Military Engineer Services Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Jul 2024
Closing Date12 Sep 2024
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665705_1Bid Award Id
ViewTender No
GE/U- /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 100 KVA to 400 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils, checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge.
8
-
-
Note:- Rate quoted by contractor is inclusive of following items:- (a) Servo motorwith RC net work having torque of 3 kg/cm -1 No. (b) Servo motorwith RC net work having torque of 10 kg/cm -1 No. (c) Electronic control card for automatic voltage regulation - 1 No. ( d) Transformer oil - 35 Ltr. ( e) Volt meter 0-500 capacity -1 No. ( f) Ammeter CT Operated -1 No. (g) Circuit plate 30 KVA- 400 KVA - 1 No.
(h) Pulse transformer of capacity 30 KVA-400 KVA - 01 No. (j) Rewinding for copper coil - 25 Kg.
(k) Shifting of stablizer from AOR of MPH to workshop (Tro/ Fro)
(l) OEM service engineer shall be engage for rectification of defects. (m) Minor items like Carbon Brush, Push buttons, Auto/ Manual/ Micro press switch, indicators Lamps, voltmeter/ Ammeter selector switch. (n) Contractor must provide replacement of suitable stablizer for use until it get repaired from workshop.
-
-
-
Decarbonising of LT Panel board / Feeder pillar boxes by CTC (Carbon Tetra Chloride), removing the carbon deposited inside the panel, cleaning the panel with cotton waste, applying one coat of becktol red solution, checking the faults inside the panel board and charging the LT Panel post completion of decarbonisation complete all as specified and directed by Engr-in-Charge.
Note:-(a) Proper shut down shall be taken prior the commencement of work . (b) Contractor shall provide 2 bottles of (250ml) - CTC . Cotton waste of not less than -1kg and Dr Bectol solution (250ml) - 1 no for performing the decarbonisation. (c) Fabrication of LT Panels for broken hinges shall be rectified. (d) LT Panel shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer.
(e) Marking on LT panels shall be done as per sources of power supply (1100 volts) and outgoing area by 10cm glow sign/paint all as directions of Engr-in-Charge.
(f) Rate of all sparesand metel sheet required for making doors of panels shall be measured in quoted rate of this item.
30
-
-
Taking down the unserviceable Moisture LT UG cable/ over head conductor. Supply & lay test and commissioning of LT cable XPLE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminum conductor, 1100 Volts earthed grade cross sectional area as insultrated below :-
Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately.
-
-
-
All as per serial item No 6.00 here-in-befoe but of size 16 sqmm 4 core.
500
-
-
All as per serial item No 6.00 here-in-befoe but of size 25 sqmm 4 core.
800
-
-
All as per serial item No 6.00 here-in-befoe but of size 35 sqmm 4 core.
500
-
-
All as per serial item No 6.00 here-in-befoe but of size 50 sqmm 3.5 core.
500
-
-
All as per serial item No 6.00 here-in-befoe but of size 70 sqmm 3.5 core.
500
-
-
All as per serial item No 6.00 here-in-befoe but of size 95 sqmm 3.5 core.
220
-
-
All as per serial item No 6.00 here-in-befoe but of size 120 sqmm 3.5 core.
250
-
-
All as per serial item No 6.00 here-in-befoe but of size 150 sqmm 3.5 core.
230
-
-
All as per serial item No 6.00 here-in-befoe but of size 185 sqmm 3.5 core.
250
-
-
All as per serial item No 6.00 here-in-befoe but of size 400 sqmm 3.5 core.
175
-
-
M&L earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GI medium grade. The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I complete all as specified and directed by Engr-in-Charge.
22
-
-
M&L for ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down complete all as specified and diected by Engr-in-Charge.
6
-
-
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 3.5x240 sqmm + 1x185 sqmm (bare messenger) with Aluminium alloy and Junction box. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc complete all as specified and as directed by Engr-in-Charge.
Note :- Retrived conductor scrap (Lumsum) shall be deposited AGE E/M storeyard with own arrangements by the contractor.
500
-
-
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 3.5x185sqmm + 1x150 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc complete all as specified and as directed by Engr-in-Charge.
Note :- Retrived conductor scrap (Lumsum) shall be deposited AGE E/M storeyard with own arrangements by the contractor.
500
-
-
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 3.5x 185sqmm + 1x120 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
Note :- Retrived conductor scrap (Lumsum) shall be deposited AGE E/M storeyard with own arrangements by the contractor.
500
-
-
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 3.5x25sqmm + 1x16 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
Note : Retrived conductor scrap (Lumsum) shall be deposited AGE E/M storeyard with own arrangements by the contractor.
1000
-
-
M&L for Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed by Engr-in-Charge.
36
-
-
S&F tubing 'light grade' galvanised iron with all fitting and fixing to poles, walls etc. with flat iron clamps/ bolts/ nuts/ washers or laid in floors/ under roads complete all as specified and directed by Engr-in-Charge.
-
-
-
All as per serial item No 14.00 here-in-before of size 80 mm bore.
12
-
-
All as per serial item No 14.00 here-in-before of size 50 mm bore.
12
-
-
All as per serial item No 14.00 here-in-before of size 100 mm bore.
12
-
-
Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site complete all as specified and directed by Engr-in-Charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsible to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
650
-
-
S&F straight through joint kit, heat shrinkable type suitable for 70 to 95 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
5
-
-
S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
3
-
-
S&F straight through joint kit, heat shrinkable type suitable for 240 to 400 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
4
-
-
Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB 63 amp, 25 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as specified and directed by Engr-in-Charge.
10
-
-
All as per serial item No 19.00 here-in-before but of size 100 amp, 25 KA.
12
-
-
All as per serial item No 19.00 here-in-before but of size 125 amp, 25 KA.
10
-
-
All as per serial item No 19.00 here-in-before but of size160 amp, 25 KA.
12
-
-
All as per serial item No 19.00 here-in-before but of size 200 amp, 35/36 KA.
10
-
-
All as per serial item No 19.00 here-in-before but of size 250 amp, 35/36 KA.
10
-
-
All as per serial item No 19.00 here-in-before but of size 320 amp, 35/36 KA.
12
-
-
All as per serial item No 19.00 here-in-before but of size 400 amp, 35/36 KA.
6
-
-
All as per serial item No 19.00 here-in-before but of size 630 amp, 50 KA.
2
-
-
Disconnecting & taking out the existing Unserviceable ACB from panel and S&F new ACB 630 amp, 50 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, complete all as specified and directed by Engr-in-Charge.
1
-
-
Disconnecting & taking out the existing Unserviceable ACB from panel and S&F new ACB 800 amp, 50 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as specified and directed by Engr-in-Charge.
1
-
-
M&L for aluminium thimble cable (Lugs) suitable for Cable of size 25 sqmm to 70 sqmm complete all as specified and directed by Engr-in-Charge.
650
-
-
All as per serial item No 22.00 here-in-before but of size 95 Sqmm to 120 Sqmm.
500
-
-
All as per serial item No 22.00 here-in-before but of size150 Sqmm to 240 Sqmm.
200
-
-
All as per serial item No 22.00 here-in-before but of size 300 Sqmm to 400 Sqmm.
200
-
-
S&F of steel poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate, welded to Pole, B-118 final taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coates of aluminum paint over a coat of red oxide zinc chrome primer and with two coates of black bituminous paint on the and portion embeded in concrete, making five black and white bands at lower portion of pole above ground level/ coping each 300 mm wide alternately and marking pole number with balck paint at suitable height all as specified by Engr-in-Charge.
Note: -
(i) The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch 'A'.
9
-
-
Supply, install, 150 amp copper Bus bar with enclouser wall mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement complete all as specified and directed by Engr-in-Charge.
10
-
-
M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
7.4
-
-
M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engr-in-Charge.
0.04
-
-
S & F stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
8
-
-
Supply ,fabricating and fixing in repairs cross arms ( any type) supports, bracing, stiffeners anti climbing spikes etc made out of MS channel, angle iron, flat of any size including drilling of holes making clamps including eye hooks, nuts bolts and washers etc welding if required including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
1.5
-
-
M & L for painting to steel tubular swaged pole of Overhead lines (9 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engg.-in-Charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engg.-in-charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified and directed by Engr-in-Charge.
100
-
-
Supply and fixing PVC insulation tape red,yellow, blue colour 25 mm 25 mtr length tape Roll Lall complete all as specified and directed by Engr-in-Charge.
400
-
-
S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
350
-
-
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
600
-
-
S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
1450
-
-
M&L for Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
8000
-
-
1100 Volts grade heavy duty cable PVC (in replacement) insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathered in service connections one twin core 10 sqmm cable flat or round compete all as specified by Engr-in-Charge.
1000
-
-
1100 Volts grade heavy duty cable PVC (in replacement) insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathered in service connections one twin core 06 sqmm cable flat or round compete all as specified by Engr-in-Charge.
1200
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements