal - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from AGE(I) before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 200 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (100Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following (Loc: FRI, JCO Living, Near OR Cook house)

3

-

-

... More
(a) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) On Load changeover switch 63 amp 4 pole, 415 V, 50 Hz- 01 Nos (c) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Outgoing) (d) MCB 32 amps, 2 pole, 415V, 50Hz, AC Supply with breaking capacity 10 KA (Adjustable thermal & magnetic release) - 06 Nos (outgoing) (e) Multifunctional meter(Volt, Ampere, Frequency, Pf) Make L&T (WL4110210000) (f) CT as per reqd size, Make AE (g) Indicator lamp RYB -- 03 NOS (h) Danger notice Plate duly rivetted on front - 01 No. (j) Panel internal wiring for control circuit with copper cable 2.5 Sqmm (k) Earth terminal - 02 Nos. NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from AGE(I) before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.

-

-

-

... More
Earth continuity conductor passing through PVC Conduit of size 40 mm main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 32x6 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip of size 32x6 mm (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.

14

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.