Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Oct 2024
Closing Date8 Nov 2024
Tender Amount₹ 38,00,000 
Notes
Download

Costs

Summary

Repair Replacement And Maintenance Of External Electric Supply Work And Misc Connected Items Of Hq 11 Sect And Its Rr Units And Also Including Transformer Servicing God Vcb Battery Bank Street Security Lights At Ramban Banihal Under Age (i) Bha

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & Labour for rewinding with supper enameled double paper covered copper strip for LV (11/0.433KV) winding having existing size and giving proper insulation and de-moisturizing before assembling the winding core and including primary testing, ratio testing, no load testing, core insulation testing and setting connection of tape changer including taking out unserviceable winding wire complete all as specified and as directed.

95

-

-

... More
De-hydration/ filtration of transformer oil by hiring on line filtration plant to achieve di-electric strength not less than minimum 50 KV including following work services :- (a) Removal of all suspended particles such as dust, rust, scales, collided carbon oxidation sludge etc upto 1 micron. (b) De-hydration of transformer oil under vaccum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level NOTE : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately as "Supply only" (iii) Conducting field testing of di-electric strength of the transformer oil before and after filteration (iv) Checking the megger/earth resistance values with battery operated megger of 5 KV

1800

-

-

... More
Material & Labour for Filling / topping of new transformer oil having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength not less than 60 KV all as specified and directed by the Engineer-in-Charge

600

-

-

... More
Supply and fixing of breather assembly of Transformer incl silica gel upto 250 KVA transformer as per existing make and type 500 Gm complete all as specified and as directed.

1

-

-

... More
Supply and fixing brass terminal stud 12 mm with nuts, check nut, oil seal and washer for HV side of transformer up to 250 KVA transformer complete all as specified and as directed.

3

-

-

... More
Supply and fixing brass terminal stud with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) up to 250 KVA transformer complete all as specified and as directed.

4

-

-

... More
Supply and fixing bushing of HV side as per existing size/Model of the capacity up to 250 KVA transformercomplete all as specified and as directed.

4

-

-

... More
Supply and fixing bushing of LV side as per existing size/Model of the capacity up to 250 KVA transformercomplete all as specified and as directed.

4

-

-

... More
Material & Labour for painting of transformers capacity up to 250 KVA including HV/LV connection box with one coat of synthetic enamel paint by using spray painting method including cleaning of existing surface of all dirt and greasy materials alongwith marking of SM/MES Nos with sticker letters n. exc 2 cm height at appropriate places complete after isolating the transformer from the electric supply and to be earthed all as specified and as directed.

2

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 11000 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 95 Sqmm 3 core , 11000 volts, grade including taking down uunserviceable cable all as specified and as directed.

130

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 95 Sqmm 3.5 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

150

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 50 Sqmm 3.5 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

330

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 35 Sqmm 3.5 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

550

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 25 Sqmm 4 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

180

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 16 Sqmm 4 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

300

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 16 Sqmm 2 core , 1100 volts, grade including taking down unserviceable cable all as specified and as directed.

330

-

-

... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 16 Sqmm Solid Conductor cable flat or circular. all as specified and as directed.

180

-

-

... More
Supply & fixing in replacement switch air break, gang operated, triple pole, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assembly, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS:1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified & directed.

6

-

-

... More
Supply & fixing in replacement disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, complete all as specified & directed.

18

-

-

... More
Material & labour for painting to existing steel tubular HT poles, 11 Mtr long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.

28

-

-

... More
Material & labour for painting to existing steel tubular LT poles, 09 Mtr long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.

52

-

-

... More
Supply & fixing in replacement of aluminium conductor steel reinforced (ACSR) of any size for HT/LT overhead lines on steel tubular poles/PCC poles, stretching without kinks and bends including binding wire suitable cross section (but not less than 16 SWG), complete all as specified & directed.

0.7

-

-

... More
Supply & fixing in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint

1.2

-

-

... More
Material & labour for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified & directed.

3

-

-

... More
Supply & fixing in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32mm x 6mm to connect earthpit to electrical equipment room, complete all as specified & directed.

10

-

-

... More
Material & labour for earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified & directed.

3

-

-

... More
Supply & fixing in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room, complete all as specified & directed.

14

-

-

... More
Supply & fixing in replacement lightening arrestor, expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature below - 10 degree C to 50 degree C suitable for surge discharge capacity 65 KA, 11000 volts grade conformign to IS-4350 including all fittings, complete all as specified & directed.

7

-

-

... More
Supply & fixing in replacement of MCCBs 63 amps, 4 pole, breaking capacity 16 KA, 415 volts, AC including taking down old unserviceable MCCBs, complete all as specified & directed.

12

-

-

... More
Supply & fixing in replacement of MCCBS 100 amps, 4 pole, breaking capacity 16 KA, 415 volts, AC including taking down old unserviceable MCCBS, complete all as specified & directed.

9

-

-

... More
Supply & fixing in replacement of of MCCB 160 Amps 4 pole 36 KA, G frame, fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, glan etc complete including taking down old all as specified and as directed.

8

-

-

... More
Supply & replacement of of MCCB 200 Amps 4 pole 36 KA, G frame, fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, glan etc complete including taking down old all as specified and as directed.

5

-

-

... More
Supply & fixing in replacement of of MCCB 250 Amps 4 pole 36 KA, G frame, fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, glan etc complete including taking down old all as specified and as directed

8

-

-

... More
Supply & replacement of of MCCB 400 Amps 4 pole 36 KA, G frame, fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, glan etc complete including taking down old all as specified and as directed.

4

-

-

... More
Material & labour cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 sqmm including testing and commissioning & taking down old unserviceable cable jointing kit, complete all as specified & directed.

8

-

-

... More
Supply & fixing cable jointing kit for LT 1.1 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 95-120 sqmm all as specified and as directed.

8

-

-

... More
Supply & fixing in replacement of street light fitting 60 Watt LED made up of pressure die cast aluminum hosing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable street light fitting all as specified and as directed. Make: Havells / Wipro / Philips / Crompton

130

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of poles/cable,stay assy etc and getting out soft/loose of soil complete all as specified and as directed by Engineer-in-Charge

425.93

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation of poles/cable,stay assy etc and getting out soft/loose of soil complete all as specified and as directed by Engineer-in-Charge

0.16

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layers complete all as specified and directed by Engineer-in-Charge

241.98

-

-

... More
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge

184.09

-

-

... More
Supply and laying dry river sand laid in trenches as cable cushioning 80mm below and 150mm above the cable and punned to 180mm and covering all as directed. Note: Punned qty will be measured and paid.

50.54

-

-

... More
Supply & Laying brick covering with width equil to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.

8.17

-

-

... More
Laying only old brick over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable all as directed.

4556

-

-

... More
Material & Labour for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) for foundation of pole/stay including from work etc all as specified and directed.

2.12

-

-

... More
Material and labour for GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) all as specified and as directed.

73

-

-

... More
Supply & Fixing in repair of connection for security light/red/green indication light with cable of size 1.5 sqmm x 3 core PVC insulated unsheathed FRLS copper cable through pole , complete all as specified and as directed.

260

-

-

... More
Supply & fixing in repair decorative gate light made up of high grade unbrakable polycarbonate material suitable for and including 15W LED lamp B22 base. Mounting pole dia 40/60mm dia, Dimension width 200mm and height 235mm. Make : Havells cat part No CORALMINIPT15WLED830PSYATOPC

14

-

-

... More
Supply & fixing A unique LED flood light luminaries 70 W, 230 Volts, new generation energy saving & environmental friendly long life versatile pressure die-case aluminium roadway luminaire, IP65 protection wtih high power LEDs as light source and electronic driver including making connection with PVC copper conductor of suitable size, complete all as specified and as directed. Make: Havells Cat Part No JETASTURDYFL070WLED757SSYMLTG or tchno commercially equivalent in Crompton/Wipro/PHillips

26

-

-

... More
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS-2713 Part-I to III 1980, complete with 6mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.35 metre above PCC coping in black and white strips 05 Nos each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable poles all as specified and directed.

4

-

-

... More
Material & Labour testing & Commissioning of LT pannel frame CPRI approved, indoor type,factory made fabircated to CRCA sheet of with min 1.4 mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of following parts. Incomer MCCB (a) MCCB 250 Amps FP 36 KA - (adjustable thermal and magnetic release) - 02 Nos Outgoing MCCB (b) MCCB 200 Amps FP 36 KA - (adjustable thermal and magnetic release) -02 Nos (c) MCCB 160 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 No (d) MCCB 63 Amps FP 16 KA - (adjustable thermal and magnetic release) - 02 No (e) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 400 Amps all as required (f) Indication lamps for R, Y, B - 1 Nos (g) Digital voltmeter 0-500 volts with selector switch - 01 Set (h) Digital ammeter with CT's of suitable ratio & selector switch 0-440 A cap- 01 Set (j) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable. (k) Front operated on load change over switch 400 amps.-01 No (l) Lock pedestal - 01 No Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear/ Power Control Make of MCCB/Change Over : L&T / Legrand / Schneider / Havells/C & S Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO

1

-

-

... More
Supply & fixing in replacement of Bus bar Panel, Size:0.8x0.4x0.4 Mtr, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding.

14

-

-

... More
Aluminium cable Lugs(connectors) for fixing / tightining of electric cable 95Sqmm alongwith nuts and bolts for tightining complete all as specified and as directed

56

-

-

... More
Aluminium cable Lugs(connectors) for fixing / tightining of electric cable 50Sqmm alongwith nuts and bolts for tightining complete all as specified and as directed

72

-

-

... More
Aluminium cable Lugs(connectors) for fixing / tightining of electric cable 35Sqmm alongwith nuts and bolts for tightining complete all as specified and as directed

96

-

-

... More
Aluminium cable Lugs(connectors) for fixing / tightining of electric cable 25Sqmm alongwith nuts and bolts for tightining complete all as specified and as directed

120

-

-

... More
Disconnecting defective out door/indoor transformers of capacity up to 160 KVA from HT/LT side, taking out complete transformer oil, storaing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration/filtration if required (to be paid separately) and necessary repairs re fixing complete core assembly fixing the top cover and complete core assembly fixing the top cover and re-installation complete all as specified and directed. Note : (a) Pole mounted transformer lowering and taking down the same from two /four pole structure to ground carefully & rate will be considered in the quoted rate. (b) In case of major repairs/replacement in transformer which can not be undertaken at site the transformer shall be shifted at civil workshop and the cost shall be paid separately under relevant items. (c) Cost of dehydration/filteration and other necessary repairs shall be measured and paid separately under relevant item. Contractor shall bring the mechanic at site for first inspection of the transformer after that transformer shall be shifted at workshop complete all as directed by Engr-In-Charge.

2

-

-

... More
Disconnecting defective out door/indoor transformers of capacity 250 to 315 KVA from HT/LT side, taking out complete transformer oil, storaing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration/filtration if required (to be paid separately) and necessary repairs re fixing complete core assembly fixing the top cover and complete core assembly fixing the top cover and re-installation complete all as specified and directed. Note : (a) Pole mounted transformer lowering and taking down the same from two /four pole structure to ground carefully & rate will be considered in the quoted rate. (b) In case of major repairs/replacement in transformer which can not be undertaken at site the transformer shall be shifted at civil workshop and the cost shall be paid separately under relevant items. (c) Cost of dehydration/filteration and other necessary repairs shall be measured and paid separately under relevant item. Contractor shall bring the mechanic at site for first inspection of the transformer after that transformer shall be shifted at workshop complete all as directed by Engr-In-Charge.

1

-

-

... More
Transporting to burnt out transformer for repair to ciivil workshop, and any type of T& P will be required for shifting of transformer will be provided by Contractor and Strip opening of transformer and removing the top cover for repair, and taking out the burnt out core alongwith HT/LT coil (windings) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated transformer oil and connection with existing electrical system HT/LT and commissioning complete on load of capacity not exceeding 160 KVA.(Transformer oil will be measured and paid separatily).

2

-

-

... More
Transporting to burnt out transformer for repair to ciivil workshop, and any type of T& P will be required for shifting of transformer will be provided by Contractor and Strip opening of transformer and removing the top cover for repair, and taking out the burnt out core alongwith HT/LT coil (windings) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated transformer oil and connection with existing electrical system HT/LT and commissioning complete on load of capacity of 250 to 315 KVA.(Transformer oil will be measured and paid separatily).

1

-

-

... More
Supply and fixing of breather assembly of Transformer incl silica gel upto 315 KVA transformer as per existing make and type 500 Gm complete all as specified and as directed.

3

-

-

... More
Supply and fixing brass terminal stud 12 mm with nuts, check nut, oil seal and washer for HV side of transformer up to 315 KVA transformer complete all as specified and as directed.

6

-

-

... More
Supply and fixing brass terminal stud with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) up to 315 KVA transformer complete all as specified and as directed.

8

-

-

... More
Supply and fixing bushing of HV side as per existing size/Model of the capacity up to 315 KVA transformercomplete all as specified and as directed.

8

-

-

... More
Supply and fixing bushing of LV side as per existing size/Model of the capacity up to 315 KVA transformercomplete all as specified and as directed.

8

-

-

... More
Material & Labour for painting of transformers capacity up to 315 KVA including HV/LV connection box with one coat of synthetic enamel paint by using spray painting method including cleaning of existing surface of all dirt and greasy materials alongwith marking of SM/MES Nos with sticker letters n. exc 2 cm height at appropriate places complete after isolating the transformer from the electric supply and to be earthed all as specified and as directed.

1

-

-

... More
Disconnecting electric supply from both ends of defective voltage stabilizer of capacity 20 KVA to 63 KVA after disconnecting elect supply from both ends and transporting the same from Ramban/ Banihal/ Uppergund /patnitop to workshop, opening top cover, taking out transformer oil, checking for faults and replacing the defective parts, checking/testing the stabilizer, refilling and topping up the transformer oil and transporting to Banihal, Ramban and refixing in original position, making connections complete all as specified and directed by Engineer-in-charge. Note : Spares and transformer oil for top up shall be measured and paid for seperately.

2

-

-

... More
Disconnecting electric supply from both defective voltage stabilizer of capacity 100 KVA after disconnecting elect supply from both ends and transporting the same from Ramban/ Banihal/ Uppergund to Workshop, opening top cover, taking out transformer oil, checking for faults and replacing the defective parts, checking/testing the stabilizer, refilling and topping up the transformer oil and transporting back to Ranban, Banihal for refixing in original position, making connections complete all as specified and directed by Engineer-in-charge. Note : Spares shall be measured and paid for seperately.

1

-

-

... More
Disconnecting electric supply from both ends of defective voltage stabilizer of capacity 300 KVA after disconnecting elect supply from both ends and transporting the same from Ramban/ Banihal to workshop, opening top cover, taking out transformer oil, checking for faults and replacing the defective parts, checking/testing the stabilizer, refilling and topping up the transformer oil and transporting back to original place and refixing in original position, making connections complete all as specified and directed by Engineer-in-charge. Note : Spares and transformer oil for top up shall be measured and paid for seperately. Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning.

1

-

-

... More
Supply and fix the following spares to voltage stabilizers :- (a) Reversible motor low speed instant start/stop high torque having speed 960 rpm and of capacity 0.08hp.

3

-

-

... More
(b) Servo circuit card.

3

-

-

... More
(c) RC Network.

3

-

-

... More
(d) Dimmer for 300/100 KVA voltage stabilizer.

2

-

-

... More
(e) Dimmer for 63/30/20 KVA voltage stabilizer.

2

-

-

... More
(f) Supply and fixing in replacement selector switch for Ammeter/Voltmeter for pannel .

3

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 185 Sqmm 3.5 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed.

40

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 70 Sqmm 3.5 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed.

90

-

-

... More
Supply Laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in Wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor cable of size 10 Sqmm 2 core , 1100 volts, grade including taking down UNSV cable all as specified and as directed.

90

-

-

... More
Supply & fixing in replacement pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 11000 volts grade, complete all as specified & directed.

9

-

-

... More
Supply & fixing in replacement pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 65mm dia and 100mm height for working pressure 1100 volts grade, complete all as specified & directed.

6

-

-

... More
Supply & fixing in replacement Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, as under: Working pressure in volts 1100 volts, Height 100mm, max dia 115mm, section of straps 31x5mm dia of bolt 14mm, complete all as specified & directed.

6

-

-

... More
Stretching/tightening of existing ACSR conductor after loosening binding wire from insulators and removing spacers upto a level to maintain a permissible space between conductors after rebinding the conductor with insulator with 14 SWG GI wire, complete all as specified & directed.

30

-

-

... More
Trimming / cutting of tree branches of any girth, touching /obstructing the over head lines of HT/LT poles of three phase distribution system at places not more than 35 mtr span distance as directed by Engineer-in-Charge, complete all as specified & directed.

30

-

-

... More
Material & Labour Cable jointing kit for 11000 Volts grade (Earthed) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 120 to 185 Sqmm and jointing materails for making joints and testing complete all as specified.

4

-

-

... More
Supply & fixing inreplacement of Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete including taking down old unserviceable pole all as specified and as directed.

2

-

-

... More
Material & Laobour testing & Commissioning of LT pannel frame CPRI approved, indoor type,factory made fabircated to CRCA sheet of with min 1.4 mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of following parts. Incomer MCCB (a) MCCB 400 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 No Outgoing MCCB (b) MCCB 200 Amps FP 36 KA - (adjustable thermal and magnetic release) - 02 No (c) MCCB 160 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 No (e) MCCB 100 Amps FP 16 KA - (adjustable thermal and magnetic release) - 01 No (f) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 400 Amps all as required (g) Indication lamps for R, Y, B - 1 Nos (h) Digital voltmeter 0-500 volts with selector switch - 01 Set (j) Digital ammeter with CT's of suitable ratio & selector switch 0-440 A cap- 01 Set (k) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable. (l) Front operated on load change over switch 400 amps.-01 No (m) Lock pedestal - 01 No Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear/ Power Control Make of MCCB/Change Over : L&T / Legrand / Schneider / Havells/C & S Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO

1

-

-

... More
Supply and fix 11 KV CTPT metering unit , type outdoor oil cooled , pole mounted , CT Ratio:5/5 A , Burden 10 VA, Class-0.5 S , STC -3 KA/1 Sec and PT Ratio 11KV/110 V, Burden -0.50 VA, Class-0.5 S, insulation -12 KV/28KV all as per IS-2705/1992 and IS-3156/1992 all as specified and as directed.

1

-

-

... More
Supply and fixing in replacement of change over switch 4 pole 415 volts 200 Amp in conforming to IS with front operated handle complete with fixing in existing LT Panel as directed

2

-

-

... More
Supply and fix OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.