Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Telecommunication Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 46,98,900
Costs
EMD
₹ 93,978Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684502_1Tender No
GE/KC-68/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking out existing old unserviceable pole (09 and 11) metres long of PCC Pole from the PCC foundation, couping and including carefully taking down existing ACSR conductor,cables, street light, security light fitting, GI brackets, looping boxe, stay assembly of any type & patten etc, after disconnection of electric supply by using necessary T&P/Crane/ any mechanical method will be applied and disposal of debris upto distance not exc 100 m complete all as specified and directed.
Note:- Hire charges of T&P / crane/hydra/JCB etc for disconnection of electric supply and cost of disposal of debris shall deemed to be included in the unit quoted rate.
4
-
-
Material and labour for PCC 1:3:6 Type C-2 (Using 40 mm grade aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and as directed
3
-
-
Material and labour for PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in copping of existing and new electric pole at site including providing necessary form work complete all as specified and as directed.
0.5
-
-
Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black japan paint after preparation of surface complete all as specified and directed.
Note:-Excavation and earth work shall be measured and paid separately.
4
-
-
Supply & install solar street lighting system suitable for 20 watts inbuilt smart charge controller with driver having efficeincy 97% with motion sensor for automatic brightening and dimming and comprising of high efficeincy PV Batteries, MS Pole painted with corrosiion resistant paint, Autonomy for 'no sunshine' days, Auto on / Off, dusk to dawn operation complete all as specified and directed.
4
-
-
M&L outdoor type street light junction boxes with PVC water tight encloser, ready made type, with provision of suitable size 25/35 sqmm 3.5core cable including aluminium bus bars for three phases and one neutral mounted on insulators and bus bar having provision of 10-32 A SP MCB terminal connection and inter connection of street light from pole to pole and pole to light fittings including necessary PVC insulated waather proof twin core 2.5 Sqmm (nominal area) aluminium conductor cable, 1100 volts grade drawn and including PVC conduit of suitable size with clamps (3 Nos) , nuts, bolts etc from Junction box to street light connection, including taking down of existing unserviceable of junction box complete all as specified and as directed .
30
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 185 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
100
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
355
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 70 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
380
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 50 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
450
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 35 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
600
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 25 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
1700
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 16 sqmm, 4 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
2570
-
-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 16 sqmm, 2 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.
Note:-
Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
2070
-
-
Supply and fixing 1100 volts grade heavy duty PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia suspension GI wire with stranded conductor 10 sqmm twin core cable flat or round including taking down old unserviceable service connections complete all as specified and directed.
200
-
-
Supply and fixing 1100 volts grade heavy duty PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia suspension GI wire with stranded conductor 16 sqmm twin core cable flat or round including taking down old unserviceable service connections complete all as specified and directed.
600
-
-
Supply and fixing 1100 volts grade weather proof twin core 2.50 Sqmm alumiunium conductor cable drwan in and including medium grade duty fixed with suitable sizes fixed with MS clamps PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete complete all as specified and directed.
500
-
-
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in Soft/loose soil complete all as specified and as directed.
930
-
-
All as per Item No: 21 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed
2
-
-
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid)
408
-
-
Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
48800
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
411
-
-
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed.
414
-
-
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
1
-
-
Material and labour for Shackle type insulator, porcelain, vitreous white / brown including galvanized mild steel straps (of size 31 mm x 3 mm) washers, insulator bolts ( 12 mm dia) washers and nuts per size of height 75 mm and dia 90 mm for working pressure 1100 Volts all as specified and as directed.
30
-
-
S&F New Aluminium conductor, steel reinforced, of any size, type, fixed to poles and stretching properly drawn for overhead lines on poles including binding at site to insulator with suitable size of wire including 15mm dia PVC seperater at equal interval including removing old unserviceable ACSR conductor complete all as specified and directed.
2.5
-
-
Restringing of existing over head sagged conductor over head lines on existing LT poles including providing binding wire, line taps , fixing of dispositioned insulators in position with nuts and bolts with washers etc.as required at site complete all as specified and directed. Note :- Quoted rate shall be deem to included the cost of winding wire and replacement of insulator if damaged during restraining of conductor.
(ii) Insulator shall be paid separately as supply only under respective item of this schedule.
1500
-
-
M&L for GI pipe 80 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
133
-
-
M&L for GI pipe 50 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
76
-
-
M&L for GI pipe 40 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
130
-
-
M&L for Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 90 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.by Engr-in-Charge
133
-
-
Supply install and testing moulded case circuit breaker (MCCB), adjustable Thermal and fixed magnetic type, Pole,415 volts,50Hz,breaking capacity 25KA,rating 63 Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
4
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 25KA,rating 125Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, Pole, 415 volts,50Hz,breaking capacity 36KA,rating 160Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 200Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, 4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 250Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Supply install and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 350Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge.
2
-
-
Painting to existing steel tubular poles of any length including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
120
-
-
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
1
-
-
(a) MCCB 350 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) (b) MCCB 125 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 03 Nos(Outgoing) (c) MCCB 63 Amps, 4 pole with breaking capacity 16KA (Adjustable thermal & magnetic release) - 01 Nos(Outgoing) (d) Digital Volt meter .Make LT (e) Indicator lamp RYB :01 Set, C&S (f) Digital Ammeter meter .Make LT
-
-
-
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
2
-
-
(a) MCCB 100 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) (b) MCCB 63 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 04 Nos (c) Digital Volt meter .Make LT (d) Digital Ammeter meter .Make LT (e) Indicator lamp RYB :01 Set, C&S (f) CT'S 200/5 01 Set Make Legrand
-
-
-
Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 750X750X450 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators . The panel shall be both side openable dust and vermin proof, protection class (IP-54) in accordance with IS-2147 and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5mm thick and 450 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrument chamber with RYB indicator LED lamps. he scope of work also comprising of the following including taking down by disconnection of all incoming and outgoing UG cable and MCCB connections of existing UNSV LT bus bar box and making good the disturbed surface :- (A) Aluminium Bus bar chamber rating : 125 Amps, TPN, 415V (B) Incoming MCCB rating : 200 Amps, 4P, 10 KA - 01 (C) Multifunctinl meter (Ampere meter and Voltmeter sutaible size) NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in uit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
8
-
-
Supply, installation, testing and ”commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-l) :1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, cooperwound, metallic bodydulypowercoated with lifting Hookstwonos, digital display type, relay free smooth and silent operation with 1*‘ filling of Transformer oil up to level having following
specification:- (a) Capacity - 150 KVA (b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage 360V-480V, Input frequency 50 Hz. (d) Output voltage - stabilized at any deigned/ desired voltage 415/ +-1 %. (e) Rated frequency - 50 Hz
(f} Waveform distortion - Nil. (g) Response time not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%. (j) Rate ofcorrection- Not less than 6 Volt second between phaseand neutral. (k) Efficiency more than 95%. (l) Type of load three phase, unbalanced type. (m) Metering - Digital display Voltmeter/ Ammeterwith multi- functionat meter.(n) Operating temperature - For indoor use upto max ambienttemp+ 55°C
(o) Dimension of tanks - (widthx depthxheight) in mm (As per manufacturer designed) (p) Oil Cap as per manufacturer recommendation. (q) Class of insulation - Class "F" (r) Mode of opera(ion Automatic/ manual. (s) V\binding Temperature rise — Max 55°C
(10°C above operating temp). (t) Transformer oil -IS 3 35 marked.
(u) Core - CRGOM4Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled NonOriented) .(v) Auto transformer (Variac) -100 percent Copperwound Electrolytic Grade.(w) Losses - As per IS Norms.
1
-
-
(x) Power Factor - Not less than 0.95. (y) Protect on —
(i) Overload protections
iij Short Circuit protections
(iii) H igh/Low voltage cut off
(iv) By pass arrangement in case of Emergency
(v) Single phase seque. (vi) Earth fault protection
(aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, Cl Rollers, Earthing
Terminals etccable box.
-
-
-
Supply, installation, testing and ”commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (Part-l) :1994, reaffirmation 2019 latest version). Three phase, four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, cooperwound, metallic bodydulypowercoated with lifting Hookstwonos, digital display type, relay free smooth and silent operation with 1*‘ filling of Transformer oil up to level having following
specification:- (a) Capacity - 100 KVA (b) Type - Suitable for unbalanced load and unbalanced input
(c) Input voltage 360V-480V, Input frequency 50 Hz. (d) Output voltage - stabilized at any deigned/ desired voltage 415/ +-1 %. (e) Rated frequency - 50 Hz
(f} Waveform distortion - Nil. (g) Response time not to exceed 20 milli seconds
(h) Sensitivity - (+/-) 1%. (j) Rate ofcorrection- Not less than 6 Volt second between phaseand neutral. (k) Efficiency more than 95%. (l) Type of load three phase, unbalanced type. (m) Metering - Digital display Voltmeter/ Ammeterwith multi- functionat meter.(n) Operating temperature - For indoor use upto max ambienttemp+ 55°C
(o) Dimension of tanks - (widthx depthxheight) in mm (As per manufacturer designed) (p) Oil Cap as per manufacturer recommendation. (q) Class of insulation - Class "F" (r) Mode of opera(ion Automatic/ manual. (s) V\binding Temperature rise — Max 55°C
(10°C above operating temp). (t) Transformer oil -IS 3 35 marked.
(u) Core - CRGOM4Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled NonOriented) .(v) Auto transformer (Variac) -100 percent Copperwound Electrolytic Grade.(w) Losses - As per IS Norms.
1
-
-
(x) Power Factor - Not less than 0.95. (y) Protect on —
(i) Overload protections
iij Short Circuit protections
(iii) H igh/Low voltage cut off
(iv) By pass arrangement in case of Emergency
(v) Single phase seque. (vi) Earth fault protection
(aa) Standard Fitting & Accessories e.g Marking plate, lifting lugs, Cl Rollers, Earthing
Terminals etccable box.
-
-
-
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 x 6 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. (ii) GI earth strip above 7.5 m length, if required, for earthing shall be paid measured and seperately as "Supply only".)
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%