Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Soon31 Dec 2024
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only GOD operating rod with cover 33000 Volts grade insulation including locking arrangements, complete all as directed at site by EIC

2

-

-

... More
S&F in replacement cable end termination jointing kit, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 185/240 Sqmm, 3 core,11 KV grade, complete all as directed at site by EIC NOTE:- Item rate quoted deemed to include required T&P.

3

-

-

... More
All as per item No. 5 but for HT XLPE cable 95 Sq mm, 3 core,11 KV grade, complete all as specified and directed.

4

-

-

... More
All as per item No. 5 but for indoor type, 185/240 Sqmm, 3 core,11 KV grade, complete all as directed at site by EIC

3

-

-

... More
All as per item No. 5 but for indoor type, 95 Sqmm, 3 core,11 KV grade, complete all as directed at site by EIC

3

-

-

... More
S&F sealed maintenance free battery 100 Ah, 24 volt, UPST 100 type suitable for power pack of HT VCBs complete all as per directed by EIC.

4

-

-

... More
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 Volts, 95 Sq mm, 3 core cable grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing and taking out existing old cable complete all as specified and directed. NOTE:- Item rate quoted including excavating/ refilling/additional HT PCC Cover as per IS if required on site.

550

-

-

... More
All as per item No. 10 above but for 185 Sqmm, 3 core cable, complete all as specified and directed.

120

-

-

... More
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover, incl dismantling of existing earthing complete all as specified & tested complete.

12

-

-

... More
M&L for Dehydration /filtration of transformer oil of existing transformer installed at site with portable plant to improve the dielectric strength to 60 KV or above during filling after initial filtration including testing of dielectric strength after dehydration at site.Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) Transformer oil for topping up will be measured and paid in relevant item as required. (iv) Replacement of minor parts like Drain valve,oil seal etc.

14000

-

-

... More
M&L for transformer oil in transformer installed/ at site for toping up the level of oil having dielectric strength 40-60 KV.Transformer oil conforming to IS-335 shall be supplied in sealed container , empty barrel of transformer oil will be deposited by contractor in E/M store yard.

1400

-

-

... More
M&L for testing and checking of di-electric strength of transformer oil with testing equipment/ instruments by maintaining a gap 2.5 mm between electrodes and applying voltage with rate of rise at 2 kV per sec as per indian standards and directed by Engr -incharge .

22

-

-

... More
M&L for rectification of oil leakage from HT side of transformer 11/0.433KV upto 310 KVA by necessary repair/repalcement of bush, brass stud,Insulator,Gasket/seal etc complete with brass terminal including testing complete all as specified and directed by Engineer in charge.

10

-

-

... More
All as per item No. 16 above, but for rectification of oil leakage from LT side of transformer 11/0.433KV upto 400 KVA cmplete all as directed.

10

-

-

... More
Supplying and spreading of gravels of size 40-63 mm size around transformer plinth, two/ four pole structure and HT yard etc, complete all as specified and directed.

5

-

-

... More
M&L for replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by engineer in charge.

6

-

-

... More
M&L for replacement of Lightning arresters expulsion type for 33 KV complete with all fittings, transmission class, discharge capacity 65 kilo amp omplete all as specified and directed by engineer in charge.

1

-

-

... More
M&L for replacement of Lightning arresters expulsion type for 11 KV complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed by engineer in charge.

5

-

-

... More
M&L for replacement of Triple pole air brake Switch, Gang operated, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for 11 kV & current rating upto 200 amps 12 Insulator type complete all as specified and directed by engineer in charge.

4

-

-

... More
S&F breather assy with silica gel in replacement (for transformer of any type/cap) complete with end fitting etc complete all as specified and directed by Engineer -in-Charge

4

-

-

... More
M&L for refilling fresh Silica Gel into the breather including removal of unserviceable item. etc. complete all as specified and directed

9

-

-

... More
Checking and calibration of various type of safety relays installed in 33 KV transformer metering unit with secondary injuction test set including checking and coordination of relay settings, complete all as specified and directed (a) Digital multifunction relay. (b) Trip circuit supervision relay. (c) Master trip relay. (d) Auxilary relay for Buch, WTI, OTI trip.

2

-

-

... More
Checking and calibration of various type of safety relays, installed in HT incoming panel 11 KV with secondary injuction test set including checking and coordination of relay settings. complete all as specified and directed. (a) Over current & earth fault relay (b) Trip circuit supervision relay. (c) Master trip relay. (d) Fuse failure relay.

2

-

-

... More
Checking and calibration of various type of safety relays, installed in HT outgoing panel 11 KV with secondary injuction test set including checking and coordination of relay settings, complete all as specified and directed. (a) Over current & earth fault relay (b) Trip circuit supervision relay. (c) Master trip relay.

7

-

-

... More
Checking the functioning of buchholz relay, O.T.I & W.TI of 02 Nos of 3.15 MVA power transformers incl Note for item No 25 to 28 :- (i) All testing eqpt & any minor parts required to functioning relays of VCB is incl in the quoted rate (ii) The report shall be submitted to the Dept in triplicate. (iii) Transportation, lodging & boarding of Visiting Engineer is deemed incl in the quoted rate..

2

-

-

... More
M&L for disconnecting of defective HT Panel of 11KV volts, 3 phase from power mains and removing of the burnt or defective parts i.e. CT, PT,Insulator, insulation, Busbar, contact piece or any other connected item etc. gently and carefully, washing of the dust, rust, carbon and dirt from all parts, triping mechanism, greasing of all fixed or moving contact, vcb busbar spout, pole housing, busbar, walls of panel and painting the inner side of panel by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation new parts with necessary fixing arrangements, nut, bolts etc. including connecting up electrically and testing etc complete all as specified and directed by Engineer-in-Charge and specified in particular specification.

3

-

-

... More
NOTE: (i) Repair cost is deemed to be included Labour, equipments for repair&testing, insulation, bus bar spout, pole housing, high voltage HRC fuse for PTof VCB, paint, nut&bolts or any minor spares etc. in the quoted rate. (ii) The US/burnt parts will be contractors property & new part will be measured and paid separately under respective item. (a) Epoxy Insulator 80mm dia, 11KV, single holes of 12mm dia type, 130mm long as per existing make & model. (b) CT suitable for 11 KV VCB Panel, copper wound, of ratio P1 (200-150/5-5A) / P2 (100-50/5-5A ) type, Ins. Class B, confirming to IS 2705/1992 as per existing make and model or as directed by EIC. (c) PT suitable for 11 KV VCB Panel, copper wound, P1/P2 type of ratio 11000/√3/110/√3 Volt as per IS 3156-1992 , Ins. Class B, 50 Hz, as per existing make and model or as directed by EIC.

-

-

-

... More
M&L for Epoxy Insulator 80mm dia, 11KV, single holes of 12mm dia type, 130mm long as per existing make & model, complete all as specified and directed

10

-

-

... More
M&L for CT suitable for 11 KV VCB Panel, copper wound, of ratio P1 (200-150/5-5A) / P2 (100-50/5-5A ) type, Ins. Class B, confirming to IS 2705/1992 as per existing make and model or as directed by EIC.

3

-

-

... More
M&L for PT suitable for 11 KV VCB Panel, copper wound, P1/P2 type of ratio 11000/√3/110/√3 Volt as per IS 3156-1992 , Ins. Class B, 50 Hz, as per existing make and model or as directed by EIC.

3

-

-

... More
S&F in repair porcelain HRC AVT type fuse HT 11 KV, 1 Amps suitable for 11 KV VCB, complete all as directed by EIC.

20

-

-

... More
S&F in repair 11 KV post type porcelain insulator 320mm CD suitable for 11 KV rotating type GOD incl necessary fittings complete all as directed by EIC.

12

-

-

... More
S&F in repair Control Wiring with 1.5 sqmm FRLS copper conductor for control circuits and 2.5 sqmm FRLS copper conductor for CT circuits as per existing diagram including provided cable ties, beading etc of VCB complete all as specified and directed

2

-

-

... More
S&F in repair Ampere meter digital type, 96 x 96 mm, 0 - 200 Amps with built in selector switch complete for VCB 11 KV complete all as specified and directed

4

-

-

... More
S&F in repair volt meter 96 x 96 mm, digital type, 0- 12KV with built in selector switch complete for VCB 11 KV complete all as specified and directed

4

-

-

... More
Supply and erecting in repair true vertical steel tubular swaged pole, 13 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-64 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxide and two coats of black bituminous paint for portion embedded in concrete, complete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work).

10

-

-

... More
Dismantling of OH ACSR Conductor from the existing HT/LT pole complete all as specified and directed.

12

-

-

... More
Supply, stringing, stretching and binding with insulator, ACSR conductor (Dog) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections all as specified & directed.

12

-

-

... More
Supply and fixing in repairs pin type, polymer gray type insulator with creepage distance 320mm of tensile strength 5 KN including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for working pressure 11000 Volts grade of HT line complete all as specified and directed.

60

-

-

... More
Supply and fixing in repairs pin type, polymer gray type insulator with creepage distance 630mm of tensile strength 10 KN including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for working pressure 33000 Volts grade of HT line complete all as specified and directed.

40

-

-

... More
M&L in repairs disc type insulators, porcelain vitreous white brown or green, 90mm dia, 3mm thick Silicone Rubber housing with dry arc distance 165mm and 320mm creepage distance & Tensile Strength of 45 KN ball and socket type, incl tension clamps, nut&bolts for conductor having working pressure 11000 Volts complete all as specified and directed.

20

-

-

... More
M&L in repairs disc type insulators, silicone polymer type, with dry arc distance 400mm and 900mm creepage distance & Tensile Strength of 70 KN ball and socket type incl tension clamps, nut&bolts for conductor having working pressure 33000 Volts complete all as specified and directed.

20

-

-

... More
M&L stay assembly complete with accessories i.e. stay plate 300mm x 300mm x 6mm, galvanised thimbles, GI stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No 1 on Ser Page No 495 of MES Schedule Part-I (2009) complete including dismantling stay assembly complete all as specified and directed.

6

-

-

... More
M& L for Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 4mm dia complete.

1

-

-

... More
S&F in repair CT outdoor type suitable for 33 KV VCB (OD), copper wound, of ratio P1 (200-150/5-5A) / P2 (100-50/5-5A ) type, Ins. Class B, confirming to IS 2705/1992 as per existing make and model or as directed by EIC.

1

-

-

... More
S&F in repair PT outdoor type suitable for 33 KV VCB (OD), copper wound, P1/P2 type of ratio 11000/√3/110/√3 Volt as per IS 3156-1992 , Ins. Class B, 50 Hz, as per existing make and model or as directed by EIC.

1

-

-

... More
Trimming tree branches coming in proximity to HT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 1.5 Mtrs apart from ACSR conductor from all sides all as directed.. (Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost ). Note:- Five lines together will be measured as one span from pole to pole.

50

-

-

... More
Re-streching of loose over head ACSR conductor/AB Cables/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge)

50

-

-

... More
M&L for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.

3.2

-

-

... More
M&L of PCC for steel tubular poles (1:4:8) Type D-2 using 40 mm graded aggregate for mass filing of poles complete all as specified and directed at site.

7

-

-

... More
M&L for Coping for steel tubular poles (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site.

2.2

-

-

... More
S&F spring charging motor AC / DC of VCB trolley as per existing sample complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement spring charging gear assembly for VCB trolly of make & specifications as exist at site complete all as specified and as directed.

2

-

-

... More
Supply and fixing in replacement motor cut off for spring charging motor of VCB trolly of make & specifications as exist at site complete all as specified and as directed.

2

-

-

... More
Supply and fixing closing coil 24 V, DC for VCB trolly of make & specificatins as existing at site after taking down coil as exists at sitecomplete all as specified and as directed.

2

-

-

... More
Supply and fixing shunt tripping coil 24 V, DC for VCB trolly of make & specificatins as existing at site after taking down coil as exists at site complete all as specified and as directed.

2

-

-

... More
Supply and fixing in replacement electronic hooter of VCB complete all as specified and as directed.

6

-

-

... More
Supply and fixing in replacement HRC fuse base with HRC fuse 20A,415V,80 kA complete all as specified and as directed.

4

-

-

... More
Supply and fixing multifunctional meter for 11 KV VCB of make & specifications as existing at site complete all as specified and as directed.

2

-

-

... More
Supply and fixing in replacement selector switch suitable for amp meter/volt meter for 11 KV VCB of make & specifications as existing at site complete all as specified and as directed.

2

-

-

... More
Supply and fixing in replacement indicator lamp as per existing colour code for 11 KV VCB complete all as specified and as directed.

50

-

-

... More
Supply and fixing in replacement ZZ switch, trip circuit healthy of VCB complete all as specified and as directed.

5

-

-

... More
Supply and fixing in replacement common alarm relay voltage range 24-30V, DC of VCB as existing at site complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement microprocessor numerical relay of VCB as existing at site complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement master trip relay as existing complete all as specified and as directed

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.