Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date19 Jun 2024
Closing Date17 Jul 2024
Tender Amount₹ 28,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of plateform for installation of transformer with and including earth work Brick work,PCC,RCC,Plastering,Chain Link Fencing gate etc all as shown in Drawing No CWE/TD-230/2021 Sheet 1/1 dated 23 Jun 2021 complete all as specified and as directed.

1

-

-

... More
Voltage stabilizer for automatic operation, three phase naturally oil cooled Outdoor type & designed for input variation between 190 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA alongwith Construction of plateform and including earth work Brick work,PCC,RCC,Plastering,Chain Link Fencing gate etc all as shown in Drawing No CWE/TD-230/2021 Sheet 1/1 dated 23 Jun 2021complete all as specified and as directed.

1

-

-

... More
Supply and erect 2 pole structure on 11 meter PCC pole , anti-climbing device as enumerated in SSR Part-I with and including necessary earth work i.e. excavation,removal,returning filling etc PCC(1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation of electric poles & PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of poles,cross arms etc complete all as specified and as dierected.

1

-

-

... More
Supply & erecting in truly vertical position steel tubular swaged poles 410 SP-55 (11.00 mtrs long) complete with 300 x300x 6 mm thick MS base plate continuously welded at bottom of pole and MS sheet 2 mm thick plug welded at top, bolts, nuts & screws including one shop coat of red oxide primer and internally bituminous painted including painting with two coats of aluminium paint and black and white strips 30 cm upto 1.5mtr height from top of coping in strips including taking out old/unserviceable poles complete all as directed by Engineer-in-Charge (Earth work & PCC shall be measured & paid for separately).

9

-

-

... More
Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (12 insulator type) outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top insulator with drop out fuses operating rod 25mm bore GI pipe medium grade confirming to relevant IS, current rating 200 Amp and voltage 11 KV including jumpering, lead of wire/cable as directed at site including taking down old/ unserviceable switch. complete all as specified and as dierected.

1

-

-

... More
11000 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated , insulation screen of extruded semi conducting compound over all metellic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3x95 Sqmm + 1x 70 Sqmm complete with dead end clamp,suspension clamp,Eye Hook ,welding and cable Jointing Kit as per site requirement with the existing LT disribution system. complete all as specified and as dierected.

110

-

-

... More
XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm complete all as specified and as dierected.

40

-

-

... More
Cable jointing kit for 11000 Volts grade (E) cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 Sqmm to 95 Sqmm and jointing materails for making joints and testing complete all as specified and as dierected.

4

-

-

... More
Cable jointing kit for 11000 Volts grade (E) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 Sqmm to 95 Sqmm and jointing materails for making joints and testing complete all as specified and as dierected.

1

-

-

... More
Stay assembly with accessories and GI stay rod 16 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm x 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size withoverall dimensions 90 mm x 140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No 01 of SSR Part - I including taking down old unserviceable stay assembly (Excavation, stay clamps and concrete work etc will be measured and paid separately). complete all as specified and as dierected.

4

-

-

... More
ACSR conductor of any size and type from over head HT/ LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT/HT poles. complete all as specified and as dierected.

2.75

-

-

... More
Insulator Pin type, porcelain, vitreous, white,brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade. complete all as specified and as dierected.

27

-

-

... More
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats of aluminum paint complete all as specified and directed.

2

-

-

... More
Galvanised steel wire 4.0 mm dia for continuous earth wire/cradle guard for HT overhead line 11/0.415 KV line complete all as specified and as directed.

0.5

-

-

... More
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as dierected.

5

-

-

... More
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/stay assembly/cable all as specified and as directed.

98.57

-

-

... More
Description all as per srl item No-20 above but depth exceeding 1.5 m and not exc 3.0 m complete all as specified and as dierected.

3.29

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick all as specified and as directed.

48.33

-

-

... More
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and as dierected.

53.53

-

-

... More
GI Pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and as dierected.

10

-

-

... More
GI Pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and as dierected.

10

-

-

... More
GI Pipe light grade 40 mm bore for cable protection as a guard pipe complete all as specified and as dierected.

6

-

-

... More
Well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable , adjacent/abutting each other complete all as specified and as sirected by Engineer-in-charge in trenches over the cable for protection. complete all as specified and as dierected.

10

-

-

... More
Ducts/trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level complete all as specified and as dierected.

22.93

-

-

... More
PCC(1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation of electric poles,struts,PCC blocks etc including necessary form work complete all as specified and as dierected.

2.32

-

-

... More
PCC(1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundation of assembly,bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specifieds,struts,PCC blocks etc including necessary form work complete all as specified and as dierected.

11.02

-

-

... More
PCC (1:2:4) type B-1 using 20mm graded srushed stone aggregate as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as dierected.

4.64

-

-

... More
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm, 3.5 core, complete all as specified and as directed by Engr-in-Charge. Note: Wherever cable fixing/connection, suitable thimble should be used as per site situation

80

-

-

... More
All as per item No. 32 here in before but cross sectional area 70 Sqmm 3.5 core

80

-

-

... More
All as per item No. 32 here in before but cross sectional area 50 Sqmm 3.5 core

130

-

-

... More
Unserviceable aluminium lugs/thimble of size 150 Sqmm complete all as specified and as directed

8

-

-

... More
Unserviceable aluminium lugs/thimble of size 70 Sqmm complete all as specified and as directed

8

-

-

... More
Unserviceable aluminium lugs/thimble of size 50 Sqmm complete all as specified and as directed

8

-

-

... More
Testing and commissioning of LT panel of suitable size for 3 Phase 415 volt , outdoor weather proof vermin proof duly powder coated double door with back and front opening made out from 3.0 mm thick CRCA sheet with angle iron base frame of size 75x75 x6 mm cubical type complete with aluminium bus bar 400 Amp 4 way with proper color coding complete with PVC insulator, with IP 54 as per IS 13947 protection, fault rating 50 KA/1Sec, complete with following items including :- complete all as specified and as dierected.

1

-

-

... More
(a) MCCB 4 Pole, current rating 320 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 50 KA at 415V,50Hz, - 01 No as incomer

-

-

-

... More
(b) MCCB 4 Pole, current rating 160 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 36 kA at 415V,50Hz, - 02 No as outgoing and 01 No as spare

-

-

-

... More
(b) MCCB 4 Pole, current rating 100 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 10 kA at 415V,50Hz, - 01 No as outgoing

-

-

-

... More
(b) MCB SPN Pole, current rating 32 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 10 kA at 415V,50Hz, - 01 No as outgoing

-

-

-

... More
(d) onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 320 Amp, 415 volts 3 phase , four pole as per existing make -01 Nos

-

-

-

... More
(e) Digital Ammeter 0-400 Amp with suitable CTs and selector switch-01 No

-

-

-

... More
(f) Digital Volt meter with selector switch 0-500 V - 01 No

-

-

-

... More
(g) Indicator lamps (LED type) showing R,Y,B phases - 01 Set

-

-

-

... More
(h) internal panel wiring with suitable multistranded copper conductor PVC insulted and seathed FRLS complete with copper thimble/lugs

-

-

-

... More
(j) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA5050, 75 x 75 x 6 mm thick angle iron duly painted - 01 No.

-

-

-

... More
(k) Necessary foundation in PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 Job

-

-

-

... More
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV all as specified and as directed.

1

-

-

... More
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing complete all as specified and as dierected.

3

-

-

... More
Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick buried directly in ground ( Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected and including copper strip 20 mm x 3mm (upto the body of equipment) by means of Brazing,GI bolts , nuts, check nuts and washers earth plates surrounded by packed layers of coal dust earth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom and watering pipe 20 mm bore of GI pipe ,light grade all as shown in Electrical plate No 5 of SSR part –I testing on completion including PCC (1:2: 4) pit cover and PCC chamber in PCC 1:3 :6 type C-1 using 20mm graded crushed stone aggregate demand including excavation and earth work, disposal of surplus spoil to a distance not exc 50 m complete all as specified and as directed.

2

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 25x4mm by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 40mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, connected to LT panel board as indicated including testing complete all as specified and as directed. (resistance should be less than 1 ohm) (Tfr-04,Panel-02,GOD-01,LA-01) complete all as specified and as dierected.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.