Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date14 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness.complete all as specified & directed

28.3

-

-

... More
Demolition of cement concrete (unreinforced) of any description and any position not other wise specifically provided.complete all as specified & directed

9.8

-

-

... More
Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion.complete all as specified & directed

2.3

-

-

... More
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc.

425

-

-

... More
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed

25

-

-

... More
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 105x60mm complete all as specified and directed

60

-

-

... More
S&F 100mm long butt hinges (medium weight) colled rolled mild steel fixed with welding.complete all as specified & directed

57

-

-

... More
S& F Floor door stopper of aluminium alloy body and tongue ,anodised ,with hard drawn steel spring ,fixed in floor overall length of cover plate 140mm complete all as specified & directed

7

-

-

... More
S&F Extruded aluminium alloy handles fabricated type anodised of size 125mm long 12mm dia.

38

-

-

... More
S&F 250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed.complete all as specified & directed

22

-

-

... More
S&F Aluminium anodized 150mm long barrel tower bolt of extruded section and fixed.complete all as specified & directed

42

-

-

... More
S & F Box type Steel windows with double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing. complete all as specified & directed

26

-

-

... More
S & F Box type Steel ventilators top hung double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing complete all as specified & directed

5.5

-

-

... More
M&L for 35mm thick 2nd class HW rail and style plain framed, factory made paneled shutter (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I)kiln seasoned and chemically pressure treated complete all as specified and directed.

32.1

-

-

... More
S&F 35mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.20(a), supplied and fitted to chowkats.

7.1

-

-

... More
S&F Galvanised mild steel wire cloth 0.457mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples

29.3

-

-

... More
S&F Sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 Sqm.in each pane

21.5

-

-

... More
S&F Curtain rod 25mm dia aluminum brass polished with ends bulbs rings of required size including bracket complete all as directed. Make : Vista/lever ( all golden colour).

21.6

-

-

... More
M&L for Brick work with sub class “B” bricks straight or curved on plan exc 6M mean radius build in CM 1:6 using all as specified using old size bricks complete all as specified & directed

10.5

-

-

... More
M&L Brick work with subclass 'B' old size bricks/ tiles straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 exc 6m mean radius.complete all as specified & directed

4.2

-

-

... More
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement all as specified ( internally)

295.5

-

-

... More
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished using wpc ( WPC will be paid measured and seperately) even and smooth without using extra cement complete all as specified & directed

180.4

-

-

... More
Supply only integral water proofing compound.complete all as specified & directed

24.2

-

-

... More
M&Lfor Roghening surfaces of old concrete surfaces of any description over damaged surfaces irregular fascia, chajjas and in similar work and also for narrow width etc and rendering dubbing coat 15mm thick cement plaster in CM (1:4) over a coat of cement slurry @ 3.00 Kg/Sqm making surface even followed by 05mm thick rendering in CM (1:3) finished complete all as specified and directed

6

-

-

... More
M&L for Applying two coats of synthetic enamel paint on new steel surfaces any description, not otherwise described over 10 cm width or girth complete all as specified & directed

117.4

-

-

... More
M&L for Applying two coat of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces.complete all as specified & directed

28.4

-

-

... More
M&L for Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall putty 2 to 3mm thick on plasterd surfaces preparatory to distempering on wall surface .complete all as specified & directed

240

-

-

... More
M&L for Complete removal of existing treatment applying two coats of oil bound distemper over a coat of wall care putty 2 to 3mm thick on plasterd surfaces preparatory to distempering on wall surface .complete all as specified & directed

180

-

-

... More
M&L for Preparing newly plastered surfaces of walls and applying two coats of cement base paint .complete all as specified & directed

150

-

-

... More
M&L for Complete removal of existing treatment applying two coats of cement base paint old wall surface .complete all as specified & directed

140.4

-

-

... More
M&L one coat of synthetic enamel paint on steel surfaces of any description not otherwise described over 10cm width or girth including preparation of old surfaces complete and all as specified and directed

5

-

-

... More
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including three coat of white wash on ceiling including preparation of surface .complete and all as specified and directed

15

-

-

... More
Preparation of new plastered surfaces of ceiling and applying two coat of white washing, all as specified.

15

-

-

... More
M & L for preparation of new steel surface of any description, not otherwise described, over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer all as specified and directed

5.8

-

-

... More
M&L for Machine cut kota stone flooring 18-20 mm khick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over 15mm thick screed bed in CM ( 1:4) as in floor finished rough including roughening of existing surfaces by pick axicess and applying a coat of cement slurry @ 03 Kg/Sqm of surface.complete all as specified & directed

97

-

-

... More
M&L for Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.complete all as specified & directed

21.1

-

-

... More
M&L for Marble work 15mm thick (550mm long X 75mm wide strip) as in border in flooring,over 15 mm thick screed in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with white marble including rubbing, grinding and polishing. complete all as specified & directed

17

-

-

... More
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded stone agg as in flooring finished even and smooth using extra cement.complete all as specified & directed

25

-

-

... More
M & L for Granite stone 15 to 18 mm thick. (table rubbed and polished) as in cooking plateform of size not less than 2 m in length, incl cutting for sink over 20 mm thick screed in CM 1:4 including roughing of existing surface and applying a coat of cement slurry @ 03 Kg/Sqm of surface and pointing with white cement 1:2 using marble dusts admixture of pigment to match. complete all as specified & directed

6.5

-

-

... More
All as per srl item No 43 above but of size 550x 75 - 100mm (as on edges of cooking plateform

1.5

-

-

... More
M & L for coloured Ceramic tiles 10 mmthick (square/ rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm,as in patches in floors, set and jointed with cement slurry and pointed with white or coloured cement to match with tiles over and including 15mm thick screed bed in cement mortar 1:6 complete including dismantaling /demolation/Taking down Note:- Rates also includes in this item for necessary raking, circular cutting or notching and waste on tiles complete all as specified & directed

65

-

-

... More
M & L for 25mm thick PCC 1:2:4 type B-1 as a sub base to receive topping layer finished even and rough complete all as specified & directed

117.7

-

-

... More
M & L for Non skid Ceramic tiles 10 mm thick dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.18 sqm but not in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified & directed

117.7

-

-

... More
M&L for 450x300x7mm thick glazed ceramic tiles as fixed on walls/ vertical surfaces over 15mm cement rendering in cement mortar 1:4, including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ) , removing serviceable tile to store and rubbish off the premises.complete all as specified & directed

262

-

-

... More
M & L for PCC 1:2:4 type B-1 as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc.complete all as specified & directed

1.1

-

-

... More
M & L for PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection ( 50mm thick ) finished even and fair complete all as specified & directed

72.5

-

-

... More
M/L for PCC (1:3:6) Type C1 using 20mm graded stone agg as in surface channel & drain incl form work.complete all as specified & directed

3.1

-

-

... More
M/L for extra for forming fair finished drain or channel 30 cm inner girth of cement concrete using extra cement including forms moulds, mitred/ stopped ends etc. complete and all as specified and directed

25

-

-

... More
Dismantling wrought iron or mild steel work of any description not other wise provided complete all as specified and as directed.

4.8

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauze, thickness, including Nainital or similar pattern roof coverings etc complete and all as specified and directed

285

-

-

... More
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality A complete as specified.

475

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed

265

-

-

... More
M&L M.S.work as in wind ties for roofing incl. securing bolts, posts and struts complete work conforming to Fe 290 Gde E-165 etc.complete and all as specified and directed

35

-

-

... More
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.

20

-

-

... More
Dismantling of wall and ceiling boards(fibre, pulp,insulation etc) or insulation board/slabs/blankets any thickness including cover fillets complete all as specified & directed

95

-

-

... More
Supply & fixing 'E' board 605 x 605 x 4 mm thick white prelaminated set & embosed, reinforced, designer ceiling board tiles of approved texture fixed at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be powder coated, white,.the frame work shall comprises of main runner made from 0.33 mm thick galvanised steel sheet and of size 24 x 32 x 300 mm and spaced at 1200 mm center to center fixed to be structural soffits by approved hangers at 1200 mm rawl center, hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level and fasteners and screws etc., the last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall, flush fitting of 120 mm long cross tee (with double stiching) to be interlocked between main runners at 600 mm center to center, size 1200 x 600 mm modules, cross tee longer than 600 mm to be supported independently on 600 x 600 mm moduler to be formed by fitting 600 mm long cross tee centrally between the 1200 mm cross tee. Tee, perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19 x 19 mm and 300 mm long of white colour all as per manufacturer's instructions complete all as specified & directed

95

-

-

... More
S&F Framed work rolled section as in framing compound girder staging for water tank,cooler frame as and the like built up from two or more beam or channel section or angles with plates stiffeners etc complete all as specified & directed

215

-

-

... More
M & L for PCC 1:2:4 type B-1 as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc.

0.3

-

-

... More
M & L for Form work to chajjas and cooking slab troughs and similar items including edges.for rough finished surfaces complete and all as specified and directed

4.2

-

-

... More
M & L for Form work to edges of concrete flats RCC/PCC band exc 5 cm but exc 10 cm.complete and all as specified and directed

26

-

-

... More
S&F TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending and spirally hoping for columns hooking ends and binding with MS wire annealed n.less then 0.90mm dia.complete and all as specified and directed

55

-

-

... More
M & L for RCC 1:2:4 type B-1 ( using 20mm graded crushed stoneagg) as in chajjas shelves and similar items.complete all as specified & directed

0.5

-

-

... More
S&F Vitreous China wash basin, white, flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specified & directed

1

-

-

... More
S & F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure,screwed for iron pipe 15 mm bore fancy type complete all as specified & directed

1

-

-

... More
S&F Rotational moulded polyethene water storage tank triple layer 1000 ltr capacity hoisted and fixed in position including dismantling of existing tank and including PVC float valve 20 mm bore . complete all as specified & directed

2

-

-

... More
S&F Rotational moulded polyethene water storage tank 500 ltr capacity hoisted and fixed in position, including PVC float valve 20 mm bore including dismantling of existing tank. complete and all as specified and directed

2

-

-

... More
Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 15mm bore complete all as specified & directed

17.1

-

-

... More
Taking down steel tubing and connection including cleaning for refixing or removal to store bore of pipe 20mm bore complete all as specified & directed

17

-

-

... More
S&F 20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors.complete all as specified & directed

22

-

-

... More
S&F 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down.

17

-

-

... More
M&L for Cuttings chases for concealed water tubing of concealed conduit (cutting n.exc 10 cms girth) and making good in CM ( 1:3) in brick walls.

17

-

-

... More
S&F Cast copper alloy CP bib tap fancy type screwed down , screwed for iron pipe 15mm bore of pipe complete all as specified & directed

10

-

-

... More
S&F Stop valves ,cast copper alloy ,screwed down high pressure , with crutch or butterfly handle , screwed both ends for iron pipe or for union 20mm dia complete all as specified & directed

11

-

-

... More
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 110mm bore.

6

-

-

... More
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor for 75mm bore.complete all as specified & directed

3

-

-

... More
S&F PVC (SWR) Bends any radius for 110mm bore complete all as specified & directed.

2

-

-

... More
S&F PVC (SWR) floor trap with grating including jointing to waste pipe in solvent for 75mm bore including CP grating cover with or without hole complete all as specified & directed

2

-

-

... More
M & L for cement conc type D2 1:4:8 (40mm graded aggregate) 75mm thick complete and all as specified and directed

50

-

-

... More
M&L machine pressed pre cast concrete interlocking paver ( with grey cement and pigment) any shape and size confirming to IS -15658-2006 of 60 mm thickness ,M-40 grade complete all specified and directed

25

-

-

... More
M&L machine pressed coloured pre cast concrete interlocking paver block ( with grey cement and no pigment) any shape and size confirming to IS -15658-2006 of 80 mm thickness ,Electrovibro (M-40 grade) galzed finished block complete all specified and directed

50

-

-

... More
Surface excavation n.exc 30cm deep and avg 15 cm deep and getting out any type of soil.complete all as specified & directed

87

-

-

... More
M&L Hard core of gauze n.exc 63mm deposited spreaded and leveled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface. complete all as specified & directed

13.1

-

-

... More
M & L Sand for 50 mm thick filling under interlocking paver block including watering and consolidation complete all as specified & directed

3.5

-

-

... More
M&L machine pressed coloured pre cast concrete interlocking paver block ( with grey cement and no pigment) any shape and size confirming to IS -15658-2006 of 80 mm thickness ,Electrovibro (M-40 grade) galzed finished block complete all specified and directed

50

-

-

... More
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Soft/ loose soil.complete all as specified & directed

12.2

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils.complete all as specified & directed

3.5

-

-

... More
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.

8.7

-

-

... More
M/L Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete.complete and all as specified and directed

1.3

-

-

... More
M & L for Broken brick bat hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.complete all as specified & directed

1

-

-

... More
M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing. M & L for formwork for sides of columns.for rough finished surfaces complete all as specified & directed

4.2

-

-

... More
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in foundation, plinth beams,footings etc,.complete all as specified & directed

2.3

-

-

... More
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in columns. complete all as specified & directed

1.5

-

-

... More
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in floor or roof beams complete all as specified & directed

1

-

-

... More
M & L for Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like. complete all as specified & directed

2.6

-

-

... More
M/L Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick. M & L for formwork for sides of columns.for rough finished surfaces complete all as specified & directed

14.6

-

-

... More
M & L for formwork for sides of columns.for rough finished surfaces complete all as specified & directed

14.9

-

-

... More
M & L for formwork for sides of columns.for rough finished surfaces complete all as specified & directed Use and waste of formwork for foundation beams floor beam roof beam etc as in lintel ov complete all as specified & directeder 1.5m clear span. for rough finished surfaces complete all as specified & directed

6

-

-

... More
M & L TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chips as directed

295

-

-

... More
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders complete all as specified & directed

105

-

-

... More
M&L Preparing newly plastered surfaces of walls and applying three coats of white wash.complete all as specified & directed

9.3

-

-

... More
M&L rendering 5 mm thick on internal surfaces of ceiling in cement mortar 1:6 finished even & smooth without using extra cement as specified and directed.

9.3

-

-

... More
M&L Preparing newly plastered surfaces of ceilings and applying three coats of white wash.complete all as specified & directed

9.3

-

-

... More
Dismantling terracing tile,or single layer on roof including cleaning the roof surface and filling the cracks with silicon compound if obsserved on roof complete all as specified & directed

45

-

-

... More
M&L for PCC 1:2:4 type B-1 (20mm graded aggregate ) 50mm thick as in padding finished even and smooth witout using extra cement complete all as specified & directed

45

-

-

... More
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including bitumen primer @ 3.5Kg/Sqm complete all as specified & directed

45

-

-

... More
M&L for Laying APP modified membrane 3mm thick and weighing not less than 3 kg/sqm with 160 GSM/sqm, non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap, the membrane has to be laid with LPG tourch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane. complete all as specified & directed

45

-

-

... More
M&L for Cement concrete tiles 25 cm x 25cm x20mm thick machine pressed set jointed and pointed in neat cement slurry on roof over APP membrane laid over 15mm thick cement screed bed in cement mortar 1:6 complete all as specified & directed

45

-

-

... More
SCHEDULE A PART-II ( E/M WORKS AT NAGROTA ) Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy for taking credit all as specified and as directed by Engr-in-Charge

118

-

-

... More
Taking down ceiling fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed by Engr-In-Charge.

16

-

-

... More
M&L for Concealed Point wiring using FRLS PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor earth wire drawn IN and including PVC conduit ISI marked not less than 20 mm dia concealed in wall & surface on ceiling with all conduit fittings etc incl testing and making good to disturbed surface to match existing surface. complete and all as specified and directed

93

-

-

... More
All As per Srl item N0 113 above but for one socket out let 5 Amp controlled by one switch on same board with other switch .

6

-

-

... More
All As per Srl item N0 113 above but for one socket out let 5 Amp controlled by one switch on independent board with other switch .

20

-

-

... More
All As per Srl item N0 113 above but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.

23

-

-

... More
All as per item No 113 above but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete with one double pole MCB 32 amp 240V complete all as specified & directed

2

-

-

... More
S & F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified.

106

-

-

... More
S & F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified.

26

-

-

... More
S & F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified

23

-

-

... More
S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified.

23

-

-

... More
S & F Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified.

14

-

-

... More
S & F Modular white cover plate incl Modular base frame/boxes & powder coated Modular sheet metal concealed box for 6 module complete all as specified.

20

-

-

... More
All as per Item No-123 above but 3 module complete all as specified.

19

-

-

... More
All as per Item No-123 above but 2 module complete all as specified.

8

-

-

... More
All as per Item No-123 above but 8 module complete all as specified.

7

-

-

... More
All as per Item No-123 above but 12 module complete all as specified.

3

-

-

... More
S & F Modular blanking plates 1 module complete all as specified.

12

-

-

... More
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.

59

-

-

... More
S&F for lamp holder PVC/polycarbonate type with back plate suitable alongwith 10 Watt LED Bulb for batten fittings complete all as specified and directed.

20

-

-

... More
Supply and fixing LED lights fitting 1x 18 W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.

36

-

-

... More
S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.

7

-

-

... More
Supply and fixing swing type wall mounting fan 450 mm sweep single phase AC 230/240V complete for wall mounting incl grouting, holding down bolts, nuts, and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan.

1

-

-

... More
S&F sheet metal enclosure double door for distribution board factory made for MCCB DB load link VTPN 4 way suitable for MCCBas incomer, 100 Amp,4 pole including 100 A MCCB (when MCB's are to be used) with suitable size of busbar including 100 A MCCB as incomer 16 KA complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site incl taking out of exsing UNSV DB with MCBs.

1

-

-

... More
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.

3

-

-

... More
S&F sheet metal enclosure distribution board SPN 4 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs.

1

-

-

... More
S&F MCB SPN 40 A to 63 A 10 KA 240 volts "C" series complete

4

-

-

... More
S&F MCB single pole 5 to 32 Amps 10 KA 240 volts "C" series complete

32

-

-

... More
S&F building security light luminaries energy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including MS Bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete ,all as specified and directed.

8

-

-

... More
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections.

50

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm 2 core nominal cross section in service connections

90

-

-

... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core, complete all as specified and directed by Engineer-in-Charge

60

-

-

... More
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables.

15

-

-

... More
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick excavated earth complete all as specified and directed.

10

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed.

5

-

-

... More
M&L for well burned bricks , laid flat ( old size) sub class B designation '75' for cable protection copmplete all as specifed and directed.

0.8

-

-

... More
M&L for Sand cushioning to under ground cable laid in trenches for laying of LT UG cables 8 cm depth before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2020) all as specified and directed. Note: Punned thickness shall be measured and paid to the contractor.

5

-

-

... More
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.

3

-

-

... More
SCHEDULE A PART-III ( B/R WORKS AT REASI ) Excavating in post holes (or similar holes) each n.exc 0.5 cum in soft / loose soil, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm

12

-

-

... More
M&L PCC 1:4:8 Type D2( using 40mm graded crushed stone agg) , as in fdn filling and mass concrete.

3

-

-

... More
S&F for Rolled sections as in post, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410-W (Gde- E-250 quality-A)

618.3

-

-

... More
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.

1754

-

-

... More
M&L for synthetic enamel painting two coats to steel surfaces over a coat of red oxide primer including preparation of surfaces of any description over 10cm girth or width not other wise described.

106.3

-

-

... More
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge.

153

-

-

... More
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge.

14.6

-

-

... More
SCHEDULE A PART-IV ( E/M WORKS AT REASI ) Supply installation testing & commisioing of Servo controlled voltage stabilizer (Confirming to as per BIS 9815 : Part I :1994), Three phase AC system, 50 Hz of capacity 100 KVA as per requriments) Naturally oil cooled, indoor, unbalacne type load, copper wound, with microprocessor based control card, digital type, relay free smooth and silent operation with 1st filling of new insulating oil as per IS-335 standrad packed in sealed containers, including becessary incoming and outgoing connection, complete all as specified and having following specifications (a) Input voltage 300 V to 480V (b) Output voltage stabilized at any designed/desired voltage 415V + 2.5% (c) Rated frequency 50 Hz (d) No distortion in wave form (e) Response time not to exceed 10 milli seconds (f) Sensitivity (+) 1% (g) Rate of correction 8 volt / Second (h) Efficiency more than 98% (i) Type of load Three phase, unbalanced type (j) Operation : Auto or Manual. (k) Metering : Digital AC voltmeter with selector switch for input & Output voltage. (l) PROTECDTION : (i) Overload Cut-Off and short circuit Protection (ii) High/ Low voltage cut off (iii) High/ Low voltage cut-off bypass arrangement in case of emergency (iv) Single phase prevention

1

-

-

... More
Excavation in trenches in any type of soil not exc. 1.5 m wide and not exc. 1.5 in depth for laying of cabel or pipes (where provided for protection of cable) etc. and getting out trimming the sides, forming bottom surfaces to require level complete all as specified and directed

185.5

-

-

... More
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed

107.6

-

-

... More
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed

77.9

-

-

... More
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.

55.6

-

-

... More
M&L for un-reinforced precast concrete cable cover of size 300X180X40 mm for protection of cable laid transversally along the length of cable complete all as specified and directed.

330

-

-

... More
Supply laying & testing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core.all as specified and directed

110

-

-

... More
Supply & Fix Light Grade galvanised with all fitting for crossing of Road 80 mm bore all as specified & directed.

15

-

-

... More
S&F commissioning and testing of outdoor cubical type LT Feeder piller box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring, Powder coated complete all as specified a nd directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm gradewd stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer)

1

-

-

... More
Incoming:

-

-

-

... More
(a) MCCB 100 Amp 4 pole 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 01 Nos

-

-

-

... More
(b) Alum bus bar 200 Amp TPN - 01 Set

-

-

-

... More
(c) Digital Multifunction meter showing:- V, I, PF, Hz etc with suitable CT - 01 set

-

-

-

... More
(d) Indicator lamp LED type (RYB) complete - 01 set

-

-

-

... More
Outgoing

-

-

-

... More
(a) MCCB 4 Pole, 100 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu - 01 No

-

-

-

... More
(b) MCCB 4 Pole, 63 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu (- 01 No

-

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25x4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M & L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class 'B' (old size) bricks laid dry flat, complete all as specified and directed.

5.5

-

-

... More
M&L steel tubular swaged pole 09 metre long complete with cast iron base plate finial taper plug, bolts, nuts and secrew all as specified type 410 SP-31 (9.0 metres long) including painting upto 1.5M above PCC coping in black and white strips 5 Nos each 30 CM high starting from botting of pole. The pole shall be coated with two coats of black bituminous paint throughout internally and externally up to the planting depth. The remaining portion of the exterior shall be painted with on coat of red oxidor primer including dismantling of old damaged LT poles of any type and size for taking credit complete all as specified and as directed by Engr-in-Charge Note: Excavation and Earth work, PCC in foundation and copping shall be measured and paid separately.

15

-

-

... More
Supply and Fix, shock proof, rustproof, termite resistant, weather proof, fire retardant - Class FV-0 as per IS:11731 Part-II or V-0 as per UL-94,high heat distortion temperature (200°C as per IS:10192), pole mounted Junction box, minimum size (Internally) 250 mm (H) x 200 mm (W) x 105 mm (D), all as per Cat No. “GS-JB-2520” of Make ‘Sintex’ or equivalent Model of Make ‘Hensel’ including provision of 01 (One) No. electrolytic aluminium bus bar, 10 Amps, supported on non-hygroscopic fibres and brass screws for mounting and with and including 01 (One) No. miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 6 Amps [Cat No BA10060C of Make “L&T” or equivalent Model of Make Legrand/Siemens] , complete all as specified and directed.

15

-

-

... More
S&F of 90 W LED Street Light luminaire confirmining incliding all necessary arrangemet for fixing on Pole made up SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal effiiciency 110 lumen/Watt. CCT of 5700K with SDCM of 5 and CRI70. The housing should be of non- Corrosive high - pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK ratingof 0.7. The luniunaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl takin down old unsv light fittings complete all as specified and directed.

15

-

-

... More
S & F inreplacement of GI tubing 50 mm dia light grade 1.2 mtr long pipe bent to shape 120 degree for mounting of security light and fixed to wall/pole, with suitable MS clamps 4 Nos with nut and bolt and washers including connecting complete including of suitable length as per direction and approved by Engr-in-charge,

15

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with 2 core PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section conneting from piller box to street light fitting complete all as specified & as directed..

120

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 25 sqmm 3.5 core, complete all as specified and directed.

675

-

-

... More
Supplying , installation , testing & commissioning of cubical type Feeder Pillar floor mounted outdoor type ( IP 65 potection ) suitable for 415 V , 3 phase, 4 wire, 50 HZ A C supply system having front surface area 0.5 sq. mtr (app.) comprising of the followings :-

1

-

-

... More
(a) (i )Enclosure ( IP 65 protection) fabricated in compartmentalized design from CRCA sheet steel of 3.14 mm thick for frame work and 4mm thick covers for gland plates , i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade having 300 Amp capacity extensible type TPN Aluminium bus bars of high condutivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 sec, bottom base channel of MS not less than 100mm x 50 mmx 5 mm fabrication shall be done in transpotable sections,, solid connection from main bus bar to swich gears with required size of al. bus bars and control wiring with minimum 2.5 sq. mm PVC insulated copper conductor single core , cable alleys, cable gland plates in two half etc complete as required.

-

-

-

... More
(b) Bus Chamber :

-

-

-

... More
(i) 200 Amps rated Aluminium Busbar - 04 Nos (Size of the busbar should not less than 40 x 10 mm each)

-

-

-

... More
(c) INCOMER :

-

-

-

... More
(i) MCCB TP 40 Amps, 415 volt, 16 kA- 01 Nos

-

-

-

... More
(ii) Indicating LED lamp set of 3 - 01 Set

-

-

-

... More
(d) OUT GOING:

-

-

-

... More
(i) MCB TP 415 Volts,16 Amps, 10 kA, 01 Nos

-

-

-

... More
Note : Provision for mounting astronomical switch and its allied accessories shall be made in the Feeder Pillar.

-

-

-

... More
Supply and fixing to GI tubing 40 mm Dia light grade laid in under floors/road crossing, walls and ceiling as cable protection pipe all as specified and directed by Engr-in-Charge.

20

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and Fix, Astronomical Time Switch, 110-240V 1 C/O - 2 Mod , all as per Cat No. 'T2DDT7' of Make 'L&T or equivalent Model of Make Legrand/Seimens with 3 Pole Power Contactors, Type MNX 25, AC3 Rating 25 A and AC1 Rating 45 A, all as per Cat No. 'CS94110' of Make 'L&T or equivalent Model of Make Legrand/Seimens/ HPL/ Indo asian complete all as specified and directed.

1

-

-

... More
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in base of pole, coping of above Ground level etc complete all as specified and directed.

3.1

-

-

... More
Material and labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of pole complete all as specified and directed.

7.6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.