Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date10 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665168_1Bid Award Id
ViewTender No
8070/NIT-51/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregates for making good disturbed surfaces of roads / hard standing, etc. and finishing the top surfaces even and smooth without using extra cement complete all as specified and as directed
2
-
-
... More
Taking out unserviceable Foot Valve any type and size and supply and fix new CI Foot valve of size 80 mm bore IS:4038 PN0.2 incl both ends flanged, rubber gasket of suitable size and suitable size nut/bolts all as specified and directed.
2
-
-
... More
Taking up or down steel tubing and connections and disposing off complete all as specified and as directed, earth work if any will be measured and paid separately of the bore size 15mm pipe.
100
-
-
... More
All as per item No 6 above but of size 20 mm bore pipe.
450
-
-
... More
All as per item No 6 above but of size 25 mm bore pipe.
350
-
-
... More
All as per item No 6 above but of size 40 mm bore pipe.
250
-
-
... More
All as per item No 6 above but of size 50 mm bore pipe.
250
-
-
... More
All as per item No 6 above but of size 80 mm bore pipe.
1180
-
-
... More
All as per item No 6 above but of size 100 mm bore pipe.
60
-
-
... More
All as per item No 6 above but of size 150 mm bore pipe.
150
-
-
... More
Relaying/ refixing of old serviceable GI pipe and connection as obtained from item No 5 here-in-before with running GI fittings cleaning of pipe internally and externally comple all as specified and directed of size 15mm bore pipe :- Note : New fitting (Medium grade) shall be provided
10
-
-
... More
All as per item No 14 above but of size 20 mm bore pipe.
45
-
-
... More
All as per item No 14 above but of size 25 mm bore pipe.
35
-
-
... More
All as per item No 14 above but of size 40 mm bore pipe.
25
-
-
... More
All as per item No 14 above but of size 50 mm bore pipe.
25
-
-
... More
All as per item No 14 above but of size 80 mm bore pipe.
118
-
-
... More
All as per item No 14 above but of size 100 mm bore pipe.
6
-
-
... More
All as per item No 14 above but of size 150 mm bore pipe.
15
-
-
... More
S&F steel water tubing, medium grade with flanged, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for connection and tapping from existing supply pipe lines to resume water supply complete all as specified and as directed for 15 mm bore size pipe (Note - Excavation and PCC work will be measured and paid separately.
190
-
-
... More
All as per item No 22 above but of size 20 mm bore pipe.
405
-
-
... More
All as per item No 22 above but of size 25 mm bore pipe.
315
-
-
... More
All as per item No 22 above but of size 40 mm bore pipe.
225
-
-
... More
All as per item No 22 above but of size 50 mm bore pipe.
225
-
-
... More
All as per item No 22 above but of size 80 mm bore pipe.
1062
-
-
... More
All as per item No 22 above but of size 100 mm bore pipe.
54
-
-
... More
All as per item No 22 above but of size 150 mm bore pipe.
135
-
-
... More
Material and Labour for arresting the leakage in GI pipe line of size 15,20 mm borewith cutting, threading, cleaning and including inserting of all type of new fittings/pipe viz nipples, unions, ferrule ,reducer, elbows, Tee, sockets, bends incl necessary arrangement for staging along with height of buildings upto (G +3) etc complete all as directed.
Note: (a) All materials used will be counting one job (b) Excavation and PCC work in any will be measured and paid separately.
2
-
-
... More
All as per item No 30 above but of size 25 mm bore pipe.
10
-
-
... More
All as per item No 30 above but of size 40/50 mm bore.
12
-
-
... More
S&F in repairs GI Elbow of size 20mm including necessary threading to existing pipe line required for fixing / inserting of Elbow to arrest leakage complete all as specified and as directed
100
-
-
... More
All as per item No 33 above but of size 25 mm bore
50
-
-
... More
All as per item No 33 above but of size 40 mm bore
30
-
-
... More
All as per item No 33 above but of size 50 mm bore.
10
-
-
... More
S&F in repairs GI union of size 50mm including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage complete all as specified and as directed
10
-
-
... More
All as per item No 37 above but of size 40 mm bore.
10
-
-
... More
All as per item No 37 above but of size 25 mm bore.
30
-
-
... More
All as per item No 37 above but of size 20 mm bore.
100
-
-
... More
S&F in repairs GI nipple of size 20mm (20 by 150 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
50
-
-
... More
S&F in repairs GI nipple of size 20mm (20 by 80mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
50
-
-
... More
S&F in repairs GI nipple of size 20mm (20 by 50 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
100
-
-
... More
S&F in repairs GI nipple of size 40mm (40 by 50 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
50
-
-
... More
S&F in repairs GI nipple of size 40mm (40 by 80 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
50
-
-
... More
S&F in repairs GI nipple of size 25mm (25 by 150 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
20
-
-
... More
S&F in repairs GI nipple of size 25mm (25 by 100 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
20
-
-
... More
S&F in repairs GI nipple of size 25mm (25 by 50 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
20
-
-
... More
S&F in repairs GI nipple of size 15mm (15 by 50 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
20
-
-
... More
S&F in repairs GI nipple of size 15mm (15 by 80 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
30
-
-
... More
S&F in repairs GI nipple of size 15mm (15 by 100 mm )in buildings including necessary threading to existing pipe line required for fixing / inserting of union to arrest leakage and making good the disturbed surfaces to existing specifications complete all as specified and as directed
20
-
-
... More
S&F in repairs GI socket reducer of size 25x20mm / 20x15mm in buildings including including necessary threading to existing pipe line required for fixing / inserting of reducers to arrest leakage complete all as specified and as directed
20
-
-
... More
S&F in repairs GI socket reducer of size 20x15mm in buildings including including necessary threading to existing pipe line required for fixing / inserting of reducers to arrest leakage complete all as specified and as directed
20
-
-
... More
S&F in repairs GI socket reducer of size 40x25mm in buildings including including necessary threading to existing pipe line required for fixing / inserting of reducers to arrest leakage complete all as specified and as directed
5
-
-
... More
S&F in repairs GI Elbow reducer of size 25x20mm in buildings including including necessary threading to existing pipe line required for fixing / inserting of reducers to arrest leakage complete all as specified and as directed
25
-
-
... More
S&F in repairs GI Elbow reducer of size 20 x 15 mm in buildings including including necessary threading to existing pipe line required for fixing / inserting of reducers to arrest leakage complete all as specified and as directed
25
-
-
... More
S&F in repairs GI Tee of size 25x25x25mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
20
-
-
... More
S&F in repairs GI Tee of size 25x25x20mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
20
-
-
... More
S&F in repairs GI Tee of size 25x25x15mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
20
-
-
... More
S&F in repairs GI Tee of size 20x20x15mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
20
-
-
... More
S&F in repairs GI Tee of size 20x20x20mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
20
-
-
... More
S&F in repairs GI Tee of size 15x15x15mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of tee and resuming supply complete all as specified and as directed
10
-
-
... More
S&F in repairs GI Dead Plug 20 mm including shutting of supply and necessary threading to existing pipe line required for fixing / inserting of dead Plug and resuming supply complete all as specified and as directed
20
-
-
... More
All as per item No 63 above but of size 25 mm .
20
-
-
... More
All as per item No 63 above but of size 40 mm .
15
-
-
... More
All as per item No 63 above but of size 50 mm .
5
-
-
... More
Taking down and refixing of old serviceable gate valve in any loc of any make including dismantling of serviceable ones all as directed by Engineer-in-charge of size 50mm dia :-
15
-
-
... More
All as per item No 67 above but of size 40 mm .
20
-
-
... More
All as per item No 67 above but of size 25 mm .
20
-
-
... More
All as per item No 67 above but of size 20 mm.
100
-
-
... More
All as per item No 67 above but of size 15 mm .
100
-
-
... More
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and as directed of size 50mm dia.
15
-
-
... More
All as per item No 72 above but of size 40 mm .
20
-
-
... More
All as per item No 72 above but of size 25 mm .
20
-
-
... More
All as per item No 72 above but of size 20 mm .
100
-
-
... More
All as per item No 72 above but of size 15 mm .
100
-
-
... More
S&F as in repair chlorination dozing pump of capacity 4LPH, maximum pressure 5.5kg/sqcm, stroke speed 100 duly fixed with suction/delivery pipes, duly synchronosing with the present system and fixed at any location and testing on commissioing including disposing off old/unserviceable pump complete all as specified and as directed
2
-
-
... More
Supply and fixing Chain macro heavy duty suitable for carry weight of 100 KG complete all as spd and directed by EIC.
15
-
-
... More
Supplying, laying , jointing and testing PVC insulated, multistranded copper conductor 10 Sqmm (nominal area), 3 core flat submersible cable complete all as specified and as directed
90
-
-
... More
Taking up old rusted / unserviceable CI / DI/MS water main pipes with spigot and socketed / flanged ends with all fittings including burning out lead joints and recovering lead, etc. and disposing off complete all as specified and as directed of the following sizes 300 mm bore : Note: Excavation and earthwork shall be measured and paid for separately under respective items :-
48
-
-
... More
All as per item No 80 above but of size 200 mm
45
-
-
... More
All as per item No 80 above but of size 150 mm
150
-
-
... More
All as per item No 80 above but of size 100 mm
75
-
-
... More
All as per item No 80 above but of size 80 mm.
65
-
-
... More
All as per item No 80 above but of size 50 mm.
90
-
-
... More
All as per item No 80 above but of size 25 mm.
70
-
-
... More
M&L for Cast Iron pipes with flange, spigot and socket ends cetrifugally cast. Class LA, in any length size 300mm, laid in treches complete all as specified and as directed Note- rubber joints (tyton), run lead joints, bends/tappers/tee/cross any type and size and earth work will be measured and paid separately.
30
-
-
... More
All as per item No 87 above but of size 150 mm bore
120
-
-
... More
M&L for MS black pipe 300 mm nominal bore , medium grade 'B' class for water purpose alongwith joints of ends by welding /flanged etc or other jointing materials and confirming to IS 1239 Part I in any length for classification complete all as specified and as directed .
24
-
-
... More
All as per item No 89 above but of size 200 mm.
45
-
-
... More
All as per item No 89 above but of size 150 mm.
100
-
-
... More
All as per item No.89 above but of size 100 mm
75
-
-
... More
All as per item No.89 above but of size 80 mm .
65
-
-
... More
All as per item No.89 above but of size 50 mm .
90
-
-
... More
All as per item No. 89 above but of size 25 mm.
70
-
-
... More
Material and labour for making of hydra (for collection of overhead tank's water for further distribution) duly placing a 300 MM MS pipe on PCC plateform of height minimum 120 cm of required strength, placing the dead plates and welding the plates on both end of the 300 MM bore pipe, making cutting/hole for fixing of flanged of size 150 mm/100/80/50 mm and fixing of flanged of required size on the 150mm pipe and fixing of sluice valve/NRV/Gate Valve/other small size pipe on the Hydra along with nut bolt and washers and testing of leakage complete all as directed by EIC.
1
-
-
... More
Material and labour for detection of leakage overhead tank pipe lines by breaking of PCC without demaging of CI pipe, Mannualy excavtion of inlet and outlet pipes of size CI 200/150 mm for the length upto 30 RM , Pluging leakage with necessary cutting making arrangement for inserting necessary size tail piece, Collar ,ferrule , plug , Clamp ,neessary welding work, nut bolt and washers etc complete and restoration of watersupply and refilling of the entire excavated pipe as before. The job also include re-fixing of Main inlet CI 200/150 mm bore pipe on top of the overhead tank (approximate 18 Mtr heigh) complete all as spd and directed by EIC
1
-
-
... More
S& F as in repair for CI/DI any size spigot socketed pipe bends only (any type radius and angle), tappers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch double branch, cross (all sockets or socket and spigot ) collars, end caps, tail pices and plugs up to 300 mm capacity.
100
-
-
... More
M & labour for Rubber gasket (tyton joint) complete for DI/CI pipes of 150 mm dia complete all as specified. Note: Earth work if any willl be measured and paid separately.
5
-
-
... More
M & labour for Rubber gasket (tyton joint) complete for DI/CI pipes of 300 mm dia complete all as specified. Note: Earth work if any willl be measured and paid separately.
5
-
-
... More
S&F manhole covers / valve pit covers fabricated out of MS sheet, MS flat and angle iron of required sizes or shapes required at site and painting with one coat of black synthetic enamel paint over a coat of red oxide primer including taking out / dismantling rusted or unserviceable covers of UG sump/OHT/valve pits, etc. and disposing off complete all as specified and as directed
100
-
-
... More
Material and Labour for arresting the leakage in CI/DI pipe line of size 80/100/150 mm bore by pluging leakage with necessary cutting making arrangement for inserting necessary size tail piece, Collar ,ferrule , plug , Clamp etc complete and restoration of watersupply as earlier all as spd and directed.
Note: (a) All materials used will be counting one job (b) All tail piece, Straight, bend, increasing, decreasing or double socket fittings etc and Excavation, PCC work will be measured and paid separately.
40
-
-
... More
Material and Labour for arresting the leakage in CI/DI pipe line of size 200/250/300 mm bore by pluging leakage with necessary cutting making arrangement for inserting necessary size tail piece, Collar ,ferrule , plug , Clamp etc complete and restoration of watersupply as earlier all as spd and directed.
Note: (a) All materials used will be counting one job (b) All tail piece, Straight, bend, increasing, decreasing or double socket fittings etc and Excavation, PCC work will be measured and paid separately.
4
-
-
... More
M&L for run lead joint for cast iron pipes including jointing material like spun yarn, lead, etc. complete all as specified and as directed for 150 mm bore size
50
-
-
... More
M&L for run lead joint for cast iron pipes including jointing material like spun yarn, lead, etc. complete all as specified and as directed for 200 mm bore size
30
-
-
... More
M&L for caulking of joints in existing CI pipes by pouring lead to required quantity and making the joints leak proof including bailing out leaking water by using sludge motor, etc. and excavation and earthwork in any type of soil or cutting or breaking into road/ interlocking tiles/cement concrete, etc. and making good the disturbed surfaces for the 150/200 mm bore size pipe.
60
-
-
... More
M & L GI flange joint 150 mm bore 4/6/8 holes (as directed by department) with rubber packing ring using suitable size nuts, bolts and washers, welding work complete to join two pipe of 80mm bore all as specified and as directed .
30
-
-
... More
All as per item ser No 107 above but of size 100 mm.
10
-
-
... More
All as per item ser No 107 above but of size 80 mm .
20
-
-
... More
All as per item ser No 107 above but of size 50 mm .
25
-
-
... More
Removing of GI/MS column/Socketed pipe 50 mm dia (appromimately in 3m lengths) from the bore well , removing of old UNSV flanged joint from the column pipe fixing of new pipe along with flanged at both ends with nut and bolt of suitable size, lowering the coloumn pipe along with submersible pump motor as before complete complete as specified and as directed . MS/GI pipe and flanged will be measured and paid separately.
1
-
-
... More
S&F in replacement of double flanged sluice valve of size 300 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
1
-
-
... More
S&F in replacement of double flanged sluice valve of size 200 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
2
-
-
... More
S&F in replacement of double flanged sluice valve of size 80 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
8
-
-
... More
S&F in replacement of double flanged sluice valve of size 150 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
4
-
-
... More
S&F in replacement of double flanged sluice valve of size 100 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
4
-
-
... More
S&F in replacement of double flanged sluice valve of size 50 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubber sheet nut, bolts and washers complete all as specified and directed
3
-
-
... More
S&F in replacement of double flanged Non return valve of size 80 mm bore including replacement of worn out rubber sheet nut, bolts and washers complete.
6
-
-
... More
S&F in replacement of double flanged Non return valve of size 150 mm bore including replacement of worn out rubber sheet nut, bolts and washers complete.
2
-
-
... More
S&F in replacement of double flanged Non return valve of size 100 mm bore including replacement of worn out rubber sheet nut, bolts and washers complete.
1
-
-
... More
S&F in replacement of double flanged Non return valve of size 300 mm bore including replacement of worn out rubber sheet nut, bolts and washers complete.
1
-
-
... More
S&F in replacement of double flanged Non return valve of size 200 mm bore including replacement of worn out rubber sheet nut, bolts and washers complete.
1
-
-
... More
Taking out unserviceable air valve any type and size and S&F in replcement of cast iron air valve double isolating type H40 complete with both end flanged all as per IS 14845 all as speccified and directed for 80 mm bore
4
-
-
... More
Taking out unserviceable air valve any type and size and S&F iron air valve double isolating type H40 complete with both end flanged all as per IS 14845 all as speccified and directed for 150 mm bore
2
-
-
... More
M&L construction of brick masonery valve pits of size1100x1100x900mm internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and all as directed and including demolition of existing damaged valve pit and removing all as specified and as directed.
2
-
-
... More
M&L construction of brick masonery valve pits of size 1200x1200x900mm internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and all as directed and including demolition of existing damaged valve pit and removing all as specified and as directed.
1
-
-
... More
M&L construction of brick masonery valve pits of size 900x900x900mm internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work 3mm thick MS sheet cover with locking arrangement hinges and handle rendering work, painting to all steel surfaces with two coats red oxide primer complete and all as directed and including demolition of existing damaged valve pit and removing all as specified and as directed.
1
-
-
... More
Disconnecting and taking down/up existing unserviceable sluice valve/ NRVs from pipe line including flanged joints, fittings, etc. and disposing off complete all as specified and as directed of the 300 mm size
2
-
-
... More
All as per item ser No 128 above but of size 300 mm size.
2
-
-
... More
All as per item ser No 128 above but of size 200 mm size.
3
-
-
... More
All as per item ser No 128 above but of size 150 mm size.
6
-
-
... More
All as per item ser No 128 above but of size 100 mm size.
8
-
-
... More
All as per item ser No 128 above but of size 80/50 mm size.
19
-
-
... More
NOTE :- The Items 1 to 133 will be executed under all the sites of AGE E/M Dhar road i.e Dhar road, Battal Node, Base Camp, Samanabanj, RC Peak.
-
-
-
... More
Only Supply graphite gland dori 8mm
6
-
-
... More
Only Supply graphite gland dori 10mm
5
-
-
... More
Only Supply graphite gland dori 12mm
5
-
-
... More
S&f mild steel check nut as per existing size
5
-
-
... More
Supply and fixing as in repair of Lead wool for Pipes jointing complete all as spd by EIC.
10
-
-
... More
Supply and fixing as in repair of spun yard for Pipes jointing complete all as spd by EIC.
20
-
-
... More
Deduct Schedule of Credit of Rs. (-) 154255.00 (Minus) as listed in Schedule 'A' Part-II.
Contract Sum shall be arrived after deducting the credit amount
Note: Tenderers will not quote against this item being a firm amount.
-
-
-