Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date7 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 4,36,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Total Amount of Sch 'A' Part - III (Internal Water Supply)

1

337335

-

... More
Total Amount of Sch 'A' Part - IV (Internal Electric Supply)

1

818639

-

... More
Total Amount of Sch 'A' Part - V (Plumbing Work)

1

432114

-

... More
Total Amount of Sch 'A' Part - VI (Area Drainage Work)

1

1449893

-

... More
Total Amount of Sch 'A' Part - VII (Sewage Disposal Work)

1

382154

-

... More
Total Amount of Sch 'A' Part - VIII (Road, Path and Culvert Work)

1

1840099

-

... More
Total Amount of Sch 'A' Part - IX (External Water Supply)

1

141393

-

... More
Total Amount of Sch 'A' Part - X (External Electric Supply)

1

1195820

-

... More
Sch 'A' Part - XI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.

-

-

-

... More
Construction of septic tank for 100 users (Brick construction) complete shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 all as specified and directed.

1

-

-

... More
Construction of soakage well (Brick construction) 2.40mtr dia and 3.0mtr deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4 all as specified and directed.

2

-

-

... More
DWC HDPE pipe of nominal dia 75mm for protection of HT/LT cables complete all as specified and directed.

158

-

-

... More
DWC HDPE pipe of nominal dia 50mm for protection of HT/LT cables complete all as specified and directed.

740

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.

6

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed. Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.

2

-

-

... More
LT Feeder Pillar Box floor mounted, out door type, vermin proof, front & back,door openable, made out of MS Sheet 3.15 mm thick and internal partition sheet thickness not less than 2 mm, duly powder coated, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system,including grouting the legs of panel in PCC foundation 1:4:8 complete all as directed including the following. a).Aluminium bus bar , 3 Phase & neutral , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 200 Amps. b). Incommer MCCB 4 Pole 440 Volts, 125 Amps 35 kA rating- 1 No c). Outgoing MCCB FP 63 Amps 25 kA 415 Volts - 02 No (for ofr Accn block) d). Voltmeter suitable for 3 Phase 415 Volts supply system with inbuilt selector switch -1 No e). Ammeter 0-100 Amps 415 Volt with in built selector switch complete with CT of appropriate ratio.-1 No f). Indicator RYB . LED type 240 Volts- 1 Set. g). All accessories prewired with appropriate size copper strip or wire thimbles etc. h). Earthwork, PCC (civil works) etc; all as directed by Engr-in-Charge.

1

-

-

... More
Supply, installation and testing of electric chimney (ISI Marked) ducted auto clean, wall mounted type, 60cm with toughened glass with filters including motor working on 230 Volt, 50 Hz, complete all as directed.

8

-

-

... More
Construction of brick masonery valve pits of size (900mm x 900mm x 600mm) internal diamension with brick work in cement mortar (1:4) including excavation and earth work, concrete work, 3mm thick MS sheet cover with locking arrangement hinges and handle, rendering work, painting to all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and as specified.

1

-

-

... More
Cutting of CI/DI Pipe line and reducing to required length for insertion of new tee, branch pieces for size upto 100 mm dia, complete all as specified and directed. Note:- Rate quoted by the Contractor deemed to be included the rate of tee, branch pieces etc; and nothing extra shall be admissible on this account.

1

-

-

... More
Supply, installation,connecting, commissioning and testing transformer of capacity 100 KVA step down 11/0.433KV, outdoor type with totally enclosed cable boxes at HV & LV sides with suitable SS cable glands, double copper wound 3 phase 4 wire 50c/s oil immersed naturally cooled with externally cooling tube, core type delta connected on primart(HV) 11kv side and star connected on secondary(LV) 433V side having tapping ±2.5%,±5%,±7.5% and to change by means of hand operating off load tap changing gear including first filling of oil of dielectric strength not less than 45KV with all fittings such as silica gel blue in color in crystal form filled in breather pot, drain out valve, (oil tank) conservator tank of suitable capacity with level indicator,exhaust vent, temperature guage and accessories and all as per IS1180:2014 with all latest amendments complete. The transformer will comprise of oil level indicator for breather tank, lifting eye circular bolts 2 Nos, fixed on top cover plate, bottom wheels 4 Nos skid type under base plate mounted on SMC-100 channel 2 Nos not less than 3.0 meter long upto transformer plinth length/width complete all as specified and directed. Note:- Quoted rate for transformer include fixing of transformer on two pole structure.

1

-

-

... More
Point wiring for One light/fan point call bell point/fan point controlled by one way switch 5 Amp with 1.5 Sqmm single core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including unaction earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.

334

-

-

... More
All as per Srl item No. 29 above but for one 3 pin 5 Amp socket on same board.

40

-

-

... More
All as per Srl item No. 29 above but for one 3 pin 5 Amp socket on independent board.

80

-

-

... More
All as per Srl item No. 29 above but with 2.5 sqmm copper conductor for 15 Amp socket with 2.5 sqmm earth continuity conductor.

64

-

-

... More
All as per Srl item No. 29 above but one light point controlled by 2 way switches.

4

-

-

... More
LED mirror light 5 Watt, complete all as specified and directed.

24

-

-

... More
Sheet metal enclosure for DB's , MCB DB VTPN, 4 way, double door IP-43, 415 Volts, complete all as specified and directed.

4

-

-

... More
MCCB, 4 pole, 100 Amp, 415 Volt, 16 KA, complete all as specified and directed.

2

-

-

... More
MCCB 4 pole, 63 Amp, 415 Volt, 16 KA, complete all as specified and directed.

2

-

-

... More
MCB, SP, 63 Amps, 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed.

2

-

-

... More
MCB, SP, 40 Amps, 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed.

2

-

-

... More
MCB, SPN, 40 Amps, 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed.

8

-

-

... More
MCB, SPN, 32 Amps, 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed.

8

-

-

... More
MCB, SP, 5 Amps to 32 Amps, 240V, 10KA 'C' curve complete with connection testing and commissioning, complete all as specified and directed.

128

-

-

... More
Submain wiring with the size of 2x 4 sqmm + 1x 4 sqmm eath wire of FRLSH, smoke free, non toxic, non corrosive insulated stranded copper conductor with UNILAY construction single core cable 1100 Volts grade ISI marked TEC and FIA approved and drawing in concealed / surface / recessed in PVC conduit unction with all accessories , wiring complete for switches, socket, etc complete. Note:- Rates for steel conduit and any type of unction, Elbows, Tees, Bends, and any type of jointing / fixing accessories such as coupler locknuts, Saddle / Pipe hookes etc is deemed to be included in quoted rate.

200

-

-

... More
Submain wiring with the size of 4x 6 sqmm + 2x 6 sqmm eath wire of FRLSH, smoke free, non toxic, non corrosive insulated stranded copper conductor with UNILAY construction single core cable 1100 Volts grade ISI marked TEC and FIA approved and drawing in concealed / surface / recessed in PVC conduit unction with all accessories , wiring complete for switches, socket, etc complete. Note:- Rates for steel conduit and any type of unction, Elbows, Tees, Bends, and any type of jointing / fixing accessories such as coupler locknuts, Saddle / Pipe hookes etc is deemed to be included in quoted rate.

40

-

-

... More
Earthling complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal to a distance not exceeding 50m, testing on completion complete all as specified & directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.