Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date18 Sep 2024
Closing DateCancelled
Tender Amount₹ 9,00,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the contractor for EARTH WORK, SITE CLEARANCE and DEVELOPMENT WORKS as listed in Schedule 'A' Part-IV.

1

-

14650188.24

... More
Lumpsum price worked out by the contractor for ROAD, PATH & AND CULVERT WORKS as listed in Schedule 'A' Part-V.

1

-

6614505.28

... More
Lumpsum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Part-VI.

1

-

21015738.25

... More
Lumpsum price worked out by the contractor for PCC HARD STANDING WORKS as listed in Schedule 'A' Part-VII.

1

-

1856738.07

... More
Lumpsum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VIII.

1

-

1816867.58

... More
Lumpsum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IX.

1

-

65476.04

... More
Lumpsum price worked out by the contractor for SECURITY FENCING WORKS as listed in Schedule 'A' Part-X.

1

-

806651.08

... More
Lumpsum price worked out by the contractor for SWT WORKS as listed in Schedule 'A' Part-XI.

1

-

2000591.38

... More
Lumpsum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-XII.

1

-

127000.05

... More
Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-XIII.

1

-

7470850.53

... More
Lumpsum price worked out by the contractor for LIGHTNING PROTECTION WORKS as listed in Schedule 'A' Part-XIV.

1

-

252391.37

... More
Lumpsum price worked out by the contractor for FIRE FIGHTING WORKS as listed in Schedule 'A' Part-XV.

1

-

795625

... More
Supply , installation testing and commissioning of water cooled central AC plant complete in all respect (2 working & 1 standby), such as chiller , AHU , Ducting , pipe line , insulation , panel , pump , hot water generator . (Dimension of Msl shed 18mx18mx1.12m) Req temp 21 C± 2 C RH 40 ± 15% Note :- 1. firm will submit the detailed design duly vetted by an IIT / Approved Goverment agency . 2 . design data for air conditioning is enclosed as per Appx 'H'.

1

-

-

... More
Construction of steel gate of 5.5m wide and 3m high with wicket gate 1.2m wide and 3m high including RCC columns , painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer and two coats of colour wash over a coat of white wash to RCC column including necessary excavation and earth work in any type of soil , complete all as specified and directed.

2

-

-

... More
RCC ,1:2:4, type C-1 (using 20mm graded crushed stone aggregates) as in PCC bond stone set in CM 1:6 complete all as specified and directed.

19.87

-

-

... More
Digital type advanced lightning strike/search counter with charge, time and date recorded , conforming to BSEN 62561-6 complete all as specified and directed.

1

-

-

... More
Pea gravel of 10mm size, filling dry , handpacked tightly complete all as specified and directed.

47.25

-

-

... More
Supply , installation , testing and commissioning of Distribution transformer of capacity 100 KVA step down, indoor type complete with standard fittings, HT 11 KV 3 phase, LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage including comprising of following:- (a) No load voltage ratio 11 KV/433V (b) Vector Group DYN 11 (c) Two core type double copper wound (d) temperature rise 45/50 degree centigrade (oil/winding) (e) tap changer on HT side with + 7.5% in steps of 2.5% each (f) cable end box on HT and LT side to accommodate cables (g) conservator with drain valve (h) explosion vent with diaphram and sighting glass (j) air release plug (k) earthing terminals 02 Nos for body and 02 Nos for neutral (l) lifting lugs (m) flanged rollers (n) silica gel breather with transparent body and oil seal (o) radiator with top and bottom shut off brass gate valves (p) brass/ gun metal drain valve (q) first filling of transformer oil (r) cooling ONAN (s) inspection cover (t) danger notice board (u) cable entry box complete with all necessary control cables, necessary civil works for making foundation for transformer mounting etc complete all as specified and as directed.

1

-

-

... More
Supply , installation , testing and commissioning of 11 kv ,630 amps ,25 KA ,outdoor type LBSSFU with HT fuse trip ,single ICOG panel ,having provision for terminating both incoming & outgoing cables as per BOM enclosed -HT fuse of 20 amps having following additional facilities : (a) HRC Fuse 11 kV -03 nos (b) Indications for mechanical ON/OFF (c) Control switch /Push button for manual trip push and electrical trip push button with control wiring with appropriate size and colour (d) Bus bar aluminum 630 amps (e) Panel shall be dust and vermin proof made of 3.15mm CRCA sheet duly powder coated. (f) Provisioning for receving of incoming and outgoing cables through bottom entry with glands. (g) Surge arrester (9kV,10 kA)

8

-

-

... More
Supply , installation , commissioning and testing of ECO friendly diesel engine driven water cooled generating set of capacity 100 KVA / 80 KW ,415 volts ,AC supply ,50 HZ ,3 phase 4 wire ,0.8 PF at NTP ,speed 1500 RPM mounted on common base plate with flexible coupling and meeting the requiements of IS-4722/BIS specificaiton with CPCB approved accoustic enclousres fabricated out CRCA sheet 2mm thick and structual sheet metal base frame. Sound proofing of enclouser is done with high quality foam conforiming to IS 8183 of 25mm thickness and density 30Kg/M3 complete including PCC foundation in all respect complete as per manufactures recommendations. (a) Diesel engine : Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specifacition provided with blower fan ,12 volts self starting including maintenance free battery of suitable capacity ,charging dynamo/alternator ,air cleaner ,diesel /oil filters complete in all respect . The engine shall be capable of taking 10% overload for one hour for every 12 hours of running confirming to the enviroment (protection act 1986) (29 of 1986) and as amended vide Gazette of India Notificaitons Part -II Section -III sub Section (I) dated 12 Jul 2004 and latest CPCB norms (b) Engine Instructions panel: All relevant information shall be displayed on a complete panel for easy monitoring of lubricant ,oil pressure ,battery charging ,ammeter ,hours meter ,starting switch etc. (c) Fuel tank: In built fuel tank of adequate capacity with stop cock ,drain plug and nessery fuel pipe complete as per manufactures recommendaitons . (d) Altrnator: 100 KVA / 80 KW at NTP , 3 phase ,50 HZ ,415 volts ,AC supply ,copper wounded ,0.8 PF at 1500 RPM , this shall be self excited screen protected and drip proof type bruchless ,confirming to relevant IS/BIS code as per latest manufacturing schedule (e) Control panel: The standerd control panel shall be built in acousitc enclousers with the following accessories complete wired with suitable size of copper cables: (i) MCCB of suitable rating with over load and short ciruit protecion (ii) Digital ammeter (iii) Digital voltmeter (iv) One set of indicating LED lamps RYB and fues (v) Frequancy meter ,RPM meter ,Hour meter , fuel level indicator (vi) KWH meter electronic tamper proof digital for 3 phase 415 volts AC unbalanced load of suitable capacity. (vii) water temperature oil pressure gague. Note : The gen set must be affixed with label meeting the following requiements (The label shall be durable and legible ) (1) Name and address of the engine manufacture (2) Statement that this engine conforms to the enviorement protection . (3) Type and approval certificate number. (4) Date and manufactatured of gen set. (F) ACCOUSTIC ENCLOUSER: Accoustic enclouser is made out of CRCA sheet and ISMC base frame painted. The walls of enclusers will be insulated with rockwool so to canopy with 75 dba at 1mtrs sound leveled by ministry of enviorment and forest . The enclouser shall have following provisions:- wall of enclouser will be insulated as per manufactures recommendations with the following : (I) Fitting arrangment (ii) Point for neutral and body earthing (iii) Lub oil drainage (iv) Air breather (v) Hood or rain protection (vi) Easy stop push button (vii) Panel meter viewing window (viii)Tube light fitting of suitable wattage NOTE: (a) DG set should be sound proof as per lastest policy. (b) First filling of Engine oil and fuel etc should be arranged by the contractor.

1

-

-

... More
Supply , installation , commissioning and testing of ECO friendly diesel engine driven water cooled generating set of capacity 100 KVA / 80 KW ,415 volts ,AC supply ,50 HZ ,3 phase 4 wire ,0.8 PF at NTP ,speed 1500 RPM mounted on common base plate with flexible coupling and meeting the requiements of IS-4722/BIS specificaiton with CPCB approved accoustic enclousres fabricated out CRCA sheet 2mm thick and structual sheet metal base frame. Sound proofing of enclouser is done with high quality foam conforiming to IS 8183 of 25mm thickness and density 30Kg/M3 complete including PCC foundation in all respect complete as per manufactures recommendations. (a) Diesel engine : Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specifacition provided with blower fan ,12 volts self starting including maintenance free battery of suitable capacity ,charging dynamo/alternator ,air cleaner ,diesel /oil filters complete in all respect . The engine shall be capable of taking 10% overload for one hour for every 12 hours of running confirming to the enviroment (protection act 1986) (29 of 1986) and as amended vide Gazette of India Notificaitons Part -II Section -III sub Section (I) dated 12 Jul 2004 and latest CPCB norms (b) Engine Instructions panel: All relevant information shall be displayed on a complete panel for easy monitoring of lubricant ,oil pressure ,battery charging ,ammeter ,hours meter ,starting switch etc. (c) Fuel tank: In built fuel tank of adequate capacity with stop cock ,drain plug and nessery fuel pipe complete as per manufactures recommendaitons . (d) Altrnator: 100 KVA / 80 KW at NTP , 3 phase ,50 HZ ,415 volts ,AC supply ,copper wounded ,0.8 PF at 1500 RPM , this shall be self excited screen protected and drip proof type bruchless ,confirming to relevant IS/BIS code as per latest manufacturing schedule . (e) Control panel: The standerd control panel shall be built in acousitc enclousers with the following accessories complete wired with suitable size of copper cables: (i) MCCB of suitable rating with over load and short ciruit protecion (ii) Digital ammeter (iii) Digital voltmeter (iv) One set of indicating LED lamps RYB and fues (v) Frequancy meter ,RPM meter ,Hour meter , fuel level indicator (vi) KWH meter electronic tamper proof digital for 3 phase 415 volts AC unbalanced load of suitable capacity. (vii) water temperature oil pressure gague. Note : The gen set must be affixed with label meeting the following requiements (The label shall be durable and legible ) (1) Name and address of the engine manufacture (2) Statement that this engine conforms to the enviorement protection . (3) Type and approval certificate number. (4) Date and manufactatured of gen set. (F) ACCOUSTIC ENCLOUSER: Accoustic enclouser is made out of CRCA sheet and ISMC base frame painted. The walls of enclusers will be insulated with rockwool so to canopy with 75 dba at 1mtrs sound leveled by ministry of enviorment and forest . The enclouser shall have following provisions:- wall of enclouser will be insulated as per manufactures recommendations with the following : (I) Fitting arrangment (ii) Point for neutral and body earthing (iii) Lub oil drainage (iv) Air breather (v) Hood or rain protection (vi) Easy stop push button (vii) Panel meter viewing window (viii)Tube light fitting of suitable wattage NOTE: (a) DG set should be sound proof as per lastest policy. (b) First filling of Engine oil and fuel etc should be arranged by the contractor.

1

-

-

... More
Fire Hydrant landing valve type A (single head outlet) of 63mm dia conforming to IS 5290 complete all as specified and directed.

2

-

-

... More
LLDPE septic tank 100% eco friendly (as per IS 2470 (part-I) -1985) , leak proof durable and excellent performance through massive reduction of BOd with a up flow filter including media (capacity 3000ltrs for 10 users) design to carry sewage and sullage water including excavation in any type of soil , PCC 1:4:8 below foundation , returning filling and removal of excess soil upto 100mtr and including inlet and outlet connection with suitable DWC (SWR) flexible pipe with all nessessary fittings. (a) Tanks should not be laid at a gradient not steeper than 1:50 in order to minimize turbulence in the tank. (b) Ventelating pipe shoud be provided atleast 50mm dia and min 2mtr heigh . the top of the pipe shall be provided with a suitable cage of mosquito proof mess. (c) The minimum distance between septic tank and sokage well should be 3m. (d) The diameter of tank should be 1.65mtr and heigh 1.95mtr and thickness of pipe 100mm , chamber volume 2.01 cum and filtter volume should be 0.99 cum of any make from sintax/united/supreme. (e) Rate are inclusive of excavation , bedding and laying including PVC pipe 4 to 5mtr length and suitable pipe dia for connection to inlet and outlet from septic tank with manhole and sokage well & haunching/benching , returning filling and removal of excess soil upto 100mtr complete all as specified and directed.

1

-

-

... More
Supply , installation , testing and commissioning of 11 KV HT 3 phase 50 Hz totally metal clad horizontally isolated and horizontally draw out type , 400 amps ,having repturing capacity 250 MVA, 18.4 KA for 1 sec indoor floor mounted type Vacuum circuit breaker for incomer conforming to IS : 13943 of latest version comprising of following specifications :- (a) 630 Amps continous rated electrolytic copper bus bar droppers and bus bar should be insulated with full system voltage sleeves of reputed Make- raychem / Denson/ m seal (b) Truck/ trolly mounted vacuum circuit breaker should have three Nos resin encapsulated vacuum bottles of the same manufacturer as of circuit breaker . (c) Motorized spring charging mechanism with integral spring charging handle or can be supplied loop for manual spring charge . (d ) Cast resin copper wound current transformer shall be conforming to IS : 2705 of latest version of rating 12 KV , 400-200/ 5-5A , No of core 2 , core I for metering and core II for protection 1 : 1.0 10 VA core 2 , 5 P 10 , 15 VA . (e) Cast resin copper wound potential transformer conforming to IS ; 3156 of latest version of rating 3 phase 11 KV/√3/110V/ √ 3 , 100 VA , CI 1.0 CI 3P and HT fuse at the primary end and four pole MCB at the secondary end of the PT

1

-

-

... More
Structural steel work conforming to grade Fe-410-S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of zink chrome primer and two coats of aluminium paint for 11KV insulation complete all as specified and directed.

10

-

-

... More
Voltage stabilizer of capacity 100 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 volts with accuracy ± 2.5% and speed of correction 8 Volts per second complete all as specified and directed.

1

-

-

... More
LED solar street light fittings 24 watt LED solar standalone street light having MPPT charge controller ,IP-66 protection 50 Wp PV module ,12.8 V/24 Ah LiFe-PO4 (Lithium Ferro Phosphate ) battery pack , 6metre long MS galvanised tubular pole (Hot dip galvanized ) ,theft rertardant Metallic battery box mounted on pole top , 5700 K including company name should be embossed /engraved on the dia cast aluminum housing of the luminaire complete all as specified and directed Make : Havells or technocommerically equivalent of Philips /Crompton /Wipro. Note :(i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboratory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 2 years form the date of completion. (iii) Contractor shall arrange complete material at site for approval of GE before incorporation in the work.

16

-

-

... More
Supply , installation , commissioning and testing of totally enclosed feeder piller indoor type (IP-65) fabricated out of 2mm thick CRCA sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt 50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault level at 415 Volts having legs 45cms made out of 65x65x6mm angle iron grouted on brick masonry plateform upto 30cms .Brick masonry plateform should be 60cms above the Ground Level comprising the following :- (i) The panel shall be front operated with cable entry from the bottom with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI and width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonry work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work ,PCC copping 1:2:4 type B-2 (using 40mm graded stone aggerate ) ,deemed to be included in the item rate . No extra payment will be made. (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus bar shall be part of the main feeder pillar. (a) MCCB 4 pole, 250 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for Incoming) complete all as specified and directed. (b) MCB SPN 10 Amps - 01 No( For Missle Shed ) (for out going) complete all as specified and directed. (b) MCCB 3 pole, 200 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 No(AC Plant and AHU ) (for out going) complete all as specified and directed. (c) MCB SPN 40 amps - 01 No (for Guard room) ( out going) complete all as specified and directed. (d) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No. complete all as specified and directed. (e) Digital Voltmeter 0 to 500 V with selector switch - 01 No. complete all as specified and directed. (f) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) complete all as specified and directed.

1

-

-

... More
Cable route indicator of 10cm dia ,CI plate 6mm thick embossed with raised lettering HT cable 11000 volts with size of cable painted with brown luminus paint and mounted on angle iron 25mmx25mmx3mm and 0.6mtr long embedded in PCC block 1:2:4 (size 30cmx15cmx15cm ) type B-1 using 20mm graded crushed stone aggregate complete all as specified and directed.

133

-

-

... More
Cable route indicator of 10cm dia ,CI plate 6mm thick embossed with raised lettering LT cable 1100 volts with size of cable painted with brown luminus paint and mounted on angle iron 25mmx25mmx3mm and 0.6mtr long embedded in PCC block 1:2:4 (size 30cmx15cmx15cm ) type B-1 using 20mm graded crushed stone aggregate complete all as specified and directed

4

-

-

... More
Soakage well of size 1.80 metre dia and 3.00 metre deep including excavation in ordinary soil, foundation in PCC 1:3:6, walls of honeycombed and solid in M25 concrete including intercepting chambers, screen chambers, brick work in CM , RCC cover slab in M25/RR masonry /filling with brick bats complete complete all as specified and directed.

1

-

-

... More
Rubber mat 1x2x19mm complete all as specified and directed.

4

-

-

... More
Earth Work in rough excavation in any type of soil by mechenical means (hydraulic excavator) exceeding 30 cm in depth, complete all as specified and directed by Engineer-in-Charge.

22454.16

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.